QUICK PUMP 8 kg Semi Automatic Top Loading Washing Machine Instruction Manual
- June 16, 2024
- QUICK PUMP
Table of Contents
8 kg Semi Automatic Top
Loading Washing Machine
Instruction Manual
8 kg Semi Automatic Top Loading Washing Machine
GENERAL SAFETY GUIDELINES FOR ELECTRICAL DEVICES
Portable digital pump with built-in 2.000 mah (x2) battery
Be careful: whenever you use an electric tool, please follow these basic safety guidelines to reduce the risk of a fire, electric shocks and personal injury. Read this manual carefully before using the device. Keep this manual in a safe place.
-
Keep your work area clean and tidy.
An untidy work area increases the risk of personal injury. -
Consider the environmental conditions of your work area.
Never use electric tools in the rain. Do not use electric tools in wet or damp areas.
Keep your work area well lit. Do not use electric tools near flammable liquids or gasoline. -
Protect yourself from electric shocks.
Whenever using an electric tool, avoid touching grounded surfaces (pipes, radiators, shelves, refrigerators). -
Keep children away from electric tools.
Do not let anyone come into contact with the tool or power cord.
Keep all visitors away from your work area. This device is not intended for use by persons (including children) with reduced physical, sensory or mental capacity or those who lack experience or knowledge unless supervised or under proper instruction on the use of this device from a person responsible for their safety. Children must be supervised at all times to ensure they do not play with the device. -
Put tools away when they are not being used.
Whenever not in use, tools should be kept in a sealed and dry location out of reach of children. -
Do not force the tool.
It will operate most efficiently and safely at the normal power level for which it was designed. -
Use the tool properly.
Do not force small tools to do tasks for which a heavy tool should be used.
Only use tools for their intended purpose. -
Wear suitable clothing.
Do not wear loose clothing or jewellery. This may get caught in moving parts. The use of rubber gloves and non-slip shoes is recommended when working outdoors. Cover your head to protect long hair. -
Wear suitable safety goggles.
If necessary, wear eye protection or an anti-dust face mask. -
Do not mistreat the power cord.
Never carry the tool from the power cord or pull the power cord to unplug it.
Keep the power cord away from heat sources, all liquids and sharp edges. -
Do not work in an uncomfortable position.
Maintain a logical and balanced working position at all times. -
Pay attention to tool maintenance requirements.
Keep tools clean so they function properly and safely. Follow standard maintenance procedures. Check the cables and extensions on the tool regularly. If they are damaged, contact an authorised service technician for the corresponding repairs. Keep the handle dry, clean and free of grease and oil. -
Unplug the tools.
Unplug the tools whenever they are not being used or for performing maintenance. -
Avoid accidental power on situations.
Never carry a tool that is plugged in with your finger on the power switch. Turn off the power switch before plugging it in. -
Stay alert.
Use common sense. Pay attention to your work. Do not use the tool when you are too tired. -
Check to see if any parts are damaged.
Before using the tool, check to see if any parts are damaged to guarantee safe operation.
Check the alignment of moving parts to see whether any are broken, to make sure they are attached properly, whether the tool is assembled correctly and any other condition that might affect safe operation. Any damaged protective device or part should be replaced or repaired by an authorised service technician. Do not use the tool if the power switch does not turn on or off correctly. Have an authorised service technician replace the switch if it is faulty. -
Warning.
The use of any accessory other than those recommended in this manual may increase the risk of personal injury. -
Damaged power cord.
If the power cord is damaged, this should only be replaced by the manufacturer or the technical service indicated by the distributor. In either case, they should be qualified to perform this task.
Keep these instructions in a safe place.
WARNINGS AND LABELS
You will find a label on the inflator with relevant information about this device. Pay special attention to this information as it is important for your safety. Read the instruction manual before starting to use the inflator and do not remove the labels.
LOOKING AFTER THE ENVIRONMENT
Recycle the packaging material responsibly, as well as the inflator itself, instead of throwing them away with the rubbish.
SYMBOLS
The labelling that comes with this device contains symbols and tags with important information and recommendations that you should read and follow carefully.
BEFORE USE
Unpack the product and check it carefully for any possible damage during transport. Read the instruction manual. Familiarise yourself with the correct use of the product. Incorrect use of the product may lead to material damages or personal injury.
TECHNICAL SPECIFICATIONS
Main characteristics | 83002050 |
---|
EAN 8429586117001
Dimensions (Length x Height x Width)| 14 x 8,5 x 4,8 cm
Weight| 0,42 kg
Packaging dimensions| 17 x 9 x 7,8 cm
Accessories included| lx fine nozzle
lx wide nozzle
lx small valve adapter lx large valve adapter
lx needle nozzle
Voltage| 2.000 mah (x2) battery – 7.4V
Maximum recommended pressure| 44-58 PSI/3-4 Bar
Maximum current| 7 A
Time to inflate a Tyre
(of 205/70R15 to 0-35 PSI)| ≤ 511”
Minimum current| 3-4 A
Air flow| ≤ 17 L / min
Pressure range (PSI/BAR)| 0-150/0-10
Accuracy| ± 2 psi
I Air hose length| 25 cm
Power| 50 W
Noise level| 70-75 dB
Main recommended uses|
ON/OFF| Yes
Emergency light| Yes
GENERAL SAFETY INSTRUCTIONS: RECOMMENDATIONS FOR THE USER. AVOID
OVERINFLATION. NEVER EXCEED THE RECOMMENDED PRESSURE. EXCESSIVE PRESSURE MAY
CAUSE SERIOUS DAMAGE TO THE ITEM BEING INFLATED AND PERSONAL INJURY TO THE
USE.
This manual contains important information that you should know and
understand. It is provided for your safety and to prevent problems with this
unit. Read the instructions carefully to guarantee safe operation. Always use
a pressure gauge to know the current pressure in your tyres.
Maintaining the correct pressure in your tyres reduces fuel consumption,
improves vehicle performance, handling and driving, extends the lifespan of
your tyres and prevents punctures or faults due to excessive pressure.
a) For inflatables (balls, armbands, lilts, etc.) without a pressure readout,
avoid overinflating the item. Most vehicle tyres can be inflated to a pressure
of 24-32 PSI, depending on the type of wheel in question. Certain road bikes
require a pressure of more than 40 PSI. City and mountain bikes require lower
pressures. Never surpass a pressure of 80 PSI.
b) Keep your hands away from the pump while it is in use.
c) Do not leave the pump in operation unattended. If it is not being used,
switch off and unplug the device.
d) When using the pump, make sure that the car engine is not running.
e) Required power source: Built-in 2.000 mah (x2) battery with USB-C charging
cable
f) Before putting the pump away, make sure it has cooled completely.
g) Do not drag or carry the pump by the power cord.
h) Do not aim the air jet at yourself or others. Compressed air can be
dangerous.
i) Only use the accessories included with the product.
j) This pump has NOT been designed for commercial applications.
k) Improper use of the power cord and plug may lead to electric shocks.
l) This pump has been designed for occasional use. Using it continuously for a
long period of time may cause damage. We recommend not using it for more than
8 / 10 minutes without stopping. For every 10 minutes in continuous
operation, switch off the product for another 10 minutes.
m) Do not use the air pump on high-pressure rims (e.g., large lorries,
trailers or tractors).
This pump has not been designed to function continuously for the time needed
to inflate this kind of tyres.
n) Do not hold or carry the pump in your hand while it is in operation. It
should be placed on the ground.
o) If the pump makes strange noises related to possible over-heating, unplug
it immediately and disconnect the power cord. Leave it to cool for at least 40
minutes.
p) Do not try to modify the original design of this pump.
q) If the pump is not going to be used for an extended period of time, keep it
in a safe, dry place.
Keep out of reach of children This device is not intended for use by persons
(including children) with reduced physical, sensory or mental capacity or
those who lack experience or knowledge unless supervised or under proper
instruction on the use of this device from a person responsible for their
safety. Children must be supervised at all times to ensure they do not play
with the device.
Always consult the manual for the item to be inflated to know the correct
pressure.
NOZZLES AND ADAPTERS
Item | PSI | Required nozzle |
---|---|---|
Car tyres | 24-32 | No adaptor necessary |
Bicycle Tyre (SCHRADER) | 35-40 | No adaptor necessary |
Football | 13 | Needle nozzle |
Basketball | 9 | Needle nozzle |
Volleyball | 5 | Needle nozzle |
Lawnmower Tyre | 22 | No adaptor necessary |
Inflatable dinghy (max. 2 persons) | Firm | Fine / wide nozzle |
Inflatable lilt | Firm | Fine / wide nozzle |
PRODUCT DESCRIPTION
The QUICK PUMP from SALKI has been designed for emergency roadside situations and for inflating bicycle tyres, balls used in sport and other inflatables. Various nozzles are included with the product for various inflatable items.
ACCESSORIES
HOW TO INFLATE A TYRE
- Connect the air hose to the pump.
- Connect the other end of the air hose to the valve on the Tyre you want to inflate.
- Switch the power button to the “ON” position by sliding it to one side.
- Press M briefly to activate the device.
- If you hold M for three seconds, you can select the pressure unit to be used. The options are: PSI, Bar, KPA or kg / cm².
- If you hold down the circular arrows button, you can select between the four different smart modes: Car, Motorcycle, Bicycle and Balls.
- Use the + / – keys to pre-select the desired pressure. Then wait for three seconds so the chosen value is set.
- Start inflating with the M button.
- When the set pressure is reached, the pump will stop automatically. You can stop it at any time by pressing M again.
- Make sure to close the pump after use to save battery.
The device is fitted with a light function, energy saving function and environmental protection function, especially for nocturnal use. You can always keep the light on, even during or after its use as an indicator.
FOR INFLATABLES
- Choose the right adapter and attach it to the connector.
- For reference and recommendation purposes only, check our TYPICAL AIR PRESSURE table. Do not forget to consult the user manual for the item you are inflating to know the exact and recommended pressure.
- Attach the nozzle and insert the universal connector.
- Start inflating.
- When the desired pressure is reached, flip the power switch to “OFF”.
- Remove the adaptor from the item you are inflating and remove the adaptor from the connector.
TROUBLESHOOTING
THE PUMP DOES NOT START
- Check that the pump battery is charged.
- Check that the charger works correctly.
THE PUMP STARTS BUT DOES NOT INFLATE ANYTHING
- Make sure that the connector is properly secured to the valve.
- Check the item you are inflating for leaks.
- Check the air hose for connection faults and leaks.
THE PUMP WORKS BUT VERY SLOWLY
- Possible over-heating due to excessive use. Switch it off and let it cool for 30 minutes.
- Low voltage. Check the battery level on the device.
REPAIRS
-
Before charging the pump, check the power cord for any possible damage. Only a
qualified technician from the manufacturer or distributor should check and repair the
product. -
Any improper use of the device by the user voids the warranty offered by the distributor.
CONVERSION TABLE
PSI | KPA | BAR |
---|---|---|
10 | 68,9 | 0,69 |
20 | 137,9 | 1,38 |
30 | 206,8 | 2,07 |
40 | 275,8 | 2,76 |
50 | 344,7 | 3,45 |
70 | 482,6 | 4,83 |
80 | 551,6 | 5,52 |
90 | 620,5 | 6,21 |
100 | 689,5 | 6,90 |
125 | 861,9 | 8,62 |
Grupodesa Fasteners, S.A.U.
C / Basters 29, Polygon Industrial Palau del Reig
43800 Valls – Tarragona (Espino)
(+34) 902 32 31 30 | info@grupodesa.es
www.salki.es
NIF A-31017494
EC DECLARATION OF CONFORMITY
The undersigned, as the CEO of the company indicated
above, with registered address as shown on the letterhead of this document,
HEREBY DECLARES:
That the tool:
Model QUICK PUMP
Ref 83002050
Meets the requirements and conditions established in EU Directive
2006 / 42 (MD), EMC (2014 / 30), Rohus (2011 / 65).
EN 1012-1:2010
EN 60335-1:2012
EN 62233:2008
Signed and stamped in Valls, June 1, 2023.
Company stamp Grupodesa Fasteners, S.A.U
Cl Basters, 29 Pol. Ind. Palau de Reig
43800 Valls, Tarragona (Espino)
www.grupodesa.es Grupodesa Fasteners, S.A.U.
C / Basters 29, Polygon Industrial Palau del Reig
43800 Valls – Tarragona
(+34) 902 32 31 30 | info@grupodesa.es
www.salki.es
NIF A-31017494
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>