Safety

General
Read these instructions.
Keep this instruction manual.
We are not liable for any direct or indirect damages which could occur when using this Manual
Operating safety
Do not open the housing of the de-vice.
Do not modify the device.
The installation must only be car-ried out by skilled staff.
The device may only be used by trained personnel.
Keep the packaging away from children.
Installation site
Do not expose the device to mois-ture, dust, heat or direct sunlight.
Do not operate the device out-doors.
Make sure that you wait before us-ing the device after any transport until the device has reached the ambient air temperature. Great fluctuations in temperature or humidity may lead to moisture within the device caused by condensation, which can cause a short.

Maintenance

Troubleshooting – Repairs
A detailed documentation on trou-bleshooting can be found in the instruction manual (see chapter 3).
Any repairs must be carried out at the manufacturer’s plant.
Disconnect the power supply immediately and contact your supplier, if …

  • liquid has entered your device
  • the device does not properly work and you cannot rectify this problem yourself.

Cleaning
Please make sure that the device remains clean especially in the area of the connections, the control elements, and the display elements.
Clean your device with a damp cloth only.
Do not use solvents, caustic, or gaseous cleaning substances.

Disposing

**Device
At the end of its lifecycle, do not dispose of your device in the regular household rubbish. Return your device to your supplier who will dispose of it correctly.
Packaging**
Your device is packaged to protect it from damages during transport.
Packaging is made of materials that can be disposed of in an environmentally friendly manner and properly recycled.

General Information: Introduction

Document
This document is a shortened ver-sion of the instruction manuals:
DTS 4132.timeserver BE-801104
DTS 4135/36.timeserver BE-800729
DTS 480x.masterclock BE-800652
The instruction manuals, also for the GNSS 4500 (TE-801333), are available at our website:
See QR Code and web link on the first page.
Scope of Delivery
Please check your delivery for completeness and notify your supplier within 14 days upon receipt of the shipment, if it is incomplete.
The package you received contains:
DTS device (see below)
Mounting set for rack mounting
Connector set
2 mounting tools for the spring ter-minals
Technical data
See chapter 5.
Device description
This quick installation guide is for the master clocks DTS 4801, DTS 4802, DTS 4803 and DTS 4806 as well as the time servers DTS 4132, DTS 4135 and DTS 4136.
Below, the term DTS is used for better readability.

Installation

  1. Select device configuration
    A: Synchronisation durch GNSS / from GNSSMOBATIME DTS 4132 Timeserver -
InstallationB: Synchronisation durch NTP-Server / from NTP server MOBATIME DTS 4132 Timeserver - Installation
1

  2. Prepare network environment
    Prior to the installation in the net-work, coordinate with the network administrator. Have the DHCP server (if available) prepared.
    If no DHCP server is present, the network parameters must be set via the serial interface (see step 7 Serial).
    Unlock port UDP 123 in the network.

  3. Install GNSS receiver
    (configuration A only)
    The GNSS receiver must have an unobstructed view of the sky and thus must be mounted on the outer building facade, ideally on the roof.

  4. Connect GNSS receiver
    (configuration A only)

  5. Connect network cable
    Connect the DTS with the network to be synchronized.
    ATTENTION: If configuration takes place over a serial interface, connect the network cable only after the network configuration.

  6. Connect mains power
    Couple the power plug included in the delivery with a suitable power cable and connect it.
    Mains voltage: 90 -240 VAC / 50 – 60 Hz
    The DTS boots in approx. 60 sec. The end of the booting procedure is indicated by the display.
    Configuration A: The GNSS receiver needs up to 5 min after connecting mains power to receive the time from satellites. Upon successful synchronization, the LED DCF blinks once every second. L = Phase
    N = neutral conductor
    PE = protective ground

  7. Connect to DTS
    With DHCP server:
    Telnet/SSH (e.g. with PuTTY):
    Connect to the DTS using the IP address (press red button until IP
    address appears on display):
    Select Telnet or SSH in PuTTY ➔ enter the IP address and open the connection.
    MOBA-NMS:
    Install software (see BE-800790 Instruction manual MOBA-NMS).
    Automatic device search:
    • Select Unicast (IPv4)
    • Check box of corresponding device
    • Enter password (see below)
    • Enter IP search area (in the correct subnet)
    • Select the DTS device
    • Select “Finish”
    Alternatively add device manually:
    • Select the model
    • Enter password (see below)
    • Enter IP address
    Serial:
    Connect the DTS to the serial interface of the PC via the 9-pole Sub-D plug (front side). Use a crossover cable (null modem) with a socket plug on both sides (female).
    Start a terminal program on the PC (e.g. PuTTY). Comm. parameters: 38400, 8, 1, no parity, no flow control.
    ATTENTION: The correct COM port must be selected.
    Login data:
    Telnet/SSH/Serial
    User name: dts
    Password: dts
    MOBA-NMS
    Password: mobatimeMOBATIME DTS 4132 Timeserver - Connect
1

  8. Configuration
    Define the IP address:
    Telnet/SSH/Serial:
    Open the menu “2 Configuration ➔ 5 Network ➔ 1 IPv4 Configuration”, set network parameters according to the network administrator. After setting the parameters, the terminal program must be restarted.
    Define time source:
    Configuration A:
    Per default, GNSS (GPS) is set as the synchronization source.
    Attention: the time zone must not be modified!
    Configuration B:
    Up to four public NTP servers or servers in the network can be configured (menu “2 Configuration ➔ 2 Time-handling ➔ 3/4* NTP Server”)

  • depending on device
    Check synchronization and status On the DTS with the LED sync:
    Flashes constantly: synchronization OK
    Blinks: DTS runs on internal time, synchronization has not occurred yet
    Additionally for configuration A:
    LED DCF blinks once per second:
    GNSS reception OK

Technical data

| | DTS 4801/03| DTS 4802| DTS4806| DTS 4132| DTS 4135| DTS 4136
---|---|---|---|---|---|---|---
Housing| 19″, 1 HE| √| √| √| √| √| √
Time signal outputs| IRIG, AFNOR DCF-FSK| 0 / 1| | | | 2 precison output, 50 Ohms| 2 precison output, 50 Ohms
| NTP slave clocks + timezone server| 1| 1| 1| 1| 1| 1
| DCF current loop (CL) passive output| 1| 1| 1| 1| 1| 1
| Precision pulse/frequency/DCF output on RS422 and CL| 1| 1| 1| 1| 2| 2
| Serial RS 232/422/485 outputs with configu- rable time telegrams (RS 422: output only)| 1| RS232 only| RS232 only| 2| 2| 2
| MOBALine or polarized Impulses (Impulse line)| 1| 2| 6| 2| |
Network services| NTP client| √| √| √| √| √| √
| NTP V4 (V3 compatibel)| √| √| √| √| √| √
| NTP modes: Server, Peer, Broadcast, Mul- ticast| √| √| √| √| √| √
| SNTP| √| √| √| √| √| √
| TIME, DAYTIME| √| √| √| √| √| √
| NTP MD5 authentication| √| √| √| √| √| √
| Telnet, SSH, FTP – disengageable| √| √| √| √| √| √
| SNMP Notifications| V2c/V3| V2c/V3| V2c/V3√| V2c/V3| V2c/V3| V2c/V3
| SNMP Get, Put| √| √| √| √| √| √
| IP V6 support| √| √| √| √| √| √
Network interface| 10BaseT / 100BaseTX| 1| 1| 1| 2| 1| 1
IP configu- ration| DHCP| √| √| √| √| √| √
| static IP| √| √| √| √| √| √
USB| for update| √| √| √| √| √| √
GBIC-Link| for redundant operation, with master – slave negotiation| | | | √| √| √
External time source| NTP / SNTP servers| √| √| √| √| √| √
| DCF 77 (DCF 450, DCF 4500)| √| √| √| √| √| √
| GNSS 4500| √| √| √| √| √| √
| IRIG-B| | | | | √| √
Accuracy| GNSS (DCF input) to NTP Server typically| < +/- 0.5ms| < +/- 0.5ms| < +/- 0.5ms| < +/- 0.1ms| < +/- 0.1ms| < +/- 0.1ms
| GNSS (DCF input) to DCF output typically| < +/- 1ms| < +/- 1ms| < +/- 1ms| < +/-

0.01ms

| < +/-

0.01ms

| < +/-

0.01ms

| Hold over (after >24h synchronisation) @ 20°C+/- 5°C| <+/- 100ms/d| <+/- 100ms/d| <+/- 100ms/d| < +/- 10ms/d| < +/-
10ms/d| < +/-
1ms/d
| Master to slave (redundant operation)| | | | typ. < +/- 0.001ms| typ. < +/- 0.001ms| typ. < +/- 0.001ms
| Quartz Oscillator| standard| standard| standard| TCXO| TCXO| OCXO
| IRIG (modulated) to GNSS (DCF input)| | | | | < 0.1ms| < 0.1ms
| IRIG (digital) to GNSS (DCF input)| | | | | < 0.01ms| < 0.01ms
RTC| Real Time Clock (disengageable)| 1| 1| 1| 1| 1| 1
Display| 2 lines, 16 character each| √| √| √| √| √| √
Operation control| MOBA-NMS| √| √| √| √| √| √
| Telnet| √| √| √| √| √| √
---|---|---|---|---|---|---|---
| SSH| √| √| √| √| √| √
| RS 232 (PC-Terminal)| √| √| √| √| √| √
| SNMP (V2c/V3 Get, Put)| √| √| √| √| √| √
Alarm out- put| Relais| √| √| √| √| √| √
| SNMP Notifications| V2c/V3| V2c/V3| V2C/V3| V2c/V3| V2c/V3| V2c/V3
| Mail| √| √| √| √| √| √
Alarm input| (control inputs)| 4 (control
inputs)| 4 (control
inputs)| 4 (control
inputs)| 1| 1| 1
Power supply| Redundant power supply (mains/DC or DC/DC)| √| √| √| supervi- sed| supervi- sed| supervi- sed
| Mains| 90-240
VAC| 90-240
VAC| 100-240
VAC| 85-265
VAC| 90-240
VAC| 90-240
VAC
| 24 VDC
28 VDC recommended for MOBALine usage| √| √| √| √*| √| √
| Power consumption| 30 W| 30 W| Max 200W
Max 400W (ex- tended version)| 30 W| 15 W| 15 W

Certification of the Producer
STANDARDS
The DTS 4132.timeserver, DTS 4135.timeserver, DTS 4136.timeserver, DTS 4801.masterclock, DTS 4802.masterclock, DTS 4803.masterclock and DTS 4806.masterclock were developed and produced in accordance with the EU Guidelines:
2014 / 30 / EU EMC
2014 / 35 / EU LVD
2008 / 57 / EU Railway
2011 / 65 / EU RoHS
1907 / 2006 REACH
2012 / 19 / EU WEEE

It is prohibited to reproduce, to store in a computer system or to transfer this publication in a way or another, even part of it. The copyright remains with all the rights with BÜRK MOBATIME GmbH, D-78026 VS-Schwenningen and MOSER-BAER AG – CH 3454 Sumiswald / SWITZERLAND.

Headquarters/Production
Sales Worldwide
MOSER-BAER AG | Spitalstrasse 7 | CH-3454 Sumiswald
Tel. +41 34 432 46 46 | Fax +41 34 432 46 99
moserbaer@mobatime.com | www.mobatime.com
Sales Switzerland
MOBATIME AG | Stettbachstrasse 5 | CH-8600 Diibendorf
Tel. +41 44 802 75 75 | Fax +41 44 802 75 65
info-d@mobatime.ch | www.mobatime.ch
MOBATIME SA | En Budron H 20 | CH-1052 Le Mont-sur-Lausanne
Tél. +41 21 654 33 50 | Fax +41 21 654 33 69
info-f@mobatime.ch | www.mobatime.ch
Sales Germany/Austria
BURK MOBATIME GmbH
Postfach 3760 | D-78026 VS-Schwenningen
Steinkirchring 46 | D-78056 VS-Schwenningen
Tel. +49 7720 8535 0 | Fax +49 7720 8535 11
buerk@buerk-mobatime.de | www.buerk- mobatime.de
© MOBATIME
QX-801148.05

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals