ecler IG108 In Ground Loud Speaker User Manual

June 16, 2024
ecler

ecler IG108 In Ground Loud Speaker

Product Information

Specifications

  • System : IG108
  • Effective frequency range: 2 – 8 Kevlar woofer
  • Coverage angle: 1 ACCW silk dome tweeter
  • Power handling: 110dB below the sound pressure level at a specified sensitivity
  • Sensitivity: 26dB below the sound pressure level than that at the direction of maximum level, Average from 1 kHz to 4 kHz
  • Maximum SPL: Measured on-axis, far-field and referenced to 1 meter by inverse square law. Average from 100 Hz to 10 kHz
  • Power options: Calculated from sensitivity and power handling specifications, exclusive of power compression
  • Recommended amplifier power: Tap switch
  • Transducers: In-ground IP65 rated
  • Ways : Security ground bracket
  • Low-frequency driver: Green (RAL 6005)
  • High frequency driver: 360 x 392.5 mm / 14.17×15.95
  • Nominal impedance: 8.5 kg / 18.74 lb
  • Physical : Weight
  • Power type selector: Installation options
  • Environmental: Included accessories

Introduction

Thank you for choosing our Ecler IG108 in-ground loudspeaker! It is VERY IMPORTANT to carefully read this manual and to fully understand its contents before any connection in order to maximize your use and get the best performance from this equipment. To
ensure optimal operation of this device, we strongly recommend that its maintenance be carried out by our authorised Technical Services. All ECLER products are covered by warranty, please refer to www.ecler.com or the warranty card included with this product for the period of validity and conditions.

Assembly and Installation

Before assembling and installing the IG108 in-ground loudspeaker, please follow these instructions:

  1. Choose a suitable location for installation.
  2. Ensure that the area is clear of any obstructions.
  3. Dig a hole in the ground according to the dimensions specified in the manual.
  4. Place the loudspeaker in the hole, ensuring it is properly aligned.
  5. Secure the loudspeaker using the provided security ground bracket.
  6. Connect the necessary cables to the loudspeaker.
  7. Cover the hole with soil, ensuring that the loudspeaker is fully buried.
  8. Test the loudspeaker to ensure proper functionality.

Connections

To make connections to the IG108 in-ground loudspeaker, follow these steps:

  1. Locate the input terminals on the loudspeaker.
  2. Strip the insulation from the ends of your speaker cables.
  3. Insert the bare ends of the cables into the corresponding terminals on the loudspeaker.
  4. Tighten the terminals to secure the connections.
  5. Ensure that all connections are properly made and secure.

FAQ

  • Q: Can I use the IG108 in-ground loudspeaker near water?
  • A: No, it is not recommended to use the loudspeaker near water to prevent any potential hazards.
  • Q : Can I clean the IG108 in-ground loudspeaker with a wet cloth?
  • A: No, it is recommended to clean the loudspeaker only with a dry cloth to avoid any damage.
  • Q: What should I do if the IG108 in-ground loudspeaker stops working?
  • A : If the loudspeaker stops working, please contact our authorised Technical Services for assistance.
  • Q: Can I install the IG108 in-ground loudspeaker near heat sources?
  • A: No, it is not recommended to install the loudspeaker near heat sources such as radiators, heat registers, stoves, or other apparatus that produce heat.
  • Q: How should I dispose of the IG108 in-ground loudspeaker?
  • A: The loudspeaker must not be discarded as unsorted urban waste. Please take it to the nearest electrical and electronic waste treatment centre for proper disposal.

IMPORTANT REMARK

ecler-IG108-In-Ground-Loud-Speaker-fig-8`

WARNING : SHOCK HAZARD – DO NOT OPEN

  • The lightning flash with the arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
  • The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.

WARNING (If applicable): The terminals marked with the symbol of “ ” may be of sufficient magnitude to constitute a risk of electric shock. The external wiring connected to the terminals requires installation by an instructed person or the use of ready-made leads or cords.
WARNING: To prevent fire or shock hazards, do not expose this equipment to rain or moisture.
WARNING: An apparatus with Class I construction shall be connected to a main socket outlet with a protective earthing connection.

IMPORTANT SAFETY INSTRUCTIONS

  1. Read these instructions.
  2. Keep these instructions.
  3. Heed all warnings.
  4. Follow all instructions.
  5. Do not use this apparatus near water.
  6. Clean only with dry cloth.
  7. Do not block any ventilation openings. Install following the manufacturer’s instructions.
  8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
  9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for the replacement of the obsolete outlet.
  10. Protect the power cord from being walked on or pinched particularly at the plugs, convenience receptacles, and at the point where they exit from the apparatus.
  11. Only use attachments/accessories specified by the manufacturer.
  12. Unplug the apparatus during lightening sorts or when unused for long periods.
  13. Refer all servicing to qualified personnel. Servicing is required when the apparatus has been damaged in any way, such as a power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
  14. Disconnecting from mains: When switching off the POWER switch, all the functions and light indicators of the unit will be stopped, but fully disconnecting the device from mains is done by unplugging the power cable from the mains input socket. For this reason, it always shall remain easily accessible.
  15. Equipment is connected to a socket outlet with an earthing connection through a power cord.
  16. The marking information is located at the bottom of the unit.
  17. The apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases, shall be placed on the apparatus.

WARNING: This product must not be discarded, under any circumstance, as unsorted urban waste. Take to the nearest electrical and electronic waste treatment centre

NEEC AUDIO BARCELONA, S.L. accepts no liability for any damage that may be caused to people, animals or objects due to failure to comply with the warnings above.

IMPORTANT NOTE

Thank you for choosing our Ecler IG108 in-ground loudspeaker! It is VERY IMPORTANT to carefully read this manual and to fully understand its contents before any connection in order to maximize your use and get the best performance from this equipment. To ensure optimal operation of this device, we strongly recommend that its maintenance be carried out by our authorised Technical Services. All ECLER products are covered by warranty , please refer to www.ecler.com or the warranty card included with this product for the period of validity and conditions.

INTRODUCTION

The IG108 is an in-ground weatherproof loudspeaker (IP65) with an omnidirectional horizontal dispersion pattern (360º). It is ideal for music and message applications in outdoor areas, where a reliable yet high-quality sound system is required.

  • IP65 outdoor-rated loudspeaker
  • 8 ohm and 70/100 V (7,5, 15, 30 o 60 W tap switch)
  • 8” Kevlar woofer and 1” ACCW silk dome tweeter
  • Frequency response (-10 dB): 50 Hz-23 kHz
  • Omni directional horizontal coverage pattern (a circular area with an average radius of 4 to 6 meters can be covered by one unit, in a standard application)
  • Available in green (RAL 6005)

ASSEMBLY AND INSTALLATION

ecler-IG108-In-Ground-Loud-Speaker-fig-5

ecler-IG108-In-Ground-Loud-Speaker-fig-6

CONNECTIONS

ecler-IG108-In-Ground-Loud-Speaker-fig-6

TECHNICAL CHARACTERISTICS

IG108 __

System
Effective frequency range1| 50 Hz-23 kHz
Coverage angle2| 360°x229° (HxV)
Power handling| 100 W RMS / 400 W Peak
Sensitivity3| 92 dB (1W/1m)
Maximum SPL4| 112 dB continuous / 118 dB peak
Power options| 100V: 60W / 30W / 15W / 7,5W / 8Ω

70V: 30W / 15W / 7,5W / 3,75W / 8Ω

Recommended amplifier power| 200 W RMS
Transducers|
Ways| 2
Low frequency driver| 8″ Kevlar woofer
High frequency driver| 1″ ACCW silk dome tweeter
Nominal impedance| 8Ω
Physical|
Power type selector| Tap switch
Installation options| In-ground
Environmental| IP65 rated
Included accessories| Security gound bracket
Finished colour| Green (RAL 6005)
Dimensions (ØxD)| 360 x 392.5 mm / 14.17″x15.95″
Weight| 8.5 kg / 18.74 lb

  • 10dB below the sound pressure level at a specified sensitivity
  • 26dB below the sound pressure level than that at the direction of maximum level, Average from 1 kHz to 4 kHz.
  • 3Measured on-axis, far-field and referenced to 1 meter by inverse square law. Average from 100 Hz to 10 kHz.
  • 4Calculated from sensitivity and power handling specifications, exclusive of power compression

All product characteristics are subject to variation due to production tolerances. NEEC AUDIO BARCELONA S.L. reserves the right to make changes or improvements in the design or manufacturing that may affect these product specifications.
For technical queries contact your supplier, or distributor or complete the contact form on our website,
in Support / Technical requests. Motors, 166-168 08038

contact

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ecler User Manuals

Related Manuals