K KERNOWO AE561D Soldering Iron User Manual

May 15, 2024
K KERNOWO

K KERNOWO AE561D Soldering Iron

Product Specifications:

  • Software Version: vxx

Product Usage Instructions

  1. Locating Software Version:
    • Press the menu button on the device to access the menu.
    • Navigate to the ‘Software Version’ option in the menu.
    • Select the ‘Software Version’ option to view the version number displayed as ‘vxx’.
  2. Exiting Menu:
    • While in the menu, press and hold the ‘o’ key on the device.
    • The device will exit the menu and return to the previous screen or function.

FAQs

  • Q: How do I check the software version of the product?
    A: To check the software version, navigate to the menu and select the ‘Software Version’ option.

  • Q: How do I exit the menu on the device?
    A: Press and hold the ‘o’ key while in the menu to exit and return to the previous screen.

Safety and Precautions

The precautions in this manual are divided into the following [warning] and [attention).

Warning: misuse may cause death or serious injury to the user.
Note: misuse may cause injury to users or substantial damage to objects involved.

For your own safety, please strictly abide by the following precautions

Warning
When power is on, the temperature of the soldering iron tip might reach to 200 ~ 500 °C (392 ~ 932°F). Misuse may cause burns and fire, please strictly observe the following precautions:

  • Do not touch the soldering iron tip or the metal part around it while using.
  • Do not use it around combustibles.
  • Potential high temperature risk should be warned.
  • Turn OFF the power when not in use.
  • Before replacing parts or tip, turn off the power and wait till the iron tip cools down.
  • Do not use this product without the permission of the responsible person if you are inexperienced and lack knowledge (including children).
  • Please keep children away from this product.
  • If the power cord is damaged, please ask the manufacturer or its service agent or similar qualified personnel to repair it, so as to avoid personal injury or damage to product.

Product Specification

  • Model No.: AE561D
  • Total Power: 120W
  • Temperature range: 200 – 500°C(392-932°F)
  • Temperature stability: +2°C (conditions: no-load, static state)
  • Temperature accuracy: #15°C
  • Cable length: 1.4m

Instructions

Power On:
Digital display shows 1s of all digits, then 1s of “SLP” if standby sleep function is enabled. Then, it enters sleep mode or work mode according to the previous setting.

Temperature Lock Function:

  1. Press and hold the “o” key to enter the menu.
  2. Press “+”/”-” to switch the menu option, press “o” to confirm to enter the “LOC” setting interface.
  3. Press “+”|”-” to toggle “on”/”off”, long press Press and hold the “o” key to confirm the selection of “on” to turn on the temperature lock function; or press and hold the “o” key to confirm the selection of “off” to turn off the temperature lock function.
  4. Select “on” to turn on the temperature lock, enter the interface of setting the lock temperature, press the “+”|”-” key to set the temperature to be locked, long press the “o” key to confirm and return to working mode. At this time, the temperature cannot be adjusted and “LOC” is displayed when adjusting.
  5. Select “off” to switch off the temperature locking mode, long press the “o” key to confirm and return to the operating mode. The temperature can then be adjusted. The set temperature can be adjusted by a short press of “*”/”-“, or a long press for quick adjustment. The temperature adjustment range is 200-500°C (392-932°F).

Standby Sleep Function:

  1. Press and hold the “o” key to enter the menu.
  2. Press “+”/”-” to switch the menu option, press “o” to confirm to enter the “SLP” setting interface. Long press the “o” key to select “on” to turn on the auto-sleep function; or long press the “o” key to select “off ” to turn off the auto-sleep function.
  3. After 10 minutes of no action after the auto-sleep function is turned on, it will enter standby (temperature down to 250℃) and return to working mode when action is detected; standby lasts for 10 minutes, it will enter sleep and turn off heating, short press “o” key to return to working mode.

Unit Switching Function:

  1. Long press the “o” key to enter the menu.
  2. Press the “+” / “-” key to switch the menu options, long press the “o” key to confirm to enter the “UNT” setting interface.
  3. Toggle between Celsius and Fahrenheit with the “+” / “-” keys. Long press the “o” key to confirm and return to the working mode. The unit in the display are the set unit.

Temperature Compensation Function:

  1. Press and hold the “o” key to enter the menu.
  2. Press “+”/”-” to switch the menu option, press and hold the “o” key to confirm and enter the “CAL” setting interface.
  3. In the menu “CAL”, enter the compensation value as follows
    • a. Press “+”/”-” to adjust the setting temperature to 350℃ (662℉), wait 2 minutes for the temperature to stabilize.
    • b. Use a thermometer to measure the soldering iron tip temperature, e.g. 340°C.
    • c. Enter the compensation based on the calculated difference, as in the above example, 10°C lower than actual, then enter the compensation value as +10°C.
  4. After setting the compensation value, long press the “o” key to confirm and return to working mode.

Software Version:
“vxx” in the menu is the software version number, select and press and hold the “o” key to exit the menu.

T900M series soldering tips

K-KERNOWO-AE561D-Soldering-Iron-1

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>