Altonovus LTD OR-01 Low Compliance Voltage Ohmmeter User Manual

June 17, 2024
Altonovus LTD

Altonovus LTD OR-01 Low Compliance Voltage Ohmmeter

Altonovus-LTD -OR-01-Low-Compliance-Voltage-Ohmmeter-
PRO

Product Specifications

  • Model: OR-01 Low Compliance Voltage Ohmmeter
  • IP Rating: IP54
  • Power Source: 2 x AA alkaline batteries
  • Minimum Stimulus: 206mV
  • Maximum Current: 800mA
  • Operating Temperature Range: 20-25 degrees Celsius

Product Usage Instructions

Device Use and Care
Ensure the following precautions are taken to maintain the device:

  • Do not immerse in or expose to liquid.
  • Avoid dropping, exposing to shock, or placing heavy objects on the unit.
  • Avoid applying pressure to the display.
  • Avoid extremes of temperature; maintain accuracy in the 20-25 degree Celsius range.
  • Do not open the unit as it contains no user-serviceable components, and opening it voids warranty and calibration.
  • Only clean the unit with a clean, dry cloth.

Battery Installation

  1. Remove the battery compartment cover by applying gentle pressure to the finger pad.
  2. Ensure clean contacts on batteries.
  3. Insert new batteries observing polarity instructions in the battery compartment.
  4. Replace the battery compartment cover.

Getting Started – Taking a Reading
Follow these steps to take a measurement:

  1. Power On: Turn on the device.
  2. Connect Leads: Connect the leads ensuring they are less than 3 meters in length.
  3. Take Measurements: Observe the resistance reading, range bar, active range, measured current, and signal-to-noise ratio (SNR).
  4. Power Off: Turn off the device after use.

Menu Navigation
To access the menu options, press the Menu button. Use the Navigate and Select buttons to move through the menu. Options include:

  • Measure
  • Voltage
  • Powerdown
  • LCD Light
  • 4 Beep Read
  • Details

Frequently Asked Questions (FAQ)

  • Q: How long do the batteries last?
    A: With 2 x AA alkaline batteries, you can expect in excess of 150 hours of continuous operation.

  • Q: What is the minimum stimulus applied by the device?
    A: The minimum stimulus applied is 206 mV. Do not expose the unit to currents over 800mA.

  • Q: How can I clean the unit?
    A: Use only a clean, dry cloth to clean the unit. Do not immerse it in liquid.

  • Q: What is the operating temperature range for maximum accuracy?
    A: The device operates with maximum accuracy in the range of 20-25 degrees Celsius.

  • Q: Can I open the unit for maintenance?
    A: No, there are no user-serviceable components. Opening the unit voids warranty and calibration.

OVERVIEW

MODEL: OR-01: LOW COMPLIANCE VOLTAGE OHMMETER.
QUICK START GUIDE (Rev 1.0 dated 10 MAR 22)
ALTONOVUS LTD. 37 OAST HOUSE CRESCENT, FARNHAM, SURREY,

  • A – Positive Terminal
  • B – Negative Terminal
  • C – Display Screen
  • D – On / Off Button
  • E – Menu Navigation
  • F – Select Button
  • G – Isolated USB Interface
  • H – Battery Compartment

GETTING STARTED

TAKE A READING

  • STEP 1: POWER ON
    After inserting batteries as shown, press the POWER button to start ΩhmRanger- LCV®.

  • STEP 2: CONNECT LEADS
    Connect the Resistance to be measured between the Positive (RED) and Negative (BLACK) terminals of the ΩhmRanger-LCV®. Leads (not supplied) should be industry standard, uninsulated, 4mm banana plug. Leads of shorter length will help minimise any noise.

  • STEP 3: TAKE MEASUREMENTS
    Sampling at a high rate to eliminate mains noise, Ωhm- Ranger-LCV® takes about 2.5 readings per second. It displays the current in MΩ, KΩ and Ω. In this example, 2.1MΩ.
    A Range Bar below the digits shows which ranges are, and have been in use. The Range Bar oscillates after each reading to show how quickly readings are occurring and to show that the device is functioning correctly.

  • STEP 4: POWER OFF
    After measurements are taken, press the POWER button again to return ΩhmRanger-LCV® to Standby mode.

DEVICE USE AND CARE

Altonovus-LTD -OR-01-Low-Compliance-Voltage-Ohmmeter-
\(8\)

BEFORE USE

INSERT 2 x AA BATTERIES
2 x AA alkaline batteries will give in excess of 150 hours of continuous operation. Treat all batteries in accordance with the manufacturer’s instructions.Altonovus-LTD -OR-01-Low-Compliance-Voltage-Ohmmeter-
\(9\)

  1. Remove battery compartment cover (H) applying gentle pressure to finger pad.
  2. Ensure clean contacts on batteries.
  3. Insert new batteries, observing polarity instructions in battery compartment.
  4. Replace battery compartment cover.

If desired, remove the protective film from the front of the ΩhmRanger-LCV®. Peel carefully from below the Positive and Negative terminals.
ΩhmRanger-LCV® will still function normally if the film is left in place.

SCREEN GUIDE

  • A – The Resistance reading, displayed in MΩ, KΩ and Ω. In the example above, 2.1MΩ.
  • B – A small, oscillating Range Bar shows which range is currently in use. An upper, longer-range coverage Bar shows any movement across the ranges during the reading (in this case, none). The box surrounding shows the operating range.
  • C – The Voltage being applied by ΩhmRanger-LCV® at the Positive terminal, in this case 206.7mV, to measure the resistance.
  • D – The active Range and the measured Current.
  • E – The Signal to Noise Ratio (SNR). The SNR indicates how much noise, variation, and AC components are in the signal, followed by Maximum and Minimum Current samples during the reading. Higher resistances (lower currents) are more susceptible to noise.

BASIC MENU FUNCTIONS

Press the Menu button to exit measuring and enter the Menu mode. This screen will appear. Use the Navigate and Select buttons to move through the Menu.
The options are:

  • Measure
  • Voltage
  • Powerdown
  • LCD Light
  • 4 Beep Read
  • Details

VOLTAGE – Use this Menu option to select the maximum stimulus voltage that will be applied by ΩhmRanger-LCV®.
The options are available are:

  • 380 mV (the default setting), or
  • 206 mV

POWERDOWN – Use this function to set and configure the period of inactivity after which ΩhmRanger-LCV® will power down automatically.

  • Off
  • 30 Minutes
  • 1 Hour (the default)
  • 2 Hours
  • 4 Hours
  • 8 Hours

LCD LIGHT – Use this function to toggle the ΩhmRanger-LCV® screen backlight ON and OFF. Disabling the backlight will extend battery life.

4 BEEP READ – Use this function to take readings only when Resistance values are stable within selected tolerances. An audible prompt is given when this is achieved.

DETAILS – Will display the ΩhmRanger-LCV®’s unique serial number, calibration date and status, and software version.

USING THE FULLY ISOLATED USB INTERFACE

Altonovus-LTD -OR-01-Low-Compliance-Voltage-Ohmmeter-
\(16\)

ΩhmRanger-LCV®’s micro-USB interface can be used to export readings and to control the device via a PC (SCPI-format). The USB interface cannot be used to power ΩhmRanger-LCV®, as it is isolated from the main circuitry to prevent interference. For help connecting ΩhmRanger-LCV®, see the guidance in our website’s ΩhmRanger-LCV® section. For SCPI instructions, please download the full OR-01 Instruction Manual at: www.altonovus.com.

FCC

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the User is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different that to which the receiver is connected.
  • Consult the dealer, or an experienced radio/TV technician for help.

Altonovus-LTD -OR-01-Low-Compliance-Voltage-Ohmmeter-
\(17\) Altonovus-LTD -OR-01-Low-
Compliance-Voltage-Ohmmeter- \(18\)

Altonovus-LTD -OR-01-Low-Compliance-Voltage-Ohmmeter-
\(19\)