SCON XTB106 4 Wire Ceiling Surface Mounted Magnetic Track Lighting System User Manual

May 15, 2024
SCON

SCON XTB106 4 Wire Ceiling Surface Mounted Magnetic Track Lighting System

SCON-XTB106-4-Wire-Ceiling-Surface-Mounted-Magnetic-Track-Lighting-System-
PRODUCT

Notice Read the user manual carefully before using SCON-XTB106-4-Wire-
Ceiling-Surface-Mounted-Magnetic-Track-Lighting-System-
\(1\) Important Safety Information

WARNING

  • Be sure the electricity to the wires you are working on is shut off; either the fuse is removed or the circuit breaker is turned off.
  • Do NOT install or use the light fixture if any part is missing or damaged. Contact your dealer for replace­ment or missing parts.

IMPORTANT SAFETY INSTRUCTIONS

  • Do NOT install this track system in damp or wet locations
  • Do NOT install any part of a track system less than 5 feet above the ftoor.
  • Do NOT install any luminaire assembly closer than 6 inches from any curtain, or similar combustible material.
  • Shut off the electrical power before adding to or changing the configuration of the track system.
  • Do NOT attempt to energize anything other model’s track lighting luminaires on the track.
  • To reduce the risk of fire and electric shock do NOT attempt to connect power tools, extension cords, appliances, and the like to the track.
  • Due to the complexity of the lighting system, a qualified electrician is needed.
    Although the track lighting system may seem to operate acceptably, a dangerous overload of the neutral may occur and result in a risk of fire

CAUTION

  • HOT SURFACE! The track luminaire is hot when the power is on, wait at least 5 min to touch it after the power is off.
  • SCON XTB106 track is only available for SCON XTB106 lights and vice versa.
  • A driver can power 12 meters connected tracks at most, and the total wattage of connected tracks in group can’t exceed 300W.

ATTRIBUTION

  • Main Material: Aluminium
  • Surface treatment: Anodizing Aluminium
  • Working Temperature: ta: -20~50°C; tc: 75°C
  • Environmental Relative Humidity: 20%~85%
  • Waterproof Class: IP20 (Track) /IP40 (Light)
  • Output Voltage of Track: 48Vdc
  • Input Voltage of Track Lighting Head: 48Vdc
  • 3 dimming methods: 0-10 V (only dimming), DALI with dimming, DALI with dimming and adjusting CCT (2700K-6500K).

Structure of the System

SCON XTB106 recessed magnetic track lighting system must have these components:

  1. Power Driver / Transformer
    You ·must have at least one You must have at least one power driver supplied by SCON.

  2. Track & Rail
    To link the tracks with the power driver, you must have at least one track .Tracks can be easily connected to each other to make your favorite scheme of lighting.

  3. Corner Joint
    With corner joints, the tracks can be formed into various routes.

  4. Track Lighting Head
    Once the track is installed, you can choose from a wide variety of lamp heads to design your own lighting system.

  5. Dimmer Switch and Related
    If you need a dimmable system, selecting the corresponding LED driver and dimmer switch is necessary. DALI dimming method needs DALI bus power supply, and DALI with multi-CCT method needs the corresponding track lighting heads specially.

Components of the System

LED Power Driver

  • LED Driv1er A for N1on-Dimmable System or DALI with Multi-·CCT Syst1em
  • LED Driver B, for TR?AC/EILV System 10r 0-101·v Sys:tem SCON-XTB106-4-Wire-Ceiling-Surface-Mounted-Magnetic-Track-Lighting-System- \(23\)
  • LED Driver C for DALI with Mono-CCT System SCON-XTB106-4-Wire-Ceiling-Surface-Mounted-Magnetic-Track-Lighting-System- \(24\)

Driver B and C is special designed for SCON XTB106 sys;tem,, and the 0ther driver can t b,e compatible with  SCON XTB.1016 TRIAC/ELV 0-1 ov DALI with Mono·-CCT l  s,ysltem.

Track Sectional Drawing SCON-XTB106-4-Wire-Ceiling-Surface-Mounted-
Magnetic-Track-Lighting-System- \(25\)

  • Supports both non-dimmable and dimmable system TRIAC/ELV, 0-10V, DALI (Mono-CCT or Multi-CCT) dimming methods; but different dimming methods can not be mixed in one system.

Track & Rail

Track – Built-in 30W DriverSCON-XTB106-4-Wire-Ceiling-Surface-Mounted-
Magnetic-Track-Lighting-System- \(26\) Notice: This type of track can only be surface spliced together without allowing the circuit to be connected.

SCON-XTB106-4-Wire-Ceiling-Surface-Mounted-Magnetic-Track-Lighting-System-
\(27\) Notice: This type of track can only be surface spliced together without allowing the circuit to be connected.

48V Track Lighting Heads
Comments: A)3000K-Warm White; 4000K-Natural White; 5000K-Daylight. B) The bold font value in beam angle is the default. C) Two types of XTB106 track lighting heads: 1) No built-in dimmable driver but is compatible with non-dimmable system, TRIAC/ELV system, 0-10V system, DALI Mono-CCT system. 2) with built-in dimmable driver and is compatible with DALI Multi-CCT system.

Linear Floodlight

SCON-XTB106-4-Wire-Ceiling-Surface-Mounted-Magnetic-Track-Lighting-System-
\(28\)

Power LWH(mm) Beam Angle CCT Color
10W 263 33.540 90°
  • 2700K
  • 3000K
  • 4000K
  • 5000K

| Black
White
15W| 40233.540
| | | 2700K-6500K|

Linear Spotlight

SCON-XTB106-4-Wire-Ceiling-Surface-Mounted-Magnetic-Track-Lighting-System-
\(29\)

Power LWH(mm) Beam Angle CCT Color
**** 10W *** 263 33.5*40 **** 15°

30 °

45°

|

  • 2700K
  • 3000K
  • 4000K
  • 5000K

| Black
White
15W| 40233.5 40
| | | 2700K-6500K|

Anti-Glare Floodlight SCON-XTB106-4-Wire-Ceiling-Surface-Mounted-
Magnetic-Track-Lighting-System- \(30\)

Power

10W

| LWH(mm)

263 33.540

| Beam Angle

I- 90°

| CCT

–                        –

  • 2700K
  • 3000K
  • 4000K
  • 5000K
  • 2700K-6500K

| Color

Black

White

---|---|---|---|---
15W| 40233.5 40

Pendant Spotlight

SCON-XTB106-4-Wire-Ceiling-Surface-Mounted-Magnetic-Track-Lighting-System-
\(31\)

Pendant Ball light SCON-XTB106-4-Wire-Ceiling-Surface-Mounted-Magnetic-
Track-Lighting-System- \(32\)

Dual Spotlight SCON-XTB106-4-Wire-Ceiling-Surface-Mounted-Magnetic-
Track-Lighting-System- \(32\)

Power LWH(mm) Beam Angle CCT Color
**** 18W *** 29140.*130 **** 15°

2 4 °

40°

| 2700K

3000K

4000K

5000K

| **** Black

White

| | | 2700K-6 500K|

Downlight

SCON-XTB106-4-Wire-Ceiling-Surface-Mounted-Magnetic-Track-Lighting-System-
01

  • XTB106 track lighting heads can’t be compatible with XTB028; vice versa.
  • More types of XTB106 track lighting heads are listed in SCON store.

Steps of Installation

Assemble the Hanging Wire

  1. Fasten the Eyelets Terminals SCON-XTB106-4-Wire-Ceiling-Surface-Mounted-Magnetic-Track-Lighting-System- \(35\)

  2. Tighten the Locking Screws with Hanging Wire Surface Mounted Installation

  3. Fasten the Siding to the CeilingSCON-XTB106-4-Wire-Ceiling-Surface-Mounted-Magnetic-Track-Lighting-System- \(37\)

  4. Fasten Track to the Surface

  5. Open the End Cap

  6. Surface Mounted the Track and Connect the Wire (The input voltage of built-in driver track is 48V DC, and non built-in driver track is 110V/220V AC)

  7. Close the End Cap

Connect Tracks

SCON-XTB106-4-Wire-Ceiling-Surface-Mounted-Magnetic-Track-Lighting-System-
\(41\)

  1. Push the Two Rails Tightly Together and Attach the Clasp
  2. Plug In the Wire Connectors

Power Off and Connect the Driver
( for the type of non-built-in 30W driver track)

Different dimming methods and different dimming control programs will lead to different installation methods. A professional electrician for the installation of intelligent lighting systems is a necessity.

No Dimming Wiring Diagram

SCON-XTB106-4-Wire-Ceiling-Surface-Mounted-Magnetic-Track-Lighting-System-
\(42\)

TRIAC/ELV Wiring Diagram

SCON-XTB106-4-Wire-Ceiling-Surface-Mounted-Magnetic-Track-Lighting-System-
\(42\)

0-10V Wiring Diagram

SCON-XTB106-4-Wire-Ceiling-Surface-Mounted-Magnetic-Track-Lighting-System-
\(44\)

DALI (Mono-CCT) Wiring Diagram

SCON-XTB106-4-Wire-Ceiling-Surface-Mounted-Magnetic-Track-Lighting-System-
\(45\)

DALI (Multi-CCT) Wiring Diagram

SCON-XTB106-4-Wire-Ceiling-Surface-Mounted-Magnetic-Track-Lighting-System-
\(46\)

Power On and Test the Track SCON-XTB106-4-Wire-Ceiling-Surface-Mounted-
Magnetic-Track-Lighting-System- \(47\)

If there are recessed buttons at the track lighting head’s both ends, press the 2 buttons with both hands at the same time and put the light into the track.

Pendant or Surface MountedTrack Lighting Scheme

SCON-XTB106-4-Wire-Ceiling-Surface-Mounted-Magnetic-Track-Lighting-System-
\(48\)

Single Pendant Magnetic Track Lighting

SCON-XTB106-4-Wire-Ceiling-Surface-Mounted-Magnetic-Track-Lighting-System-
\(49\)

SCON-XTB106-4-Wire-Ceiling-Surface-Mounted-Magnetic-Track-Lighting-System-
\(49\)

Groups of Surfaced Mounted Magnetic Track Lighting

Tips & Troubleshooting

  • Q: Can I use the driver provided by other sellers?
    A: If you do not choose to use the driver provided by SCON, then you must ensure that another driver of your own choice provides the compatible parameters with SCON driver. But we strongly recommend that using the driver provided by SCON, otherwise the system may not work.

  • Q: Is the new version XTB106 track compatible with the old version?
    A: Yes. The new version no longer distinguishes between with cable and no cable, making it easier for you to order tracks.and the 4 wires cable is easy to get on common market. An important reminder is that 80mm (3.15″) of height space needs to be reserved for the installation of the track. Under the new track lighting system solution, the non-dimmable lamp head can be dimmed through the TRIAC, 0-10V, or DALI (mono-CCT) dimming driver, which is more convenient. However, the multi-CCT dimming system needs to choose the lamp head with built-in DALI dimming driver, and the external driver connected to the system does not need to have dimming features.

  • Q: Can I cut the track to meet my needs of track length?
    A: You can cut the track to match the designed length. It is recommended to cut to a maximum of two sections. If cut in three or more sections, only the head and tail sections can be used, as only the head and tail sections have connectors for in serting pins to connect to other tracks.

There is no terminal blocks in the middle of the track, so when the track is cut from the middle, the new formed track tail or head cannot be connected and energized again, but can only be used as the tail of the new track system. SCON-XTB106-4-Wire-Ceiling-Surface-Mounted-Magnetic-Track-Lighting-System-
\(49\)

*The terminal blocks only be fixed in the tail and head of the track, so the tracks can be connected by pin header connector.

  • Q: How to assure the warranty of tracks?
    A: 3 years manufacturer warranty for all SCON products. After many years, if the track fails to power up, we can provide special bridging lights to connect the track circuit without dismantling the track.

  • Q: How to solve the problem of lighting ftickering?
    A: If the light is fiickering, it is most likely because there is a problem with the driver or its connection. If there is a problem with the light, the light will only come on or not.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals