Breezary 24020-BK 19 Inch Black LED Indoor Downrod Ceiling Fan Installation Guide

June 16, 2024
Breezary

Breezary 24020-BK 19 Inch Black LED Indoor Downrod Ceiling Fan

Breezary-24020-BK-19-Inch-Black-LED-Indoor-Downrod-Ceiling-Fan-
PRODUCT

Product Information

Specifications

Safety Information

  • To reduce the risk of electric shock, ensure electricity has been turned off at the circuit breaker or fuse box before you begin.
  • All wiring must be in accordance with the National Electrical Code ANSI/NFPA 70 and local electrical codes. Electrical installation should be performed by a qualified licensed electrician.
  • The outlet box and support structure must be securely mounted and capable of reliably supporting a minimum of 35 lbs (15.9 kg).Use only UL Listed outlet boxes marked “Acceptable for Fan Supportof 35 lbs. (15.9 kg) or less”.
  • Do not place objects in the path of the blades.
  • To clean the fixture, turn off the power, wait for it to cool,and wipe the fixture with a clean, soft cloth.
  • After making electrical connections, spliced conductors shouldbe turned upward and pushed carefully up into the outlet box. Thewires should be spread apart with the grounded conductor and theequipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box.
  • All setscrews must be checked and retightened where necessarybefore installation.
  • WARNING: To reduce the risk of electrical shock or fire, do not use this fan with any solid-state fan speedcontrol device. It will permanently damage the electroniccircuitry.
  • WARNING: To reduce the risk of personal injury, do not bend the blade brackets when installing the bracketsbalancing the blades, or cleaning the fan. Do not insert.
  • WARNING: To reduce the risk of fire, electric shock, or personal injury, mount to outlet box marked acceptablefor fan support of 35 lbs. (15.9 Kg) or less and use screwsprovided with the outlet box.
  • WARNING: To avoid possible electrical shock, turn the electricity off at the main fuse box before wiring.
  • WARNING: To reduce the risk of electrical shock, this must be installed with an isolating wall control /switch.
  • CAUTION: To reduce the risk of personal injury, use only the screws provided with the outlet box.
  • CAUTION: The fan must be mounted with aminimum of 7 ft (2.1 m) clearance from the trailing edge of theblades to the floor.
  • CAUTION: Changes or modifications notexpressly approved by the party responsible for compliance couldvoid the user’s authority to operate the equipment.

Dimension Reference

  • Expansion Screw: 2
  • Canopy Yoke: 2
  • Batteries: 2
  • Yoke: 2

Hardware Included

  • Fan Parts Included: 3

Exploded View
(No image provided in the user manual)

Installation Instructions

  1. Take out the lower post, top cover, yoke cover.
  2. Secure downrod in position by tightening jam screws.
  3. Slide yoke cover down and it will flush with the motorhousing.

Troubleshooting Guide
(No troubleshooting information provided in the user manual)

FAQ

Q: Can I use this fan with a solid-state fan speed control device?
A: No, using this fan with a solid-state fan speed control device will permanently damage the electronic circuitry.

Q: Can I bend the blade brackets when installing or cleaning the fan?
A : No, bending the blade brackets can lead to personal injury and should be avoided during installation or cleaning.

Q: Can I use any outlet box to mount the fan?
A: No, you must use an outlet box that is marked acceptable for fan support of 35 lbs. (15.9 Kg) or less and use the screws provided with the outlet box to reduce the risk of fire, electric shock, or personal injury.

Q: Can I wire the fan without turning off the electricity?
A: No, to avoid possible electrical shock, always turn off the electricity at the main fuse box before wiring the fan.

Q: Can I install the fan without an isolating wall control/switch?
A: No, to reduce the risk of electrical shock, the fan must be installed with an isolating wall control/switch.

Customer Service: support@breezary.com

Safety Information

READ AND SAVE THESE INSTRUCTIONS.

  1. To reduce the risk of electric shock, ensure electricity has been turned off at the circuit breaker or fuse box before you begin.

  2. All wiring must be in accordancce with the National Electrical Code “ANSI/NFPA 70” and local electrical codes. Electrical installation should be performed by a qualified licensed electrician.

  3. The outlet box and support structure must be securely mounted and capable of reliably supporting a minimum of 35 lbs (15.9 kg). Use only UL Listed outlet boxes marked “ Acceptable for Fan Support of 35 lbs.
    (15.9 kg) or less. ”

  4. Do not place objects in the path of the blades.

  5. To clean the fixture,turn off the power, wait for it to cool, and wipe the fixture with a clean, soft cloth.

  6. After making electrical connections, spliced conductors should be turned upward and pushed carefully up into the outlet box. The wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box.

  7. All setscrews must be checked and retightened where necessary before installation.

WARNING:

  • To reduce the risk of electrical shock or fire, not use this fan with any solid-state fan speed control device. It will permanently damage the electronic circuitry.
  • To reduce the risk of personal injury, do not bend the blade brackets when installing the rackets balancing the blades, or cleaning the fan. Do not insert
  • To reduce the risk of fire, electric shock or personal injury, mount to outlet box marked “acceptable for fan support of 35 lbs. (15.9 Kg) or less” and use screws provided with the outlet box.
  • To avoid possible electrical shock, turn the electricity off at the main fuse box before wiring.
  • To reduce the risk of electrical shock, this must be installed with an isolating wall control / switch.

CAUTION:

  • To reduce the risk of personal injury, use only the screws provided with the outlet box.
  • Please use carefully when working around or cleaning the fan to avoid injury or damage of fan.
  • The fan must be mounted with a minimum of 7 ft (2.1 m) clearance from the trailing edge of the blades to the floor.
  • Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Dimension Reference

Breezary-24020-BK-19-Inch-Black-LED-Indoor-Downrod-Ceiling-Fan-FIG-
\(1\)

Hardware Included

Fan Parts Included

Exploded View

Breezary-24020-BK-19-Inch-Black-LED-Indoor-Downrod-Ceiling-Fan-FIG-
\(5\)

Installation Instructions

Step1 MOUNTING

  • Take out fan motor housing.
  • Remove cotter pin and bolt from yoke. (Fig.1a)
  • Loosen jam screw in yoke until it is flush with the inside surface. (Fig. 1b)
  • Take out the lower post, top cover, yoke cover
  • Place downrod inside canopy and yoke cover. (Fig. 1c)
  • Route wires exiting motor through yoke cover, canopy and downrod.
  • Insert bolt through hole in and downrod. Be careful not to damage or cut the fan wires. (Fig.1d)
  • Tighten bolt. Secure with cotter pin through hole in the end of the bolt.
  • Secure downrod in position by tightening jam screws.Slide yoke cover down and it will flush with the motor housing. (Fig.1e)

CAUTION: To ensure wobble-free operation and to avoid damage to the fan, the downrod and the set crew must be completely tightened.

Breezary-24020-BK-19-Inch-Black-LED-Indoor-Downrod-Ceiling-Fan-FIG-
\(6\)

The main assembly of the ceiling fan is completed, place it on the cardboard box.

Step4 INSTALL MOUNTING BRACKET
If it is installed on the cement top and don’t have outlet box, please use two expansion screw.

  • Use an impact drill to drill two 8mm holes, Note that the distance between the two holes is about 100mm.
  • Completely insert the pipe part of the screw into the hole and remove the washer and nut.
  • Place the hanger into the screw head, place the washer, and then use a wrench to tighten the nut.

Breezary-24020-BK-19-Inch-Black-LED-Indoor-Downrod-Ceiling-Fan-FIG-
\(8\)

WARNING: To Reduce The Risk Of Fire, Electric Shock, Or Personal Injury, Mount To UL/CSA Listed Outlet Box Marked Acceptable for Fan Support And Use Mounting Screws Provided With The Outlet Box

  • Install J-Hook through centre of outlet box and into the wooden joist.
  • Secure mounting bracket and rubber gaskets to metal outlet box.

Breezary-24020-BK-19-Inch-Black-LED-Indoor-Downrod-Ceiling-Fan-FIG-
\(9\)

Step5 ELECTRICAL HOOK-UP
A. Make the following wire connections to the receiver unit (see fig. 6) using the wire nuts supplied

  • Connect GREEN fan wire to BARE (ground) wire.
  • Connect BLACK receiver unit wire to BLACK supply wire.
  • Connect WHITE receiver unit wire to WHITE supply wire.
  • After making the wire connections, ensure the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and the ungrounded conductor on the other side of the outlet box.
  • Ensure the splices after being made should be turned upward and pushed carefully up into the outlet box.

NOTE: Once ground wires are connected, carefully tuck all wires and marrettes into the metal box making sure that the wires are clear of the hemisphere and downrod when positioned in hemisphere and downrod when positioned in mounting bracket.

Push all connected wires up into ceiling box.

  • Put the receiver into the mounting bracket as shown in figure 7.
  • When installing the canopy, ensure the antenna is not pressed by the canopy.
  • Ensure to connect all ground wires accordingly.

FUNCTION INSTRUCTION OF EMITTER

Learning code and matching mode is used between emitter and receiver.

  • Open battery cover on the hand-held remote and install battery, pair of AAA of emitter (1.5V) that are not included.

  • If the emitter can not control the fan, learning code matching mode is used between emitter and receiver.
    Turn “ON” the supply power within 10 seconds and press the emitter’s ” (Go)” button for 5 seconds, it can load normally after hearing a long sound “bee”, which means learning successfully and it can works normally.

  • When the emitter cannot control the receiver, please check the battery switch touching normally or not, correction of the positive and negative, full or empty of the power.

  • When the emitter cannot control the receiver, please check is there any existence of similar remote controlled products nearby, then check whether they works, because remote controlled product with the same frequency will disturb each other.

  • Please take out the battery from the emitter when leaving unused for long time.

  • When installing the fan, the fan ceiling cover don’t press the antenna(or other wire), it is easy to breakdown the wire and short-circuited.

  1. Light Switch
  2. Speed Controller
  3. Fan Shutdown
  4. Timer
  5. Indicator Light

Step6 MOUNTING FAN ASSEMBLY

  • Place two screws and washers on mounting plate which correspond with slots in canopy.
    Screw in two turns.

Step7 ENGAGE HEMISPHERE

  • Carefully rotate fan assembly until groove in hemisphere locks over tab of canopy assembly.
  • Loosen (do not remove) the two screws on mounting bracket. Slide the canopy up to mounting bracket and place the key hole on the canopy over the screw on the mounting bracket, turn canopy until it locks in place at the narrow section of the key holes.
  • Align the holes on the canopy with mounting bracket and secure with the two set of screws until snug.

WARNING: Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard.

Breezary-24020-BK-19-Inch-Black-LED-Indoor-Downrod-Ceiling-Fan-FIG-
\(13\)

NOTE: When installing fan on sloped ceiling, make sure tab on hanger bracket faces towards the top of the slope. Depending on the slope, a longer downrod may be required to prevent fan blades from hitting the ceiling.

WARNING: Check all connections, set screws and screws are securely tightened before the next step .

By using forward and reverse switches, the fan rotates forward in summer and reverse in winter.

Breezary-24020-BK-19-Inch-Black-LED-Indoor-Downrod-Ceiling-Fan-FIG-
\(14\)

Troubleshooting Guide

If you have difficulty operating your new ceiling fan it may be the result of incorrect assembly, installation,or wiring.In some cases these installation errors may be mistaken for defects. If you experience any faults please check this troubleshooting guide.

| Problem| Suggested Remedy
---|---|---

1

|

If fan does not start.

| □  Check the main and branch circuit fuses or breakers.

□  Check the line wire connections to the fan and switch wire connections in the switch housing.

□  Check the battery in the remote control.

□  Ensure you are in the normal range of 10-20 feet.

2

|

If fan sounds noisy.

| □  Ensure all motor housing screws are snug.

□  Ensure the screws that attach the fan blade bracket to the motor hub are tight.

□  Ensure the wire nut connections are not rattling against each other or the interior wall of the switch housing.

□  Allow a 24-hour “breaking in” period. Most noises associated with a new fan disappear during this time.

□  If you are using the Ceiling Fan light kit, ensure the screws securing the glassware are tight. Check that the light bulbs are also secure.

□  Ensure the canopy is a short distance from the ceiling. It should not touch the ceiling.

□  Ensure your outlet box is secure and rubber isolator pads were used between the mounting plate and outlet box.

3

|

If fan wobbles.

| □  Check that all blades are screwed firmly into blade holders.

□  Check that all blade holders are tightened securely to motor.

□  Make sure that canopy and mounting bracket are tightened securely to ceiling junction box and junction box is mounted firmly to ceiling joist.

□  Most fan wobble problems are caused when blade levels are unequal.Check this level by selecting a point on the ceiling above the tip of one of the blades keeping measure within 1/8 in.Rotate the fan until the next blade is positioned for

measurement.Repeat for each blade.If all blade levels are not equal you can adjust blade levels by the following procedure.To adjust a blade tip down insert a washer(not supplied)between the blade and blade holder at the screw closest to the motor.To adjust a blade tip up insert washer(not supplied)between the blade and blade holder at the two screws farthest from the motor.

□  If blade wobble is still noticeable interchanging two adjacent (side by side)blades

can redistribute the weight and possibly result in smoother operation.

4

|

If light does not work.

| □  Check blue wire from fan to make sure it is connected to hot wire from the house.

□  Check for loose or disconnected wires in fan switch housing.

□  Check for loose or disconnected wires in light kit.

□  Check for faulty light bulbs.CAUTION:Make sure main power is turned off before entering switch housing.

□  If the fan light shuts off shortly after being switched on it may be due to excessive current demand.Turn off power to the fan and replace the light bulbs with lower

wattage bulbs.Turn on power to the fan using the pull chain,wall switch,or remote control (whichever is installed on the particular fan).

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals