MRCOOL Olympus Hyper Heat Series Ductless Mini Split Heat Pump AC User Manual

June 17, 2024
MrCOOL

MRCOOL Olympus Hyper Heat Series Ductless Mini Split Heat Pump AC

MRCOOL-Olympus-Hyper-Heat-Series-Ductless-Mini-Split-Heat-Pump-AC-
PRODUCT

Product Information

Specifications:

  • Model No.:
    • Indoor Unit: O-09-HP-WMAH-230B
    • Outdoor Unit: O-HH-09-HP-C-230B
  • Best Features:
    • Leakage Detection
    • Smartphone App
    • Enhanced Heating
  • Quiet Running
  • DC Inverter
  • Net Dimensions (Indoor Unit): 33.66 x 9.09 x 11.69 inches
  • Net Dimensions (Outdoor Unit): 31.69 x 12.99 x 21.81 inches
  • Packing Dimensions (Indoor Unit): 36.22 x 12.20 x 14.57 inches
  • Packing Dimensions (Outdoor Unit): 36.02 x 14.57 x 24.21 inches
  • Net Weight (Indoor Unit): 22.71 lbs
  • Net Weight (Outdoor Unit): 74.07 lbs
  • Gross Weight (Indoor Unit): 28.88 lbs
  • Gross Weight (Outdoor Unit): 80.25 lbs
  • Refrigerant R-410A: 41.62 oz
  • Piping Size (Liquid Side/Gas Side): 1/4 – 3/8 inch

Product Usage Instructions

Installation:
To install the product, follow these steps:

  1. Choose a suitable location for the indoor and outdoor units.
  2. Ensure proper electrical connections are available.
  3. Mount the indoor unit on the wall using the provided brackets.
  4. Connect the indoor unit to the outdoor unit using the recommended piping size.
  5. Make sure to follow all local building codes and regulations.

Operation:
To operate the product, follow these steps:

  1. Turn on the power supply.
  2. Use the smartphone app or remote control to set the desired temperature and mode (heating or cooling).
  3. The product will start heating or cooling according to the selected settings.
  4. Adjust the fan speed and direction as needed for optimal comfort.

Maintenance:
To maintain the product and ensure its longevity, follow these steps:

  1. Regularly clean the air filters to remove dust and debris.
  2. Inspect the outdoor unit for any obstructions or debris and clean if necessary.
  3. Check for any leaks or abnormal sounds during operation and contact a technician if needed.
  4. Schedule regular maintenance visits with a qualified technician to ensure optimal performance.

Frequently Asked Questions (FAQ):

Q: What is the refrigerant used in this product?
A: The refrigerant used is R-410A.

Q: What are the net dimensions and weight of the indoor and outdoor units?
A: The net dimensions and weight are as follows:

  • Indoor Unit:
    • Dimensions: 33.66 x 9.09 x 11.69 inches
    • Weight: 22.71 lbs
  • Outdoor Unit:
    • Dimensions: 31.69 x 12.99 x 21.81 inches
    • Weight: 74.07 lbs

Q: How do I control the product?
A: You can control the product using the smartphone app or the provided remote control.

Q: How often should I clean the air filters?
A: It is recommended to clean the air filters every month to maintain optimal performance.

Q: Can I install the product myself?
A: While it is possible to install the product yourself, it is recommended to hire a qualified technician for proper installation and to ensure warranty coverage.

Superior Heating Saves you money Supreme efficiency Low ambient cooling

Best Features

MRCOOL-Olympus-Hyper-Heat-Series-Ductless-Mini-Split-Heat-Pump-
AC-1

Specification

MODEL NO.                         Indoor Unit| O-09-HP-WMAH-230B| O-12-HP- WMAH-230B| O-18-HP-WMAH-230B| O-24-HP-WMAH-230B
---|---|---|---|---
Outdoor Unit| O-HH-09-HP-C-230B| O-HH-12-HP-C-230B| O-HH-18-HP-C-230B| O-HH-24-HP-C-230B

CAPACITY & PERFORMANCE

Cooling Capacity Btu/h 9000 12000 18000 24000
SEER2 Btu/W 28.1 25.5 21.5 21.5
EER2 Btu/W 16.2 14.0 12.5 13.0
Heating Capacity Btu/h 12000 12000 18000 29000
HSPF2-4   11.5 10.4 11.3 11.4
HSPF2-5   9.0 8.0 8.3 9.2
Indoor noise level (Hi/Mi/Lo) dB(A) 38/33.5/23.5 38/33.5/23.5 46/42/24

46/39/34
Outdoor noise level| (dB(A)| 54.5| 56| 59| 62

ELECTRICAL PARTS

Power Supply| V~Hz, Ph| 208/230~60, 1| 208/230~60, 1| 208/230~60, 1| 208/230~60, 1
---|---|---|---|---|---
Indoor Minimum Circuit (Disconnect)| A| 3.0| 3.0| 3.0| 3.0
Indoor Maximum Fuse (Breaker)| A| 15.0| 15.0| 15.0| 15.0
Outdoor Minimum Circuit (Disconnec| t) A| 15.0| 15.0| 20.0| 25.0
Outdoor Maximum Fuse (Breaker)| A| 15.0| 15.0| 25.0| 35.0

DIMENSIONS & WEIGHT

Net Dimension

(WxDxH)

| Indoor| inch| 33.66 x 9.09 x 11.69| 33.66 x 9.09 x 11.69| 40.28 x 9.65 x 12.56| 47.09 x 10.98 x 14.57
---|---|---|---|---|---|---
Outdoor| inch| 31.69 x 12.99 x 21.81| 31.69 x 12.99 x 21.81| 35.04 x 13.46 x 26.50| 37.24 x 16.14 x 31.89
Packing Dimension

(WxDxH)

| Indoor| inch| 36.22 x 12.20 x 14.57| 36.22 x 12.20 x 14.57| 43.11 x 12.80 x 15.75| 50.39 x 14.17 x 17.91
Outdoor| inch| 36.02 x 14.57 x 24.21| 36.02 x 14.57 x 24.21| 39.17 x 15.67 x 29.13| 42.91 x 19.69 x 34.84
Net Weight| Indoor| lbs| 22.71| 22.93| 27.12| 43.65
Outdoor| lbs| 74.07| 73.63| 100.97| 134.48
Gross Weight| Indoor| lbs| 28.88| 28.88| 35.71| 54.89
Outdoor| lbs| 80.25| 79.37| 108.03| 144.40

REFRIGERANT & PIPING

MRCOOL-Olympus-Hyper-Heat-Series-Ductless-Mini-Split-Heat-Pump-
AC-2

†Starting charge does not guarantee line charge.
Running pressure must be checked by a technician.
WWW.MRCOOL.COM

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

MrCOOL User Manuals

Related Manuals