Altronix RBR1224 Electronic Toggle Ratchet Relay Instruction Manual
- June 4, 2024
- Altronix
Table of Contents
Altronix RBR1224 Electronic Toggle Ratchet Relay
Specifications
- 12VDC to 24VDC operation.
- Positive (+) or negative (–) ultra sensitive trigger (3VDC to 24VDC @ 20mA minimum).
- DPDT contacts rated at 2A/120VAC/28VDC.
- Relay status LED.
- Remote LED status output.
- Snap track mountable (order part # ST3). Board dimensions (W x L x H): 2.5”x 3” x 1” (63.5mm x 76.2mm x 25.4mm)
DIMENSION
Applications
- Use with PGM alarm control panel outputs.
- Electronically shunt-alarm zones,door control or keypads.
- Interfaces with wireless receivers.
- Converts momentary to maintained contacts.
Installation Instructions
- Connect aux power to terminals marked [POS (+)] and [NEG (–)].
- The relay will change state to latch ON or OFF by the application of a positive momentary trigger voltage to the terminals marked [TRG +] and [POS (+)] or negative momentary trigger voltage to terminals marked [TRG –] and [NEG (–)].
- Relay status LED is lit when relay is energized. To use a remote LED, connect negative lead of remote LED to terminal marked [LED], connect positive lead of LED to [POS (+)].
Altronix is not responsible for any typographical errors. Product
specifications are subject to change without notice.
140 58th Street, Brooklyn, New York 11220 USA
phone: 718-567-8181
fax: 718-567-9056
website: www.altronix.com
e-mail: info@altronix.com