LED World Canada MD-012-060VWJV2 60W 12VDC Class 2 Non Dimmable LED Driver User Guide
- June 17, 2024
- LED World Canada
Table of Contents
LED World Canada MD-012-060VWJV2 60W 12VDC Class 2 Non Dimmable LED Driver
PRECAUTIONS BEFORE INSTALLING
- Read all instructions before installation. To be sold with instructions.
- Only qualified personnel should install the unit.
- Installation must comply with the National Electrical Code (Article 450) and Canadian Electrical Code.
- Ensure the unit has the proper input/ output voltage and output wattage for your application.
- Check the wire markings to ensure they match the wiring diagram on this installation guide.
- Turn off power at breaker before starting.
- This is non dimmable driver. Do not use for dimming.
INSTALLATION GUIDELINES
- The driver must be installed in a well-ventilated area free from explosives gases and vapors. Proper operation requires for free flow of air. Do not install inside a cabinet smaller than 12 W x 12 H x 15 L inches. If you are installing multiple drivers, keep a minimum space of 5″ (127mm) between each driver.
- For Indoor or Outdoor use.
- Operate only within specified ambient temperature range of 4 °F (-20°C) to l 04°F (40°C). Operating at cooler surrounding air temperature will extend driver life.
- Do not overload. Total wattage of all LED fixtures used must not exceed the 60 watt rating of this power supply. Maximum of 48 watt for continuous use.
- Route and secure wires so they will not be pinched or damaged.
- All wiring must be in accordance with NEC/CEC, low voltage Class 2 circuit. For wire runs inside of walls, use properly certified CL2 or better cabling and appropriate mounting hardware. If you are unclear as to how to install and wire this product, contact a qualified licensed electrician. Failure to install this device properly may result in electrical shock or fire.
- Do not install Class 2 low voltage wiring in the same run(s) as AC main power.
MOUNTING
Select a suitable location capable of supporting the weight of the transformer. Use the four keyholes on the transformer case. Screw cover closed. Mount the unit at a height greater than l ft (30cm) from the ground.
INPUT CONNECTIONS/ GROUNDING
- Remove the wiring cover (2 screws). Remove the wiring compartment knockout and install strain reliefs (not included). With power turned off at the breaker, route the input wires. Connect one wire to black(L) and one wire to white(N) to the corresponding pigtail wire.
- For all wire connections use only UL/CSA listed wire nuts or wagon connectors of\ suitable size and type.
- The Driver case MUST be grounded in accordance with the NEC/CEC. Connect the ground wire to the driver green wire.
- Use 3/8″ (l /2″ KO) cable connectors (not included) to secure wire.
- If used outdoor, must have knockouts point downwards. Use only outdoor rated UL/CSA listed strain relief (watertight).
- Maximum of 12 AWG through branch circuit conductor suitable for l 05°C (22 l °F) permitted in box.
OUTPUT CONNECTIONS (LOW VOLTAGE)
- Connect the wires of the light fixture to the driver wires – positive to the red(+ ) wire and negative to black(-) wire.
- Measure the output voltage for proper voltage to LED fixture.
- After all wiring completion, screw in wiring cover.
Use appropriate UL/CSA listed wire nuts or wage connectors (not included) to
connect wires
CONNECTION DIAGRAM
Note: Do not use for Dimming
WARNING
-
Prevent reverse polarity.
-
The LED Driver is not to be repaired. Do not use if it is damaged or defective.
-
Installation involves special wiring methods to run wiring through a building structure. Consult a qualified licensed electrician.
-
This is non dimmable driver. Do not use for dimming.
TROUBLESHOOTING
Do not exceed 48 watts of continuous load! Note the wattage information on the item (strip label) that is being powered. If wattage or amperage information is not available or unknown, do not use. Power supply may be very warm if overloaded and will damage the unit (void limited warranty).
This device complies with FCC 47 CFR Part 15, Part B. Operation is subject to the following two conditions: [1 )May not cause harmful interference, 2)Must accept any interference received, including interference that may cause undesired operation.
Customers Support
LED World Inc. | #130 10615 48 ST SE | CALGARY, AB T2C 2B7 | CANADA | Version 1.0 08/24/23
2/2 Copyright © 2023 LED WORLD INC™. All Rights Reserved. We are not responsible for errors or omissions. Product and specifical change without notice. Registered trademarks are owned by their respective registers, or licensee(s).
References
- LED World Canada - A Commercial LED lighting supplier
- LED World Lighting - A Commercial LED lighting supplier
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>