SAUER-SUNDSTRAND MCE123A Auxiliary Controller Instruction Manual
- May 15, 2024
- SAUER-SUNDSTRAND
Table of Contents
- SAUER-SUNDSTRAND MCE123A Auxiliary Controller
- Specifications
- Product Description
- Features
- Technical Data
- Theory of Operation
- Dimensions
- Connection Diagram
- Product Usage Instructions
- Frequently Asked Questions (FAQ)
- DESCRIPTION
- FEATURES
- ORDERING INFORMATION
- TECHNICAL DATA
- BLOCK DIAGRAM
- THEORY OF OPERATION
- DIMENSIONS
- CONNECTION DIAGRAM
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SAUER-SUNDSTRAND MCE123A Auxiliary Controller
Specifications
- Product Name : MCE123A Auxiliary Controller
- Model Number : MCE123A1001, MCE123A1002
- Supply Voltage: 24VDC
- Frequency Range: 200Hz – 700Hz, 253Hz – 380Hz
- Output Current: 60mA – 100mA, 30mA – 100mA
Product Description
The SAUER-SUNDSTRAND MCE123A Auxiliary Controller provides a reverse proportional control signal to the Electrical Displacement Control (EDC) in open loop. The output signal is proportional to the measured frequency input from a speed sensor, and it decreases with increasing speed.
Features
- Proportional control signal
- Reverse proportional output with speed increase
- Designed for open-loop operation
Technical Data
- Supply Voltage: 24VDC
- Ripple: 20%
- Output Current: See ordering information
- Frequency Range: See ordering information
Theory of Operation
The MCE123A converts frequency signals to proportional DC voltage. The output current value is reverse proportional to the frequency signal based on an adjustable control characteristic.
Dimensions
Insert dimensions information here…
Connection Diagram
Insert connection diagram information here…
Product Usage Instructions
- Connect the MCE123A Auxiliary Controller to the Electrical Displacement Control (EDC) using the provided connection diagram.
- Ensure the supply voltage is 24VDC.
- Adjust the control characteristic for the desired output current based on the frequency signal.
- Monitor the output signal to ensure it is reverse proportional to the frequency input from the speed sensor.
Frequently Asked Questions (FAQ)
-
Can I use a different supply voltage with the MCE123A Auxiliary Controller?
No, the MCE123A requires a supply voltage of 24VDC for proper operation. -
How do I adjust the control characteristic of the MCE123A?
The control characteristic adjustment is detailed in the product manual. Refer to the manual for specific instructions.
DESCRIPTION
- The SAUER-SUNDSTRAND MCE123A Auxiliary Controller provides, in open loop, a “reverse proportional” control signal to the Electrical Displacement Control (EDC). This signal is proportional to the measured frequency input to the Controller from a speed sensor.
- The Controller is designed so that with increasing speed, the output is reduced
FEATURES
- Easy adjustment
- Available with enclosure
- Reverse polarity and short circuit protected
- Withstand vibration and shock
ORDERING INFORMATION
Controller| Supply voltage [V DC ]| Frequency
range [Hz]| Output current [mA]| Id. No.
---|---|---|---|---
MCE123A1001| 24| 200 – 700| 60 – 100| 303 750
MCE123A1002| 24| 253 – 380| 30 – 100| 710 962
TECHNICAL DATA
- SUPPLY VOLTAGE 24VDC
- RIPPLE 20%
- OUTPUT CURRENT see ordering information
- FREQUENCY RANGE see ordering information
BLOCK DIAGRAM
THEORY OF OPERATION
- The electronic MCE123A converts the frequency signal to a proportional DC voltage.
- Depending on an adjustable control characteristic (see figure 1) the output current value is “reverse proportional” to the frequency signal.
DIMENSIONS
CONNECTION DIAGRAM
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>