Product Specifications
Model No.| HV1007GU1OT| HV1017GU1OT| HV1027GU1OT| HV1037GU1OT| HV1047GU1OT|
HV1087GU1OT| HV1097GU1OT
---|---|---|---|---|---|---|---
Name| Tivah
Material| 316 Stainless Steel| Solid Copper| Aluminium| Aluminium| Aluminium|
Aluminium| Solid Brass
Colour| Stainless Steel| Copper| Black| White| Silver| Titanium| Antique Brass
IP Rating| IP65
Input Voltage| 240v AC
Lamp Base| GU10
Lamp Wattage| 2x 5w
Colour Temp| TRI Colour – 3000k, 4000k, 5500k
Lumens| 2x 2701m, 2x 2851m, 2x 3001m
CRI| > 80
Wiring| Parallel
Dimmable| No (with globes supplied)
Warranty| 2 Years Replacement*
Dimensions:
Important Safety Issues:
-
This product must be installed by a qualified electrician according to AS/NZS 3000.
-
Ensure all electrical mains are disconnected before any installation.
-
Do not exceed maximum wattage restrictions for globes: 240V GU10 = 35w / 12V MR16 = 20w
-
Modification of this product will void any warranty.
-
Havit Lighting does not take responsibility for wrong installation, incorrect use, or use of installation material that does not belong to the system.
-
When installing low voltage fittings, Voltage to fitting must be within +or- 5% of voltage required, if not within this allowance warranty will be voided.
-
Aluminium and 304SS fittings must not be installed within 2km of any salt water environments.
-
When installing copper fittings, gloves must be worn to avoid any oils transferring to fitting.
-
All 316 stainless steel fittings must have regular cleaning maintenance to avoid any tea staining from forming on fitting.
(Warranty does not cover Tea Staining) -
All o-rings and seals must be in place correctly to maintain warranty.
-
These instructions may be updated at any time due to product improvements, Please visit website for most current installation instructions.
Steps for Installation:
-
Make sure that the electrical circuit is free of voltage (master switch off )
-
Loosen allen screws on side of base and seperate mounting bracket from fitting.
-
Install the backing plate securely using appropriate screws for application, Seal all holes in the backing plate including cable entry and screw holes.
Failure to do so will void warranty. -
Connect the cable – use wire with earth; connect the earth first, then live and neutral wire
-
Affix the fiiting to the mounting bracket and tighten allen screws, making sure these are tight to avoid any water penetration.
-
Apply silicon seal around the whole base plate to avoid any water getting into electrical connections.
-
Colour temperature is preset to 3000k, to change remove covers from the fitting by twisting anti-clockwise and setting aside. Remove globes and select desired colour temperature by moving switch on side of the globe and reinserting globes into lampholders.
-
Reattach covers by turning clockwise making sure the seals are still in place and caps are tight to avoid any water penetration.
-
All connections must be carried out carefully, inspect all contacts before switching back on the electric circuit.
Steps for Changing Globe:
- Remove the cover by twisting anti-clockwise and set aside, remove globe by also twisting anti-clockwise.
- Re-insert the appropriate globe by inserting the 2 circular pins into the lampholder and twisting clockwise. (Make sure not to exceed max wattage, see product label for correct info)
- Reattach cover by turning clockwise making sure the seals are still in place and caps are tight to avoid any water penetration.
Tivah Up & Down 5w MR16 Installation Instructions
Product Specifications
Model No.| HV1007MR16T| HV1017MR16T| HV1027MR16T| HV1037MR16T| HV1047MR16T|
HV1087MR16T| HV1097MR16T
---|---|---|---|---|---|---|---
Name| Tivah
Material| 316 Stainless Steel| Solid Copper| Aluminium| Aluminium| Aluminium|
Aluminium| Solid Brass
Colour| Stainless Steel| Copper| Black| White| Silver| Titanium| Antique Brass
IP Rating| IP65
Input Voltage| 12v DC
Lamp Base| MR16
Lamp Wattage| 2x 5w
Colour Temp| TRI Colour – 3000k, 4000k, 5500k
Lumens| 2x 2701m, 2x 2851m, 2x 3001m
CRI| > 80
Wiring| Parallel
Dimmable| No (with globes supplied)
Warranty| 2 Years Replacement*
Dimensions:
Important Safety Issues:
- This product must be installed by a qualified electrician according to AS/NZS 3000.
- Ensure all electrical mains are disconnected before any installation.
- Do not exceed maximum wattage restrictions for globes: 240V GU10 = 35w / 12V MR16 = 20w
- Modification of this product will void any warranty.
- Havit Lighting does not take responsibility for wrong installation, incorrect use, or use of installation material that does not belong to the system.
- When installing low voltage fittings, Voltage to fitting must be within +or- 5% of voltage required and cannot be installed more than 25m from LED Driver, if not within this allowance warranty will be voided.
- Aluminium and 304SS fittings must not be installed within 2km of any salt water environments. When installing copper fittings, gloves must be worn to avoid any oils transferring to fitting.
- All 316 stainless steel fittings must have regular cleaning maintenance to avoid any tea staining from forming on fitting. (Warranty does not cover Tea Staining)
- All o-rings and seals must be in place correctly to maintain warranty.
- These instructions may be updated at any time due to product improvements, Please visit
Steps for Installation:
- Make sure that the electrical circuit is free of voltage (master switch off )
- Loosen allen screws on side of base and separate mounting bracket from fitting.
- Install the backing plate securely using appropriate screws for application, Seal all holes in the backing plate including cable entry and screw holes. Failure to do so will void warranty.
- Connect the cable – Connect the live and neutral wire to a suitable 12v DC LED Driver – (DO NOT CONNECT DIRECTLY TO 240V POWER)
- Affix the fiiting to the mounting bracket and tighten allen screws, making sure these are tight to avoid any water penetration.
- Apply silicon seal around the whole base plate to avoid any water getting into electrical connections.
- Colour temperature is preset to 3000k, to change remove covers from the fitting by twisting anti-clockwise and setting aside. Remove globes and select desired colour temperature by moving switch on side of the globe and reinserting globes into lampholders.
- Reattach covers by turning clockwise making sure the seals are still in place and caps are tight to avoid any water penetration.
- All connections must be carried out carefully, inspect all contacts before switching back on the electric circuit.
Steps for Changing Globe:
- Remove the cover by twisting anti-clockwise and set aside, remove globe by also twisting anti-clockwise.
- Re-insert the appropriate globe by inserting the 2 circular pins into the lampholder and twisting clockwise. (Make sure not to exceed max wattage, see product label for correct info)
- Reattach cover by turning clockwise making sure the seals are still in place and caps are tight to avoid any water penetration.
9in1 Tivah Up & Down Installation Instructions
Product Specifications
Model No. | HV1005T | HV1015T | HV1025T | HV1035T | HV1045T | HV1085T | HV1095T |
---|---|---|---|---|---|---|---|
Name | Tivah | ||||||
Material | 316 Stainless Steel | Solid Copper | Aluminium | Aluminium | Aluminium | ||
Aluminium | Solid Brass | ||||||
Colour | Stainless Steel | Copper | Black | White | Silver | Titanium | Antique Brass |
IP Rating | IP65 | ||||||
Input Voltage | 240v AC | ||||||
Lamp Base | GU10 | ||||||
Lamp Wattage | 2x 3w, 5w, 7w | ||||||
Colour Temp | TRI Colour – 3000k, 4000k, 5500k | ||||||
Lumens | 2x 240-560Im, 2x 255-5951m, 2x 270-6301m | ||||||
CRI | > 80 | ||||||
Wiring | Parallel | ||||||
Dimmable | No (with globes supplied) | ||||||
Warranty | 2 Years Replacement* |
Dimensions:
Important Safety Issues:
-
This product must be installed by a qualified electrician according to AS/NZS 3000.
-
Ensure all electrical mains are disconnected before any installation.
-
Do not exceed maximum wattage restrictions for globes: 240V GU10 = 35w / 12V MR16 = 20w
-
Modification of this product will void any warranty.
-
Havit Lighting does not take responsibility for wrong installation, incorrect use, or use of installation material that does not belong to the system.
-
When installing low voltage fittings, Voltage to fitting must be within +or- 5% of voltage required, if not within this allowance warranty will be voided.
-
Aluminium and 304SS fittings must not be installed within 2km of any salt water environments.
-
When installing copper fittings, gloves must be worn to avoid any oils transferring to fitting.
-
All 316 stainless steel fittings must have regular cleaning maintenance to avoid any tea staining from forming on fitting.
(Warranty does not cover Tea Staining) -
All o-rings and seals must be in place correctly to maintain warranty.
-
These instructions may be updated at any time due to product improvements, Please visit website for most current installation instructions.
Steps for Installation:
- Make sure that the electrical circuit is free of voltage (master switch off )
- Loosen allen screws on side of base and seperate mounting bracket from fitting.
- Install the backing plate securely using appropriate screws for application, Seal all holes in the backing plate including cable entry and screw holes. Failure to do so will void warranty.
- Connect the cable – use wire with earth; connect the earth first, then live and neutral wire
- Affix the fiiting to the mounting bracket and tighten allen screws, making sure these are tight to avoid any water penetration.
- Apply silicon seal around the whole base plate to avoid any water getting into electrical connections.
- Colour temperature and wattage is preset to 3000k and 7w, to change remove covers from the fitting by twisting anti-clockwise and set aside. Remove globes and select desired colour temperature and wattage by moving switches on side of the globe and reinserting globes into lampholders.
- Reattach covers by turning clockwise making sure the seals are still in place and caps are tight to avoid any water penetration.
- All connections must be carried out carefully, inspect all contacts before switching back on the electric circuit.
Steps for Changing Globe:
- Remove the cover by twisting anti-clockwise and set aside, remove globe by also twisting anti-clockwise.
- Re-insert the appropriate globe by inserting the 2 circular pins into the lampholder and twisting clockwise. (Make sure not to exceed max wattage, see product label for correct info)
- Reattach cover by turning clockwise making sure the seals are still in place and caps are tight to avoid any water penetration.
Must be installed by a licensed electrician
Contact Details:
143 Beauchamp Road
Matraville NSW 2036
Australia| Tel: 02 9381 8300
Fax: 02 9666 8881
Email: sales@havit.com.au
Web: www.havit.com.au
Must be installed by a licensed electrician
**Warranty Terms & Conditions*** | Additional Information |
---|---|
https://havit.com.au/pages/warranty-terms-and-conditions |
https://havit.com.au/collections/tivah-up-down-spotlights
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>