General notes

Read these original operating instructions and the enclosed safety instructions before using the device for the first time. Proceed accordingly. Keep both books for future reference or for future owners.

Intended use

Only use the appliance in private households. The appliance is intended for cleaning with steam and can be used with appropriate accessories as described in these operating instructions. Detergents are not required. Observe the safety instructions.

Environmental protection

The packing materials can be recycled. Please dispose of packaging in accordance with the environmental regulations.
Electrical and electronic appliances contain valuable, recyclable materials and often components such as batteries, rechargeable batteries or oil, which – if handled or disposed of incorrectly – can pose a potential threat to human health and the environment. However, these components are required for the correct operation of the appliance. Appliances marked by this symbol are not allowed to be disposed of together with the household rubbish.
Notes on the content materials (REACH)
Current information on content materials can be found at: www.kaercher.com/REACH

Accessories and spare parts

Only use original accessories and original spare parts. They ensure that the appliance will run fault-free and safely. Information on accessories and spare parts can be found at www.kaercher.com.

Scope of delivery

The scope of delivery for the appliance is shown on the packaging. Check the contents for completeness when unpacking. If any accessories are missing or in the event of any shipping damage, please notify your dealer.

Warranty

The warranty conditions issued by our relevant sales company apply in all countries. We shall remedy possible malfunctions on your appliance within the warranty period free of cost, provided that a material or manufacturing defect is the cause. In a warranty case, please contact your dealer (with the purchase receipt) or the next authorised customer service site. (See overleaf for the address)

Safety devices

CAUTION
Missing or modified safety devices
Safety devices are provided for your own protection. Never modify or bypass safety devices.

Symbols on the device

(according to type of appliance)

| Risk of burns, surface of appliance becomes hot during operation
---|---
| Risk of scalding from steam
| Read operating instructions

Pressure controller

The pressure controller keeps the pressure in the steam boiler as constant as possible during operation. The heating is switched off when the maximum operating pressure is reached in the steam boiler and is activated if there is a pressure drop in the steam boiler as a result of a steam removal.

Safety thermostat

The safety thermostat prevents the device from overheating. If the pressure regulator and the boiler thermostat fail and the unit overheats, the safety thermostat switches the unit off. Before resetting of the safety thermostat, contact the responsible KÄRCHER Customer Service.

Boiler thermostat

The boiler thermostat switches off the heating in the event of a fault; for example, if there is no water in the steam boiler and the temperature in the steam boiler rises. As soon as you refill the water, the device is ready for use again.

Maintenance lock

The maintenance lock seals the steam boiler from the steam pressure present. The maintenance cap is also a pressure relief valve. If the pressure regulator is defective and the steam pressure in the steam boiler rises, the pressure relief valve opens and steam is escapes through the lock.
Prior to restarting the device, contact the responsible KÄRCHER Customer Service.

Description of the device

The maximum amount of equipment is described in these operating instructions. Depending on the model used, there are differences in the scope of delivery (see packaging).
For the illustrations, refer to the graphics. Illustration A

  1. Device socket with cover
  2. Water reservoir
  3. Carrying handle for the water reservoir
  4. Selector switch
  5. Control panel
  6. Display – OFF position
  7. Display – water shortage (red)
  8. Display – heating (green)
  9. Min. steam stage
  10. Steam setting selection range
  11. Max. steam stage
  12. VapoHydro function steam stage
  13. Cap for accessory compartment
  14. Maintenance lock
  15. Carrying handle
  16. Holder for accessories
  17. Accessory storage compartment
  18. Mains connection cable storage compartment
  19. Park bracket for floor nozzle
  20. Mains connection cable with mains plug
  21. Non-driven wheels (2 x)
  22. Steering roller
  23. Steam gun
  24. Steam lever
  25. Unlocking button
  26. Child lock
  27. Steam hose
  28. Steam connector
  29. Spotlight nozzle
  30. Round brush (small)
  31. **Power nozzle
  32. **Round brush (large)
  33. Manual nozzle
  34. Manual nozzle microfibre cover
  35. Extension tubes (2 x)
  36. Unlocking button
  37. Floor nozzle
  38. Hook and loop fastener
  39. Microfibre floor cloth (1 x)
  40. **Microfibre floor cloth (2 x)
  41. **Carpet glider
  42. Descaler
  43. **Steam pressure iron
  44. Indicator light (orange) – heating
  45. Steam switch (bottom)
  46. Steam connector
    ** optional

Installation

Installing accessories
  1. Open the cover on the device socket.
    Illustration B
    SC 5 EasyFix Premium Iron Installation illustration

  2. Connect the steam connector to the device socket so that the steam connector audibly engages.
    Illustration B
    SC 5 EasyFix Premium Iron Installation illustration

  3. Push the open end of the accessory onto the steam gun so that the unlocking button on the steam gun engages.
    Illustration H
    SC 5 EasyFix Premium Iron Installation illustration

  4. Push the open end of the accessory onto the spotlight nozzle.
    Illustration I
    SC 5 EasyFix Premium Iron Installation illustration

  5. Connect the extension tubes with the steam gun. a Push the 1st Push the first extension tube onto the steam gun so that the unlocking button on the steam gun engages. The connection pipe is connected. b Push the 2nd extension tube onto the 1st extension tube. The connection pipes are connected.
    Illustration J
    SC 5 EasyFix Premium Iron Installation illustration

  6. Push the accessory and / or the floor nozzle onto the free end of the extension tube.
    Illustration K
    SC 5 EasyFix Premium Iron Installation illustration

    The accessory is connected.

Disconnecting accessories
  1. Set the child lock to the rear. The steam lever is locked.
  2. Push the cover on the device socket down and disconnect the steam connector from the device socket.
  3. Push the unlocking button and pull the parts apart.
    Illustration O
    SC 5 EasyFix Premium Iron Installation illustration

Operation

Filling water

The water reservoir can be removed at any time for filling or be filled directly at the device.
ATTENTION
Damage to the device
Unsuitable water can block the nozzles or damage the water level indicator. Do not fill in pure distilled water. Use a maximum of 50% distilled water mixed with tap water. Do not use condensation from the clothes dryer for filling. Do not use collected rain water for filling. Do not use cleaning agents or other additives (e.g. scents) for filling.
Remove the water reservoir for filling

  1. Pull the water reservoir vertically upwards.
    Illustration C
    SC 5 EasyFix Premium Iron Operation illustration

  2. Fill the water tank vertically with tap water or a mixture of tap water and no more than 50% distilled water up to the “MAX” mark.

  3. Insert the water reservoir and press downwards until it locks into place.

Filling the water reservoir directly on the device

1. Fill tap water or a mixture of tap water and no more than 50% distilled water from a vessel into the filling hole of the water reservoir up to the “MAX” mark. Illustration D
SC 5 EasyFix Premium Iron Operation illustration

Switching on the device

Note If there is no or too little water in the steam boiler, the water pump starts to run and pumps water from the water reservoir into the steam boiler. The filling process can take several minutes.
Note The device briefly closes the valve every 60 seconds causing an audible soft click. Closing prevents the valve from clogging. This does not affect the steam output.

  1. Place the device on a firm surface.

  2. Insert the mains plug into a socket.
    Illustration E
    SC 5 EasyFix Premium Iron Operation illustration

  3. Turn the selector switch from the OFF position to the
    steam setting selection range. The green heating indicator light flashes.
    Illustration F
    SC 5 EasyFix Premium Iron Operation illustration

  4. Wait until the green heating indicator stays on.
    Illustration G
    SC 5 EasyFix Premium Iron Operation illustration

  5. Press the steam lever.
    Illustration H
    SC 5 EasyFix Premium Iron Installation illustration

    Steam leaks out.

Regulating the steam volume

The expelled steam volume is regulated using the selector switch for steam volume. The selector switch has the setting options min. steam stage for light soiling to max. steam stage for heavy soiling. The VapoHydro function is for the removal of heavy soiling in areas that are difficult to access.

  1. Set the selector switch for the steam volume to re- quired steam volume.
  2. Press the steam lever.
  3. Before starting cleaning, point the steam gun at a cloth until steam is expelled evenly.
Refilling water

If there is not enough water, the water shortage indicator lamp flashes red and a signal tone sounds.
Note
The water pump fills the steam boiler at intervals. If the filling is successful, the red water shortage indicator lamp goes out.
Note
If there is no or too little water in the steam boiler, the water pump starts to run and pumps water from the water reservoir into the steam boiler. The filling process can take several minutes.
ATTENTION
Damage to the device
Unsuitable water can block the nozzles or damage the water level indicator.
Do not fill in pure distilled water. Use a maximum of 50% distilled water mixed with tap water.
Do not use condensation from the clothes dryer for filling.
Do not use collected rain water for filling.
Do not use cleaning agents or other additives (e.g. scents) for filling.

  1. Fill the water tank with tap water or a mixture of tap water and no more than 50% distilled water up to the “MAX” mark. The device is ready for use.
Switching off the device
  1. Turn the trigger to “OFF” position.
    Illustration N
    SC 5 EasyFix Premium Iron Operation illustration

    The device is switched =off.

  2. Set the child lock to the rear. The steam lever is locked.

  3. Push the cap on the device socket down and disconnect the steam connector from the device socket.

  4. Pull the mains plug out of the socket.

  5. Drain the water reservoir.

Rinsing out the steam boiler

Rinse the device’s steam boiler out after every eighth filling of the tank.

  1. Switch the device off; see Chapter Switching off the device.

  2. Allow the device to cool down.

  3. Drain the water reservoir.

  4. Remove the accessory/accessories from the acces- sory holders.

  5. Open the cap of the accessory compartment.

  6. Remove the accessory/accessories from the acces- sory compartment.

  7. Open the maintenance lock. To do this place the open end of an extension tube on the maintenance lock, insert this into the guide so it engages and open it.
    Illustration R
    SC 5 EasyFix Premium Iron Operation illustration

  8. Fill the steam boiler with water and swing it around vigorously. Lime residue which has been deposited on the bottom of the steam boiler will be released as a result.

  9. Drain the water completely out of the steam boiler.
    Illustration S
    SC 5 EasyFix Premium Iron Operation illustration

Storing the device
  1. Store the round brush in the accessory compartment.

  2. Connect a manual nozzle to one extension tube.

  3. Connect the extension tubes to the accessory hold- ers.

  4. Insert the spotlight nozzle in the storage for acces- sories.

  5. Hang the floor nozzle in the park bracket.
    Illustration P
    SC 5 EasyFix Premium Iron Operation illustration

  6. Wind the steam hose around the extension tube and connect the steam gun to the floor nozzle.
    Illustration Q
    SC 5 EasyFix Premium Iron Operation illustration

  7. Store the mains cable in the storage for the mains cable.

  8. Store the device in a dry location that is protected from frost.

Important application instructions

Cleaning the floor areas

We recommend sweeping the floor or vacuum cleaning it before using the appliance. In this way the floor will be cleared of dirt and loose particles before the wet cleaning.

Freshening up textiles

Prior to using the appliance, always check the compatibility of the textiles at a concealed point: Steam down the textile, allow it to dry and then check it for any change in colour or shape.

Cleaning coated or painted surfaces

ATTENTION
Damaged surfaces
Steam can loosen wax, furniture polish, plastic coatings or paint and edge band from edges.
Do not direct the steam at glued laminated edges as the edge band may loosen. Do not use the appliance for cleaning unsealed wood or parquet floors.
Do not use the appliance for cleaning painted or plastic coated surfaces such as kitchen or living room furniture, doors or parquet.

  1. To clean these surfaces, steam a cloth briefly and use it to wipe over the surfaces.
Glass cleaner

ATTENTION
Glass breakages and damaged surfaces
Steam can damage sealed points of the window frame and, at low outside temperatures, lead to tension on the surface of window panes and hence to glass breakages. Do not direct the steam at sealed points on the window frame. At low outside temperatures, heat up the window panes by gently steaming the full surface of the glass.

  • Clean the window area with a manual nozzle and cover. To remove the water, use a squeegee or wipe the surfaces dry.

How to use the Accessories

Steam gun
  • The steam gun can be used for the following applications without accessories: For removing slight creases from the hanging cloth- ing items: Steam the clothing item from a distance of 10-20 cm.
  • For wiping damp dust: Steam a cloth briefly and use it to wipe over the furniture.
Spotlight nozzle

The spotlight nozzle is suitable for cleaning areas, joins, fittings, drains, sinks, WCs, blinds or radiators that are difficult to access. The closer the spotlight nozzle is to the soiled area, the greater the cleaning efficiency will be as the temperature and steam volume are at their highest at the nozzle opening. Larger lime deposits can be treated before steam cleaning with a suitable detergent. Allow the detergent to soak in for approx. 5 minutes and then steam it off.

  1. Slide the spotlight nozzle onto the steam gun.
    Illustration H
    SC 5 EasyFix Premium Iron Installation illustration

Round brush (small)
The small round brush is used for cleaning stubborn dirt. Stubborn dirt can be removed more easily by brushing.
ATTENTION
Damaged surfaces
The brush may scratch sensitive surfaces. It is not suitable for cleaning sensitive surfaces.

  1. Fit the round brush to the spotlight nozzle.
    Illustration I
    SC 5 EasyFix Premium Iron Installation illustration

Round brush (large)
The large round brush is suitable for cleaning large rounded surfaces, e.g. wash basin, shower tray, bath tub, kitchen sink.
ATTENTION
Damaged surfaces
The brush may scratch sensitive surfaces. It is not suitable for cleaning sensitive surfaces.

  1. Fit the large round brush to the spotlight nozzle.
    Illustration I
    SC 5 EasyFix Premium Iron Installation illustration

Power nozzle
The power nozzle is used for cleaning stubborn dirt, blowing down corners, joins etc.

  1. Install the power nozzle onto the spotlight nozzle ac- cording to the round brush.
    Illustration I
    SC 5 EasyFix Premium Iron Installation illustration
Manual nozzle

The manual nozzle is used for cleaning small areas that can be washed down, shower cubicles and mirrors.

  1. Push the manual nozzle onto the steam gun accord- ing to the spotlight nozzle.
    Illustration H
    SC 5 EasyFix Premium Iron Installation illustration

  2. Pull the cover over the manual nozzle.

Floor nozzle

The floor nozzle is used for cleaning washable wall and floor coverings e.g. stone floors, tiles and PVC floors.
ATTENTION
Damage due to build-up of steam
Heat and moisture can lead to damage. Check the heat resistance and steam effect on an inconspicuous area using a minimal volume of steam prior to use.
Note
Detergent residue or care emulsions on the surface to be cleaned can lead to streaks during steam cleaning, which will disappear however once these have been used several times. We recommend sweeping the floor or vacuum cleaning it before using the device. In this way the floor will be cleared of dirt and loose particles before the wet cleaning commences. Work slowly on surfaces that are heavily soiled so that the steam has longer to take effect.

  1. Connect the extension tubes with the steam gun.
    Illustration J
    SC 5 EasyFix Premium Iron Installation illustration

  2. Push the floor nozzle onto the extension tube.
    Illustration K
    SC 5 EasyFix Premium Iron Installation illustration

  3. Fasten the floor cleaning cloth to the floor nozzle.
    a Place the floor cleaning cloth with the hook and loop fastener strips pointing upwards on the floor.
    b Place the floor nozzle onto the floor cleaning cloth, applying slight pressure.
    Illustration L
    SC 5 EasyFix Premium Iron Operation illustration
    The floor cleaning cloth will stick to the floor nozzle of its own accord due to the hook and loop fastener.

Removing the floor cleaning cloth

  1. Place one foot on the bottom corner of the floor cleaning cloth and lift the floor nozzle up.
    Illustration L
    SC 5 EasyFix Premium Iron Operation illustration

Note
Initially, the floor cleaning cloth’s hook and loop fastener strip is very strong and cannot be removed from the floor nozzle easily. After the floor cleaning cloth has been used several times and washed, it is easier to remove from the floor nozzle and it has reached the optimum adhesion.
Parking the floor nozzle

  1. Hang the floor nozzle in the park bracket during breaks in work.
    Illustration P
    SC 5 EasyFix Premium Iron Operation illustration

Carpet glider
The carpet glider is used for freshening up carpets.
ATTENTION
Beware of damaging the carpet glider and carpet
Contamination on the carpet glider, as well as heat and moisture penetration, can result in the carpet being damaged.
Prior to the application, also check the heat resistance and impact of steam on the carpet at an insignificant spot using as small an amount of steam as possible. Observe the cleaning instructions from the carpet manufacturer.
Prior to using the carpet glider, make sure that the carpet has been vacuumed and that stains have been removed.
Prior to application and following operating pauses, remove any possible water accumulation (condensate) in the appliance by means of evaporating the condensate into a drain (without floor cleaning cloth / with accessories).
Only use the carpet glider with a floor cleaning cloth on the floor nozzle.
Steam clean with a weak steam stage when using the carpet glider.
In order to prevent too much moistening and to avoid the risk of damage due to temperature effects, do not direct the steam continuously onto one spot (maximum 5 seconds).
Do not use the carpet glider on deep-pile carpets.

Fastening the carpet glider to the floor nozzle

  1. For fastening the floor cleaning cloth to the floor nozzle, please refer to chapter Floor nozzle.
    Illustration L
    SC 5 EasyFix Premium Iron Operation illustration

  2. Using a little force, allow the floor nozzle to slide into the carpet glider and engage there.
    Illustration M
    SC 5 EasyFix Premium Iron Operation illustration

  3. Start cleaning the carpet.

Removing the carpet glider from the floor nozzle
CAUTION
Beware of burns to your fee t
The carpet glider can heat up during the steaming process.
Do not operate or remove the carpet glider bare-footed or using open sandals.
Only operate or remove the carpet glider using suitable footwear.

  1. Press the strap on the carpet glider downwards us- ing your toecap. 2. Lift the floor nozzle upwards.
    Illustration M
    SC 5 EasyFix Premium Iron Operation illustration
Iron steam pressure

Note
We recommend using the KÄRCHER ironing board with active steam suctioning. This ironing board is optimally matched to the device you have acquired. It facilitates and speeds up the ironing process. In any case, the ironing board used should have a steam-permeable, grid-like ironing base surface.
Note
It should be noted that in the case of an ironing board without steam extraction, it is possible for an ironing board cover to become wet if condensate accumulates.

Initial startup of steam pressure iron
ATTENTION
Material damage due to condensate/moisture
Ironing may cause condensation to drip on the floor and damage sensitive floor coverings. If possible, perform ironing tasks on a floor covering which is insensitive to condensation (e.g. tiles/stone).
For sensitive floor covering, ensure that the area on which condensation can drip is adequately protected (e.g. water-impermeable floor mat).
Note
The iron plate must be hot to prevent steam from condensing on the sole plate and dripping onto the ironing laundry.
Note
Do not turn on the steam stage for the VapoHydro function when the steam pressure iron is plugged in, since otherwise the ironing laundry will get wet.

Recommended steam stages

level Clothing fabrics
Min. steam stage Garments with few wrinkles
Max. steam stage Jeans
  1. Ensure that tap water or a mixture of tap water and no more than 50% distilled water is in the steam boiler of the steam cleaner.
  2. Insert the steam plug of the iron into the unit plug until it clicks into place.
  3. Putting the steam cleaner into operation, see chapter Switching on the device.
  4. Wait until the steam cleaner is ready for use.
  5. The iron is ready for use as soon as the indicator light (orange) has gone out.
  6. The warning light comes on during use, when the iron is reheating. The application must not be interrupted during reheating.

Steam ironing
ATTENTION
Damage to garments
Failure to observe the ironing information in the garment may result in damage.
Observe the ironing information in the garment.
Note
With the fixed, optimal temperature setting, all ironable textiles can be ironed without additional temperature setting. Smooth delicate fabrics and imprints on the back with steam without direct contact with the iron. Steaming the fabrics at a distance of 2 to 3 cm will gently straighten the fibres.
Note
The iron is fitted with an automatic switch-off which switches off the device if it has not been moved for more than 5 minutes. This automatic shut-off increases safety and saves energy as the iron does not heat up continuously. The iron will switch back on as soon as it is moved and start heating up.
Note
The iron can be held vertically for steaming curtains, dresses, etc.

  1. As soon as the heating indicator light (orange) of the iron goes out, ironing can be started. 2
  2. Press the steam switch on the handle below. Steam emits as long as the switch is pressed.
  3. Before ironing and after pauses in the ironing pro- cess, direct the blast of steam onto a cloth until the steam flows evenly.

Dry ironing
ATTENTION
Damage to the device
Water shortage in the steam boiler leads to damage to the device Make sure that there is water in the steam boiler.
ATTENTION
Damage to garments
Failure to observe the ironing information in the garment may result in damage. Observe the ironing information in the garment.
Note
With the fixed, optimal temperature setting, all ironable textiles can be ironed without additional temperature setting. Delicate fabrics and prints should not be dry ironed.

  • Wait until the heating indicator light (orange) of the iron goes out. The iron is ready for ironing.

Care and service

Descaling the steam boiler

Note
Descaling the steam boiler is not required if commercially available distilled water is used.
Note
Since the lime clogs the appliance, we recommend descaling the appliance based on the number of times the water reservoir is filled as specified in the table (TF=tank fillings)

Hardness range °dH mmol/l TF
I sof 0-7 0-1.3
II Medium 7-14 1.3-2.5
III Hard 14-21 2.5-3.8
IV Very hard >21 >3.8

Note
Your water board or municipal utilities authority can provide information on hardness of tap water.
ATTENTION
Damaged surfaces
The descaler may corrode sensitive surfaces.
Fill and empty the appliance carefully

  1. Switching off the device, see chapter Switching on the device.

  2. Allow the device to cool down.

  3. Drain the water reservoir.

  4. Remove the accessory/accessories from the accessory holders.

  5. Open the cap of the accessory compartment.

  6. Remove the accessory from the accessory compartment.

  7. Open the maintenance lock. To do this place the open end of an extension tube on the maintenance lock, insert this into the guide so it engages and open it.
    Illustration R
    SC 5 EasyFix Premium Iron Operation illustration

  8. Drain the water completely out of the steam boiler.
    Illustration S
    SC 5 EasyFix Premium Iron Operation illustration
    ATTENTION
    Appliance damage due to descaler
    An unsuitable descaler or incorrect dosing of the descaler may damage the appliance.
    Only use KÄRCHER descaler.
    Use 1 dosing unit of the descaler for 0.5 l water

  9. Apply descaler solution to the descaler according to the details.

  10. Fill the descaler solution into the steam boiler. Do not seal the steam boiler.

  11. Allow the descaler solution to take effect for approx. 8 hours.

  12. Drain descaler solution completely out of the steam boiler.

  13. Repeat the descaling process if necessary.

  14. Rinse the steam boiler 2-3 times with cold water in order to drain all the descaler solution residue.

  15. Drain the water completely out of the steam boiler.
    Illustration S
    SC 5 EasyFix Premium Iron Operation illustration

  16. Dry the mounting for the grid connection cable.

  17. Close the maintenance lock with an extension tube.

Care of accessories

(Accessories – depending on scope of delivery)
Note
The micro fibre cloths are not suitable for dryer.
Note
When washing the cloths, observe the instructions on the washing tag. Do not use any liquid softeners as this will affect the ability of the cloths to pick up dirt.

  1. Wash the floor cleaning cloths and covers at a max. temperature of 60 °C in the washing machine.

Troubleshooting guide

Malfunctions often have simple causes that you can remedy yourself using the following overview. When in doubt, or in the case of malfunctions not mentioned here, please contact your authorised Customer Service.
WARNING
Risk of electric shock and burns

Trying to eliminate faults while the appliance is connected to the mains or has not yet cooled down is always dangerous.
Remove the mains plug.
Allow the appliance to cool down.
The water shortage indicator light flashes red and a signal tone sounds
No water in the tank.

  • Fill the water reservoir up to the “MAX” marking.
    The water shortage indicator light is lit in red
    No water in the steam boiler. The pump’s overheat protection has triggered.
    1. Switch the device off; see Chapter Switching off the device.
    2. Fill the water reservoir.
    3. Switch on the device; see Chapter Switching on the device.
    The water tank is not inserted correctly or is calcified.
    1. Remove the water reservoir.
    2. Rinse the water reservoir.
    3. Insert the water reservoir and press downwards until it locks into place.
    The steam lever cannot be pressed
    The steam lever is locked with the child lock.

  • Set the child lock (selector switch for steam volume) to the front.
    The steam lever is released.
    Long heating-up time
    The steam boiler is scaled.

  • Descale the steam boiler.
    High water output
    The steam boiler is scaled.

  • Descale the steam boiler.
    VapoHydro steam stage set.

  • Turn the selector switch to the steam setting selection range.
    The steam pressure iron “spits” water

  • Rinse or descale the steam boiler of the steam cleaner; see Chapter Descaling the steam boiler
    After ironing breaks, water droplets come out of the steam pressure iron
    During longer ironing breaks, steam can condense in the steam line.

  • After pauses in the ironing process, direct the blast of steam onto a cloth until the steam flows evenly

www.kaercher.com/welcome

|

www.kaercher.com/dealersearch Alfred Kärcher SE & Co. KG Alfred-Kärcher-Str. 28-40 71364 Winnenden (Germany) Tel.: +49 7195 14-0
Fax: +49 7195 14-2212

|
---|---|---

KARCHER-Logo.png

Documents / Resources

| KARCHER SC 5 EasyFix Premium Iron [pdf] Instruction Manual
SC 5 EasyFix Premium Iron, EasyFix Premium Iron, Premium Iron, Iron
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals