WARNING
The appliance must not be installed behind a decorative door to avoid overheating. To avoid any potential hazard, you must follow our instructions when you install your appliance. Failure to install the appliance correctly could invalidate any warranty or liability claims and lead to prosecution.

Use an authorized person
As stated in the local municipal building codes and other relevant statutory regulations:

  • Wiring connections must be by AS/NZS 3000 Wiring Rules and any particular conditions of the local authority.
  • Refer to the data plate for rating information. The data plate is positioned behind the bottom of the oven door.
  • For appliances with open cooking surfaces, a disconnect functional switch should be provided near the appliance in an accessible position. Refer to AS/NZS 3000 clause 4.7.1
  • Wiring should be protected against mechanical failure. Refer to AS/NZS3000 clauses 3.3.2.6, 3.9, 3.10
  • A means of disconnection with a contact separation of at least 3mm must be supplied in the fixed wiring.
  • This appliance must be connected with a cable of 75°C rating minimum.
  • This product has passed the insulation resistance test after manufacture. If the resistance reading is low at installation, it is probably caused by moisture from the atmosphere being absorbed by the elements after the appliance has been produced.(pass at 0.01MΩ  AS/NZS 3000 Wiring Rules Clause 8.3.6.2).

WARNING
This appliance must be properly earthed.

  • Do not lift the appliance by the door handles.
  • Prepare the cupboard opening to match your appliance measurements. (See diagrams)
  • Slide the appliance into the cupboard, ensuring that the supply cable (where fitted) does not kink.
  • To prevent tipping, use the screws supplied to secure your appliance into the cupboard by fastening through the 4 holes to the front panel.
  • Where the appliance is built into a cabinet, the cabinet must be capable of withstanding 70°C. Installation into low-temperature tolerant cabinetry (e.g. vinyl coated) may result in deterioration of the low-temperature coating by discolouring or bubbling.
  • If the appliance is to be installed adjacent to vinyl-wrapped surfaces, use an installation kit available from the vinyl-wrap supplier.
  • Electrolux Home Products cannot accept responsibility for damage caused by installation into low-temperature tolerant cabinets.
  • After installation, test and ensure that the appliance operates correctly before handing it over to the customer.

NOTE: If a powerpoint is fitted it must be accessible with the appliance installed, as the plug must be accessible after installation.

Cabinet construction for your appliance
For the best integration within a kitchen, install this appliance in a standard 600mm wide cupboard that gives a flush fit (Figure A) with the surrounding cupboard fronts. Non-pyrolytic appliances can also be installed using a proud fit (Figure B).

IMPORTANT
For all Pyrolytic clean models, the oven must be installed as a flush fit (Figure A) to the surrounding cupboards, and the “infill panel” MUST not exceed 100mm in length. This ensures a 16mm gap is maintained between the cabinet and the side of the appliance to prevent the cupboard from overheating.

Figure A – Flush Fit

Figure B – Proud Fit

NOTE: Your appliance must be mounted on a flat horizontal surface for the full width and depth of the product

Levelling oven
Place a level in the oven as below making sure the level sits on the front and rear forms. The level needs to be correct to prevent slides from moving in or out with gravity.Electrolux-EVEP616-Built-in-Oven-
FIG-3

To access your detailed user manual simply scan the QR code on your smartphone or visit electrolux.com.au/support/manuals/

Underbench oven
Your underbench oven looks best when the control panel is directly under the benchtop. An upper infill panel may be added if the cooktop placed above the benchtop is too deep. Refer to cooktop installation instructions for required clearance between the cooktop and oven.

IMPORTANT!

Note: Dimension’D’* A requirement for all EVEPxxxx pyrolytic clean ovens and all Duo ovens – for proper ventilation there MUST be a gap at the bottom rear of the cabinet. This can be a full-width opening 20mm deep. Refer to dimension “D” in the relevant diagram. The powerpoint connection for the oven must be accessible with the appliance fully installed. If the supply cord is damaged it must be replaced by the manufacturer, its service agent, or similarly qualified persons to avoid a hazard.

Cut-out dimensions

Electrolux-EVEP616-Built-in-Oven-FIG-5

Double oven cut-out dimensions

Electrolux-EVEP616-Built-in-Oven-FIG-6

Pyrolytic under-bench cut-out dimensions

Electrolux-EVEP616-Built-in-Oven-FIG-7

Duo oven cut-out dimensions

Electrolux-EVEP616-Built-in-Oven-FIG-8

Technical specifications

Electrolux-EVEP616-Built-in-Oven-FIG-9

Hardwiring details

  1. Remove the terminal cover plate from the rear panel of the appliance.
  2. Fit wires through holes in the cover plate and make connections to terminals.
  3. Engage wires into the plastic clip. Secure plastic clip with two long silver screws (supplied in separate bag).
  4. Replace the cover plate on the ear panel.