SAFETY

SAFETY & CAUTIONS

SAFETY GUIDE

  • USERS MUST PAY ATTENTION TO THE INFORMATION PROVIDED HERE TO ENSURE SAFETY.
  • We suggest you read the following statements carefully before using the system.
  • If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
  • Never replace the battery by yourself. Risk of explosion if the battery is replaced by an incorrect type.

WARNING

  • If this product is used without observing the information given under this symbol, it might cause injuries or loss of life.

CAUTION

  • If this product is used without observing the information given under this symbol, it might cause damage to this product.

WARNING

  • HAZARD ENVIRONMENT
  • Do not use this system in explosive environments such as gasoline or alcohol storage tanks.

WARNING

  • FLAMMABLE GASES
  • Do not use this system near flammable gases.

WARNING

  • INDUSTRIAL USAGE ONLY

WARNING

  • INTENSIVE LIGHT MAY CAUSE EYE INJURY
  • Avoid looking at the probe head while the LED is on.

CAUTION

  • CERTAIN SUBSTANCES MAY DAMAGE THE PROBE
  • Please refer to the Chemical resistance below. Contact the store you purchased for unsure chemical solutions for further information.

Chemical Resistance

  • Water
  • Brake fluid
  • Gasoline
  • Diesel fuel
  • Transmission fluid

CE NOTICE
The W4239 Wi-Fi articulation video scope system is in conformance with the following standards:
2014/53/EU Electromagnetic Compatibility Directive

RoHS NOTICE

The W4239 Wi-Fi articulation video scope system is in conformance with the requirements of the European law on the Restriction of Hazardous Substances (RoHS) directive. This means that our product is both lead-free and without hazardous substances either in the manufacturing process or in the final product.

FCC STATEMENT

NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, according to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used under the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

This device meets the government’s requirements for exposure to radio waves. This device is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy set by the Federal Communications Commission of the U.S. Government.
The exposure standard employs a unit of measurement known as the Specific Absorption Rate or SAR. The SAR limit set by the FCC is 4 W/kg. Tests for SAR are conducted using standard operating positions accepted by the FCC with the EUT transmitting at the specified power level in different channels.
The FCC has granted Equipment Authorization for this device with all reported SAR levels evaluated as in compliance with the FCC RF exposure guidelines.

(Sec. 15.247)
This device complies with FCC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter
(Sec. 15.19)
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation

(Sec. 15.21)
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

PRODUCT OUTLOOK

Medical-Intubation-W4239-Wi-Fi-Articulation-Videoscope-
FIG-1

Software(APP)
“Videoscope i2” is a specifically designed APP for the “W4239 Wi-Fi articulation videoscope” usages. It provides an instinctive user interface of convenient operations: LED light adjustment, snapshot, recording, and photo album linkage.
NOTE OS Support- iOS 10 above. Android 4 above.

Connection mobile to the main system

Step 1. Install the “Videoscope i2” APP from Android Google Play or Apple APP Store.

Step 2. Connect main system to mobile device:

Medical-Intubation-W4239-Wi-Fi-Articulation-Videoscope-
FIG-3

NOTE The main console power-on and system boot process may take 10~20 seconds.
Generally, the tip LED turns on when the system boot is complete and ready for use.

Step 3. Launch the “Videoscope i2” APP

Functions & user interface

Main screen_ Landscape

Medical-Intubation-W4239-Wi-Fi-Articulation-Videoscope-
FIG-5

Function / Icon Description
LED light control Touch & drag the LED brightness control bar
Snapshot/ Record Tap the camera icon to switch snap shot/record mode
Album Link to the original photo album of Android/iOS devices of the

“Videoscope i” folder
Fullscreen| Hide the 2 side control function. Preview image scaling to full- screen

Main screen: Portrait

Main screen: record mode

Medical-Intubation-W4239-Wi-Fi-Articulation-Videoscope-
FIG-7

SPECIFICATIONS

  • Model name: W4239 Wi-Fi articulation video scope
  • Model no: W4239

W4239 Console

Dimensions| 18767.860.5 (mm) ( w/o insert probe)
Weight| 365g
Still image format| 1280720 JPG (on mobile device storage)
Video resolution format| 1280
720 AVI (on mobile device storage)
Battery(*)| 4900 mAh Li-ion battery. Up to 6 hours of typical operation. 2 hours of charging
Power source| DC in 5V 3A, Type C, USB compatible
Wi-Fi| IEEE 802.11 b/g/n, 2.4Ghz
Antenna| Built-in
Transmission distance| 0~10m (Typical open space)
Button| Power/Photo+Video/LED Adjus
Power indicator| Power on-green Low power-orange/red Charging-red Full

charged-none.

Working temperature| 0°C ~ 45°C
Drop Resistance| Probe 1.5 m / Main Unit 1 m
Certification| CE/FCC/TELEC/NCC
Probe
Probe head diameter| 3.9 mm
Probe head length| 17 mm
Probe length| 1.5 m (**)
Articulation angle| 2 way180°
Probe head material| stainless steel
Probe material| outer braided stainless steel
Light source| Front
FOV| 90°
DOF| 10mm~100mm
Working temperature| -10°C ~ 60°C (***)
Storage temperature| -10°C ~ 60°C
Waterproof(Tip side)| IP67

  • Recommend to turn off and charge the battery once the LOW BATTERY red lights up. Low battery and plugging the power adaptor might cause Wi-Fi connection malfunction
  • The maximum articulation angle may degrade over time
  • High temperature during charging/operation may cause battery degradation of performance and life

Cautions for Use

Medical-Intubation-W4239-Wi-Fi-Articulation-Videoscope-
FIG-16 Medical-
Intubation-W4239-Wi-Fi-Articulation-Videoscope-FIG-17 Medical-Intubation-W4239-Wi-Fi-Articulation-
Videoscope-FIG-18 Medical-
Intubation-W4239-Wi-Fi-Articulation-Videoscope-FIG-19

TROUBLESHOOTING

No. Trouble Condition Solution
1 Cannot find the W4239 device on the Wi-Fi network list. ●  Reboot the main

system console.

●  Restart the mobile Wi-Fi again.

●  Contact your local provider if it still cannot work.

2| The W4239 is already on the Wi-Fi network list but cannot link to it.| ● Restart the mobile Wi-Fi again.

●  Try to clean the Wi-Fi network setting temporary files:

Android-

(1) get to the ‘settings->Wi-Fi’

(2) Long tap the device SSID: W4239

(3) chose ‘clean’

The steps may vary for different mobile phones. Please refer to your original mobile phone instructions.

iOS-

settings > general > reset > reset networks

●  Contact your local provider if it still cannot work.

3| “Connection Failed” message on the APP screen during use.| ●  Check the power status of the console.

●  Tap ‘try again’. The live image will recover in about 20 seconds.

●  Contact your local provider if it still cannot work.

4| Wi-Fi connection and image| ●  Reboot the main system console.

●  Check the power status of the console.

●  Contact your local provider if it still cannot work.

5| Wi-Fi connection and image| ●  Check the app’s latest version.

●  Reboot the main system console.

●  Restart the mobile Wi-Fi again.

●  Reboot the APP.