Important before beginning to assemble
- The assembly instructions apply in general and can vary from version to version.
- Before starting to assemble check the packing list, if the product is complete and intact. Eventual complaints can be easily solved accordingly.
- We reserve the right to perform technical modifications for the purpose of further product development.
- A minimum room height of 215 cm is necessary.
- Distance to the wall must be at least 5cm.
- We recommend placing the cabin in a well ventilated, dry room.
- We recommend a tile or stone floor, which must be level and horizontal.
- Install the electric cables in the walls beforehand. Later it may be difficult.
- Pre-drill all screw connections.
The material wood and its characteristics
Wood is a naturally grown material. Healthy knots, small cracks due to the
process of drying and minor discolorations are natural and characteristic
properties and are not optical or constructive defects.
Due to the heating of the sauna more resin can come out onto the surface.
Remove the resin residue with a scraper and fine sandpaper after the sauna has
cooled down.
Care instructions
The sauna should be cleaned regularly. To do so, use a damp cloth and no cleaning detergents. The wooden parts of the sauna must not be painted, lacquered or surface treated in any other way.
Electric installations
Electric installations may only be carried out by an authorized electrician under observing the EVU and VDE regulations.
The assembly instructions and notes for the heater, control and sauna lamps are included in the respective packaging.
Terms of warranty and guarantee
The guarantee for the wooden construction, the finishing quality and the electric parts is 2 years and claims can only be made on presentation of the original invoice. Within the guarantee period defective parts will be replaced free of charge. The cost for labour and travel, resulting from the exchange, are not included.
Product Description
Pos | Description | Quantity |
---|---|---|
1 | Side wall 538 | 4 |
2 | Backwall 675 | 1 |
3 | Back wall with radiator | 1 |
4 | Front wall 362 | 1 |
5 | Front wall with control panel 362 | 1 |
6 | Door frame | 1 |
7 | Door | 1 |
8 | Floor cornice | 4 |
9 | Joining batten | 14 |
10 | Corner post | 4 |
11 | Roof battens | 3 |
12 | Roof battens | 4 |
13 | Roof 538 | 2 |
14 | Bench 520 | 1 |
15 | Bench 340 | 1 |
16 | Back rest | 1 |
17 | Radiator with back padding | 1 |
18 | Bench facing | 1 |
19 | Short bench battens | 2 |
20 | Long bench battens | 2 |
21 | Heater protective grille | 1 |
22 | Floor grating | 1 |
23 | Ventilation slide | 1 |
24 | Assembly material | 1 |
25 | Assembly instructions | 1 |
Instruction For Use
Operating instructions LED-coloured light „Sion 1A“ Art. Nr.: S2291A
Delivery contents:
- LED-lamp incl. wooden frame
- Power supply
- Mains lead
- LED-controller
- Remote control
- Locking screws
Dimensions (HxWxD): 240 x 240 x 38 mm
Technical details:
Input power supply: AC 100-240 V~ 50-60 Hz Output: DC 12 V; 5 A
General safety regulations:
- All electrical installations may only be carried out by an authorized electrician.
- Pay attention to the operating instructions.
- Keep away children from the LED-coloured light.
- Disconnect the main power plug before cleaning the device.
- LED-controller and power supply have to be installed outside of the sauna or infrared cabin.
- The coloured light is able to bear temperatures up to 110 °C
Installation Sion A-series (overhead installation):
- Place the LED-coloured light at the desired spot and mark the corners of the LED-coloured light with a pen (Fig. 4).
- Mark the position of the drilling for the mains lead in the middle of the colour light, 40 mm away from the lateral edge (Fig. 5).
- Drill a hole (Ø at least 20 mm) through the roof of the sauna or infrared cabin (Fig. 5).
- Attach the LED-coloured light with the enclosed screws to the ceiling.
Remote control:
- The multi-colour wheel allows selecting the desired colour with a touch sensor directly on the remote control.
- For changing the individual modes press the buttons M+ (forward) or M- (back).
- The controller remembers the mode which had been active before the LED coloured light was switched off. After the power-up again, the same mode starts again, as previously set.
2 automatic colour changes:
The automatic colour change starts when the MODE button is pressed 8 x (see table below).
Mode no. | Function | Remark |
---|---|---|
1 | Colour red | Luminosity adjustable, speed not adjustable |
2 | Colour green | Luminosity adjustable, speed not adjustable |
3 | Colour blue | Luminosity adjustable, speed not adjustable |
4 | Colour violet | Luminosity adjustable, speed not adjustable |
5 | Colour turquoise | Luminosity adjustable, speed not adjustable |
6 | Colour yellow | Luminosity adjustable, speed not adjustable |
7 | Colour white | Luminosity adjustable, speed not adjustable |
8 | Smooth 3 colour change | Speed adjustable, luminosity not adjustable |
9 | Smooth 7 colour change | Speed adjustable, luminosity not adjustable |
Precautions:
- The installation of the power supply inside a sauna or a steam bath is not permitted!
- Install the power supply only in dry rooms, outside the sauna (e.g.: at the roof of the sauna).
- Leave enough empty space all around the power supply to allow, that it can be cooled down (room temperature is sufficient).
- The power supply must not be encapsulated or installed into a wall-construction.
Customer Support
TPI GmbH, Rieglerstr. 21, 4873 Frankenburg, Austria Tel.: +43 7683 5022 / E-Mail: office@tpi.co.at / Web: www.infraworld.at
Technische Änderungen vorbehalten © by TPI GmbH, Frankenburg, Austria