  • The safe operation of this appliance can only be guaranteed if it has been installed to a professional standard by these installation instructions. The installer shall be liable for any damage resulting from incorrect installation.
  • Check the appliance for damage after unpacking it. Do not connect the appliance if it has been damaged in transit.
  • Proceed by the installation sheets for installing accessories.
  • Before starting up the appliance, remove any packaging material and adhesive film from the cooking compartment and the door.
  • Fitted units must be heat-resistant up to 90 °C, and adjacent unit fronts up to 70 °C.
  • Do not install the appliance behind a decorative door or the door of a kitchen unit, as this may cause the appliance to overheat.
  • Any cut-outs that need to be made in the units should be made before the appliance is installed. Remove any shavings, as they may prevent the electrical components from working properly.
  • Wear protective gloves so that you do not cut yourself. Parts that are accessible during installation may have sharp edges.
  • The main socket for the appliance must either be located in the hatched area A or outside of the area where the appliance is installed.
  • Secure any unsecured units to the wall using a standard bracket
  • The dimensions in the figures are in mm.

Wearers of electronic implants!

  • The appliance may contain permanent magnets which may affect electronic implants, e.g. heart pacemakers or insulin pumps.
  • Therefore, during installation, wearers of electronic implants must maintain a minimum distance of 10 cm from the appliance.

Appliance under worktop

fig. 2

To ventilate the appliance, the intermediate floor must have a ventilation cut-out.

Secure the worktop to the fitted units

If the appliance is installed under a hob, the following minimum dimensions must be adhered to (including substructure, if applicable):

The minimum worktop thickness a is based on the required minimum clearance b. Proceed in accordance with the installation instructions for the hob.

Appliance in a tall unit

Fig. 3

  • To ventilate the appliance, the intermediate floors must have a ventilation cut-out.
  • If the tall unit has another back panel in addition to the element back panels, this must be removed.
  • Only fit the appliance up to a height that allows accessories to be easily removed.

Corner installation

Fig. 4

To ensure that the appliance door can be opened in a corner installation, take into account dimension C. Dimension D is dependent on the thickness of the unit front under the handle.

Siemens-iQ700-HB674GBS1-Built-in-Oven \(4\)

Connecting the appliance to the electricity supply

  • The appliance corresponds to protection class 1 and must only be operated with a protective earth connection.
  • The fuse protection must correspond to the power rating specified on the appliance’s rating plate and to local regulations
  • The appliance must be disconnected from the power supply whenever installation work is being carried out.
  • The appliance must only be connected with the power cable provided. Connect the power cable to the back of the appliance (listen for the click).
  • A 3 m power cable can be obtained from the after-sales service.
  • The power cable must only be replaced with a cable from the original manufacturer, which can be obtained from the after-sales service.
  • When the appliance is installed, protection must be provided against accidental contact in the future.

Power cable with a plug with earthing contact

  • The appliance must only be connected to an earthing contact socket that has been correctly installed. If the plug can no longer be reached after the installation, a partition must be provided in the phases in the permanent electrical installation in accordance with the installation regulations.

Power cable without a plug with earthing contact

  • Only allows a licensed professional to connect the appliance.
  • In the permanent electrical installation, a partition must be provided in the phases by the installation regulations. Identify the phase and neutral conductors in the socket. The appliance may be damaged if it is not connected correctly.
  • Only connect the hob according to the connection diagram. See the rating plate for the voltage. Connect the wires of the mains power cable according to the color coding: Green/yellow = PE conductor , blue = neutral conductor, brown = live (external conductor)

Only in Sweden, Finland, and Norway

  • The appliance can also be connected to the earthing contact system using the enclosed plug. This must be accessible after installation. If the plug can no longer be reached after the installation, a partition must be provided in the phases in the permanent electrical installation in accordance with the installation regulations.

Securing the appliance

Fig. 5

Siemens-iQ700-HB674GBS1-Built-in-Oven \(5\)

  1. Fully insert the appliance and center it.
  2. Screw the appliance into place.
    • The gap between the worktop and the appliance must not be sealed by additional strips.
    • Thermal insulation strips must not be fitted to the side panels of the surround unit.

Removal

  1. Disconnect the appliance from the power supply.
  2. Undo the securing screws.
  3. Lift the appliance slightly and then pull it out completely.

Frequently Asked Questions

What is the Siemens iQ700 HB674GBS1 Built-in Oven known for?

The Siemens iQ700 HB674GBS1 Built-in Oven is known for its advanced features, precise cooking capabilities, and sleek design.

What are the dimensions of the Siemens iQ700 HB674GBS1 oven?

The dimensions are specified in the installation manual, but they can be found in the product documentation.

Does the Siemens iQ700 HB674GBS1 oven require professional installation?

Yes, professional installation is recommended to ensure safety and proper functionality.

Is the Siemens iQ700 HB674GBS1 oven compatible with electronic implants, like pacemakers?

The appliance may contain permanent magnets that can affect electronic implants, so wearers should maintain a minimum distance of 10 cm during installation.

Can I install the Siemens iQ700 HB674GBS1 oven behind a decorative door?

No, it should not be installed behind a decorative door or the door of a kitchen unit to prevent overheating.

What precautions should I take when installing the Siemens iQ700 HB674GBS1 oven?

Wear protective gloves to avoid injury from sharp edges during installation.

What type of electrical connection does the Siemens iQ700 HB674GBS1 oven require?

The appliance must be connected with a protective earth connection and the correct fuse protection as specified in the installation instructions.

Can I replace the power cable of the Siemens iQ700 HB674GBS1 oven with any cable?

No, it should only be replaced with a cable from the original manufacturer.

Is there a ventilation requirement for the Siemens iQ700 HB674GBS1 oven?

Adequate ventilation is necessary, and ventilation cut-outs may be required depending on the installation type.

Can I connect the Siemens iQ700 HB674GBS1 oven to an earthing contact socket after installation?

If the plug can no longer be reached after installation, a partition must be provided in the phases according to installation regulations.

Can thermal insulation strips be added to the side panels of the surround unit for the Siemens iQ700 HB674GBS1 oven?

No, thermal insulation strips should not be fitted to the side panels of the surround unit.

How do I remove the Siemens iQ700 HB674GBS1 oven for maintenance or replacement?

To remove the oven, disconnect it from the power supply, undo the securing screws, lift it slightly, and then pull it out completely.

Download The PDF link:Siemens iQ700 HB674GBS1 Built-in Oven Installation Instructions

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals