Please read the instructions fully before attempting installation.

OP-TSWF01 Wall Mounted Wifi Timer Switch

IMPORTANT
This unit should be installed to current IEE wiring regulations.

  • Timer must not be mounted on a flammable surface.
  • Ensure that the timer does not come into contact with any combustible material such as towels or bedding.
  • Ensure at least a 300mm airspace is allowed around the timer.
  • The timer should not be mounted on an unearthed metal or metallised surface.
  • If the timer is to be connected to an appliance that is required to be earthed. The supply earthing conductor and the appliance earthing conductor should be terminated together in the earth terminal provided within the timer.

Technical Specifications

Communications WiFi ISM 2.4GHz; WLAN 802.11 b/g/n
Programming Capacity 15 On/Off programmes in total
Countdown Countdown On or Off
Random Output switches on and off randomly during set period
Repeat A repeating cycle that can be set between ON and OFF times
Power 1 vA @ 230V 50Hz
Resistive Load 16A
Inductive Load 4A
Accuracy Internet synchronised
Minimum Switching 1 Minute
Override On / Timed / Off
Class II Control / Protection Class IP20

Installation

  1. Switch off electric at the mains.
  2. Prepare cable ends for connection to the terminals.
  3. Remove the 1 screw holding the timer switch terminal cover. DO NOT INTERFERE WITH ANY OF THE FIXED CONNECTIONS.
  4. Connect all earth wires to earthing points.
  5. Wire timer in accordance to wiring diagram on the unit.
  6. Use lower screw hole to secure unit to wall plus the mounting hole on rear of unit.
  7. Carefully replace terminal cover ensuring all wires are stowed neatly and not trapped.
  8. Replace screw and tighten.

Wiring Connections

Ensure the earth to the switched appliance is maintained.
Timer to be wired in accordance with wiring diagram on unit.
Any electrical work should be carried out by a qualified electrician.

Smart Life App

  • Free download on Apple IOS & Android

UKCA Information

Complies with European Norm
EN 61058-12002 +A2:2008
Switches for Appliances: General Requirements and European Directives: LVD; EMC; RoHS; RED

Guarantee

This Wall Mounted Wifi Timer Switch is guaranteed for a period of 12 months from date of purchase.
Please retain for future reference

LOWENERGIE - logo

Lowenergie™ is a registered Trademark
www.lowenergie.com
Lowenergie ™ UK

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals