EIBOS CYCLOPES Filament Dryer User Manual
- June 17, 2024
- EIBOS
Table of Contents
User Manual
[Filament Dryer——CYCLOPES] “Please read the manual carefully before
using, and keep it properly. Package contains the following products:
Before Using
- DO NOT insert the power cord into the socket, when the product is not being used.
- DO NOT touch the heating hole directly in order to avoid scald.
- When unattended, please cut off power supply, to prevent accidental fire.
- When the product malfunction, please cut off power and contact with Eibos or the distributor, do not try to fix it yourself.
- Pictures and illustrations in this user manual may be inconsistent with the actual product.
- Eibos is not responsible for any direct or indirect damages caused by product operation and modification, and any accidents caused by user inattention.
- This user manual can be modified without any prior notices.
Product Description
Product Parameter
Input Voltage: AC 110V / 220V 50/60Hz
Rated Power: 100W
Temperature Control Range: <70°C
Product Size: 213x280x305mm Net Weight: 1.5kg
Package Size: 245x305x355mm Total Weight: 2.3kg
Timing Length: Tmin~24h or unlimited
Precision of Temperature Control: +2°C
Maximum Capacity: Double Reels Φ 217x80mm/
Single Reel Φ217x174mm
Filament Diameter: 1.75mm
Installation Procedure
- Install roller racks on the base
- Install Teflon tube on the cover
- Check input voltage
- Put in filament, Adjust the silicone clamp
(leave the gap between the spools for better heating)
Control Panel Instruction
Method of Operation
Connect the power cord, then click the on-off button , the screen light with
turn on. The temperature will be displayed on the upper part of the screen,
while the rest of the heating time will be displayed on the lower part of the
screen.
[Temperature Setting] Click the temp button , the upper part of the
screen will flash, then click the increase button or the decrease button to
set the target temperature, the temperature range from 0°C to 70°C. Then click
the temp button again to
finish the temperature setting.
[ Timing Setting ] Click the timing button , the first two numbers on the
lower part of the screen will flash, which can be used to adjust the remaining
heating hour, it ranges from 0 to 24 hours. When you increase the number based
on 24, it will turn into the unlimited timing status, will be displayed on the
screen. Click the temp button again to adjust the timing minute, it ranges
from 0 to 59 minutes. Then click the timing button again to finish the timing
setting.
[Attention] The measured temperature is the temperature of the area where the sensor is located, not the temperature of anywhere in the machine.
Recommended Settings
Filament | temperature | Time |
---|---|---|
PLA | 50°C | ≥4h |
ABS | 60°C | ≥2h |
PETG | 65°C | ≥2h |
Nylon | 70°C | ≥12h |
PC | 70°C | ≥8h |
TPU | 55°C | ≥4h |
PVA | 50°C | ≥4h |
ASA | 60°C | ≥4h |
PP | 55°C | ≥6h |
*The data above is for reference only. The actual printing result are subject to real situation.
*The data above is obtained by EIBOS laboratory testing ( PA-CF, 70°C) and the data is for reference only.
After-sales Service Card
Shenzhen EIBOS Chuanggou Tech Co. Ltd
Username|
---|---
Contact number|
Address|
Product Model| CYCLOPES
Production Number|
Invoice Number|
Distributor|
- As a product warranty certificate, this card should be kept properly by customer. Do not change anything on this card.
- From the date of purchasing, if any non-artificial malfunctions occur, this product can be returned within 7 days, and can be changed within 15 days, with 1 year paid warranty.
- Malfunctions or damages caused by self-disassembly or improper use or any other personal reasons are not included in the scope of the warranty.