PRODUCT

Product Instruction

Thank you for purchasing the Carbon Monoxide Alarm of our corporation. Please read the operation manual carefully, before using the product. This manual is applicable to Carbon Monoxide Alarm of KD-216LE.
Carbon Monoxide Alarm of KD-216LE is a kind of CO Alarm product with audible and visible, acousto-optic alarm indicator.

Characteristics of product :
Perform the standard BS EN 50291-2018, It is mainly used for the detection and alarm of harmful gas of CO. Using detection method of electrochemical sensor. It is characterized by good gas selectivity, high detection sensitivity, stable operation ,strong anti-interference, small volume and long service life. And equipped with sensor fault self-test warning, lower power warning ,end of life warning, low concentration harmful warning and other functions.

Key points :
In order to use the product correctly, please read the manual carefully before using the product.
The Carbon Monoxide Alarm is only used for detecting carbon nonoxide gas, and cannot be used as a smoke alarm or any other gas alarms. In addition, the detector can only detect carbon monoxide gas in the surrounding space. If you want to protect your family effectively, please install the detector in every room where carbon monoxide leakage may occur !

Usage of carbon monoxide

Alarm (KD-216LE)

  1. Electronic parameters of CO Alarm
  2. Brief introduction of CO Alarm
  3. Basic components of Alarm
  4. Structure and function of Alarm
  5. Basic information indication and use
  6. Basic information indication of Alarm
  7. Turn on and use
  8. Working state and daily test of Alarm
  9. Monitoring state of Alarm
  10. Alarm and removal of Alarm
  11. Warning of low CO concentration
  12. Daily test
  13. Mute operation of Alarm
  14. Fault alarm and handling
  15. Sensor fault alarm and handling
  16. Low power alarm and handling
  17. The reason of shortening battery life of Alarm
  18. Service life and end of life warning of Alarm
  19. Service life of Alarm
  20. End of life warning of Alarm
Installation of carbon monoxide

Alarm (KD-216LE)

  1. Installation place
  2. Installation method
  3. Installation notes
Daily maintenance and notes
  1. Other chemical gases influence on the Alarm
  2. Cleaning and maintenance of Alarm
  3. Frequently asked questions (FAQs) and notes
  4. The harm of disassemble and modify, repair Alarm without authorization.

Additional instructions

  1. Recognition of carbon monoxide (CO)
  2. How is carbon monoxide produced
  3. Effects of carbon monoxide on human health
  4. The harm of carbon monoxide to the family
  5. Poisoning symptoms of carbon monoxide
  6. Treatment of carbon monoxide poisoning
  7. How to deal with harmful CO or warn of CO Alarm
List of accessories

Usage of carbon monoxide Alarm (KD-216LE)

Electronic parameters of CO Alarm

  • Effective detection of gas: carbon monoxide

  • Size:1108032MM

  • Weight: about 150g

  • Power supply : build-in DC 3.0V ,2400mA/H disposable lithium battery Low power prompt: low voltage prompt when the voltage is lower than 2.2V, and it can maintain normal operation about 7 days from the prompt.

  • Working environment: temperature -10°C to 40°C relative humidity 0-93%RH

  • Static working current : <9uA

  • Alarm current: <110mA

  • Alarm sound: >85dB (3M distance)
    Alarm standard for detection time of CO concentration: BS EN

  • 50291:2018

  • EN50291-1 : 2018 CO alarm standard table

Alarm Standard| co

Concentration

| Without alarm Before| With alarm Before
---|---|---|---
A| 27±3 PPM| 120 min| —
B| 55±5 PPM| 60 min| 90 min
C| 110±10 PPM| 10 min| 40 min
D| 330±30 PMM| —| 3 min

  • Low concentration of CO indicates: A
  • CO concentration: >40 PPM, duration >50 minutes
  • Exit alarm state: the Alarm can exit the alarm state when the CO concentration is less than 40 PPM, and return to normal monitoring state automatically or manually within 6 minutes in clean air.
  • Power indicator : flash once about 50 to 55 seconds
  • Fault detection : a fault alarm will be issued within 3 minutes after the fault occurs.
  • Applicable place: home, hotel room, warehouse,basement.
  • Valid life: 10 years
  • Key points :
    For your life safety, after the end of the 10-year service life of the product, it is prohibited to use the expired product anymore, and scrap it according to the local regulation.

Brief introduction of CO Alarm

Basic components of Alarm
The Alarm is only used to detect gas of carbon monoxide and the basic components are as following pictures (KD-216LE):

LIORQUE-KD-216LE-Carbon-Monoxide-Detector-10-Year-Battery-FIG-
\(1\)

  1. Detector (Alarm)
  2. Buzzer
  3. Power indicator
  4. Fault indicator
  5. Alarm indicator
  6. Inlet of sensor
  7. Test button
  8. Power switch
  9. Mounting hole
  10. Fixed mounting plate
  11. Buckle
  12. Mounting screw hole
Structure and function of Alarm
  1. Detector (Alarm) : detector body.
  2. Buzzer: sounding device of detector.
  3. Power indicator: green light, which is used for power indicator of normal operation.
  4. Fault indicator: yellow light, which is used for sensor device fault indicator of detector.
  5. Alarm indicator: red light, which is used for alarm indicator of Co occurs.
  6. Inlet of sensor:inlet channel of detection gas
  7. Test button: testing and mute operation.
  8. Power switch: turn off or on the alarm during transportation or use.
  9. Mounting hole: the mounting hole fits with the (11)buckle of (10)fixed mounting plate.
  10. Fixed mounting plate: used to fix the Alarm to the wall.
  11. Buckle: the buckle fits with (9) the mounting hole.
  12. Mounting screw hole: the hole position of lock screw , which is used for fixing the (10) fixed mounting plate to the wall.

Basic information indication and use

Basic information indication of alarm

LIORQUE-KD-216LE-Carbon-Monoxide-Detector-10-Year-Battery-FIG-
\(3\)

LIORQUE-KD-216LE-Carbon-Monoxide-Detector-10-Year-Battery-FIG-
\(4\)

LIORQUE-KD-216LE-Carbon-Monoxide-Detector-10-Year-Battery-FIG-
\(5\)

LIORQUE-KD-216LE-Carbon-Monoxide-Detector-10-Year-Battery-FIG-
\(6\)

  1. Power-on prompt :
    When the Alarm turns on the power, and issues a power-on prompt, indicating that the power is connected and on ,and all indicators and buzzer can work normally.

  2. Power indication :
    The POWER indicator (green light) flashes once in 50 to 55 seconds, when the Alarm monitoring in the air. If the low concentration of CO is detected ,but no alarm occurs, and the interval time will be less than 50 seconds.

  3. Lower power warning
    When Alarm is working, a low power warning will be issued at least once every minute when the power voltage is lower than 2.2V.

  4. Fault warning
    When the Alarm works ,if the sensor and detection circuit are in fault ,and a fault warning will be issued not later than two and a half minutes, and then a fault warning will be issued at least every minute until fault is eliminated.

  5. End of life warning
    Alarm will issue the end of life warning, after the Alarm works for 10 years. Indicating that the product can not be able to use at the end of service life.

  6. Alarm warning
    When the Alarm detects CO concentration and duration of CO reach the alarm standard EN50291, it will issue alarm warning for more than 3 cycles, with the interval less than 6 seconds. Exit the alarm warning within 6 minutes after the CO disappeared.

  7. Alarm mute indication
    Press the “TEST” button, which the Alarm will enter the alarm mute indication, when the Alarm issues alarm warning and the CO concentration is less than 250 PPM.The ALARM indicator flashes the same way as the ALARM indicator of alarm warning, but the buzzer does not sound. But it will be recovered to alarm warning automatically after the duration is not more than 10 minutes. Press the TEST button if the Alarm in alarm mute indication ,and can recovered to alarm warning immediately.

  8. Low CO concentration warning
    When the Alarm detects CO concentration greater than 30 PPM and duration more than 30 minutes, and not reached the alarm standard EN50291, it will issue a low CO concentration warning every 3 to 5 minutes.

  9. Manual test indication
    Press the TEST button and the Alarm issues test indication ,when the Alarm works in normal monitoring state; Press the “TEST” button if it is in alarm warning, and Alarm will issue mute indications.

Turn on and use
The Alarm (KD-216LE) with built-in 3V,2400mA/H disposable lithium battery, which is not replaceable, and can be used and work for 10 years during normal monitoring state.
The Alarm is equipped with a power switch, and error prevention function. If the switch is not turned on ,the Alarm cannot be buckled on the mounting plate. It may damage the alarm, if the user buckles forcibly. The user must pull (8) the power switch to “ON” for turn on before use and installation.

Please pay attention to the indicators and sound,when the Alarm is turned on ;and the “power on prompt” information will be issued after the power is switch on. If the information of power on conforms to the description in the manual (3.1);The indicators and sound device work normally ,and the normal monitoring state can be entered after the power is turned on for 30 seconds. If pressing the “TEST” button after the power is turned on and within 30 seconds, which is invalid.

It must be carried out in a pure air environment without carbon monoxide, when turn on the Alarm. Otherwise it will issue sound of Alarm immediately after power-on.

WARNING :
The user must pull the power switch to “ON” for turn on , before use and installation. Please do not buckle the Alarm on the mounting plate forcibly, when the power switch is not turned on ,which may damage the product. And please carried out in a pure air environment without carbon monoxide; otherwise it will issue sound of Alarm after power-on.

Working state and daily test of Alarm

Monitoring state of Alarm
The alarm turns on the power for 30 seconds, and then enters the monitoring state after the green power indicator flashes once. The power indicator flashes every 50 to 55 seconds, in the pure air, while working in the monitoring state. If carbon monoxide in the air, the power indicator will flash every 30 seconds. The fault indicator and Alarm indicator are always off.

Alarm and removal of Alarm
When the Alarm detects the concentration of CO in the surroundings and duration reaches the alarm standard EN50291,and Alarm will warn. When the CO concentration is lower than 40 PPM for 2 minutes, the Alarm will be stop the alarm warning.
After the alarm warning occurs, the Alarm will exit alarm warning and return to the monitoring state, if it is in pure air within 6 minutes or press “TEST” button for 1-3 seconds manually.

Key points :
When you hear continuous alarming, there maybe dangerously high levels of CO around. Please leave the site immediately and ask for help.

Warning of low CO concentration
In daily life, some of low concentration of CO are present ,such as smoking for a long time, lighting candles, and smoke from daily cooking can produce lower levels of CO. Although these low concentration of CO are not enough to affect the health of normal person ,but for people who are weaker, pregnant women,infants, patients and elderly are not well exposed to this environment for a long time. Please try to avoid it, which maybe bad for your health. But this warning is not seriously, please don’t cause panic.

When the Alarm detects CO concentration above 30 PPM and duration more than 30 minutes, but not reached the alarm standard EN50291, and Alarm will issue low CO concentration warning. This warning was described in 3.1, and obvious differences with alarm warning.

  1. Difference between low CO concentration warning and alarm warning.

LIORQUE-KD-216LE-Carbon-Monoxide-Detector-10-Year-Battery-FIG-
\(7\)

When Alarm in low CO concentration warning, that CO concentration should be lower than 25 PPM or in pure air to e, If the CO concentration and duration reach the standard EN50291, it will be changed to Alarm warning.

Key points :
The Alarm indicator issues 4 slower sounds every 3 to 5 minutes , and not continuous alarm sound. It is low concentration warning . Please try to avoid it ,people who are weaker, and
please don’t cause panic. When you hear continuous alarming with a short interval, it may be alarm warning with harmful cO,please leave the site immediately and seek for help.

Daily test
When the Alarm in normal monitoring state, please press the ” TEST” button at least once a week for manual testing to ensure that probe, indicator ,and the buzzer in normal operation .

The Alarm test which is press the “TEST’ button manually, and indicators flash and buzzer issues sound, which is information of test prompt, when Alarm in monitoring state. The POWER, – FAULT,ALARM indicators flash once at the same time, when the ” TEST” button is pressed. If the Alarm in normal will issue a periodic alarm warning; If in a fault it will issue fault warning. If Alarm in normal,it will issue alarming warning continuously,when keep pressing the “TEST” button.

When the Alarm has performed a test operation, the second test operation can only performed after issues the test prompt information, which the interval of 5 second at least.

Key points :
To ensure the Alarm is in normal working state, please test once a week at least.

Mute operation of Alarm
Alarm will enter the mute state, when the Alarm issues alarm warning and the CO concentration is less than 250 PPM. The ALARM indicator still flashes the same way as the alarm warning, but the buzzer does not sound ,when in mute state. The duration of mute state not more than 10 minutes, and the higher the CO concentration ,and shorter the mute state. It will be recovered to alarm warning automatically, or it can be canceled the mute manually .If the Alarm exits the alarm warning due to the elimination of CO during the mute period, the mute will be end automatically.

The alarm warning must be operated without hazardous environment. If someone is repairing the gas appliance, which alarm warning caused by man-made that without hazard, or alarm warning caused by some peoples who are smoking together for a long time, etc. Only confirmed that environment without hazard, and can perform the mute operation of Alarm.

Mute operation of Alarm occurs during alarm warning, press the “TEST” button for 3 to 5 seconds that the ALARM indicator flashes ,but the buzzer no sound, and then release the button and enter the alarm mute mode. If keep pressing the “TEST” button and ALARM indicator flashes ,but the buzzer still sounds,it may because the CO concentration is higher than 250 PPM,and the mute function cannot be used.
If it is necessary to restore the alarm warning manually in the mute mode of alarm, press the “TEST” button again, when ALARM indicator flashes and the buzzer sounds that you can release the button.

Fault alarm and handling

Sensor fault alarm and handling
When the alarm works in the normal monitoring state, if the carbon monoxide sensor fails, the Alarm will issue fault warning about two and a half minutes at least. After

Low power alarm and handling
The Alarm is equipped with the function of battery power detection, which can detect battery power at least once a minute when in normal monitoring working state. If the battery voltage is detected below 2.2V ,a low-voltage warning sound will be issued, indicating that the battery will run out of power.

The battery power can only last for 7days from the low battery warning of Alarm. The product within a built-in disposable lithium battery, user can not replace the internal battery .Please replace a new Carbon Monoxide Alarm as soon as possible, when low power warning of Alarm.

The reason of shortening battery life of Alarm
The Alarm within a built-in disposable lithium battery of 3V 2400mAH, which can not be replaced by the user after the power exhaustion, and cause the service life of Alarm to end in advance. The internal battery power of Alarm can maintain the working voltage for more than 10 years, when in normal use. If Alarm often occurs warning of CO for a long time, and without management, or the manual test operation is frequently carried out, will cause the battery consumption faster ,and shorten the service life. Such as the owner is on business trip or travelling for a long time without any management. The Alarm that continuous hours or even days of CO warning, which power exhaustion, and cause the service life of Alarm to end in advance.

Key points :
When you hear the low power alarm, it indicates that the battery is about to run out of power and can only last for 7days of monitoring work. please replace the Carbon Monoxide Alarm in time.

Service life and end of life warning of Alarm

Service life of Alarm
The effective service life of Alarm is 10 years, which is equipped with a 10-year end of life warning function. When the Alarm is power on and enters the CO monitoring state, which work continuously for 16 days ,and will carry out time of life accumulation once, which can not be removed after permanent storage. When the accumulated time reaches 10 years, the
Alarm will issues the end of life warning to remind the user that the service life is expired, please stop using and replace the new Alarm in time.

End of life warning of Alarm
When the Alarm issues end of life warning, and at least once every minute issued by Alarm, which is described in instruction Since the calculation of Alarm life is based on 16 days of continuous operation as one time for storage. If power on and power off or other operations are carried out frequently in the process of use, which may cause the accumulated time of life error. Please do not turn off and turn on the Alarm at any time.
Pay attention to the manufacturing date of product, whether it has been used beyond the expiration date.
The product can not operate effectively and normally after the expiration date, please replace the product in time, and do not use the expired product.

Key points :
When you hear the Alarm issues two continuous sounds, that means the Alarm in fault or in end of service life, please replace the Alarm in time, and do not use the expired product.

Installation of carbon monoxide Alarm (KD-216LE)

Installation place
Install the Alarm in the bedroom or a popular activity place, or in the place where it is easy to produce CO, or may have CO leakage. To ensure that everyone can hear the sound where they sleep. It is recommended to install the Alarm on each floor of the multi-story building.

To make an ideal protection environment. Please avoid the Alarm damage or unnecessary alarm warning, and avoid Alarm not work when CO happened that harmful to human health. Please avoid the following places where are not for install CO Alarm:

  1. Do not install the Alarm in a closed space (such as the cabinet or behind the curtain)
  2. Do not install the Alarm in an obstructed place (such as behind the furniture )
  3. Do not install the Alarm on the floor or in the sink.
  4. Do not install the Alarm beside the door and window.
  5. Do not install the Alarm next to the fan, air conditioner vent, ventilation fan.
  6. Do not install the Alarm next to the vent and exhaust.
  7. Do not install the Alarm in a place where the temperature can drop to -10°C or exceed 40°C, unless you need to install it specially.
  8. Do not install the Alarm in a smoky, dusty place, which is easy to block the sensor of Alarm.
  9. Do not install the Alarm in a place where is too damp.
  10. Do not install the Alarm near the cooking utensil and cooking equipment.

Installation method
Please select the place where people can test and operate conveniently, when install the Alarm. If the Alarm is fixed on the wall ,the installation height must be more than 1.5M and lower than 0.3M from the ceiling, and 1.5 M away from the wall corner,wall edge, and furniture.

Installation procedure :

  • Use drilling tool to drill two installation holes with diameter of 6 MM and depth of 40MM on the wall where the Alarm is installed according to the distance and direction of “fixed mounting screw holes” on the “fixed mounting plate”
  • Insert the expansion plastic part for two fixing screws into the wall holes, and lock the “fixed mounting plate” with screws in the upward direction.
  • Turn on the power switch of the Alarm after the “fix mounting plate” has been installed. And test again according to the test method in “4.2 daily test”. If the test is normal, the Alarm can be buckled into “fixed mounting plate”, and the installation of the Alarm is completed.

Installation notes :

  • This Alarm with design of “switch remind function”, when the power switch is not turned on, it cannot be buckled into the ” fixed mounting plate”. Please do not force installation the Alarm,and avoid the Alarm damage.
  • If the Alarm is installed in the garage, do not install the Alarm near the exhaust of the car. When the car stars, it will emit higher concentration of CO, which may cause the Alarm issues alarm warning.

WARNING :
To ensure that Alarm can be installed and used correctly, it must be installed in accordance with instruction manual or by professional personnel.

Daily maintenance and notes
  1. Other chemical gases influence on the Alarm :
    Alarm can not only reaction of CO, also can cause false alarm and damage to the sensor, by the following chemicals:
    Methane, propane, isobutane, ethylene, ethanol, alcohol,isopropanol, benzene, toluene, ethyl acetate, hydrogen,hydrogen sulfide, sulfur dioxide. Almost all aerosol sprays,alcohol preparations, paints, thinners, solvents, adhesives,aftershave, perfumes, automobile exhaust (cold start) and cleansers. When the Alarm is polluted and damaged by the above high concentration of chemical gas. The sensor of the Alarm may be damaged ,and causing temporary false alarm or permanent damage. When the Alarm occurs alarm, and near the strong smell of chemical gas can be smelled, which may be a false alarm. Because CO is colorless, and odorless, while chemical gas is usually with strong smell. The Alarm can be taken to the fresh air for 30minutes when false alarm of chemical gas happened. If still not exit the alarm state, which indicates that the Alarm has been polluted by chemical gas. The Alarm should be power off, and taken to the fresh air without pollution,which may be recovered gradually. If the Alarm has not been
    recovered after 24 hours in the air, which the sensor has been damaged. Please do not use the Alarm anymore.
    Key points :
    After the Alarm is polluted by other chemical gases. Please do not use the Alarm anymore which has not been recovered after 24 hours in the air.

Cleaning and maintenance of Alarm :
The Alarm must be kept clean in use, and maintained once a month. Otherwise the detection performance will be affected and the Alarm may be damaged. Maintenance methods are as follows:

  1. Please use a vacuum cleaner to remove the dust from the surface of the Alarm if the dust is visible on the surface.
  2. Please wipe the surface of Alarm lightly with a wet cloth.
  3. Please press the “TEST” button once again after the cleaning.
    It can be reinstalled and use after test is normal.

Do not use alcohol, gasoline, cleanser and other chemicals to clean the Alarm, which in the process of maintenance and cleaning. Otherwise it may cause damage to the Alarm.

Key points :
The Alarm shall be cleaned and maintained once a month.
It is prohibited to clean the Alarm with chemical cleansers.

Frequently asked questions(FAQs) and notes :

  • Do not spray chemical aerosols such as air fresheners, hair spray, perfume, insecticide, and spay paint near the Alarm.
  • Please do not brush paint and pigment on the Alarm. Please put Alarm in the clean plastic bag, when painting the wall paint and floor paint. And then install it again after the smell of the paint is completely evaporated.
  • Do not block or cover the vent hole of the Alarm with adhesive tape or other things.
  • If the Alarm drops on the floor, please pick it up and check whether the battery has been dropped or loosen. After make sure the battery is intact, press the “TEST” button again to test whether the function is normal. Then install Alarm again after the function is normal.

The harm of disassemble and modify, repair Alarm without authorization

The gas data of Alarm has been calibrated at the factory. If the shell is disassembled and any component parameters or control software of Alarm are modified without authorization in the use or maintenance, which may cause Alarm data may be deviated or missing, and lead to Alarm issues error alarm warning, and become invalid and fault. Therefore, any components and programs shall not be disassembled and modified without authorization.

WARNING:

Any components and programs of Alarm shall not be disassembled and modified without authorization in service life. Otherwise, it may cause the Alarm invalid.

Additional instructions

Recognition of carbon monoxide
Carbon monoxide is a kind of colorless, odorless, and deadly toxic gas which is produced when any combustible materials burns.
Higher concentration of CO will be produced when materials are burned in the air with limited space. When people breathe in a certain amount of CO, who will cause poisoning and death. The Consumer Product Safety Committees of many countries have warned the public, that the harm of deadly household gases, and make carbon monoxide poisoning as the first public safety problem.

How is carbon monoxide produced
In the home that the carbon monoxide produced by heating and burning, which main sources are kitchenware, heating and heating device. Such as stove, water heater, fireplace, wood stove carbon grill, natural gas cage, heating device, micro generator etc. In the garage that carbon monoxide is emitted from engine when the car is started.
When devices are in well-ventilation and normal working state,the CO will be produced very little, and will be discharge to the outside of the house soon, and will not harm to the human body.
However, when the indoor oxygen is insufficient and burning is insufficient, or the device fails, the higher concentration of CO will be emitted, which due to poor ventilation that the air flow speed will be not distributed quickly, and will be accumulated to harm human health.

Effects of carbon monoxide on human health
Carbon monoxide is a kind of colorless, odorless, and non-irritating gas, which is classified as chemical asphyxiant, and the direct manifestation of carbon monoxide poisoning is hypoxia.

When people inhale carbon monoxide, which will be quickly absorbed through the lung, and spread through the alveolar capillary membrane in the blood, and combing with hemoglobin to form COHb (carboxyhemoglobin, this process is reversible).
But there is a small amount of CO in the plasma. The hemoglobin

Table A.1 Healthy adults –the effects of COH blood concentration on healthy

LIORQUE-KD-216LE-Carbon-Monoxide-Detector-10-Year-Battery-FIG-
\(2\)

There are many other forms and papers on this topic. The article of The American Department of Health, education and welfare mentions when concentration of COHb is 3%, the perceptible visual acuity will be impaired. Recently, Kleinman et suggested that the normal subjects who exercise endurance decreased after receiving a dose of 100 ppm carbon monoxide for one hour.

Chronic effects on high risk groups
People with coronary artery disease who exposed in low concentration of carbon monoxide environment will reduce their ability to exercise. Those sick who exposed in the low CO concentration can speed up exercise-induced angina. Carbon monoxide can cross the placental barrier and cause harm to the normal development of the fetus.

Due to organ problems or special changes, many high-risk groups are sensitive to carbon monoxide. The high-risk groups are as following:

  • People with reduced oxygen carrying capacity due to anaemia or other hemoglobin diseases;
  • People who have a fever hyperthyroidism, and pregnancy need more oxygen;
  • People who lack of oxygen due to lack of breath;
  •  People who have heart disease, vascular insufficiency. Such as brain hypoxia and peripheral vascular disease.

Normal COHb concentration
In normal condition, the concentration of COHb is very low in human body, from 0.3% to 0.7%, which cannot be consider harmless to the human body.

Smoking
The CO concentration of smokers is very high, which changing from 5% to 9%, and people who smoke cigar may be over 10%.

Early symptoms of carbon monoxide poisoning :
It is usually headache, have blurred vision, fatigue, nausea,vomiting, sleepiness, disorientation, and flu-like symptoms should be aware that may be caused by carbon monoxide poisoning. The symptoms will be improved after they leave or after a long time but will be not disappeared.
Inhaling a high concentration of carbon monoxide can be deadly in a few minutes, also inhaling a low concentration of CO for a long time is dangerous. Long-term expose in the low concentration of CO can cause permanent damage to the heart and brain.

The harm of carbon monoxide to the family
According to some clinical records, the death rate caused by carbon monoxide poisoning ranks first among all kinds of poisoning death in the united states. At least 10,000 Americans are harmed by CO poisoning every year.
Everyone may be more or less affected by carbon monoxide in daily life. But experts say unborn babies, children, elderly and people who have heart or respiratory disease are weaker to resist carbon monoxide. They are more easily to be death or serious harm caused by carbon monoxide.

For health and safety, you need to know the source of carbon monoxide that may be produced in home. The chimney and vent of kitchenware and equipment in use shall be kept in a good and unblocked condition. Please use burner equipment correctly, do not use burning and high heat appliance in the closed airtight room, and narrow airtight bathroom. Maintain and check gas appliances and gas supply systems regularly. Such as cracks in the heat exchanger in the stove, gas leakage from the vent exhaust of the water heater, or nest of bird blocking the flue, etc,which may cause the carbon monoxide.
In addition to the use of the burner, you should also know more about the early symptoms of carbon monoxide poisoning. If you suspect yourself by carbon monoxide poisoning, evacuate to the outside and ask for urgent help. Blood test is the most correct way to determine whether it is CO poisoning
Please use the Carbon Monoxide Alarm correctly, let you know the harm of existence carbon monoxide earlier, and manage or evacuate in time to prevent the CO poisoning.

The harm of carbon monoxide to the family

WARNING :
The Carbon Monoxide Alarm is used to remind people the existence of carbon monoxide, which people can manage and evacuate in time. However, it can not prevent the leakage of carbon monoxide.

Poisoning symptoms of carbon monoxide

  • Common mild symptoms :
    Slight headache, nausea, vomiting, fatigue.

  • Common moderate symptoms:
    Headache, drowsiness, confusion, tachycardia

  • Common severe symptoms :
    Spasm, unconsciousness, cardiopulmonary failure, that can cause brain damage and death.

Poisoning symptoms of carbon monoxide concentration :

LIORQUE-KD-216LE-Carbon-Monoxide-Detector-10-Year-Battery-FIG-
\(8\)

LIORQUE-KD-216LE-Carbon-Monoxide-Detector-10-Year-Battery-FIG-
\(9\)

Attention: The symptoms of CO poisoning in the above list are for healthy adults. As for high-risk groups that the response is different.

Treatment of carbon monoxide poisoning
Anyone who is suspected of carbon monoxide poisoning should evacuate the area with potential risk of CO immediately, and breathe fresh air and go to the hospital for examination. Carbon monoxide poisoning can be determined by blood test of carbon monoxide hemoglobin test, which can check the amount of CO in blood. For test accurately, which must be checked immediately after inhale of carbon monoxide. Acute carbon monoxide poisoning is usually treated by oxygen uptake. When the poisoning is severe (such as unconsciousness), who should be treated in the hyperbaric oxygen room, which needs to be treated by the doctors.

How to deal with harmful CO or warn of CO Alarm
Please know some common sense of carbon monoxide, and know how to determine whether the family members have symptoms of CO poisoning. Many reports of carbon monoxide poisoning point out that when the victims realize the situation is not good, they are already unconsciousness, lost sense of direction to escape from the house or call for help. Children or elderly are the first to be affected.
When you and your family have symptoms that described in article 5 of this chapter (Poisoning symptoms of carbon monoxide), you should consult the doctor immediately, though it is a mild symptom.

WARNING :
Carbon monoxide is a kind of a toxic gas that can be deadly.
When Carbon Monoxide Alarm warns that means a dangerous situation of CO has occurred.

Since carbon monoxide can be deadly. The following measures shall be done, if Carbon Monoxide Alarm warns:

  1. Shut down the burning appliances, heating devices, and all devices that can produce and discharge carbon monoxide immediately. Please open the door and window, exhaust ventilation device, and other air supply system.

  2. Inform personnel immediately to the outside safety area with fresh air, and count the number of people. Call or other ways ask for help from First Aid Agency, and wait for first aid personnel arrive to ventilate the house, and remove the source of danger.
    The professional personnel who do not wear oxygen supply and anti-toxic equipment must not enter the house again, before the Alarm exits the alarm state.

  3. If there has been a leakage of carbon monoxide and has been removed professionally, the Alarm will warn again with 24 hours, then repeat previous steps again, and a qualified professional technician is required to investigate the burning, heating, and all devices that can produce carbon monoxide ,and whether the exhaust ventilation system operates normally. If finding problems in the inspection, stop using immediately, and ask for qualified organization or professional technician to repair the device.

For the safety and health of you and your family. Please learn more about symptoms of carbon monoxide poisoning and prevention, treatment of common sense. Minimize the harm of CO to you and your family, and the surroundings.

List of accessories

Products are delivered with the following accessories:

No. Accessory Name Quantity
1 KD-216LE lPC
2 Mounting board lPC
3 Mounting screw 2PS
4 Mounting plastic expansion 2PS
5 Instruction manual lPC

This instruction is very important for you to use the product correctly, please read carefully and keep it well. If the product is damaged or invalid due to human factors, our corporation will not take any responsibility.

Ningbo Kingdun Electronic Industry Co., Ltd.

Address: No.28 Fengyuan Rd, South of Economic Develop-
ment Area, Yuyao City, Zhejiang, China
Tel: 0574-62566038

UK Importer:HISOA CO., LTD.
Address:19a Chorley Old Road, Bolton,Greater Manchester, England, BL1 3AD
Web:www.hisoa.co.uk
EU Importer:Lucky Iransport Euro Krt
Address: 1085 Budapest, Josef Central Street 69. Ground Floor, 1, Hungary
Emait:Lsphche@outlook.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals