ETRX35x ZIGBEE MODULES
PRODUCT MANUAL
ETRX351 and ETRX357
ETRX351 Zigbee Modules
The Telegesis ETRX351 and ETRX357 modules are low power 2.4GHz Zigbee modules,
based on the latest Ember EM351 and EM357 single chip Zigbee™ solutions.
These 3rd generation modules have been designed to be integrated into any
device without the need for RF experience and expertise. Utilizing the
EmberZNet Zigbee stack, the ETRX35x enables you to add powerful wireless
networking capability to your products and quickly bring them to market.
The module’s unique AT-style command line interface allows designers to
quickly integrate Zigbee technology without complex software engineering. For
custom application development the ETRX35x series integrates with ease into
Ember’s InSight development environment.
Module Features
- Small form factor, SMT module 25mm x 19mm
- Side Castellations for easy soldering and optical inspection
- 2 antenna options: Integrated chip antenna or U.FL coaxial connector
- Industry’s first ARM® Cortex-M3 based family of Zigbee modules
- Industry standard JTAG Programming and real time network level debugging via the Ember InSight Port
- 192kB (ETRX357) and 128kB (ETRX351) flash and 12kbytes of RAM
- Lowest Deep Sleep Current of sub 1µA and multiple sleep modes
- Wide supply voltage range (2.1 to 3.6V)
- Optional 32.768kHz watch crystal can be added externally
- Module ships with standard Telegesis AT-style command interface based on the Zigbee PRO feature set
- Can act as an End Device, Router or Coordinator
- 24 general-purpose I/O lines including analogue inputs (all GPIOs of the EM35x are accessible)
- Firmware upgrades via serial port or over the air (password protected)
- Hardware supported encryption (AES-128)
- CE and UKCA; FCC and IC compliance, FCC modular approval
- Operating temperature range: -40°C to +85 °C
- Long range version with a link budget of up to 124dB available in the same form factor
Radio Features
- Based on the Ember EM351 or EM357 single chip Zigbee solutions
- 2.4GHz ISM Band
- 250kbit/s over the air data rate
- 16 channels (IEEE802.15.4 Channel 11 to 26)
- +3dBm output power ( +8dBm in boost mode)
- High sensitivity of -100dBm (-102dBm in boost mode) typically @ 1% packet error rate
- RX Current: 26mA, TX Current: 31mA at 3dBm
- Robust Wi-Fi and Bluetooth coexistence
Suggested Applications
- AMR – Zigbee Smart Energy applications
- Wireless Alarms and Security
- Home/Building Automation
- Wireless Sensor Networks
- M2M Industrial Controls
- Lighting and ventilation control
- Remote monitoring
- Environmental monitoring and control
Development Kit
- New Development kit containing everything required to set up a mesh network quickly and evaluate range and performance of the ETRX35x and its long-range version.
- AT-style software interface command dictionary can be modified for high volume customers.
- Custom software development available upon request.
Example AT-Style Commands
AT+BCAST | Send a Broadcast |
---|---|
AT+UCAST: | Send a Unicast |
AT+EN | Establish PAN network |
AT+JN | Join PAN |
At power-up the last configuration is loaded from non-volatile S-Registers, which can eliminate the need for an additional host controller.
Introduction
This document describes the Telegesis ETRX351 and ETRX357 Zigbee modules which
have been designed to be easily integrated into another device and to provide
a fast, simple and low cost wireless mesh networking interface.
The Telegesis ETRX3 series modules are based on the Ember Zigbee platform
consisting of the single chip EM351 or EM357 combined with the Zigbee PRO
compliant EmberZNet meshing stack. Integration into a wide range of
applications is made easy using a simple AT style command interface and
advanced hardware design.
The configurable functionality of the Telegesis AT Commandset often allows the
ETRX3 series Zigbee modules to be used without an additional host
microcontroller saving even more integration time and costs. In addition to
the Telegesis AT Commandset, the ETRX351 and ETRX357 modules can be used with
custom-built firmware whilst representing an ideal platform for custom
firmware development in conjunction with the Ember development kits.
No RF experience or expertise is required to add this powerful wireless
networking capability to your products. The ETRX351 and ETRX357 offer fast
integration opportunities and the shortest possible time to market for your
product.
1.1 Hardware Description
The main building blocks of the ETRX351 and ETRX357 are the single chip EM351
and EM357 SoCs from Ember, a 24MHz reference crystal and RF front-end
circuitry optimized for best RF performance. The modules are available with
on-board antenna or alternatively a U.FL coaxial connector for attaching
external antennae. Modules with the U.FL connector are identified by the “HR”
suffix.
The integrated antenna is an Antenova Rufa, and details of the radiation
pattern etc are available from the Antenova website Fehler! Verweisquelle
konnte nicht gefunden werden..
Module | Chip | Flash | RAM |
---|---|---|---|
ETRX351 | EM351 | 128kB | 12kB |
ETRX351HR | EM351 | 128kB | 12kB |
ETRX357 | EM357 | 192kB | 12kB |
ETRX357HR | EM357 | 192kB | 12kB |
Table 1: Memories
The ETRX351 and ETRX357 are used for Zigbee (www.zigbee.org) applications. In case it is desired to develop custom firmware instead of using the pre-loaded AT-Command interface, the Ember InSight toolchain, consisting of InSight Desktop™ together with a comprehensive integrated development environment (IDE), is required. The Ember development environment is currently not suitable for developing an IEEE802.15.4-only application that does not use the Zigbee layer.
Product Approvals
The ETRX351 and ETRX357 as well as the ETRX351HR and ETRX357HR have been designed to meet all national regulations for world-wide use. In particular the following certifications have been obtained:
2.1 FCC Approvals
The Telegesis ETRX351 and ETRX357 with integrated Antenna as well as the
ETRX351HR and the ETRX357HR including the antennas listed in Table 2 have been
tested to comply with FCC CFR Part 15 (USA) The devices meet the requirements
for modular transmitter approval as detailed in the FCC public notice
DA00.1407.transmitter.
FCC statement:
This device complies with Part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired
operation.
**** FCC ID: S4GEM35XA
Item | Part No. | Type | Impedance | Gain |
---|---|---|---|---|
1 | BT-Stubby (straight) | ¼ Wave | 50Ω | 0dBi |
2 | BT-Stubby (right- angle) | ¼ Wave | 50Ω | 0dBi |
3 | WH-2400-U2.5 | ½ Wave | 50Ω | 2.5dBi |
4 | Rufa (on board) | Chip | 50Ω | 2.1dBi (peak) |
Table 2: Approved Antennae
While the applicant for a device into which the ETRX351 (ETRX357) or ETRX351HR
(ETRX357HR) with an antenna listed in Table 2 is installed is not required to
obtain a new authorization for the module, this does not preclude the
possibility that some other form of authorization or testing may be required
for the end product.
The FCC requires the user to be notified that any changes or modifications
made to this device that are not expressly approved by Telegesis (UK) Ltd. may
void the user’s authority to operate the equipment.
When using the ETRX351HR and ETRX357HR with approved antennae, it is required
to prevent end-users from replacing them with non-approved ones. The module
and associated antenna must be installed to provide a separation distance of
at least 20cm from all persons and must not transmit simultaneously with any
other antenna or transmitter.
2.1.1 FCC Labelling Requirements
When integrating the ETRX351, ETRX357, ETRX351HR or ETRX357HR into a
product it must be ensured that the FCC labelling requirements are met. This
includes a clearly visible label on the outside of the finished product
specifying the Telegesis FCC identifier (FCC ID: S4GEM35XA) as well as the FCC
notice shown on the previous page. This exterior label can use wording such as
“Contains Transmitter Module FCC ID: S4GEM35XA” or “Contains FCC ID:S4GEM35XA”
although any similar wording that expresses the same meaning may be used.
2.2 IC (Industry Canada) Approvals
The Telegesis ETRX351 and ETRX357 with integrated Antenna as well as the
ETRX351HR and the ETRX357HR modules have been approved by Industry Canada to
operate with the antenna types listed in Table 2 with the maximum permissible
gain and required antenna impedance for each antenna type indicated. Antenna
types not included in this list, having a gain greater than the maximum gain
indicated for that type, are strictly prohibited for use with this device.
IC-ID: 8735A-EM35XA
-
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. -
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication.
-
This module complies with FCC and Industry Canada RF radiation exposure limits set forth for general population. To maintain compliance, this module must not be co- located or operating in conjunction with any other antenna or transmitter.
-
This device has been designed to operate with the antennas listed in Table 2 and having a maximum gain of 2.5 dBi. Antennas not included in this list or having a gain greater than 2.5 dBi are strictly prohibited for use with this device. The required antenna impedance is 50 ohms.
The labelling requirements for Industry Canada are similar to those of the
FCC. Again, a clearly visibly label must be placed on the outside of the
finished product stating something like “Contains Transmitter Module, IC:
8735A-EM35XA”, although any similar wording that expresses the same meaning
may be used.
The integrator is responsible for the final product to comply to IC ICES-003
and FCC Part 15, Sub. B – Unintentional Radiators.
2.3 CE (EU) and UKCA (UK) Compliance
The ETRX351, ETRX357, ETRX351HR and ETRX357HR modules conform with the
essential requirements and other relevant requirements of the EU’s Radio
Equipment Directive (RED) (2014/53/EU) and the UK’s Radio Equipment
Regulations (RER) (S.I. 2017/1206). Compliance is demonstrated by verification
against numerous standards, including the following:
-
Radio: EN 300 328 v2.2.2
-
EMC: EN 301 489-17 v3.1.1
EN 301 489-1 V2.1.1 -
Safety: EN62368-1:2020+A11:2020
Please note that every application using the modules will need to perform the
radio EMC tests on the end product, according to EN 301 489-17. It is
ultimately the responsibility of the manufacturer to ensure the compliance of
the end product. The specific product assembly may have an impact to RF
radiated characteristics, and manufacturers also should carefully consider RF
radiated testing with the end-product assembly.
The modules conform with the directive and regulations mentioned above when
using the antennae listed in Table 2.
The modules are entitled to carry the CE and UKCA compliance marks, and the
formal
Declarations of Conformity (DoC) are available on the product web page, which
is reachable starting from www.silabs.com.
2.4 ICASA Approvals
The ETRX351, ETRX357, ETRX351HR and ETRX357HR have been certified to be used
in South Africa.
2.5 Australia and New Zealand (C-Tick)
The ETRX351, ETRX357, ETRX351HR and ETRX357HR have been certified to be used
in Australia and New Zealand.
In order to have a C-Tick mark on an end product integrating an ETRX35x
device, a company must comply with a or b below.
a). have a company presence in Australia.
b). have a company/distributor/agent in Australia that will sponsor the
importing of the end product.
2.6 Brazil
The ETRX357 and ETRX357HR have been certified to be used in Brazil. The Anatel
ID for both module variants is 03190-19-03402. To comply to Brazilian
regulations, it is required to display Anatel related information including,
but not limited to the graphics below in the end-product’s user guide.
2.7 IEEE 802.15.4
IEEE 802.15.4 is a standard for low data-rate, wireless networks (raw bit-rate
within a radio packet of 250kbps @2.4GHz) which focuses on low cost, low duty
cycle, long primary battery life applications as well as mains-powered
applications. It is the basis for the open Zigbee Protocol.
2.8 The Zigbee Protocol
The Zigbee Protocol is a set of standards for wireless connectivity for use
between any devices over short to medium distances. The specification was
originally ratified in December 2004, paving the way for companies to start
making low-power networks a reality.
Zigbee uses the IEEE 802.15.4 radio specification running on the 2.4GHz band,
plus three additional layers for networking, security and applications. What
makes the specification unique is its use of a mesh network architecture
which, in bucket chain style, passes data from one node to the next until it
lands at its destination. The network is self-healing and adapts its routing
as link quality changes or nodes move. Furthermore, nodes can be defined as
End Devices which do not act as routers, but can therefore be put into a low-
power sleep state.
The enhanced version of the Zigbee standard (or Zigbee 2006) was released in
December 2006, adding new features and improvements to the only global
wireless communication standard enabling the development of easily deployable
low-cost, low-power, monitoring and control products for homes, commercial
buildings and industrial plant monitoring. In 2007 the Zigbee Alliance
introduced the PRO feature set which offers advantages over earlier versions,
including
- Truly self-healing mesh networking
- Messages can now travel up to 30 hops
- Source-Routing for improved point to multipoint message transmission
- Improved security including Trust-Centre link keys
- New message types and options
The Telegesis AT-Commandset, which by default ships on all ETRX3 series products, is based on the ZigBee PRO featureset. For more information on the Telegesis AT-Commandset please refer to the separate documentation at www.telegesis.com.
Module Pinout
The table below gives details about the pin assignment for direct SMD
soldering of the ETRX3 series modules to the application board. For more
information on the alternate functions please refer to [2]. Also refer to the
Telegesis AT Commandset ocumentation and the Telegesis development kit
documentation to understand how the pre-programmed firmware makes use of the
individual I/Os.
All GND pads are connected within the module, but for best RF performance all
of them should be grounded externally ideally to a ground plane.
“Important Note: If designers would like to keep open the option of using
either standard or long- range modules in the same product please note the
following. The ETRX35x series and the ETRX35x-LRS series of modules are
footprint compatible, but on the ETRX35x-LRS series pins PB0 and PC5 of the
EM357 are used internally to control the front-end module and are not
available to the user.”
ETRX35x Pad| Name| EM35x Pin| Default use|
Alternate Functions
---|---|---|---|---
1| GND| GND| GND|
2| PC5 {1}| 11| | TX_ACTIVE
3| PC6| 13| I/O| OSC32B, nTX_ACTIVE
4| PC7| 14| I/O| OSC32A, OSC32_EXT
5| PA7 {5}| 18| I/O| TIM1C4
6| PB3 {2,3}| 19| I/O, CTS| SC1nCTS, SC1SCLK, TIM2C3
7| nReset {6}| 12| nReset|
8| PB4 {2,3}| 20| I/O, RTS| TIM2C4, SC1nRTS, SC1nSSEL
9| PA0| 21| I/O| TIM2C1, SC2MOSI
10| PA1| 22| I/O| TIM2C3, SC2SDA, SC2MISO
11| PA2| 24| I/O| TIM2C4, SC2SCL, SC2SCLK
12| PA3| 25| I/O| SC2nSSEL, TRACECLK, TIM2C2
13| GND| GND| GND|
14| PA4| 26| I/O| ADC4, PTI_EN, TRACEDATA
15| PA5 {4}| 27| I/O| ADC5, PTI_DATA, nBOOTMODE, TRACEDATA3
16| PA6 {5}| 29| I/O| TIM1C3
17| PB1 {3}| 30| TXD| SC1MISO, SC1MOSI, SC1SDA, SC1TXD, TIM2C1
18| PB2 {3}| 31| RXD| SC1MISO, SC1MOSI, SC1SCL, SC1RXD, TIM2C2
19| GND| GND| GND|
20| GND| GND| GND|
21| JTCK| 32| | SWCLK
22| PC2| 33| I/O| JTDO, SWO
23| PC3| 34| I/O| JTDI
24| PC4| 35| I/O| JTMS, SWDIO
25| PB0| 36| I/O, IRQ| VREF, IRQA, TRACECLK, TIM1CLK, TIM2MSK
26| PC1| 38| I/O| ADC3, SWO, TRACEDATA0
27| PC0 {5}| 40| I/O| JRST, IRQD, TRACEDATA1
28| PB7 {5}| 41| I/O| ADC2, IRQC, TIM1C2
29| PB6 {5}| 42| I/O| ADC1, IRQB, TIM1C1
30| PB5| 43| I/O| ADC0, TIM2CLK, TIM1MSK
31| GND| GND| GND|
32| Vcc| Vcc| Vcc|
33| GND| GND| GND|
Table 3: Pin Information
Notes:
- When the alternate function is selected, TX_ACTIVE becomes an output that indicates that the EM35x radio circuit is in transmit mode. PC5 is not usable on the long-range version of the ETRX35x as this GPIO is used internally as TX_ACTIVE to control the external RF frontend.
- The serial UART connections TXD, RXD, CTS and RTS are PB1, PB2, PB3 and PB4 respectively. The device sends its data on TXD and receives on RXD.
- When using the Telegesis AT Commandset, RTS/CTS handshaking is selectable in firmware. See the AT Command Manual.
- If PA5 is driven low at power-up or reset the module will boot up in the bootloader
- PA6, PA7, PB6, PB7 and PC0 can drive high current (see section 8)
- nRESET is level-sensitive, not edge-sensitive. The module is held in the reset state while nRESET is low.
See also the table “Module pads and functions” in the ETRX357 Development Kit
Product Manual.
Refer to Ember’s EM357 manual for details of the alternate functions and pin
names.
Hardware Description
The ETRX351, ETRX351HR, ETRX357 and ETRX357HR are based on the Ember EM351 and
EM357 respectively. The EM351 and EM357 are fully integrated 2.4GHz Zigbee
transceivers with a 32-bit ARM® Cortex M3™ microprocessor, flash and RAM
memory, and peripherals.
The industry standard serial wire and JTAG programming and debugging
interfaces together with the standard ARM system debug components help to
streamline any custom software development.
In addition to this a number of MAC functions are also implemented in hardware
to help maintaining the strict timing requirements imposed by the Zigbee and
IEEE802.15.4 standards.
The new advanced power management features allow faster wakeup from sleep and
new power down modes allowing this 3rd generation module to offer a longer
battery life than any 2nd generation modules on the market.
The EM35x has fully integrated voltage regulators for both required 1.8V and
1.25V supply voltages. The voltages are monitored (brown-out detection) and
the built-in power-on-reset circuit eliminates the need for any external
monitoring circuitry. An optional 32.768 kHz watch crystal can be connected
externally to pads 3 and 4 in case more accurate timing is required. To
utilize the external watch crystal custom firmware is required.
4.1 Hardware Interface
All GPIO pins of the EM351 or EM357 are accessible on the module’s pads.
Whether signals are used as general purpose I/Os or assigned to a peripheral
function like ADC is set by the firmware.
When using the Telegesis AT Commandset please refer to the AT Commandset
manual and the development kit manual for this information and when developing
custom firmware please refer to the EM35x data sheet [2].
Firmware Description
The modules will be pre-loaded with a standalone bootloader which supports
over-the-air bootloading as well as serial bootloading of new firmware.
In order to enter the standalone bootloader using a hardware trigger pull PA5
to ground and power- cycle or reset the module. To avoid entering the
standalone bootloader unintentionally make sure not to pull this pin down
during boot-up unless the resistance to ground is >10kΩ. (A pull-up is not
required).
In addition to the standalone bootloader the modules also contain the current
release of the Telegesis AT-style command interface as described in the
Telegesis AT command dictionary and the Telegesis user guide. Check
www.telegesis.com for updates. Each module comes
with a unique 64-bit 802.15.4 identifier which is stored in non-volatile
memory. The commands and responses pass through the serial port of the ETRX35x
as ASCII text, so a simple terminal application will usually suffice. We
provide Telegesis Terminal for interaction with the module, but it is not an
essential feature.
The pre-loaded AT-style command interface firmware is based on the latest EmberZNet meshing stack which implements routers/coordinators as well as (sleepy) end devices. [End devices have no routing responsibility and therefore are allowed to go to sleep, whilst still being able to send and receive messages via a parent router. In addition to classical sleepy and non- sleepy end devices the module firmware also supports mobile (sleepy) end devices capable of changing their parent quickly whenever they change their position within the network.]
A router is typically a mains powered device whilst a sleepy end device (SED) can be battery powered.
The module is also able to act as a coordinator and Trust Centre through
external host control. The AT style command line supplies all the tools
required to set up and manage a Zigbee network by allowing easy access to the
low-level functionality of the stack.
The Telegesis firmware uses the meshing and self- healing EmberZNet PRO stack
to overcome many of the limitations of the tree network topology of the Zigbee
2006 stack by using the Zigbee PRO featureset.
The Telegesis firmware allows low-level access to physical parameters such as
channel and power level. Parameters that define the functionality of the
ETRX35x module and also allow standalone functionality are saved in non-
volatile memory organised in so-called S-Registers. The SPI and I2C buses are
not supported by the current firmware release but can be used with custom
firmware.
5.1 Token Settings
The ETRX3 Series Modules’ tokens will be pre-programmed with the settings
shown in the table below.
Token | Description | TG Default |
---|---|---|
MFG_CIB_OBS | Option Bytes | |
MFG_CUSTOM_VERSION | Optional Version Number | |
MFG_CUSTOM_EUI_64 | Custom EUI | |
MFG_STRING | Device Specific String | TELEGESIS |
MFG_BOARD_NAME | Hardware Identifier | |
MFG_MANUF_ID | Manufacturer ID | 0x1010 |
MFG_PHY_CONFIG | Default Power Settings | 0xFF26 |
MFG_BOOTLOAD_AES_KEY | Bootloader Key | |
MFG_EZSP_STORAGE | EZSP related | |
MFG_CBKE_DATA | SE Security | |
MFG_INSTALLATION_CODE | SE Installation | |
MFG_OSC24M_BIAS_TRIM | Crystal Bias |
Table 4. Manufacturing tokens
5.2 Custom Firmware
For high volume customers the firmware can be customised on request. In
addition to this the ETRX3 series of modules is an ideal platform for
developing custom firmware. In order to develop custom firmware, the Ember
Insight toolchain is required.
5.3 Software Interface
Using the default firmware, the ETRX35x is controlled using a simple AT-style
command interface and (mostly) non-volatile S-Registers. In order to get a
full listing of all the available AT-Commands, please refer to the AT command
dictionary document which corresponds to the firmware revision you intend to
use.
In addition to the command dictionary there are user guides explaining the
features of the firmware in more detail. If you need to find out which
firmware resides on your module, simply type “ATI” followed by a carriage
return and you will be prompted with the module’s manufacturing information.
The Development Kit manual describes how to upgrade the firmware either via a
serial link or over the air.
Absolute Maximum Ratings
No. | Item | Symbol | Absolute Maximum Ratings | Unit |
---|---|---|---|---|
1 | Supply voltage | VCC | -0.3 to +3.6 | Vdc |
2 | Voltage on any Pad | Vin | -0.3 to VCC +0.3 | Vdc |
3 | Voltage on any Pad pin (PA4, PA5, PB5, PB6, PB7, PC1), when used as an | |||
input to the general-purpose ADC withthe low voltage range selected | Vin | -0.3 | ||
to +2.0 | Vdc | |||
4 | Module storage temperature range | T stg | -40 to +105 | °C |
5 | Reel storage temperature range | T strgreel | 0 to 75 | °C |
6 | Operating temperature range | Top | -40 to +85 | °C |
7 | Input RF level | Pmax | 15 | dBm |
8 | Reflow temperature | TDeath | Please refer to chapter 12 | °C |
Table 5: Absolute Maximum Ratings
The absolute maximum ratings given above should under no circumstances be
violated. Exceeding one or more of the limiting values may cause permanent
damage to the device.
Caution! ESD sensitive device. Precautions should be used when handling
the device in order to prevent permanent damage.
6.1 Environmental Characteristics
No.| Item| Symbol| Absolute Maximum Ratings|
Unit
---|---|---|---|---
1| ESD on any pad according to Human Body Model (HBM) circuit description|
VTHHBM| ±2| kV
2| ESD on non-RF pads according to Charged Device Model (CDM) circuit
description| VTHCDM| ±400| V
3| ESD on RF terminal according to Charged Device Model (CDM) circuit
description| VTHCDM| ±225| V
4| Moisture Sensitivity Level| MSL| MSL3|
6.2 Recommended Operating Conditions
No. | Item | Conditon/ Remark | Symbol | Value | Unit |
---|---|---|---|---|---|
Min | Typ | ||||
1 | Supply voltage | VCC | 2.1 | ||
2 | RF Input Frequency | fC | 2405 | ||
3 | RF Input Power | pIN | **** | ||
4 | Operating temperature range | Top | -40 |
DC Electrical Characteristics
VCC= 3.0V, TAMB = 25°C, NORMAL MODE (non-Boost) unless otherwise stated
No.| Item| Condition / Remark| Symbol| Value|
Unit
---|---|---|---|---|---
Min| Typ| | Max
1| Module supply voltage| | VCC| 2.1| 3.6| Vdc
Deep Sleep Current
2| Quiescent current, internal RC oscillator disabled| | ISLEEP| | 0.4| µA
3| Quiescent current, internal RC oscillator enabled| | ISLEEP| | 0.7| µA
4| Quiescent current, including 32.768kHz oscillator| | ISLEEP| | 1.0| µA
5| Quiescent current including internal RC oscillator and 32.768kHz
oscillator| | ISLEEP| | 1.3| µA
Reset Current
6 Quiescent current nReset asserted| IRESET| | 1.2| 2.0| mA
Processor and Peripheral Currents
7
8| ARM® CortexTM M3, RAM and flash memory ARM® CortexTM M3, RAM and flash
memory ARM® CortexTM M3,| 25°C, 12MHz
Core clock 25°C, 24MHz
Core clock| IMCU| | 6.0| mA
IMCU| 7.5| mA
9
10| RAM and flash memory sleep current
ARM® CortexTM M3, RAM and flash memory sleep current| 25°C, 12MHz Core clock
25°C, 6MHz Core clock| IMCU| | 3.0| mA
IMCU| 2.0| mA
11| Serial controller current| Per serial controller at max. clock rate| ISC|
| 0.2| mA
12
13| General purpose timer current General purpose ADC| Per timer at max.
clock rate| ITIM| | 0.25| mA
current rate, DMA RX Current| IADC| | 1.1| mA
14| Radio receiver MAC and| ARM® CortexTM| I| | 22| | | mA
Baseband M3 sleeping.
15 Receive current Total, 12MHz| RX
IRX| | 25| mA
16| consumption
Receive current
consumption| clock speed
Total, 24MHz| IRX| | 26.5| mA
| Receive current| clock speed Total, 12MHz| | | |
17| consumption BOOST MODE Receive current| clock speed| IRX| | 27| mA
18| consumption BOOST MODE| Total, 24MHz clock speed| IRX| | 28.5| mA
TX Current
19| Transmit current consumption| at +3dBm module output power| ITXVCC| 31| mA
20| Transmit Current consumption
BOOST MODE| at +8dBm module output power| ITXVCC| 42| mA
21| Transmit current consumption| at +0dBm module output power| ITXVCC| 28.5|
mA
22| Transmit current consumption| at min. module output power| ITXVCC| 23.5|
mA
23| Wake time from deep sleep| From wakeup event to 1st| | 100| µs
24| Shutdown time| From last instruction into deep sleep| | 5| µs
Table 8: DC Electrical Characteristics
Please Note: T he average current consumption during operation is dependent on the firmware and the network load, therefore these figures are provided in the command dictionary of the respective firmware.
Digital I/O Specifications
The digital I/Os of the ETRX35x module
VCC= 3.0V, T AMB = 25°C, NORMAL MODE unless otherwise stated
No. | Item | Condition/Remark | Symbol | Value | Unit |
---|---|---|---|---|---|
Min | Typ | Max | |||
1 | Low Schmitt switching | ||||
threshold | Schmitt input threshold | ||||
going from high to low | V SWIL | 0.42 x | |||
VCC | 0.5 x VCC | Vdc | |||
2 | High Schmitt switching | ||||
threshold | Schmitt input threshold | ||||
going from low to high | V SWIL | 0.62 x | |||
VCC | 0.8 x VCC | MHz | |||
3 | Input current for logic 0 | I IL | |||
4 | Input current for logic 1 | I IH | |||
5 | Input Pull-up resistor value | R IPU | 24 | 29 | |
6 | Input Pull-down resistor value | R IPD | 24 | 29 | |
7 | Output voltage for logic 0 | IOL = 4mA (8mA) for standard (high current) | |||
pads | V OL | 0 | 0.18 x VCC | V | |
8 | Output voltage for logic 1 | I OH = 4mA (8mA) for standard (high current) | |||
pads | V OH | 0.82 x | |||
VCC | VCC | V | |||
9 | Output Source Current | Standard current pad | I OHS | ||
10 | Output Sink current | Standard current pad | I OLS | ||
11 | Output Source Current | High current pad (1) | I OHH | ||
12 | Output Sink current | High current pad (1) | I OLH | ||
13 | Total output current | I OH + I | |||
OL | 40 | mA |
Table 9. Digital I/O Specifications
Notes
- High current pads are PA6, PA7, PB6, PB7, PC0
A/D Converter Characteristics
The ADC is a first-order sigma-delta converter. For additional information on the ADC please refer to section 10 of the EM35x data sheet.
No.| Item|
---|---|---
1| A/D resolution| Up to 14 bits
2| A/D sample time for 7-bit conversion| 5.33µs
3| A/D sample time for 14-bit conversion| 682µs
4| Reference Voltage| 1.2V
5| Max current drain from Vref pin| 1mA
Table 10. A/D Converter Characteristics
AC Electrical Characteristics
VCC = 3.0V, T AMB = 25°C, NORMAL MODE measured at 50Ω terminal load connected to the U.FL socket
No. | Receiver | Value | Unit |
---|---|---|---|
Min | Typ | Max | |
1 | Frequency range | 2400 | |
2 | Sensitivity for 1% Packet Error Rate (PER) | -100 | |
3 | Sensitivity for 1% Packet Error Rate (PER) BOOST MODE | 0 | -102 |
4 | Saturation (maximum input level for correct operation) | ||
5 | High-Side Adjacent Channel Rejection (1% PER and desired signal –82dBm acc. | ||
to [1]) | 41 | ||
6 | Low-Side Adjacent Channel Rejection (1% PER and desired signal –82dBm acc. | ||
to [1]) | 44 | ||
7 | 2nd High-Side Adjacent Channel Rejection (1% PER and desired signal –82dBm | ||
acc. to [1]) | 53 | ||
8 | 2nd Low-Side Adjacent Channel Rejection (1% PER and desired signal –82dBm | ||
acc. to [1]) | 52 | ||
9 | Channel Rejection for all other channels (1% PER and desired signal –82dBm | ||
acc. to [1]) | 40 | ||
10 | 802.11g rejection centred at +12MHz or –13MHz (1% PER and desired signal | ||
–82dBm acc. to [1]) | 36 | ||
11 | Co-channel rejection (1% PER and desired signal –82dBm acc. to [1]) | ||
-6 | dBc | ||
12 | Relative frequency error (2x40ppm required by [1]) | -120 | |
13 | Relative timing error (2x40ppm required by [1]) | -120 | |
14 | Linear RSSI range | 40 | |
15 | Output power at highest power setting NORMAL MODE BOOST MODE | 0 | 3 |
8 | dBm | ||
16 | Output power at lowest power setting | -55 | |
17 | Error vector magnitude as per IEEE802.15.4 | 5 | |
18 | Carrier frequency error | -40 (1) | |
19 | PSD mask relative 3.5MHz distance from carrier | -20 | |
20 | PSD mask absolute 3.5MHz distance from carrier | -30 |
Table 11. AC Electrical Characteristics
Notes
- Applies across the full ranges of rated temperature and supply voltage.
Please Note: For the relationship between EM35x power settings and module output power please relate to chapter 10.1 of this document. When developing custom firmware, the output power settings described in this document relate directly to the EM35x power settings accessible via the Ember stack API.
No. | Synthesizer Characteristics | Limit | Unit |
---|---|---|---|
Min | Typ | Max | |
22 | Frequency range | 2400 | |
23 | Frequency resolution | 11.7 | |
24 | Lock time from off state, with correct VCO DAC settings | ||
25 | Relock time, channel change or Rx/Tx turnaround | ||
26 | Phase noise at 100kHz offset | -75dBc/Hz | |
27 | Phase noise at 1MHz offset | -100dBc/Hz | |
28 | Phase noise at 4MHz offset | -108dBc/Hz | |
29 | Phase noise at 10MHz offset | -114dBc/Hz |
Table 12: Synthesiser Characteristics
No.| Power On Reset (POR) Specifications| Min|
Limit Typ| Max| | Unit
---|---|---|---|---|---|---
30
31
| VCC POR release| 0.62
0.45| 0.95
0.65| 1.2
0.85| Vdc
Vdc|
VCC POR assert
Table 13: Power On Reset Specifications
No.| nRESET Specifications| **| Limit| **| |
Unit
---|---|---|---|---|---|---
| Min| Typ| Max| |
32| Reset Filter Time constant| 2.1| 12| 16| µs|
33| Reset Pulse width to guarantee a reset| 26| | | µs|
34| Reset Pulse width guaranteed not to cause reset| 0| ****| 1| µs|
35| Input pull-up resistor value while the chip is not reset| 24| 29| 34| kΩ|
36| Input pull-up resistor value while the chip is reset| 12| 14.5| 17| kΩ|
Table 14: nReset Specifications
10.1 TX Power Characteristics
The diagrams below show the typical output power and module current in
dependency on module EM35x power setting. Power settings above 3dBm have Boost
Mode enabled. Please note that the output power is independent of the supply
voltage as the radio is supplied by an internally regulated voltage.
Physical Dimensions
Symbol | Explanation | Typical Distance | Tolerances |
---|---|---|---|
L | Length of the module | 25.0mm | ±0.13mm |
W | Width of the module | 19.0mm | ±0.13mm |
H | Height of the module | 3.8mm | ±0.1mm |
A1 | Distance centre of pad PCB edge | 0.9mm | ±0.13mm |
A2 | Pitch | 1.27mm | n/a |
R1 | Keep-out Zone from corner of PCB | 17.5mm | n/a |
R2 | Keep-out Zone from corner of PCB | 4.1mm | n/a |
X1 | Distance centre of Antenna connector PCB edge | 3.8mm | ±0.13mm |
X2 | Distance centre of Antenna connector PCB edge | 2.8mm | ±0.13mm |
Table 15: ETRX3 Physical Dimensions
For ideal RF performance when using the on-board antenna, the antenna should be located at the corner of the carrier PCB. There should be no components, tracks or copper planes in the keep-out area, which should be as large as possible. When using the U.FL RF connector the keep-out area does not have to be obeyed. Note: The modules’ transmit/receive range will depend on the antenna used and also the housing of the finished product.
Module weight: 2.9-3.0g depending on variant
Recommended Soldering Temperature Profile
Use of “No-Clean” solder paste is recommended to avoid the requirement for a
cleaning process.
Cleaning the module is strongly discouraged because it will be difficult to
ensure no cleaning agent and other residuals are remaining underneath the
shielding can as well as in the gap between the module and the host board.
Please Note:
Maximum number of reflow cycles: 2
Opposite-side reflow is prohibited due to the module’s weight. (i.e., you must
not place the module on the bottom / underside of your PCB and re-flow).
Product Package Marking
Imprint | Description |
---|---|
Model: ETRX357/ETRX357HR | Module number designation |
Certification Marks | Certification-related information such as the CE and UKCA |
compliance marks and the FCC and IC IDs, etc., will be engraved on the
hatched-out area or printed on the back side of the module, according to
regulatory body requirements.
QR Code| QR Code containing information in the format YYWWMMABCDE
YY: Last two digits of the assembly year
WW: Two-digit workweek when the device was assembled
MMABCDE: Silicon Labs unit code
YYWWTTTTTT| Serial Number Code in the format YYWWTTTTTT YY: Last two digits of
the assembly year
WW: Two-digit workweek when the device was assembled
TTTTTT: Manufacturing trace code. The first letter is the device revision.
Recommended Footprint
14.1 Pad Dimensions
In order to surface mount an ETRX3 series module, we recommend that you use
pads which are 1mm wide and 1.2mm high. You must retain the keep-out zone
shown in section 12 and ensure that this keep-out area is free of components,
copper tracks and/or copper planes/layers.
You must also ensure that there is no exposed copper on your layout which may
contact with the underside of the ETRX3 series module.
For best RF performance it is required to provide good ground connections to
the ground pads of the module. It is recommended to use multiple vias between
each ground pad and a solid ground plane to minimize inductance in the ground
path.
The land pattern dimensions above serve as a guideline.
We recommend that you use the same pad dimensions for the solder paste screen
as you have for the copper pads. However, these sizes and shapes may need to
be varied depending on your soldering processes and your individual production
standards. We recommend a paste screen thickness of 120μm to 150μm.
Figure 6 shows the typical pad dimensions of the module and Figure 10 – Figure
12 in section 14.2 show examples of how to align the module on its host PCB.
Although the undersides of the ETRX3 series modules are fully coated, no exposed copper, such as uncovered through-hole vias, planes or tracks on your board component layer, should be located below the ETRX3 series module in order to avoid ‘shorts’. All ETRX3 series modules use a multilayer PCB containing an inner RF shielding ground plane, therefore there is no need to have an additional copper plane directly under the ETRX3 series module.
14.2 Recommended Placement
When placing the module please either locate the antenna in the corner as
shown in Figure 10 so that the recommended antenna keep-out zone is being
followed or add a no copper zone as indicated in Figure 12.
14.3 Example Carrier Board
Since the RF performance of the module with the on-board antenna is strongly
dependent on the proper location of the module on its carrier board, Figure 13
shows the reference carrier board which was used during testing by Telegesis.
For best performance it is recommended to locate the antenna towards the
corner of the carrier board and to respect the recommended keep-out areas as
described in section 11.
Finally, to provide a good reference ground to the on board antenna, the
carrier board should have a ground plane spanning no less than 40 x 40mm. In
many cases a smaller ground plane will suffice, but degradation in radio
performance could be the result.
Reliability Tests
The measurements below have been conducted on random samples out of mass production and passed after the module has been exposed to standard room temperature and humidity for 1 hour.
No | Item | Limit | Condition |
---|---|---|---|
1 | Vibration test | Electrical parameter should be in specification |
Freq.:40Hz, Amplitude:1.5mm 20min. / cycle,1hrs. each of X and Y axis
2| Shock test| the same as the above| Dropped onto hard wood from height of
50cm for 3 times
3| Heat cycle test| the same as the above| -40°C for 30min. and +85°C for
30min.; each temperature 300 cycles
4| Moisture test| the same as the above| +60°C, 90% RH, 300h
5| Low temp. test| the same as the above| -40°C, 300h
6| High temp. test| the same as the above| +85°C, 300h
Application Notes
16.1 Safety Precautions
These specifications are intended to preserve the quality assurance of
products as individual components.
Before use, check and evaluate the module’s operation when mounted on your
products. Abide by these specifications when using the products. These
products may short-circuit. If electrical shocks, smoke, fire, and/or
accidents involving human life are anticipated when a short circuit occurs,
then provide the following failsafe functions as a minimum:
- Ensure the safety of the whole system by installing a protection circuit and a protection device.
- Ensure the safety of the whole system by installing a redundant circuit or another system to prevent a single fault causing an unsafe status.
16.2 Design Engineering Notes
-
Heat is the major cause of shortening the life of the modules. Avoid assembly and use of the target equipment in conditions where the product’s temperature may exceed the maximum allowable.
-
Failure to do so may result in degrading of the product’s functions and damage to the product.
-
If pulses or other transient loads (a large load applied in a short time) are applied to the products, before use, check and evaluate their operation when assembled onto your products.
-
These products are not intended for other uses, other than under the special conditions shown below. Before using these products under such special conditions, check their performance and reliability under the said special conditions carefully, to determine whether or not they can be used in such a manner.
-
In liquid, such as water, salt water, oil, alkali, or organic solvent, or in places where liquid may splash.
-
In direct sunlight, outdoors, or in a dusty environment
-
In an environment where condensation occurs.
-
In an environment with a high concentration of harmful gas (e.g., salty air, HCl, Cl2, SO2, H2S, NH3, and NOx)
-
If an abnormal voltage is applied due to a problem occurring in other components or circuits, replace these products with new products because they may not be able to provide normal performance even if their electronic characteristics and appearances
appear satisfactory. -
Mechanical stress during assembly of the board and operation has to be avoided.
-
Pressing on parts of the metal cover or fastening objects to the metal cover is not permitted.
16.3 Storage Conditions
- The module must not be stressed mechanically during storage.
- Do not store these products in the following conditions or the performance characteristics of the product, such as RF performance, may well be adversely affected:
- Storage in salty air or in an environment with a high concentration of corrosive gas, such as Cl2, H2S, NH3, SO2, or NOX
- Storage in direct sunlight
- Storage in an environment where the temperature may be outside the range of 5°C to 35°C range, or where the humidity may be outside the 45 to 85% range.
- Storage (before assembly of the end product) of the modules for more than one year after the date of delivery at your company even if all the above conditions (1) to (3) have been met, should be avoided.
Packaging
17.1 Embossed Tape
- Dimensions of the tape
- Cover tape peel force
- Empty pockets
NB: Empty pockets in the populated area will be less than two per reel
and those empty pockets will not be consecutive.
17.2 Component Orientation
Top cover tape will not obstruct the carrier tape holes and will not extend
beyond the edges of the carrier tape
17.3 Reel Dimensions
(4) Quantity per reel: 600 pieces
(5) Marking: Part No. / Quantity / Lot No. and manufacturer part# with bar-
code will be on the reel
17.4 Packaging – bag
(6) Each reel will be packed in a hermetically sealed bag containing desiccant
and a humidity indicator card
(7) Marking: Part No. / Quantity / Lot No. and manufacturer part# with bar-
code
17.5 Packaging – carton
(8) Each reel and bag will be placed in a cardboard carton of nominal
dimensions 343 x 338 x 68 mm.
(9) Weight of carton containing reel of 600 modules: 2.51kg approx.
Ordering Information
Ordering/Product Code 1, 2 | Description |
---|
ETRX351 3
ETRX357| Telegesis Wireless Mesh Networking Module with Ember Zigbee
Technology:
• Based on Ember EM351 or EM357
• Telegesis AT Style Command Interpreter based on
• EmberZNet meshing and self-healing Zigbee PRO stack
• Integrated 2.4GHz Antenna
ETRX351HR3
ETRX357HR| Telegesis Wireless Mesh Networking Module with Ember Zigbee
Technology:
• Based on Ember EM351 or EM357
• Telegesis AT Style Command Interpreter based on
• EmberZNet meshing and self-healing Zigbee PRO stack
• U.FL coaxial Antenna Connector
ETRX3DVK3| Telegesis Development Kit with:
• 3 x ETRX35xDV Development Boards
• 3 x USB cables
• 2 x ETRX35x on carrier boards
• 2 x ETRX35xHR on carrier boards
• 2 x ETRX35x-LR on carrier boards
• 2 x ETRX35xHR-LR on carrier boards
• 1 x ETRX2USB USB stick
• 2 x ½-wave antennae
• 2 x ¼-wave antennae
Notes:
- Customers’ PO’s must state the Ordering/Product Code.
- There is no “blank” version of the ETRX35x modules available. All Modules are pre- programmed with the Telegesis AT style command interpreter based on the EmberZNet stack. (In case it is desired to program custom firmware the pre-programmed firmware can simply be overwritten).
- This part is End of Life (EOL) and is no longer available.
RoHS Declaration
Declaration of environmental compatibility for supplied products:
Hereby we declare based on the declaration of our suppliers that this product
does not contain any of the substances which are banned by Directive
2011/65/EU (RoHS2) or if they do, contain a maximum concentration of 0,1% by
weight in homogeneous materials for:
- Lead and lead compounds
- Mercury and mercury compounds
- Chromium (VI)
- PBB (polybrominated biphenyl) category
- PBDE (polybrominated biphenyl ether) category
And a maximum concentration of 0.01% by weight in homogeneous materials for:
- Cadmium and cadmium compounds
Data Sheet Status
Telegesis (UK) Ltd. reserves the right to change the specification without notice, in order to improve the design and supply the best possible product. Please consult the most recently issued data sheet before initiating or completing a design.
21 Related Documents
- IEEE Standard 802.15.4 –2003 Wireless Medium Access Control (MAC) and Physical Layer (PHY) Specifications for Low-Rate Wireless Personal Area Networks (LR-WPANs)
- Data sheet EM35x, Silicon Labs. (www.silabs.com)
- Data sheet U.FL-Series 2004.2 Hirose Ultra Small Surface Mount Coaxial Connectors – Low Profile 1.9mm or 2.4mm Mated Height
- The Zigbee specification (www.zigbee.org)
- Specification for Antenova Rufa Antenna (www.antenova.com)
- Embedded Antenna design Ltd. (EAD Ltd.) (www.ead-ltd.com)
- Wellhope Communication Equipment (www.wellhope-wireless.com
©2022 Silicon Labs
ETRX35x Product Manual (Rev 1.22)
Downloaded from Arrow.com.
References
- Antennas for GNSS, 5G, Bluetooth and Wi-Fi | Antenova
- Welcome to Embedded Antenna Design Ltd - EAD
- Silicon Labs
- Wireless and RF Solutions - IoT Modules and SoCs - Silicon Labs
- CSA-IOT - Connectivity Standards Alliance
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>