IQ Pro 22IQPRO Pro Smartwatch User Guide
- June 16, 2024
- IQ Pro
Table of Contents
- Alarms
- User code functions
- Trouble conditions
- Managing Partitions
- Additional features
- Reference sheets
- Safety Instructions
- Locating Detectors and Escape Plan
- End-user License Agreement
- FCC Compliance Statement
- Copyright and Trademark
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
22IQPRO Pro Smartwatch
User Guide
Alarms
The system generates different alarm sounds, each with a different purpose and
priority.
Table 12: Alarm sounds
Priority | Type of Alarm | Sound |
---|---|---|
1 | Fire | Temporal 3 (3 short beeps followed by a 1.5 second pause, repeat) |
2 | Carbon Monoxide | Temporal 4 (4 short beeps, followed by a 5 second pause, |
repeat)
3| Intrusion (Burglary)| Continuous siren
4| Flood| 1 second on, 3 seconds off, repeating
Accidental fire alarms
If the fire alarm sounds accidentally, complete the following steps:
- Enter your access code to silence the alarm.
- Call your central station to avoid a dispatch.
Note: Verify with your alarm company that your system is equipped with fire detection.
Silence fire alarm bells
You can silence a fire alarm by entering a valid access code. The message
is displayed on an LCD or touch screen keypad. The message does not clear
until all the fire zones are restored on system.
Fire Alarm
If a fire alarm occurs, follow your emergency evacuation plan immediately!
If the Fire Alarm was accidental (e.g., burnt toast, bathroom steam, etc.)
- Enter your Access Code to silence the alarm.
- Call your central station to avoid a dispatch.
Note : Verify with your alarm company that your system is equipped with fire detection.
For information on resetting smoke detectors see: “Resetting Smoke Detectors”.
Carbon monoxide detector
WARNING : When the CO alarm sounds immediately move outdoors or to an
open door or window. If the CO alarm activates it indicates the presence of
carbon monoxide (CO), which can be fatal.
Review your carbon monoxide alarm installation or user manual to determine the
necessary actions required to ensure your safety and ensure that the equipment
is operating correctly.
Incorporate the steps outlined in the guide into your evacuation plan.
Intrusion alarm
WARNING : If you are unsure of the source of the alarm approach with
caution.
The intrusion and burglary alarm is a continuous siren. If the Intrusion alarm was accidental, complete the following steps:
- Enter your Access Code to silence the alarm. If the code is entered within 30s (or the programmed value of the dialler delay) the transmission of the alarm to the monitoring station will be cancelled.
- Call your central station to avoid a dispatch.
Viewing alarms in memory
When an alarm occurs the keypad indicator illuminates. View the alarm memory
provides more information on the sensor(s) that were activated.
To view alarms in memory, press [][3] or use the scroll keys to navigate to
alarm memory and press [].
Resetting smoke detectors
After an alarm condition, reset smoke detectors to exit the alarm condition.
Note: Verify with your alarm company if this function is required on your
system.
To reset the sensors, complete the following steps:
-
When there is a fire alarm condition on the system, enter the user code to silence the alarm.
After that, enter the user code again which sends a sensor reset command to the smoke detectors and clears the Bells Silenced message on the keypad. -
If a smoke detector does not reset, it may still be detecting an alarm condition. If unsuccessful, the alarm reactivates or continues. Contact your alarm system provider.
User code functions
The IQ Pro allows for a variety of user configurable functions as listed
below.
Auto-arm time
Edit using the IQ Installer app or the Alarm.com user app.
Editing User Labels
You can edit user labels using the IQ Installer app or Alarm.com user app.
Assigning partitions to users
You can assign partitions to a user using the IQ Installer app or the
Alarm.com user app.
Managing Users
The maximum number of access codes are as follows:
- A maximum of 242 users can be associated with IQ Pro panel.
- Whenever a new partition is created/assigned, a duress code is assigned to it.
Each user access code can be:
- Uniquely labeled.
- Assigned a proximity tag. In order to operate, proximity tags must be enrolled in the system.
- Assigned to only operate specific partitions. For more information on partitions see: “Managing Partitions”.
- Configured with additional attributes. For more information see: “Configuring additional User Options”.
Note : Your installer configures all access codes to be either 4 or 6
digits.
When you create individual users, you can set up custom notifications on the
user app when they access or use your system.
The following are the various user types you can create:
- Master: Access panel functions and system settings
- User: Access panel functions but NOT system settings
- Guest: Give arm and disarm access to users who use the panel on a temporary basis
**Note: You can choose a specific date that disables a user code
automatically.
Adding users
You can add a new users and user codes using the IQ Installer app or Alarm.com
user app.
Opening the Access Code Menu**
To add, change, or delete Access Codes first open the Access Code Menu: User
Management option in the IQ Installer app or from the Alarm.com user
application.
Trouble conditions
Trouble conditions on the IQ Remote
When a trouble occurs on your system, a notification is sent to your message
center. View your message center by touching the envelope icon in the upper
right corner of your touchscreen.
View the section on sensor status for more details.
Trouble conditions on the LCD keypad
When a trouble condition occurs, your alarm system identifies the trouble by
displaying an error message on the LCD keypad. If additional help is required,
contact your alarm service provider for service.
When the system detects a trouble condition the following occurs:
- The Trouble indicator turns on.
- The keypad beeps twice every 10 seconds. Press the [*] key to silence the keypad beeps.
Press [][2] to examine troubles.
To override this condition, enter [][2], scroll to Acknowledge All Troubles
and press [*] or enter 99.
Arming of your system can be impeded by a trouble.
Managing Partitions
A partition is a limited area of the premises which operates independently
from the other areas.
Partitioning a system can be beneficial if the property has outbuildings that
need to be secured independently of a main area or if the home has a separate
apartment. Each partition can have its own keypad, or a keypad can have access
to all partitions. User access to partitions is controlled with an access
code. A master code can access the entire system and partitions, while a user
code is limited to assigned partitions.
Partitions
Note: Access to this feature must be configured by installer.
Single Partition Operation
Single partition keypads provide access to alarm functionality for an assigned
partition. Single partition keypads behave as follows:
- Displays the armed state of the partition.
- Displays open zones, if assigned to the partition the keypad is on.
- Displays bypassed zones and allows zone bypassing or creating bypass groups of zones assigned to the keypad partition.
- Displays system troubles (system low battery, system component faults/tampers).
- Displays alarms in memory that occurred on the partition.
- Allows the door chime to be enabled/disabled.
- Activate system test (sounds bells/PGMs assigned to the partition)
- Allow label programming ( user labels for the partition)
- Control command outputs (those assigned to the partition, or global outputs such as smoke detector reset)
- Display temperature (not evaluated by UL)
Fire and CO Zone Types
- If a fire zone generates an alarm only the partition the fire zone is assigned to will go into alarm. Other partitions retain their current state.
- One or more keypads may be located on any partition.
- On alarm, the fire auto-scroll display appears on all partition keypads. Fire alarm silence and fire system reset may be done directly on any partition keypad. To silence a fire or CO alarm from a global keypad requires that the global keypad be loaned to one of the partitions.
Additional features
Turning the chime on or off
Turn the chime to audibly notify you when an entry/exit sensor is activated.
Press and hold the Chime key.
System Lockout due to invalid attempts
If too many invalid access codes are entered, your system automatically lock
out inputs from all keypads, wireless and proximity keys, for a specified
duration. When any keys are pressed, an error tone will sound. FMP keys are
still active during Keypad Lockout.
Command outputs
While being useful for many applications, Command outputs are typically
configured to operate items such as garage doors or electric gates. This is a
supplementary feature that has not been investigated by UL/ULC. Must be
configured by installer. To activate a Command Output:
- Press [][7] and if required enter your [access code] OR press [] and use the scroll keys to navigate to Output Control.
- Press the number configured to the command output OR use the scroll keys to navigate to the desired command output and press [*].
Reference sheets
Fill out the following information for future reference and store this guide
in a safe place.
System information
- [F] FIRE
- [M] MEDICAL
- [P] PANIC
The Exit Delay Time is seconds.
The Entry Delay Time is seconds.
Service contact information
Central Station Information
Account #: Telephone #:
Installer Information
Company: Telephone #:
Battery Installation / Service Date:
- Important: If you suspect a false alarm signal has been sent to the central monitoring station, call the station to avoid an unnecessary response.
Access codes and sensor / zone information
Master Code [01] : _____
Access Code Reference Sheet
User | Access Code | User | Access Code | User | Access Code | User | Access Code |
---|---|---|---|---|---|---|---|
01 | 02 | 03 | 04 | ||||
05 | 06 | 07 | 08 | ||||
09 | 10 | 11 | 12 | ||||
13 | 14 | 15 | 16 | ||||
17 | 18 | 19 | 20 | ||||
21 | 22 | 23 | 24 | ||||
25 | 26 | 27 | 28 | ||||
29 | 30 | 31 | 32 | ||||
33 | 34 | 35 | 36 | ||||
37 | 38 | 39 | 40 | ||||
--- | --- | --- | --- | --- | --- | --- | --- |
41 | 42 | 43 | 44 | ||||
45 | 46 | 47 | 48 | ||||
49 | 50 | 51 | 52 | ||||
53 | 54 | 55 | 56 | ||||
57 | 58 | 59 | 60 | ||||
61 | 62 | 63 | 64 | ||||
65 | 66 | 67 | 68 | ||||
69 | 70 | 71 | 72 | ||||
73 | 74 | 75 | 76 | ||||
77 | 78 | 79 | 80 | ||||
81 | 82 | 83 | 84 | ||||
85 | 86 | 87 | 88 | ||||
89 | 90 | 91 | 92 | ||||
93 | 94 | 95 | 96 | ||||
97 | 98 | 99 | 100 | ||||
100 | 101 | 102 | 103 | ||||
104 | 105 | 106 | 107 | ||||
108 | 109 | 110 | 111 | ||||
112 | 113 | 114 | 115 | ||||
116 | 117 | 118 | 119 | ||||
120 | 121 | 122 | 123 | ||||
124 | 125 | 126 | 127 | ||||
128 | 129 | 130 | 131 | ||||
132 | 133 | 134 | 135 | ||||
136 | 137 | 138 | 139 | ||||
140 | 141 | 142 | 143 | ||||
144 | 145 | 146 | 147 | ||||
148 | 149 | 150 | 151 | ||||
152 | 153 | 154 | 155 | ||||
156 | 157 | 158 | 159 | ||||
160 | 161 | 162 | 163 | ||||
164 | 165 | 166 | 167 | ||||
168 | 169 | 170 | 171 | ||||
--- | --- | --- | --- | --- | --- | --- | --- |
172 | 173 | 174 | 175 | ||||
176 | 177 | 178 | 179 | ||||
180 | 181 | 182 | 183 | ||||
184 | 185 | 186 | 187 | ||||
188 | 189 | 190 | 191 | ||||
192 | 193 | 194 | 195 | ||||
196 | 197 | 198 | 199 | ||||
200 | 201 | 202 | 203 | ||||
204 | 205 | 206 | 207 | ||||
208 | 209 | 210 | 211 | ||||
212 | 213 | 214 | 215 | ||||
216 | 217 | 218 | 219 | ||||
220 | 221 | 222 | 223 | ||||
224 | 225 | 226 | 227 | ||||
228 | 229 | 230 | 231 | ||||
232 | 233 | 234 | 235 | ||||
236 | 237 | 238 | 239 | ||||
240 | 241 | 242 |
Note : Copy this page as needed to record additional access codes.
Sensor/Zone Information
Zone | Protected Area | Sensor Type | Zone | Protected Area | Sensor Type |
---|---|---|---|---|---|
01 | 02 | ||||
03 | 04 | ||||
05 | 06 | ||||
07 | 08 | ||||
09 | 10 | ||||
11 | 12 | ||||
13 | 14 | ||||
15 | 16 | ||||
17 | 18 | ||||
19 | 20 | ||||
21 | 22 | ||||
--- | --- | --- | --- | --- | --- |
23 | 24 | ||||
25 | 26 | ||||
27 | 28 | ||||
29 | 30 | ||||
31 | 32 | ||||
33 | 34 | ||||
35 | 36 | ||||
37 | 38 | ||||
39 | 40 | ||||
41 | 42 | ||||
43 | 44 | ||||
45 | 46 | ||||
47 | 48 | ||||
49 | 50 | ||||
51 | 52 | ||||
53 | 54 | ||||
55 | 56 | ||||
57 | 58 | ||||
59 | 60 | ||||
61 | 62 | ||||
63 | 64 | ||||
65 | 66 | ||||
67 | 68 | ||||
69 | 70 | ||||
71 | 72 | ||||
73 | 74 | ||||
75 | 76 | ||||
77 | 78 | ||||
79 | 80 | ||||
81 | 82 | ||||
83 | 84 | ||||
85 | 86 | ||||
87 | 88 | ||||
--- | --- | --- | --- | --- | --- |
89 | 90 | ||||
91 | 92 | ||||
93 | 94 | ||||
95 | 96 | ||||
97 | 98 | ||||
99 | 100 | ||||
101 | 102 | ||||
103 | 104 | ||||
105 | 106 | ||||
107 | 108 | ||||
109 | 110 | ||||
111 | 112 | ||||
113 | 114 | ||||
115 | 116 | ||||
117 | 118 | ||||
119 | 120 | ||||
121 | 122 | ||||
123 | 124 | ||||
125 | 126 | ||||
127 | 128 |
Safety Instructions
This equipment is stationary-fixed and must be installed by Service Persons only (Service Person is defined as a person having the appropriate technical training and experience necessary to be aware of hazards to which that person may be exposed in performing a task and of measures to minimize the risks to that person or other persons). It must be installed and used within an environment that provides the pollution degree max 2, over voltages category II, in non-hazardous, indoor locations only.
WARNING : When using equipment connected to the mains and/or to the telecommunication network, there are basic safety instructions that should always be followed. Refer to the safety instructions provided with this product and save them for future reference. To reduce the risk of fire, electric shock and/or injury, observe the following:
- Do not attempt to service this product yourself. Opening or removing the cover can expose you to dangerous voltage or other risk. Refer servicing to qualified service persons.
- Only use authorized accessories with this equipment.
- Do not leave or deposit any object on the top of the cabinet of this equipment. The cabinet as it is installed on the wall is not designed to support any supplementary weight.
- Do not touch the equipment and its connected cables during an electrical storm, there is a risk of electric shock.
- Never touch uninsulated wires or terminals unless the equipment has been disconnected from the mains supply and from the telecommunication network.
- Ensure that cables are positioned so that accidents cannot occur. Connected cables must not be subject to excessive mechanical strain. Do not spill any type of liquid on the equipment.
- Do not subject the connected cables to an excessive mechanical strain.
These safety instructions should not prevent you from contacting the distributor or the manufacturer to obtain any further clarification or answers to your concerns.
Regular Maintenance
Keep your Alarm Controller in optimal condition by following all the
instructions that are included within this manual and/or marked on the
product. It is the end-user and/or installer’s responsibility to ensure that
the disposal of the used batteries is made according to the waste recovery and
recycling regulations applicable to the intended market.
Testing your system
Test all system keypad LEDs, keypad sounders, bells and sirens.
Important: If your system fails to function properly, contact your
installation company.
Important: All smoke detectors must be tested by your smoke detector installer
once per year.
Cleaning
- Clean the unit by wiping with a damp cloth only. Do not use any other liquid.
- Do not use abrasives, thinners, solvents or aerosol cleaners (spray polish) that could enter through holes in the Alarm Controller and cause damage or create hazards.
- Do not wipe the front cover with alcohol.
Locating Detectors and Escape Plan
The following information is for general guidance only and it is recommended that local fire codes and regulations be consulted when locating and installing smoke and CO alarms.
Smoke detectors
Research has shown that all hostile fires generate smoke to a greater or
lesser extent. Experiments with typical fires in homes indicate that
detectable quantities of smoke precede detectable levels of heat in most
cases. For these reasons, smoke alarms should be installed outside of each
sleeping area and on each story of the home.
The following information is for general guidance only and it is recommended
that local fire codes and regulations be consulted when locating and
installing smoke alarms.
It is recommended that additional smoke alarms beyond those required for
minimum protection be installed. Additional areas that should be protected
include: the basement; bedrooms, especially where smokers sleep; dining rooms;
furnace and utility rooms; and any hallways not protected by the required
units. On smooth ceilings, detectors may be spaced 9.1m (30 feet) apart as a
guide.
Other spacing may be required depending on ceiling height, air movement, the
presence of joists, uninsulated ceilings, etc. Consult National Fire Alarm
Code NFPA 72, CAN/ULC-S553-02 or other appropriate national standards for
installation recommendations.
- Do not locate smoke detectors at the top of peaked or gabled ceilings; the dead air space in these locations may prevent the unit from detecting smoke.
- Avoid areas with turbulent air flow, such as near doors, fans or windows. Rapid air movement around the detector may prevent smoke from entering the unit.
- Do not locate detectors in areas of high humidity.
- Do not locate detectors in areas where the temperature rises above 38ºC (100ºF) or falls below 5ºC (41ºF).
- Smoke detectors must always be installed in USA in accordance with Chapter 29 of NFPA 72, the National Fire Alarm Code: 29.5.1.1.
Where required by applicable laws, codes, or standards for a specific type of occupancy, approved single- and multiple-station smoke alarms shall be installed as follows:
- In all sleeping rooms and guest rooms.
- Outside of each separate dwelling unit sleeping area, within 6.4 m (21 ft) of any door to a sleeping room, the distance measured along a path of travel.
- On every level of a dwelling unit, including basements.
- On every level of a residential board and care occupancy (small facility), including basements and excluding crawl spaces and unfinished attics.
- In the living area(s) of a guest suite.
- In the living area(s) of a residential board and care occupancy (small facility).
Fire escape planning
There is often very little time between the detection of a fire and the time
it becomes deadly. It is very important that an emergency escape plan be
developed and rehearsed.
-
Study the possible escape routes from each location within the house. Since many fires occur at night, special attention should be given to the escape routes from sleeping quarters.
-
Escape from a bedroom must be possible without opening the interior door.
Consider the following when making your escape plans: -
Make sure that all border doors and windows are easily opened. Ensure that they are not painted shut, and that their locking mechanisms operate smoothly.
-
If opening or using the exit is too difficult for children, the elderly or handicapped, plans for rescue should be developed. This includes making sure that those who are to perform the rescue can promptly hear the fire warning signal.
-
If the exit is above the ground level, an approved fire ladder or rope should be provided as well as training in its use.
-
Exits on the ground level should be kept clear. Be sure to remove snow from exterior patio doors in winter; outdoor furniture or equipment should not block exits.
-
Each person should know the predetermined assembly point where everyone can be accounted for (e.g., across the street or at a neighbor’s house). Once everyone is out of the building, call the fire department.
-
A good plan emphasizes quick escape. Do not investigate or attempt to fight the fire, and do not gather belongings as this can waste valuable time. Once outside, do not re-enter the house. Wait for the fire department.
-
Write the fire escape plan down and rehearse it frequently so that should an emergency arise, everyone will know what to do. Revise the plan as conditions change, such as the number of people in the home, or if there are changes to the building’s construction.
• Make sure your fire warning system is operational by conducting weekly tests. If you are unsure about system operation, contact your installer.
We recommend that you contact your local fire department and request further information on fire safety and escape planning. If available, have your local fire prevention officer conduct an in-house fire safety inspection.
Carbon monoxide detectors
Carbon monoxide is colorless, odorless, tasteless, and very toxic, it also
moves freely in the air. CO detectors can measure the concentration and sound
a loud alarm before a potentially harmful level is reached. The human body is
most vulnerable to the effects of CO gas during sleeping hours; therefore, CO
detectors should be located in or as near as possible to sleeping areas of the
home.
For maximum protection, a CO alarm should be located outside primary sleeping
areas or on each level of your home. Figure 5 indicates the suggested
locations in the home.
Do NOT place the CO alarm in the following areas:
- Where the temperature may drop below -10ºC or exceed 40ºC
- Near paint thinner fumes
- Within 5 feet (1.5m) of open flame appliances such as furnaces, stoves and fireplaces
- In exhaust streams from gas engines, vents, flues or chimneys
- Do not place in close proximity to an automobile exhaust pipe; this will damage the detector PLEASE REFER TO THE CO DETECTOR INSTALLATION AND OPERATING INSTRUCTION SHEET FOR SAFETY INSTRUCTIONS ND EMERGENCY INFORMATION.
End-user License Agreement
IMPORTANT – READ CAREFULLY
DSC Software purchased with or without Products and Components is copyrighted
and is purchased under the following license terms:
- This End-User License Agreement (“EULA”) is a legal agreement between You (the company, individual or entity who acquired the Software and any related Hardware) and Digital Security Controls, a division of Tyco Safety Products Canada Ltd., a part of Johnson Controls group of companies (“JCI”), the manufacturer of the integrated security systems and the developer of the software and any related products or components (“HARDWARE”) which You acquired.
- If the JCI software product (“SOFTWARE PRODUCT” or “SOFTWARE”) is intended to be accompanied by HARDWARE, and is NOT accompanied by new HARDWARE, You may not use, copy or install the SOFTWARE PRODUCT. The SOFTWARE PRODUCT includes computer software, and may include associated media, printed materials, and “online” or electronic documentation.
- Any software provided along with the SOFTWARE PRODUCT that is associated with a separate end-user license agreement is licensed to You under the terms of that license agreement.
- By installing, copying, downloading, storing, accessing or otherwise using the SOFTWARE PRODUCT, You agree unconditionally to be bound by the terms of this EULA, even if this EULA is deemed to be a modification of any previous arrangement or contract. If You do not agree to the terms of this EULA, DSC is unwilling to license the SOFTWARE PRODUCT to You, and You have no right to use it.
SOFTWARE PRODUCT LICENSE
The SOFTWARE PRODUCT is protected by copyright laws and international
copyright treaties, as well as other intellectual property laws and treaties.
The SOFTWARE PRODUCT is licensed, not sold.
1. GRANT OF LICENSE This EULA grants You the following rights:
Software Installation and Use – For each license You acquire, You may have
only one copy of the SOFTWARE PRODUCT installed.
Storage/Network Use – The SOFTWARE PRODUCT may not be installed, accessed,
displayed, run, shared or used concurrently on or from different computers,
including a workstation, terminal or other digital electronic device
(“Device”). In other words, if You have several workstations, You will have to
acquire a license for each workstation where the SOFTWARE will be used.
Backup Copy – You may make back-up copies of the SOFTWARE PRODUCT, but You may
only have one copy per license installed at any given time. You may use the
back-up copy solely for archival purposes. Except as expressly provided in
this EULA, You may not otherwise make copies of the SOFTWARE PRODUCT,
including the printed materials accompanying the SOFTWARE. 2. DESCRIPTION OF
OTHER RIGHTS AND LIMITATIONS
Limitations on Reverse Engineering, Decompilation and Disassembly – You may
not reverse engineer, decompile, or disassemble the SOFTWARE PRODUCT, except
and only to the extent that such activity is expressly permitted by applicable
law notwithstanding this limitation. You may not make any changes or
modifications to the Software, without the written permission of an officer of
DSC. You may not remove any proprietary notices, marks or labels from the
Software Product.
You shall institute reasonable measures to ensure compliance with the terms
and conditions of this EULA.
Separation of Components – The SOFTWARE PRODUCT is licensed as a single
product. Its component parts may not be separated for use on more than one
HARDWARE unit.
Single INTEGRATED PRODUCT – If You acquired this SOFTWARE with HARDWARE, then
the SOFTWARE PRODUCT is licensed with the HARDWARE as a single integrated
product. In this case, the SOFTWARE PRODUCT may only be used with the HARDWARE
as set forth in this EULA.
Rental – You may not rent, lease or lend the SOFTWARE PRODUCT. You may not
make it available to others or post it on a server or web site.
Software Product Transfer – You may transfer all of Your rights under this
EULA only as part of a permanent sale or transfer of the HARDWARE, provided
You retain no copies, You transfer all of the SOFTWARE PRODUCT (including all
component parts, the media and printed materials, any upgrades and this EULA),
and provided the recipient agrees to the terms of this EULA. If the SOFTWARE
PRODUCT is an upgrade, any transfer must also include all prior versions of
the SOFTWARE PRODUCT.
Termination – Without prejudice to any other rights, DSC may terminate this
EULA if You fail to comply with the terms and conditions of this EULA. In such
event, You must destroy all copies of the SOFTWARE PRODUCT and all of its
component parts.
Trademarks – This EULA does not grant You any rights in connection with any
trademarks or service marks of DSCor its suppliers.
3. COPYRIGHT – All title and intellectual property rights in and to the
SOFTWARE PRODUCT (including but not limited to any images, photographs, and
text incorporated into the SOFTWARE PRODUCT), the accompanying printed
materials, and any copies of the SOFTWARE PRODUCT, are owned by DSC or its
suppliers. You may not copy the printed materials accompanying the SOFTWARE
PRODUCT. All title and intellectual property rights in and to the content
which may be accessed through use of the SOFTWARE PRODUCT are the property of
the respective content owner and may be protected by applicable copyright or
other intellectual property laws and treaties. This EULA grants You no rights
to use such content. All rights not expressly granted under this EULA are
reserved by DSC and its suppliers.
4. EXPORT RESTRICTIONS – You agree that You will not export or re-export the
SOFTWARE PRODUCT to any country, person, or entity subject to Canadian export
restrictions.
5. CHOICE OF LAW – This Software License Agreement is governed by the laws of
the Province of Ontario, Canada.
6. ARBITRATION – All disputes arising in connection with this Agreement shall
be determined by final and binding arbitration in accordance with the
Arbitration Act, and the parties agree to be bound by the arbitrator’s
decision. The place of arbitration shall be Toronto, Canada, and the
installation manual of the arbitration shall be English.
7. LIMITED WARRANTY
NO WARRANTY – DSC PROVIDES THE SOFTWARE “AS IS” WITHOUT WARRANTY. DSC DOES NOT
WARRANT THAT THE SOFTWARE WILL MEET YOUR REQUIREMENTS OR THAT OPERATION OF THE
SOFTWARE WILL BE UNINTERRUPTED OR ERROR-FREE.
CHANGES IN OPERATING ENVIRONMENT – DSC shall not be responsible for problems
caused by changes in the operating characteristics of the HARDWARE, or for
problems in the interaction of the SOFTWARE PRODUCT with non-DSC SOFTWARE or
HARDWARE PRODUCTS.
LIMITATION OF LIABILITY; WARRANTY REFLECTS ALLOCATION OF RISK – IN ANY EVENT,
IF ANY STATUTE IMPLIES WARRANTIES OR CONDITIONS NOT STATED IN THIS LICENSE
AGREEMENT, DSC’S ENTIRE LIABILITY UNDER ANY PROVISION OF THIS LICENSE
AGREEMENT SHALL BE LIMITED TO THE GREATER OF THE AMOUNT ACTUALLY PAID BY YOU
TO LICENSE THE SOFTWARE PRODUCT AND FIVE CANADIAN DOLLARS (CAD$5.00). BECAUSE
SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR
CONSEQUENTIAL OR INCIDENTAL DAMAGES, THE ABOVE LIMITATION MAY NOT APPLY TO
YOU.
DISCLAIMER OF WARRANTIES – THIS WARRANTY CONTAINS THE ENTIRE WARRANTY AND
SHALL BE IN LIEU OF ANY AND ALL OTHER WARRANTIES, WHETHER EXPRESSED OR IMPLIED
(INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE) AND OF ALL OTHER OBLIGATIONS OR LIABILITIES ON THE PART OF
DSC. DSC MAKES NO OTHER WARRANTIES. DSC NEITHER ASSUMES NOR AUTHORIZES ANY
OTHER PERSON PURPORTING TO ACT ON ITS BEHALF TO MODIFY OR TO CHANGE THIS
WARRANTY, NOR TO ASSUME FOR IT ANY OTHER WARRANTY OR LIABILITY CONCERNING THIS
SOFTWARE PRODUCT.
EXCLUSIVE REMEDY AND LIMITATION OF WARRANTY – UNDER NO CIRCUMSTANCES SHALL DSC
BE LIABLE FOR ANY SPECIAL, INCIDENTAL, CONSEQUENTIAL OR INDIRECT DAMAGES BASED
UPON BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE, STRICT LIABILITY, OR
ANY OTHER LEGAL THEORY. SUCH DAMAGES INCLUDE, BUT ARE NOT LIMITED TO, LOSS OF
PROFITS, LOSS OF THE SOFTWARE PRODUCT OR ANY ASSOCIATED EQUIPMENT, COST OF
CAPITAL, COST OF SUBSTITUTE OR REPLACEMENT EQUIPMENT, FACILITIES OR SERVICES,
DOWN TIME, PURCHASERS TIME, THE CLAIMS OF THIRD PARTIES, INCLUDING CUSTOMERS,
AND INJURY TO PROPERTY.
WARNING: DSC recommends that the entire system be completely tested on a
regular basis.
However, despite frequent testing, and due to, but not limited to, criminal
tampering or electrical disruption, it is possible for this SOFTWARE PRODUCT
to fail to perform as expected.
WARNING : JCI recommends that the entire system be completely tested on a
regular basis.
However, despite frequent testing, and due to, but not limited to, criminal
tampering or electrical disruption, it is possible for this SOFTWARE PRODUCT
to fail to perform as expected.
Always ensure you obtain the latest version of the User Manual.
FCC Compliance Statement
Regulatory Information covers models IQ Pro and IQ Pro P
FCC modification statement – Tyco Safety Products has not approved any changes
or modifications to this device by the user. Any changes or modifications
could void the user’s authority to operate the equipment. Tyco Safety Products
Canada Ltd.
FCC AND ISED CANADA INTERFERENCE STATEMENT – This device complies with Part 15
of the FCC Rules. Operation is subject to the following two conditions: (1)
this device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation of the
device. This device complies with ISED Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device.
FCC CLASS B DIGITAL DEVICE NOTICE -This equipment has been tested and found to
comply with the limits for a Class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment
generates uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference
to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or experienced radio/television technician for help.
CAN ICES-3 (B) / NMB-3 (B)
FCC/ISED CANADA WIRELESS NOTICE
This equipment complies with FCC and ISED Canada radiation exposure limits set
forth for an uncontrolled environment. The antenna should be installed and
operated with minimum distance of 20 cm between the radiator and your body.
Copyright and Trademark
The trademarks, logos, and service marks displayed on this document are
registered in the United States [or other countries]. Any misuse of the
trademarks is strictly prohibited and Johnson Controls (JCI) will aggressively
enforce its intellectual property rights to the fullest extent of the law,
including pursuit of criminal prosecution wherever necessary. All trademarks
not owned by JCI are the property of their respective owners, and are used
with permission or allowed under applicable laws.
Product offerings and specifications are subject to change without notice.
Actual products may vary from photos. Not all products include all features.
Availability varies by region; contact your sales representative.
© 2022 Johnson Controls. All rights reserved. Johnson Controls, Tyco and DSC
are trademarks and/ or registered trademarks. Unauthorized use is strictly
prohibited.
Tech support: 1-800-387-3630 (Canada
and U.S), or 1-905-760-3036
(International)
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>