Allied 4SHP17LE High Efficiency Split System Heat Pump Instructions
- June 16, 2024
- Allied
Table of Contents
Allied 4SHP17LE High Efficiency Split System Heat Pump
Product Specifications
- Model: 4SHP17LE
- Product Type: High Efficiency Split System Heat Pump
- SEER (Seasonal Energy Efficiency Ratio): Up to 18.2 SEER
- HSPF (Heating Seasonal Performance Factor): Up to 10.6 HSPF
- Compressor Overload Conditions
- Cabinet Design
- Coils
- Form No.: 4SHP17LE-100 (09/2022)
- Components
- Compressor Warranty: 10 years of limited warranty coverage (5-year limited parts warranty plus an additional 5-year limited extended parts warranty). Must be registered online within 60 days of installation to qualify for 10-year coverage. Unregistered equipment defaults to 5-year coverage. See full warranty at www.alliedair.com for terms, conditions, and exclusions.
Model Number Guide
The model number guide provides information about the specific configuration of the product:
- Refrigerant: R410A
- Product Type: Split Heat Pump
- SEER: 17
- Tier: Louvered Enhanced
- Major Revision Code
- Minor Revision Code
- Electrical: 1-Phase, 208/240V, 60Hz
- Tonnage: 18, 24, 30, 36, 42, 48, 60
- Region Restrictions: All Regions
Physical and Electrical Data
Model| Voltage/Hz/Phase| Voltage Range| Min. Circuit Amp.| Max. Over Current
Device (amps)| Compressor Rated Load (amps)| Compressor Locked Rotor (amps)|
Outdoor Fan Motor Full Load Rated Nom. (amps)| Outdoor Fan Motor HP| Outdoor
Fan Motor RPM
---|---|---|---|---|---|---|---|---|---
4SHP17LE118P-51| 208-230/60/1| 197-253| 13.6| 20| 10.3| 45.7| 0.7| 1/8| 825
Unit Dimensions
Model | A Width (inch) | B Depth (inch) | C Height (inch) |
---|---|---|---|
4SHP17LE118P-51 | 29.38 | 31.25 | 43.75 |
Unit Sound Ratings
Model | Sound Power1 | Estimated Sound Pressure (dBA)2 | Approximate Distance3 |
---|---|---|---|
4SHP17LE118P-51 | 72 | 64 | 3.3 Feet (1 Meter) |
Refrigeration Data
Model| Refrig. Charge (Oz.)*| TXV| Refrigerant Line Size Suction| Refrigerant
Line Size Liquid
---|---|---|---|---
4SHP17LE118P-51| 98| H4TXV01| 3/4| 3/8
Product Usage Instructions
Installation
Follow the steps below to install the product:
- Choose a suitable location for the unit.
- Ensure proper electrical connections.
- Connect the refrigerant lines.
- Install the outdoor fan motor.
- Secure the cabinet in place.
- Complete any additional installation steps specified in the user manual.
Operation
To operate the product, follow these instructions:
- Turn on the electrical power supply.
- Set the desired temperature using the control panel.
- The unit will start heating or cooling as needed to reach the set temperature.
- Monitor the unit for any unusual sounds or behaviors.
Maintenance
Regular maintenance is required to ensure optimal performance of the
product. Follow these maintenance guidelines:
- Clean or replace the air filters regularly.
- Check for any debris or obstructions around the outdoor unit and remove them if necessary.
- Schedule professional maintenance at least once a year to inspect and service the unit.
FAQ
Q: How long is the warranty coverage for the compressor?
A: The compressor is covered by a total of 10 years of limited warranty
coverage. This includes a standard 5-year limited parts warranty and an
additional 5-year limited extended parts warranty.
To qualify for the 10-year coverage, the warranty must be registered online
within 60 days of installation. Unregistered
equipment defaults to 5-year coverage.
Q: Where can I find the latest AHRI system matches?
A: For the latest AHRI system matches, please visit either
www.alliedratings.com or
www.AHRIdirectory.org.
HIGH EFFICIENCY
SPLIT SYSTEM HEAT PUMP
UP TO 18.2 SEER & 10.6 HSPF
UP TO 16.8 SEER2 & 8.5 HSPF2
FORM
COMPRESSOR
- High-efficiency scroll compressor
- R410A refrigerant
- Grommet mounted compressor for quiet operation
- Heavy-duty compressor sound blanket for quiet operation
- Internally protected against high temperature motor overload conditions
CABINET
- Full metal louvered panel with 2 screws to remove for ease of coil cleaning and service
- Corner-mounted controls for easy service
- Rounded corners for safety and attractive, clean appearance
- Baked polyester paint finished over galvanized steel for maximum durability
- Removable PVC coated wire fan discharge grill
- 45-degree offset gauge ports for easy service
- Removable service panel for internal access
COILS
-
Omniguard® total corrosion protection technology
-
Enhanced tube-and-fin coil design featuring MHT™
Technology provides maximum heat transfer -
Factory tested for leak-proof construction
-
Raised coil prevents debris from impeding airflow
COMPRESSOR
- High-efficiency scroll compressor
- R410A refrigerant
- Grommet mounted compressor for quiet operation
- Heavy-duty compressor sound blanket for quiet operation
- Internally protected against high temperature motor overload conditions
CABINET
- Full metal louvered panel with 2 screws to remove for ease of coil cleaning and service
- Corner-mounted controls for easy service
- Rounded corners for safety and attractive, clean appearance
- Baked polyester paint finished over galvanized steel for maximum durability
- Removable PVC coated wire fan discharge grill
- 45-degree offset gauge ports for easy service
- Removable service panel for internal access
COILS
-
Omniguard® total corrosion protection technology
-
Enhanced tube-and-fin coil design featuring MHT™
Technology provides maximum heat transfer -
Factory tested for leak-proof construction
-
Raised coil prevents debris from impeding airflow
NOTE:
For the latest AHRI system matches, please visit
www.alliedratings.com or
www.AHRIdirectory.org
MODEL NUMBER GUIDE
PHYSICAL AND ELECTRICAL DATA
Model
| ****
Voltage/Hz/ Phase
| ****
Voltage Range
| ****
Min. Circuit Amp.
| Max. Over Current Device (amps)| Compressor| Outdoor Fan Motor
---|---|---|---|---|---|---
Rated Load (amps)| Locked Rotor (amps)| Full Load (amps)| Rated HP| Nom. RPM
4SHP17LE118P-51| 208-230/60/1| 197-253| 13.6| 20| 10.3| 45.7| 0.7| 1/8| 825
4SHP17LE124P-51| 208-230/60/1| 197-253| 15.1| 25| 11.5| 59.5| 0.7| 1/8| 825
4SHP17LE130P-51| 208-230/60/1| 197-253| 15.6| 25| 11.7| 71.3| 1.0| 1/6| 825
4SHP17LE136P-51| 208-230/60/1| 197-253| 17.8| 30| 13.1| 83.1| 1.4| 1/5| 825
4SHP17LE142P-51| 208-230/60/1| 197-253| 25.9| 40| 18.6| 110.0| 2.6| 1/3| 825
4SHP17LE148P-51| 208-230/60/1| 197-253| 33.9| 50| 25.0| 120.0| 2.6| 1/3| 825
4SHP17LE160P-51| 208-230/60/1| 197-253| 32.5| 50| 23.9| 124.5| 2.6| 1/3| 825
UNIT DIMENSIONS (IN.)
Model
| Dimensions (inch)| ****
Shipping Weight (lbs.)
---|---|---
A –
Width
| B –
Depth
| C –
Height
4SHP17LE118P-51| 29.38| 31.25| 43.75| 203
4SHP17LE124P-51| 29.38| 31.25| 43.75| 203
4SHP17LE130P-51| 29.38| 31.25| 33.25| 205
4SHP17LE136P-51| 35.75| 37.75| 33.25| 230
4SHP17LE142P-51| 35.75| 37.75| 37.75| 284
4SHP17LE148P-51| 35.75| 37.75| 37.75| 284
4SHP17LE160P-51| 35.75| 37.75| 43.75| 298
Dimensions listed are unit sizes w/o packaging Weights listed are unit weights with packaging
UNIT SOUND RATINGS
Model
| ****
Sound Power1
| Estimated Sound Pressure (dBA)2
---|---|---
Approximate Distance3
3.3 Feet (1 Meter)| 6.6 Feet (2 Meters)| 9.8 Feet (3 Meters)
4SHP17LE118P-51| 72| 64| 58| 54
4SHP17LE124P-51| 71| 63| 57| 53
4SHP17LE130P-51| 76| 68| 62| 58
4SHP17LE136P-51| 75| 67| 61| 57
4SHP17LE142P-51| 73| 65| 59| 55
4SHP17LE148P-51| 73| 65| 59| 55
4SHP17LE160P-51| 73| 65| 59| 55
- Rated in accordance with AHRI standard 270 (2015)
- Rated in accordance with AHRI standard 275 (2010)
- Based only on distance factor; other factors may change this value such as:
- Unit location (reflective surfaces adjacent to the unit)
- Barrier shielding sources
- Sound path/elevation
- Outside noise sources
REFRIGERATION DATA
Model
| Refrig. Charge (Oz.)*| ****
TXV
| Refrigerant Line Size| Outdoor Unit Connection| Indoor Unit Connection
---|---|---|---|---|---
Suction| Liquid| Suction| Liquid| Suction| Liquid
4SHP17LE118P-51| 98| H4TXV01| 3/4| 3/8| 3/4| 3/8| 3/4| 3/8
4SHP17LE124P-51| 96| H4TXV01| 3/4| 3/8| 3/4| 3/8| 3/4| 3/8
4SHP17LE130P-51| 117| H4TXV01| 3/4| 3/8| 3/4| 3/8| 3/4| 3/8
4SHP17LE136P-51| 137| H4TXV02| 7/8| 3/8| 7/8| 3/8| 7/8| 3/8
4SHP17LE142P-51| 162| H4TXV02| 7/8| 3/8| 7/8| 3/8| 7/8| 3/8
4SHP17LE148P-51| 146| H4TXV02| 7/8| 3/8| 7/8| 3/8| 7/8| 3/8
4SHP17LE160P-51| 164| H4TXV03| 1-1/8| 3/8| 1-1/8| 3/8| 1-1/8| 3/8
Factory charged for 15 feet of line set; adjust per installation instructions.
Reducer fitting supplied with OD unit
COOLING PERFORMANCE WITH AIR HANDLERS AND FURNACES
Outdoor Model
| Indoor Model| Cooling| Heating
---|---|---|---
Evap. Coil or Air Handler3
| ****
SEER
| ****
SEER2
| ****
EER
| ****
EER2
| AHRI
Rated Capacity1
| ****
Sensible Capacity
| ****
HSPF
| ****
HSPF2
| 47°| 17°
Btuh| COP| Btuh| COP
4SHP17LE118P-51| BCE5C18M4X| 15.5| 15.2| 13.0| 13.0| 18,000| 14,400| 9.2|
8.0| 17,900| 3.80| 11,200| 2.54
4SHP17LE124P-51| BCE5C24M4X| 15.5| 14.7| 13.0| 12.4| 23,200| 17,800| 9.6|
8.0| 22,200| 3.72| 14,000| 2.54
4SHP17LE130P-51| BCE5C30M4X| 15.0| 14.4| 12.2| 12.0| 28,400| 22,400| 9.2|
8.0| 27,800| 3.56| 18,000| 2.52
4SHP17LE136P-51| BCE5C36M4X| 15.5| 14.7| 12.5| 12.4| 35,600| 27,000| 9.6|
8.0| 34,000| 3.62| 22,400| 2.56
4SHP17LE142P-51| BCE5C42M4X| 15.0| 14.4| 12.2| 12.0| 40,500| 30,800| 9.2|
7.8| 39,000| 3.40| 25,000| 2.46
4SHP17LE148P-51| BCE5C48M4X| 15.4| 14.7| 12.5| 12.4| 47,000| 35,400| 9.8|
8.2| 46,500| 3.64| 30,400| 2.64
4SHP17LE160P-51| BCE5C60M*4X| 15.1| 14.3| 12.5| 11.7| 56,500| 41,500| 9.6|
8.0| 54,000| 3.50| 35,000| 2.56
Note:
- Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240
- Required to achieve AHRI rating. If NA (not applicable) is in the piston column then TXV is required.
- Blower time delay relay is standard on all Allied Air Enterprises furnace and AH products.
ACCESSORIES
System Accessory | Where Used | Kit Number | Purpose |
---|---|---|---|
Liquid Line Solenoid | All models | 60M52 | Prevents liquid migration to the |
compressor especially for high liquid riser applications
Low Ambient (cooling operation)| All models| 54M89| Enables cooling demand
down to 30 °F. Will require freeze stat, CC heater and TXV
Mild Ambient (heating operation)| All models| 11B97| Enables heating demand
above 60 °F ambient
Cold Weather| All models| 1.921145| To allow unit to operate at very low
ambient conditions (older models). Board integrated feature on new models
Fossil Fuel Kit (Heat Pump Only)| All models| 1.841185 (AFOSL500)| Required
for furnace with heat pump installations
Hard Start
| 24 & 36| 10J42| Scroll compressors usually do not require hard start; maybe
needed for utility brown-out or low voltage areas
48 & 60| 81J69
Crankcase Heater
| 18, 24, 30| 93M04| ****
Prevents liquid migration to compressor in cold weather
36, 42, 48, 60| Factory Installed
Sound Cover| Factory Installed| Lowers compressor sound level
Loss of Charge Kit| Factory Installed| Protects the compressor if refrigerant
charge is too low
Additional System Accessories (indoor section)
TXV Kit
| 18, 24, 30| H4TXV01| ****
TXVs provide superior refrigerant flow control, comfort and efficiency compared to pistons
36, 42, 48| H4TXV02
60| H4TXV03
Outdoor Thermostat – Electric Heat| All models| 10Z23 (56A87)| Prevents
electric heat operation above specific ambient conditions
Outdoor Thermostat – Mounting Box| All models| 31461| Mounting box for outdoor
thermostat
Freezestat| All models| 93G35| Protects the compressor at low suction pressure
conditions
Overflow Switch| All models| 11U75| Turn the system off, if condensate water
overflows due to clogged drain pipes
Single Point Power Supply| All models| 21H39| Provide single power source in
one junction box
Auxiliary Blower Relay| All models| 85W66| Maybe required to select multiple
indoor blower speeds
All specifications and illustrations subject to change without notice and without incurring obligations.
Form No. 4SHP17LE-100 (09/2022) ©2022 Allied Air Enterprises LLC, a Lennox International Inc. Company Printed in the U.S.A.