KURTH ELECTRONIC KE7200 Network and LAN Cable Tester
Product Information
Specifications:
- Model: KE7200
- Powered by: Gossen Metrawatt
- Operating Instructions: 3-447-204-03 1/8.23
Description:
The KE7200 Network and LAN Cable Tester is a versatile instrument designed for
testing network and LAN cables. It is available in different models, including
the KE7200 PRO Kit and the
KE7010 Kit. The instrument is equipped with a remote unit for convenient
testing. It is manufactured by Gossen Metrawatt GmbH, a reputable company
known for its high-quality products.
Safety Precautions:
For proper and safe use of the KE7200 Network and LAN Cable Tester, it is
important to read and follow the provided instructions carefully. These
instructions should be provided to every user of the instrument. The following
safety precautions should be adhered to:
- Handle the instrument with care to avoid damage or injury.
- Operate the instrument under suitable conditions to ensure accurate measurements.
- Use appropriate batteries for power supply.
- Follow proper procedures for measurement cables and establishing contact.
- Ensure data security by complying with applicable regulations and preventing unauthorized access to stored data.
Application:
The KE7200 Network and LAN Cable Tester is primarily intended for testing
network and LAN cables. It is suitable for professional use in various
industries such as IT, telecommunications, and network installation. The
instrument provides reliable results for cable continuity, wiring faults, and
other related parameters.
Intended/Proper Use:
The KE7200 Network and LAN Cable Tester should be used according to the
instructions provided in the instrument operating manual. It is designed for
testing network and LAN cables, ensuring their proper functionality and
identifying any faults or issues. The instrument can be used for both
troubleshooting and regular maintenance purposes.
Improper Use:
Using the KE7200 Network and LAN Cable Tester for purposes other
than those described in the operating instructions is considered improper use.
It may lead to inaccurate measurements, potential damage to the instrument,
and compromised safety. It is important to strictly adhere to the specified
instructions to ensure optimal performance and longevity of the instrument.
Liability and Guarantee:
Gossen Metrawatt GmbH assumes no liability for any property damage, personal
injury, or consequential damage resulting from improper or incorrect use of
the KE7200 Network and LAN Cable
Tester. It is the user’s responsibility to follow the product documentation
and perform maintenance measures properly and in a timely manner. Warranty
claims will be void in case of improper use, and Gossen Metrawatt GmbH does
not assume any liability for lost data.
Instructions:
These instructions provide detailed information on safely using the KE7200
Network and LAN Cable Tester. It is important to carefully read and follow
these instructions to protect yourself, others, and the instrument from
potential harm or damage. The latest version of these instructions can be
downloaded from the Gossen Metrawatt GmbH website:
https://www.gmc-instruments.de/en/services/download-center/
Description of Various Models:
The documentation includes descriptions of different models and their
combinations, as well as optionally available functions of the KE7200 Network
and LAN Cable Tester. Some functions described may not be applicable to your
specific instrument. Additionally, the illustrations provided in the
documentation may differ from the physical appearance of your instrument.
Errors and Suggestions for Improvement:
While every effort has been made to ensure accuracy and completeness in these
instructions, errors may still occur. Gossen Metrawatt GmbH strives for
continuous improvement and welcomes any suggestions or tips to enhance the
quality of their products and documentation.
Equal Treatment:
The masculine form used in these instructions is intended to improve
readability and should be understood as including all genders and diversities.
Trademark Rights:
Product designations mentioned in this document may be protected by trademark
law, brand law, and patent law. They remain the property of their respective
owners.
Copyright:
This document is protected by copyright. Any modification, reproduction,
duplication, processing, or translation in any form (including excerpts)
requires the written consent of Gossen Metrawatt GmbH. This applies
particularly to storage and processing in electronic systems.
Product Usage Instructions
Handling:
Handle the KE7200 Network and LAN Cable Tester with care to avoid any physical
damage. Ensure that it is kept in a safe and secure location when not in use.
Avoid exposing the instrument to extreme temperatures or humidity that may
affect its performance.
Operating Conditions:
The KE7200 Network and LAN Cable Tester should be operated under suitable
conditions to ensure accurate measurements. Avoid using the instrument in
environments with excessive electromagnetic interference or strong magnetic
fields, as they may affect the test results.
Batteries:
Use the appropriate batteries as specified in the instrument operating manual.
Ensure that the batteries are correctly inserted, observing the polarity
markings. When the battery level is low, replace the batteries with new ones
to maintain reliable operation.
Measurement Cables and Establishing Contact:
When connecting the measurement cables to the KE7200 Network and LAN Cable
Tester, ensure that they are securely attached. Improper cable connection may
lead to inaccurate measurements. Clean the cable connectors and the
instrument’s contact points regularly to maintain good electrical contact.
Data Security:
The KE7200 Network and LAN Cable Tester may store data during testing. It is
important to observe and comply with applicable national data protection
regulations. Take appropriate measures to prevent unauthorized access to the
stored data, such as password protection or encryption.
FAQ (Frequently Asked Questions)
Q: What is the intended use of the KE7200 Network and LAN Cable Tester?
A: The KE7200 Network and LAN Cable Tester is primarily designed for
testing network and LAN cables, ensuring their proper functionality and
identifying any faults or issues.
Q: Can I use the KE7200 Network and LAN Cable Tester for purposes other
than testing cables?
A: No, using the instrument for any purposes other than those described
in the operating instructions is considered improper use and may lead to
inaccurate measurements and potential damage.
Q: Who is responsible for any property damage or personal injury resulting
from improper use of the instrument?
A: Gossen Metrawatt GmbH assumes no liability for any property damage,
personal injury, or consequential damage resulting from improper or incorrect
use of the KE7200 Network and LAN Cable Tester. It is the user’s
responsibility to follow the product documentation and use the instrument
correctly.
Network and LAN Cable Tester
KE7200
KE7200 PRO Kit
Remote Unit
KE7010
KE7010 Kit
KE7010 PRO Kit
Gossen Metrawatt GmbH | Südwestpark 15 | 90449 Nürnberg Germany
Phone +49 911 8602-0 | Telefax +49 911 8602-669
info@gossenmetrawatt.com
www.gossenmetrawatt.com
Safety Precautions
For proper and safe use, please read and follow these instructions carefully
and completely.
The instructions must be provided to every user of the instrument.
Keep for future reference.
General
- The instrument may only be used by adequately trained specialists.
- Observe and comply with all safety regulations applicable for your work environment.
- Wear suitable and appropriate personal protective equipment (PPE) during all work.
- In particular, the relevant safety regulations in VDE 0100, 0800, and 0805 must be adhered to.
Accessories
- Use only the specified accessories (included in delivery or listed as optional) with the instrument.
- Carefully and completely read and adhere to the product documentation for optional accessories.
Retain these documents for future reference.
Handling
-
The instrument may only be used in data and telecommunications networks that are free of external voltages.
External voltages greater than 60 V DC can destroy the instrument and also represent a potential health hazard to the user! -
Never pull unnecessarily on the cables connected to the instrument.
-
Use the instrument in undamaged condition only.
Inspect the instrument before use. Pay particular attention to damage, broken insulation, or kinked cables. -
Use the accessories and all cables in undamaged condition only.
Inspect all cables and accessories before use. Pay particular attention to damage, broken insulation, or kinked cables. -
If the instrument or its accessories do not function flawlessly, permanently remove the instrument/ accessories from operation and secure them against inadvertent use.
-
If the instrument or accessories are damaged during use, such as if they are dropped, permanently remove the instrument/accessories from operation and secure them against inadvertent use.
-
If there are any signs of interior damage to the instrument or accessories (e.g., loose parts in the housing), permanently remove the instrument/accessories from operation and secure them against inadvertent use.
-
The instrument and accessories may only be used for the tests/measurements described in the documentation for the instrument.
Operating Conditions
- Do not use the instrument and its accessories after long periods of storage under unfavorable conditions (e.g., humidity, dust, or extreme temperatures).
- Do not use the instrument and the accessories after extraordinary stressing due to transport.
- Do not expose the instrument to direct sunlight.
- Only use the instrument and the accessories in compliance with the specified technical data and under the specified conditions.
- Do not use the product in potentially explosive atmospheres. Danger of explosion!
Batteries
-
Use batteries in undamaged condition only. There is a risk of explosion and fire if the batteries are damaged!
-
Inspect the batteries before use. Pay particular attention to leaky and damaged batteries.
-
Only use the instrument with the battery compartment lid inserted and closed.
Measurement Cables and Establishing Contact -
Never touch conductive ends or wires.
-
Make sure that good contact has been made.
Data Security
- Always create a backup copy of your measurement data.
- The instrument is equipped with a data memory to which personal and/or sensitive data can be stored. Observe and comply with the applicable national data protection regulations.
Take appropriate measures to prevent unauthorized access to the data.
Application
Please read this important information!
Intended/Proper Use
The KE7200 is a network and LAN cable tester.
It is used for initial startup tests, for checking data and telecommunications
networks, and for troubleshooting. The results can be stored in the instrument
or transferred to a PC. In the associated PC software, the results can be
documented and logs created.
The instrument is used in data and telecommunications networks (Ethernet/RJ-45
cables, coaxial cables/lines, telecommunications cables/lines) without
external voltage. It is hooked up using its RJ-45 socket and the supplied or
optionally available accessories (see data sheet).
The KE7200 can be used to perform the following tests/measurements:
-
Cable tests with error display:
Detection of reversed connections, short circuits, interruptions, overdrafts (split pairs; as of 2 m), testing of the data line assignment with pin and pair assignment (wire mapping), cable length measurement, and determination of the distance to the error with TDR function -
Network tests (Ethernet cable only):
IP test with listing of active network subscribers with name, IP address, and MAC address; detection of network speed 10/100/1000 Mbit; ping test, including stress tests -
Power over Ethernet test (Ethernet cable only):
PoE/PoE++ test according to IEEE802.3af/at/bt -
Port finder function (Ethernet cable only):
Link blink function for identifying ports on routers/switches/hubs -
Search tone mode (Ethernet cable only):
Transmission of a search tone signal and identification of the associated network port via tone detection with the P310*/P410** probe search signal receiver -
[With software option only] Branch detection (coaxial cables/lines, telecommunications cables/lines only):
For precise localization (existence and distance) of branches/stub lines (bridge taps) in telecommunications networks in buildings.
The external voltage protection of the KE7200 against accidentally applied
external voltage is 60 V DC. The instrument emits a warning and displays
whenever external voltage is present, and tests can only be conducted after
the external voltage has been eliminated.
Some measurements/tests require the KE7010 remote unit or the P310/P410 probe
search signal receiver. For this reason, different instrument combinations are
offered (see scope of delivery and data sheet).
The safety of the user and the instrument is only guaranteed during proper use.
- P310 included in the KE7200 PRO kit; optionally available for purchase separately
- P410 included in KE7207 and KE7208; optional available for purchase separately
Improper Use
Using the instrument for any purposes other than those described in these
instrument operating instructions constitutes improper use.
Liability and Guarantee
Gossen Metrawatt GmbH assumes no liability for property damage, personal
injury, or consequential damage resulting from improper or incorrect use of
the product, in particular due to failure to observe the product
documentation. The same applies to maintenance measures that are not carried
out properly or in good time. Moreover, all warranty claims will be void in
such cases.
Nor will Gossen Metrawatt GmbH assume any liability for lost data.
Instructions
Information on These Instructions
Read these instructions carefully and attentively. They contain all the
information for safely using this instrument. Follow them to protect yourself
and others from injury and to avoid damaging the instrument.
The latest version of these instructions is available on our website:
https://www.gmc-instruments.de/en/services/download-center/
Description of Various Models
This documentation describes the different combinations and optionally
available functions of the instruments. For this reason, functions may be
described that do not apply to your particular instrument. In addition, the
illustrations may differ from your instrument.
Errors and Suggestions for Improvement
These instructions have been prepared with the utmost care to ensure accuracy
and completeness.
Unfortunately, however, errors can never be avoided completely. Continuous
improvement is part of our quality goal, so we are always grateful for tips
and suggestions.
Equal Treatment
For better readability, the masculine form may be used in these instructions
in a grammatically neutral sense. Naturally, the feminine and diverse form are
always understood as being included.
Trademark Rights
Product designations used in this document may be subject to trademark law,
brand law, and patent law. They are the property of their respective owners.
Copyright
This document is protected by copyright. Modification of content,
reproduction, duplication, processing,or translation in any form (including
excerpts) will require the written consent of Gossen Metrawatt GmbH. This
applies in particular to storage and processing in electronic systems.
Scope of Delivery
Please check the scope of delivery for completeness and intactness.
KE7200 (D720A)
KE7200* network tester and 2 KE7010 remote units 2 × short RJ-45 test cords, 1
× long RJ-45 test cord, 1 × RJ-11 test cord to banana plug, including plug-on
crocodile clips, 1 × RJ-45 coax. adapter set (2 × RJ-45 plug adapters to BNC,
2 × BNC plug adapters to F-female), carrying pouch includes KE7200 Manager PC
software (download from website)
KE7200 PRO Kit (D723A)
KE7200* network tester and 4 KE7010 remote units and P310** probe 2 × short
RJ-45 test cords, 1 × long RJ-45 test cord, 1 × RJ-11 test cord to banana
plug, including plug-on crocodile clips, 1 × RJ-45 coax. adapter set (2 ×
RJ-45 plug adapters to BNC, 2 × BNC plug adapters to F-female), carrying pouch
includes KE7200 Manager PC software (download from website)
Branch detection (D720S)
Software option for the KE7200 for the detection of branches / stub lines
(bridge taps) in buildings.
Note: Only included if the software option is part of the order. Alternatively, it can also be ordered later from our service (see”Contact, Support, and Service” on page 26).
KE7010 (D701B)
1 × KE7010 remote unit for KE7200
KE7010 Kit (D701C)
4 × KE7010 remote unit for KE7200
KE7010 PRO Kit (D701D)
4 × KE7010 remote unit for KE7200 and P310** probe
- 4× 1.5 V (AA, LR6, alkaline/mignon) batteries required for operation. Not included with the instrument.
** 9-volt battery required for operation. Not included with the instrument.
Optional Accessories
Some applications require optional accessories. For detailed information,
please refer to the data sheet; these instructions only mention the
accessories required in each case and describe their use.
Instrument Overview
KE7200
Main testing instrument
Instrument Overview
Keypad
- ESC Go back.
- ON / OFF On and off button.
- This button has a delay of approx. 1 sec. when switching off.
- Arrow keys The arrow keys are for scrolling UP ▲ / DOWN ▼ and LEFT ◄ / RIGHT ►.
- SEL SELECT key. Selects a function or starts a test.
Symbols on the Instrument
Warning of a source of danger (please follow documentation!)
European conformity marking
The instrument must not be disposed of in the household trash; see page 27.
KE7010 Remote Unit
Active remote unit with microprocessor
RJ-45 socket
Pass/Fail indication with green LED
A maximum of 32 KE7010 units can be managed and used with the KE7200. To
identify individual KE7010 units, each remote unit can be assigned an ID from
1 –
32. The ID can be written down on the back of the KE7010.
Symbols on the Instrument
Warning of a source of danger (please follow documentation!)
European conformity marking
The instrument must not be disposed of in the household trash; see page 27.
P310 Probe
The P310 probe is a non-contact test loudspeaker that receives the search tone
signal transmitted by the KE7200 and makes it audible.
A flashlight function with a pure white light guarantees clear color
identification of the wire markings in dark server cabinets. The flashlight
turns on automatically when the instrument is on and turns off automatically
when the instrument switches off.
The probe’s test tip is made of fiber-reinforced plastic with a bayonet catch
for easy replacement on site. See data sheet for test tip replacement.
At the lower end of the probe, there is a socket connector for an earphone
(3.5 mm jack plug) to allow signals to be heard more readily.
The probe is switched on and used by holding down the HIGH or LOW keys. The
HIGH position is the most sensitive level for locating weak signals. The LOW
position is for specifying which network port has been found, for example.
The P310 cannot detect the search signal in shielded cables! You will
therefore find the search signal on the associated network port.
The P310 is also part of the EasyTest system for locating cables and wires.
More information is included in the EasyTest product documentation.
Symbols on the Instrument
Warning of a source of danger (please follow documentation!)
European conformity marking
The instrument must not be disposed of in the household trash; see page 27.
Specifications
KE7200
Connections| RJ-45 socket;
Adapter: RJ-45 to coaxial cable, RJ-11 to banana plug, including crocodile clips for banana plug
---|---
Cable Test (Ethernet cable, coaxial cable, telecommunica- tions cable)|
Detection of reversed connections, short circuits, interruptions, split pairs
(as of 2 m), testing of the data line assignment with pin and pair assignment
(wire mapping)
Clear graphical display for fast error identification
TDR function: Measurement of individual wire lengths from 2 m to 200 m
Cable database: 15 wiring versions predefined for cable test and creation of own definitions possible as of 2 wires, including Profinet;
16 cable types predefined with VF for TDR length measurement and creation of own cable types possible
Check for external voltage before test start
Network Tests (Ethernet cable)| IP test
• Connection to the network via DHCP or with static IP (own IP and MAC address configurable)
• List of active network subscribers with name, IP address and MAC address
• Detection of network speed 10/100/1000 Mbit Ping test
• Targeted ping of individual addresses and simultaneous ping stress test
• Ping frame sizes adjustable from 32-1024 bytes
• Display of ping results (received/lost) and response times (min./max./average)
Power over Ethernet Test (Ethernet cable)| Activation of PoE/PoE+/PoE++/LTPoE functions
Measurement of the voltage in V and determination of the power (up to 90 W) according to IEEE802.3af/at/bt
Port Finder Function (Ethernet cable)| Link blink function for identifying ports on routers/switches/hubs:
Transmission of an NLP signal that switches the link LED associated with the port on and off in the same cycle on the most common hubs, switches, or routers.
Tone Mode (telecommunica- tions cable)| Emission of a search tone signal; using the probe search signal receiver, the associated network port can be
clearly identified on the patch panel, etc.
4 search frequencies available for selection: 1000 Hz; 880/1000 Hz; 2600 Hz, and 2600/1900 Hz
Compatible probes: P310 (D130B), P410 (D140B)
Branch Detection (coaxial cable, telecommunica- tions cable)| Precise localization of branches / stub lines (bridge taps) in telecommunications networks in buildings. Determines existence of and distance to the branch / stub line.
Can be purchased as an option.
Additional Functions| • Memory function for 14,000 entries
• Self-test
External Voltage Protection| 60 V DC
Housing| Stable, impact-resistant ABS housing with fall protector
Display| Illuminated display, adjustable time for display backlighting
Power Supply| 4× 1.5 V (AA, LR6, alkaline/mignon) batteries,
with the operating period depending on the test type, the display backlighting duration, and the battery type and condition
Automatic device switch-off (time adjustable)
Dimensions| 195 × 100 mm
Weight| 380 g (without batteries)
Menu Languages| German, English
Operation Environment| Working temperature 0 °C … +50 °C Storage
temperature –25 °C … +75 °C Humidity 90%, non-condensing
KE7010
Function| Active remote unit with microprocessor
Pass/Fail indication with green LED
ID freely programmable from 1-32 (at most 32 KE7010 units can be managed and used by the KE7200)
---|---
Connection| RJ-45 socket
Housing| Stable, impact-resistant ABS housing
Dimensions| 78 × 45 mm
Weight| 30 g
Power Supply| Via RJ-45
Operation Envi- ronment| Working temperature 0 °C … +50 °C Storage
temperature –25 °C … +75 °C Humidity 90%, non-condensing
P310
Function | Traditional search signal receiver (probe) |
---|---|
Features | Filter signal LED Flashlight function |
Test tip made of carbon fiber reinforced plastic
3.5 mm headphone socket Separate battery compartment
Housing| Stable, impact-resistant ABS housing with silicone actuation
keys
Dimensions| 220 × 40/34 × 25 mm
Weight| 80 g without a battery
Power Supply| 9-V battery; approx. 100-hour operating period (depending
on the battery type and condition)
Range| Signal identification occurs directly at the network port (at the
patch panel, router, hub, switch).
Initial Startup
KE7200
The instrument is powered by 4× 1.5 V (AA, LR6, alkaline/mignon) batteries
(not included with the instrument).
Before inserting the batteries, disconnect all test cords and switch off the
instrument. Only use batteries according to the specification.
The battery compartment is located on the back of the instrument. First loosen
the two lower screws of the edge protector (Philips screwdriver required).
Remove the edge protector by pulling it downwards. Insert the batteries. Pay
attention to polarity. Only use batteries of the same type and production
time. Do not mix new and old batteries.
Finally, select the instrument setting for either regular or rechargeable
batteries; see “KE7200 Settings” on page 12 in this regard.
Operating Period
The operating period depends on the test type, the display backlighting
duration, and the battery type and condition.
Measurement always with display backlighting
- Switched on but without a test > approx. 40 hours
- Cable test without a KE7010 remote unit > approx. 35 hours
- Cable test with a KE7010 remote unit > approx. 18 hours
- IP test > approx. 15 hours
The available measuring time can be extended by switching off or limiting the time of the display backlighting.
P310
The instrument is powered by 9-V battery (not included with the instrument).
Switch the instrument off. Only use batteries according to the specification.
The battery compartment is located on the back of the instrument. Open the
battery compartment (Philips PH2 screwdriver required), insert the battery,
and close the battery compartment again.
Self-Test
During the self-test, the KE7200 checks its functionality.
Note: The self-test does not relieve the user of his responsibility to
verify compliance with the safety regulations (page 2).
The option of a self-test is offered during the switch-on process and can be
started by pressing SEL. Then follow the instructions for the self-test.
During the flash test, all data on the device are deleted.
Back up all data beforehand (see page 22) or skip the flash test by pressing
ESC.
If the instrument does not function flawlessly, permanently remove it from
operation and secure it against inadvertent use.
KE7200 Settings
All device settings are made in the menu Settings > Instrument Settings. The
possible operating steps are displayed in the respective menu in the lower
status line.
They are preset to empirical values; there is also a Reset to Factory Settings
function if something does not work as intended when creating cable or wiring
functions.
- Language: Either German (default) or English.
- Unit of Measure: m (meter) or ft (foot).
- Battery Type: The instrument can be powered by either regular or rechargeable batteries (see “Initial Startup” on page 11). Since the voltage of rechargeable batteries is lower, the capacity information can be switched between regular and rechargeable batteries here.
- Backlighting: Switch-on time after each key press in seconds. Set the time with the ▲ or ▼ button, select with SEL.
- Auto Power Off: Time of automatic switch-off of the instrument after the last keystroke. Set with button ▲ or ▼, select with SEL.
- Key Beep: On or Off.
- Acoustic Signal: On or Off. The acoustic signal is issued after the cable measurement.
- Contrast: LCD contrast setting. Set with ▲ or ▼, confirm with SEL.
- Reset to Factory Settings: This returns all settings to the factory default values.
- Program Update: You can updated the firmware/software of your KE7200.
All data are deleted during an update!
The firmware/software depends on your instrument.
The table at https://www.kurthelectronic.de/ke7200-downloads/?lang=en
indicates which firmware/software you need for your KE7200 and lets you
contact our support for the needed update file.
To perform the instrument update, you need the update file (.upd) and the
KE7200 Manager PC software (for more information on the KE7200 Manager, see
page 22).
Connect the KE7200 to the PC, then start the KE7200 Manager there, and select
the Update KE7200 tab. Select the upd file to be installed in the dialog, and
click on Open.
You will now be guided through the process with the Update Information window.
In the KE7200, select Settings > Device Settings
Program Update.
Then press the LEFT ◄ and RIGHT ►keys simultaneously.
The update process will then start. After
approx. 1 minute, the update process will finish and the KE7200 will switch off.
Test/Measurement Settings
In order to perform all tests/measurements correctly, you need to make basic
test settings.
In the Settings menu, you can select the Wiring Type for the test/measurement,
select the Speed (VF factor) for the TDR function, define the Cable Type, and
specify the IP Address of the KE7200.
The Settings > Test Settings submenu provides additional specific test
settings, giving you the possibility of creating own cable and wiring
definitions, managing the KE7010 remote units, and specifying the MAC address
of the KE7200.
Settings > Wiring
Here you can select the desired wiring type from the list of various options
(which PIN for which wire). This can still be changed during the cable test,
however. The specification of the correct wiring type is important, as all
information on the wire pair and PIN assignment is based on this. Without this
information, it will not be possible for an OK statement to be issued by the
test. In addition, only the correct wiring definition will allow a split pair
error message to be sent.
15 common variants are predefined.
The following abbreviations are used:
- UTP= Unshielded Twisted Pair
- STP = Unshielded Twisted Pair
- CR = Cross Connect
Settings > Speed
Here the propagation speed of the signal in the cable, the VF factor, is
entered as a percentage of the speed of light. This information is required
for length measurements with the TDR function.
Only with the correct VF factor will the cable lengths be determined
correctly!
The VF factor predefined for the selected cable type is displayed by default
(for cable selection, see page 14; for cable definitions, see page 14). The
value can also be set manually via the ▲ or ▼ keys.
The data can be obtained from the cable manufacturer. If no information is
available on the cable, the VF factor can also be determined with a piece of
cable of known length.
Determining the VF Value
First conduct the cable test on a piece of cable without the remote unit.
After completion this,go to the Speed menu. Here, the measured length will be
displayed for the set VF. Now adjust using the ▲ or ▼ keys until the known
cable length is displayed. The VF value to be read is the propagation speed of
this cable.
You can use it to create your own cable definition in the Test Settings >
Cable Definition menu.
Settings > Cable
Various frequently used cable types are predefined here (for a list, see page
14). The cable to be tested/measured is selected from the list of different
cables.
The name and the corresponding VF value are assigned to the respective cable
type (see page 14). The cable type name appears in the stored or printed
result. In contrast, the VF value is needed for the TDR function.
You can also add to and change the predefined cable types (see page 14).
Settings > Test Settings
- Cable Definition
The cable definitions are created here with a name and VF value, which can be selected for the cables to be tested/measured (see page 14).
Predefined cable types and associated VF values:
BELD DATATWIST 72%| BELD 3600 PB29 72%| UC300 HS24 S/F 67%| LEONI
E5-70 S/ 80%
---|---|---|---
BELD MEDIATWIST 72%| BELD 4800 PB29 70%| UC500 AS23 F/F 79%| LEONI
F6-80 S/ 80%
BELD 10 GX 68%| DRAKA UC300 67%| UC900 HS23 S/F 79%|
BELD 1200 NP28 72%| DRAKA UC500-15 79%| UC900 SS23 S/F 77%|
BELD 2400 PB28 72%| IS PROFINET 66%| LEON D1-20 SF/ 75%|
Additional cable types can be created as well. Profiles that have already been
created can also be overwritten.
After selecting the cable type to be edited, or alternatively an item without
an entry, select it with SEL. Name:| is displayed. A unique cable name can be
entered here. There are 15 available character slots. At the flashing cursor
position, the ▲ and ▼ keys can now be used to scroll
through the alphabet, all digits 0–9 and an empty position. The digit or
letter to be positioned at the cursor position is selected with SEL. Once the
name has been entered, confirm with SEL.
Speed: xx% will appear. This is the propagation speed in the cable, the VF
value, as a percentage of the speed of light. Enter either the value specified
by the cable manufacturer, the previously determined value, or an approximate
value.
Tip: Phone and Cat3 cables have a value of approx. 64-68, Cat5/6 cables
approx. 72, and Cat6/7 approx. 77.
After entering the VF value, save with SEL. This allows you to quickly and
easily predefine the cable types you use.
Wiring Definition
Correctly selecting the wiring version to be tested is essential for obtaining
good/bad information.
Only if this pin to pair assignment matches can crosstalk be checked reliably.
With the KE7200, not only a wire-to-pin assignment is checked but also whether
the pair assignment is correct. This is done at a high frequency in order to
obtain relevant information.
There are 15 different predefined wiring options to help you make the
selection. The abbreviations UTP, STP, and CR contained therein are described
on page 13. After selecting the Wiring Definition menu item, the Created
Wiring Definitions list will appear:
Name| Pin to pin| Wire pair| Name| Pin to pin|
Wire pair
---|---|---|---|---|---
568A UTP| 1| 1| 3| 568A STP| 1| 1| 3
2| 2| 3| 2| 2| 3
3| 3| 2| 3| 3| 2
4| 4| 1| 4| 4| 1
5| 5| 1| 5| 5| 1
6| 6| 2| 6| 6| 2
7| 7| 4| 7| 7| 4
8| 8| 4| 8| 8| 4
S| NC| | S| S|
568A UTP CR| 1| 3| 3| 568A STP CR| 1| 3| 3
2| 6| 3| 2| 6| 3
3| 1| 2| 3| 1| 2
4| 7| 4| 4| 7| 4
5| 8| 4| 5| 8| 4
6| 2| 2| 6| 2| 2
7| 4| 1| 7| 4| 1
8| 5| 1| 8| 5| 1
S| NC| | S| S|
568B UTP| 1| 1| 2| 568B STP| 1| 1| 2
2| 2| 2| 2| 2| 2
3| 3| 3| 3| 3| 3
4| 4| 1| 4| 4| 1
5| 5| 1| 5| 5| 1
6| 6| 3| 6| 6| 3
7| 7| 4| 7| 7| 4
8| 8| 4| 8| 8| 4
S| NC| | S| S|
568B UTP CR| 1| 3| 2| 568B STP CR| 1| 3| 2
2| 6| 2| 2| 6| 2
3| 1| 3| 3| 1| 3
4| 7| 4| 4| 7| 4
5| 8| 4| 5| 8| 4
6| 2| 3| 6| 2| 3
7| 4| 1| 7| 4| 1
8| 5| 1| 8| 5| 1
S| NC| | S| S|
USOC UTP| 1| 1| 4| USOC STP| 1| 1| 4
2| 2| 3| 2| 2| 3
3| 3| 2| 3| 3| 2
4| 4| 1| 4| 4| 1
5| 5| 1| 5| 5| 1
6| 6| 2| 6| 6| 2
7| 7| 3| 7| 7| 3
8| 8| 4| 8| 8| 4
S| NC| | S| S|
ISDN S BUS| 1| 1| none| TEL 2P UTP| 1| NC| none
2| 2| none| 2| NC| none
3| 3| 2| 3| 3| 2
4| 4| 1| 4| 4| 1
5| 5| 1| 5| 5| 1
6| 6| 2| 6| 6| 2
7| 7| none| 7| NC| none
8| 8| none| 8| NC| none
S| NC| | S| NC|
TEL 1P UTP| 1| NC| none| PROFINET| 1| 1| 1
---|---|---|---|---|---|---|---
2| NC| none| 2| 2| 1
3| NC| none| 3| 3| 2
4| 4| 1| 4| NC| none
5| 5| 1| 5| NC| none
6| NC| none| 6| 6| 2
7| NC| none| 7| NC| none
8| NC| none| 8| NC| none
S| NC| | S| S|
PROFINET CR| 1| 3| 1| | | |
---|---|---|---|---|---|---|---
2| 6| 1| | |
3| 1| 2| | |
4| NC| none| | |
5| NC| none| | |
6| 2| 2| | |
7| NC| none| | |
8| NC| none| | |
S| S| | | |
- S = shield
- NC = not connected
Creating/Changing Wiring Definitions
Here, too, you can create your own versions, although you can only do so by
changing an existing definition.. It is useful to note the pin/pair assignment
of the wiring version being created in advance.
After selecting a wiring definition to be changed, you will be taken to the
Name menu. A unique wiring name, such as “568C,” can be entered here. There
are 15 available character slots. At the flashing cursor position, the ▲ and ▼
keys can now be used to scroll through the alphabet, all digits 0–9 and an
empty position. The desired digit or letter at the cursor position can be
selected with SEL.
Once the name has been entered, confirm with SEL. The Connections menu will
open, where the PIN is assigned to the PIN and wire pair as corresponds to the
wiring version. This assignment is necessary both for recognition of the
correct assignment in the tested cable and of split pairs with regard to
crosstalk and for good/bad information after a successful test. The scroll bar
is set to Pin 1.
Select with SEL, which will bring you to the Connection menu for Pin 1. Now
the possible selections of all 8 pins that can be assigned to Pin 1 will
appear. Use the ▲ and ▼ keys to select the correct pin with SEL. The next step
is the Pair menu, where you can assign the selected pins to a pair with SEL.
You will now be back in the Connections menu, where you can see the assignment
of the Pin
1. Use the ▼ key to move the scroll bar to the next item, and continue with
the assignment as before.
If you create any incorrect assignments, you can only overwrite them.
Alternatively, you can select the Device Settings > Reset to Factory Settings
menu item. This will reset all changed wiring definitions.
Remote Unit ID
The KE7010 remote units required for correct and quick cabling verification are included with No. 32 to simplify inventory management. Under Main Menu > Settings > Test Settings > Remote Unit, a connected remote unit can simply be reprogrammed to the desired number. After changing the number, we recommend writing the new number in the space provided on the back of the device.
MAC Address
The KE7200 is shipped with a predefined MAC address. In order to work in
networks with MAC address verification, the address can be freely defined
here.
Settings > IP Address
The IP address of the KE7200 is set here. This address is always used as
device address, including for an IP test, such as as static network address.
It can be changed at any time. Simply use the ▲ and ▼ / ◄ and ► keys to set
the address and save it with SEL. However, the change can also be made
directly in the same way, such as during an IP test.
Application
You can perform various tests with the devices.
- Cable test page 17
- Cable/wire search via the port finder function (link blink function) or search tone (tone mode) page 19
- PoE/PoE++ test (according to IEEE802.3af/at/bt) page 19
- IP-Test (including network speed) and ping test page 20
- Detection of branches / stub lines (bridge taps) page 21
The KE7200 checks the connected line for external voltage before each start of the test options.
If present, the test will not be started, and the voltage level will be displayed.
External voltage present:
-
The actual external voltage may be much higher than displayed!
The level of the external voltage is only displayed with an exact value up to 74.7 V. All external voltages > 74.7 V are displayed as 74.7 V. -
Stop the test immediately if external voltage is present and disconnect all test leads!
A safety-critical condition may exist, and/or the unit may be damaged.
Fix the faulty network condition before continuing the test.
The test can only be performed after the external voltage has been switched off. External voltage has nothing to do with PoE for this detection. For PoE systems that are working correctly, the supply of voltage must always be activated.
Cable Test
The cable test can be performed with or without the KE7010 remote unit. If it
is done without the KE7010, only field length measurement and checking for
crosstalk due to split pairs will be performed.
When the KE7010 is connected at the end, the length measurement using the TDR
method is sufficiently accurate to determine whether the field is in the 90 m
range. This test measures up to a maximum of 200 m. For measuring installed
cables, we recommend performing the length measurement separately without the
KE7010. This measurement is more accurate with regard to the length, since a
clear end can be detected without the KE7010.
The cable lengths can only be determined correctly using the correct VF
factor! See page 13 f.
Test Execution
Up to 32 KE7010 remote units can be connected simultaneously to the ports to
be measured using the included patch cables. If only one KE7010 is used, it
must be taken to the next port after the test has been completed. If an
assistant is involved, he can detect whether the test resulted in any errors
by the flashing rhythm of the LED after the test has been completed. If no
error has been detected (slow flashing every 1 second),he can proceed to the
next port.
However, we recommend the use of several KE7010 units, one for each room. With
the 32 possible KE7010 units, a patch field area with, say, up to 32 ports can
be easily covered, even with somewhat larger systems. The main advantage is
clearly time savings, as only one person is needed. At the same time, there is
a clear assignment of the measurements with the KE7010 in the documentation.
Connect the KE7200 with the 0.5 m patch cable (included) to the port to be
tested on the patch panel.
Start the test with the scroll bar for Cable Test by pressing the SEL button.
The progress information is displayed with the Cable Test Running, and the
progress is displayed in %. If the test was free of errors, a long beep will
sound, and the OK checkmark will be displayed. The LED on the remote will
flash steadily every 1 second.
If any errors are detected, two short beeps will sound, and the LED on the
KE7010 will flash: 4× briefly (0.5 seconds), then a pause of 1 second, then
again 4× briefly and so on.
The KE7200 always shows the number of the KE7010 remote unit in the upper left
corner of the display, followed by the type of wiring. This can be changed by
pressing the ▼ key, after which the set VF value is displayed. This is set
either by selecting a cable type or by setting it directly beforehand.
The main window displays the Wire Mapping. Here, any existing wiring errors
can be readily identified. A split pair is displayed with a branching to the
connected wire and back again, with the measured field length appearing in the
right field. Lengths below 2 m are not displayed. The measurement is too
inaccurate in this close range. The maximum length measurement is approx.
200 m, but this will also depend on the cable itself.
The lower display line is the dialog line. Possible operating steps for the
respective test are displayed here.
Use the ◄ and ► keys to display the calculated details for each wire. For
example, an interruption or a short circuit can be clearly assigned to the
near or far end. If the error is somewhere in between, the value can be read
in meters.
The ◄ key shows the wire lengths, the ► key the number of errors, the type of
error, the affected pin, where it should be if incorrectly connected and where
it is now, and the length of the error.
By its nature, only the linked pair can be defined for split pairs. In some
cases, individual interconnections between other wires are also detected. This
is due to the fact that crosstalk also affects other neighboring wire pairs
due to the split pair.
As a rule, it is also necessary to ensure that the configured wiring version
(e.g., 568A) corresponds to the actual wiring.
Storing Data
After the measurement has been completed, it can either be exited with ESC, or
the Save Data menu can be opened by pressing the SEL key. The predefined name
of the measurement – Default – followed by a number is displayed here. If the
data is to be assignable later, you will need to enter a unique name here. We
recommend customer names or a number. The entry is made by pressing the ▲ or ▼
keys, which allows scrolling through the alphabet and the numbers from 0-9.
Press SEL to insert the desired character. The cursor position can be changed
with the ◄ and ► keys.
This name will remain entered until it is overwritten again. This means that,
when saving the next measurement, if the customer is still then same, nothing
will have to be changed. The number of the measurement will increase
automatically. You can then sort, print, and save the data in the KE7200
Manager PC software (see page 22) according to the customer number or the
name. It should be noted that it is necessary to adjust the memory setting at
the start of a new measurement series at another system.
The second line displays the available memory space. A total of about 14,000
entries are possible.
Cable/Wire Search via the Port Finder Function (link blink function) or Search
Tone (tone mode) (Ethernet cable only)
The KE7200 has two ways of identifying a known socket at the patch panel,
switch, or hub:
Portfinder Function (link blink function)
Plug the test cable of the KE7200 into the socket located in the room and
select the Link Blink test in the Cable/Wire Search menu.
It is verified whether the socket is active in the network. This is displayed
in the status line of the KE7200. When the connection is active, information
about the Ethernet connection with the respective detected speed is displayed.
The associated port on the patch panel/router/hub/switch will flash.1
If the port is not active, No Connection will be displayed. Then you will need
to proceed with tone mode.
Search Tone (tone mode)
Then you can switch to the tone mode in which one of 4 tones (1000 Hz;
880/1000 Hz; 2600 Hz, and 2600/1900 Hz) is transmitted to all wire pairs by
the KE7200. The P310 probe can then be used to search for the search tone at
the patch panel/router/hub/switch and to unequivocally identify the associated
network port.
PoE/PoE++ Test (according to IEEE802.3af/at/bt)
(Ethernet cable only)
Connect the KE7200 to the network. Start the test with the SEL key. The KE7200
activates the PoE port and outputs the corresponding information in the
display regarding whether PoE/PoE+/PoE++ is present or not.
The PoE standards are displayed according to the expected nominal voltages.
Higher voltages (fault conditions) can damage the instrument and pose a
potential safety hazard.
If PoE can be activated, this will happen. To begin with, the max. load is applied to remove the cable charge. The maximum available power is then measured according to the IEEE802.3af/at/bt standard. This regulates which voltage must be present on the line when a certain current is flowing.
If this voltage is below the standard value, the KE7200 will switch the load
back until the voltage is within the normal range again.
This power is calculated and then displayed. This information is important in
any network with PoE subscribers, as disturbances will occur again and again
due to the load on the power supply in the switch being at the limit. If a
small additional load is now added, such as due to changed operating
conditions like the switching on of infrared illumination, the network will
collapse and the switch will only supply the emergency power. This cannot be
detected without appropriate test equipment. Some PoE switches also provide 30
W per port. These then work outside the specification.
The test will need to be restarted for each measurement.
IP Test, Including Network Speed and Ping Test (Ethernet cable only)
During the network test, the KE7200 can search the network for IP addresses
and thus subscribers. This can be done in DHCP mode or with a fixed IP
address. If the network also monitors MAC addresses, the MAC address of the
KE7200 can be adapted (see page 12).
The DHCP mode is first activated by selecting IP Test >
DHCP Request. As soon as a network connection is established,it is displayed
in the status line, and the IP address assigned to the KE7200 by DHCP is
displayed. The request for occupied IP addresses in the assigned address space
starts immediately. The number found is also displayed.
The KE7200 now queries all addresses for information and lists it. If names
are available, they are displayed – if not, only the IP address.
This process can take some time, especially if there are many subscribers in
the network. You can see the progress by the change in the IP addresses found.
At the top of the screen, Network is displayed. Selection with SEL shows
general network information such as Connection
Speed, own IP Address, and Network Mask. The ▼ key scrolls to the next page.
This will display the following:
- Domain name of the network
- IP of the DNS server
- IP of the DHCP server
- IP of the router
Press the SEL key to save this data.
It may happen that not all computers in a network will always respond within
the query time of the test device, as they may be occupied with other tasks.
This is due to the system-specific nature and does not represent an error. The
query can be repeated as often as desired.
The subscriber list is opened with ESC. By selecting a subscriber, the IP and
MAC address are displayed in addition to the Name, the IP Address, and the MAC
Address. This address can then be pinged in this menu.
Selecting with SEL opens the Ping menu. The frame size is displayed in the
upper left corner.
The ▲ and ▼ keys can be used to set the frame size between 32 and 1024 bytes.
Start of the ping test with SEL.
The KE7200 now continuously sends pings to the selected address. This is done
at maximum speed in order to perform a stress test for all components at the
same time.
It may happen that the network component is overloaded by the ping stress test
and stops responding.
The success of the test is indicated by the number of pings sent and the
number of pings lost. In addition, you can also see the response times
(maximum, minimum, and average).
Detection of Branches / Stub Lines (bridge taps)
– Requires Branch Detection Software Option (coaxial cable and
telecommunications cable only)
The branch detection software option (D720S) is a function extension that
enables the detection of branches / stub lines. Not only can it be used to
detect any branches / stub lines that may be present, but it can also locate
them precisely up to a cable length of 150 meters. The branches/ stub lines,
which are difficult to detect, cause signal reflections (echoes) that have a
negative effect on the signal and lead to DSL network problems.
You can order the software option with your order or purchase it later from
our service department (for contact information, see page 26).
Start the test with the scroll bar on Branch by pressing the SEL key. The
progress information is displayed with Branch Detection Running and Progress
in %. If the test was free of errors, a long beep will sound, and the OK
checkmark will be displayed. The LED in the remote flashes evenly every 1
second.
If an error is detected, two short beeps will sound, and the LED on the remote
unit will flash: 4× briefly (0.5 seconds), then a pause of 1 second, then
again 4× briefly and so on.
The result is displayed on the main screen. Here the branch line is readily
visible with the exact distance. Lengths below 2 m are not displayed. The
measurement is too inaccurate in this close range.
Data Transmission and Management of Measurements and Log Generation with KE7200 Manager PC Software The KE7200 Manager PC software is a flexible tool for configuring the KE7200 and for downloading test/measurement data from the measuring instrument.
It provides the following functions:
- Configuration of the manager (columns, language)
- Display of the KE7200 hardware version
- Display of the current KE7200 software/firmware version
- KE7200 firmware update
- Display of the KE7200 operating instructions
- Transfer of tests/measurements from the KE7200 to a PC
- Adding/deleting of loaded test/measurement data
- Storing of tests/measurements
- Retrieval of stored tests/measurements
- Log generation (printing)
Installing KE7200 Manager
KE7200 Manager is only available as a Windows versions for systems as of
Windows 10 and newer.
You can download the KE7200 Manager for free from our website:
https://www.kurthelectronic.de/ke7200-downloads/?lang=en
Run the .exe file on the PC to install the program. This creates a screen
shortcut on the desktop for launching KE7200 Manager.
Starting KE7200 Manager and Transferring Measurements
Connect the KE7200 to the PC with an Ethernet cable.
Then launch KE7200 Manager on the PC. Once the program has been called up,
KE7200 Manager will display its version number. Enter the IP address of the
KE7200 under Config.Table /IP (can be viewed or configured in the instrument;
see”Settings > IP Address” on page 17).
Close the program.
Now open Windows Control Panel and call up Network and Sharing Center > Change
Adapter
Settings. Select the appropriate Ethernet adapter from all those displayed and
open its Properties.
Select Internet Protocol, Version 4 (TCP/IPv4) from the list and open
Properties. Select
Use Following IP Address and enter the IP address of the KE7200 for IP Address
and click in the Subnet Mask field so that it is filled in automatically.
Confirm with OK.
Then restart KE7200 Manager on the PC. Select Transfer Measurements in the
KE7200. The stored data are transferred immediately after synchronization and
appear in KE7200 Manager.
The KE7200 can now be disconnected again.
If no stored measurement data are available, this will be displayed. The data
on the KE7200 can now be deleted or aborted with ESC.
Program Operation
You can switch between the cable tests and network tests via the tab (see marking in the screenshot).
The selection tabs on the top are the same for both displays.
-
Load Data (PC)
Tests/measurements that have already been saved can be opened for display here (.eth file). -
Save All Data
Here the data transferred by the KE7200 are selected for saving on the PC (.eth file). -
Save Displayed Data
Once the data has been selected, it is saved as a separate list (.eth file). -
Delete Marked Line
This deletes a complete line of test/measurement results. -
Print Data
A print version (log) of the measurements is created. You can store your company logo here to display it in the log. A graphics file (.bmp, .dip, .jpg, .gif, .wmf, .emf,.ico, .cer) is displayed at the top right edge of the sheet. We recommend a maximum size of 400 px in width × 250 px (width × height) at a resolution of 300 dpi.
You can also make further settings to customize the appearance of the test report. -
Configuration Table / IP
The IP address of the KE7200 for data transmission is entered in the upper area here. See “Starting
KE7200 Manager and Transferring Measurements” on page 22
The presentation of the displayed data (table columns) can be changed in the lower area. -
KE7200 Update
This menu item is used for installing software/firmware updates; see page 24. -
Instructions
Calls up the instructions for the KE7200. -
Show Following Measurements
After all data records have been downloaded from the KE7200, it is possible that they involve data or measurements from different customers. However, this assignment must already be done in the KE7200 when saving on location. You can sort the data by customer or make a selection.
A list with all saved data sets will open. You can then select the customer you want to summarize,comment on, and print out as a report.
This selection can then be saved with Save Shown Data by entering their data (customer name,number, etc.). -
Customer Address, Comment, Technicians
In the lower area, you have the option of entering the customer address, the technician, and any comments. The address entered in the first data set is shown as the first item on the report. The technician, location name, and comments can be entered separately for the individual data sets.
Storage and Transport
Caution: Improper storage will cause damage to the product.
Store the instrument packed and protected from environmental influences.
Caution: Improper transport will cause damage to the product.
Transport the instrument packed and protected from environmental influences.
Only transport the instrument in the supplied bag. Alternatively, we recommend
the accessories available for the device (transport case); details can be
found on the data sheet.
Maintenance
Cleaning: Make sure that the surfaces of the instrument and accessories are clean.
Caution: Risk of injury
The instrument and accessories must be de-energized before starting and during
cleaning.
Switch the instrument off and disconnect it from all cables/lines/adapters.
Never immerse the instrument/accessories in water or other liquids.
Caution: Equipment damage
Never touch the instrument/accessories with wet hands.
Unsuitable cleaning agents, such as aggressive or abrasive agents, will cause
damage to the instrument/accessories.
Use a cloth that has been slightly dampened with water for cleaning. Avoid the
use of cleansers, abrasives, or solvents.
Contact, Support, and Service
Gossen Metrawatt GmbH can be reached directly and simply – we have a single
number for everything! Whether you require support or training or have an
individual inquiry, we can answer all of your questions here:
+49 911 8602-0 Monday to Thursday: 8 a.m. to 4 p.m.
Friday: 8 a.m. to 2 p.m.
Also available by e-mail:
info@gossenmetrawatt.com
Do you prefer support by e-mail?
Measuring and Test Technology:
support@gossenmetrawatt.com
Industrial Measuring Technology:
support.industrie@gossenmetrawatt.com
Please contact GMC-I Service GmbH for repairs, replacement parts, and
calibration:
+49 911 817718-0 Beuthener Straße 41
90471 Nürnberg
Germany
service@gossenmetrawatt.com
www.gmci-service.com
Statement of Conformity
Relevant Standards and Guidelines
The equipment has been manufactured in accordance with the following guidelines:
- EMV Directive 2014/30/EU
- CISPR 11 + A1
- CISPR 16-1-2 Edition 1.2
- CISPR 16-2-1 + A1
- CISPR 16-2-3 + A1
- IEC 61000-4-1
- IEC 61000-4-2 Edition 2
- IEC 61000-4-3 + A1 + A2
- IEC 61000-4-8
- IEC 61326-1
- IEC 61326-2-1
- CE Declaration
The instrument fulfills all requirements of applicable EU directives and national regulations. We confirm this with the CE mark. You can find the CE declaration on our website: https://www.gmc-instruments.de/services/download- center/
Disposal and Environmental Protection
Proper disposal makes an important contribution to the protection of our
environment and the conservation of natural resources.
Caution: Environmental Damage
Improper disposal results in environmental damage. Follow the instructions
concerning return and disposal included in this section.
The following comments refer specifically to the legal situation in the
Federal Republic of Germany. Owners or end users who are subject to other
national requirements are required to comply with the respectively applicable
national requirements and to implement them correctly on site. Relevant
information can be obtained from the responsible national authorities or
national distributors, for example.
Waste Electrical Equipment, Electrical or Electronic Accessories,and Waste
Batteries (including rechargeable batteries)
Electrical equipment and batteries (including rechargeable batteries) contain
valuable raw materials that can be recycled, along with hazardous substances
that can cause serious harm to human health and the environment, and they must
be recycled and disposed of correctly.
The symbol on the left depicting a crossed-out garbage can on wheels refers to
the legal obligation of the owner or end user (German electrical and
electronic equipment act ElektroG and German battery act BattG) not to dispose
of used electrical equipment and batteries with unsorted municipal waste
(“household trash”). Waste batteries must be removed from the old device
(where possible) without destroying them, and the old device and the waste
batteries must be disposed of separately. The battery type and its chemical
composition are indicated on the battery’s labelling. If the abbreviations
“Pb” for lead, “Cd” for cadmium or “Hg” for mercury are included, the battery
exceeds the limit for the respective metal.
Please observe the owner’s or end user’s responsibility when it comes to
deleting personal data– any other sensitive data – from old devices before
disposal.
Old devices, electrical or electronic accessories and waste batteries (including rechargeable batteries) used in Germany can be returned free of charge to Gossen Metrawatt GmbH or the service provider responsible for their disposal in compliance with applicable regulations, in particular laws concerning packaging and hazardous goods. More information regarding returns can be found on our website.
Handling Packaging Materials
We recommend retaining the respective packaging materials in case you require
servicing or calibration in the future.
Warning: Danger of asphyxiation from foils and other packaging materials
Children and other vulnerable persons may suffocate if they wrap themselves in
packaging materials or their components or foils or if they pull them over
their heads or swallow them.
Keep packaging materials and their components and foils out of the reach of
babies, children, and other vulnerable persons.
In accordance with the German Packaging Act (VerpackG), the user is obligated
to correctly dispose of packaging and its components separately and not
together with unsorted municipal waste (“household trash”).
Private end consumers can dispose of packaging free of charge at the
responsible collection point. Packaging that is not subject to system
participation is returned to the appointed service provider. More information
regarding returns can be found on our website.
© Gossen Metrawatt GmbH
Prepared in Germany • Subject to change, errors excepted
All trademarks, registered trademarks, logos, product names, and company names
are the property of their respective owners.
References
- Servicepartner für Kalibrierungen, Reparaturen, Ersatzteile, Mietgeräte | GOSSEN METRAWATT GMC-I Service GmbH
- GOSSEN METRAWATT, GMC-Instruments
- Download Center | GOSSEN METRAWATT | CAMILLE BAUER
- Download Center | GOSSEN METRAWATT | CAMILLE BAUER
- KE7200 Downloads – Kurth Electronic
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>