Product Information
Specifications
- Product Model: iLOQ S50 (Y50S.T.TL01, Y50S.T.TL02)
- Platform: 5 Series
- Type: Battery-free programmable NFC cylinders
- Lazy Tailpiece Angle for Y50S.T.TL01: 45 degrees
- Lazy Tailpiece Angle for Y50S.T.TL02: Horizontal
Overview
The iLOQ S50 (Y50S.T.TL01, Y50S.T.TL02) is a battery-free programmable NFC cylinder designed for the iLOQ S50 product family in the 5 Series platform. It consists of a front cap, knob, cylinder, plunger, lazy tailpiece, tailpiece spacer, and crown.
Tools supplied
- Knob removal tool
- Cap removal tool
- Crown removal tool (necessary for changing the tailpiece)
Lazy Tailpiece
The lazy tailpiece for the Y50S.T.TL01 has a 45-degree angle and is
compatible with Schlage B560/B660 deadbolts or any other deadbolts with a
similar angle. The lazy tailpiece for the Y50S.T.TL02 is horizontal and can be
used with most standard deadbolts that work with a KIK Schlage cylinder.
Installation
Please read the following instructions carefully before installing the iLOQ
S50 (Y50S.T.TL01, Y50S.T.TL02).
Safety
Ensure your safety and the proper installation of the product by following
these safety guidelines:
- Read the instructions carefully before using the product.
- Be aware of any warning signs indicating potential hazards.
General Notes
Before installing the product, please take note of the following:
- The content of this manual is current at the time of publication. For the most up-to-date information, refer to our website at support.iloq.com.
- Avoid causing any damage to the product during installation.
- The product is designed to be maintenance-free and does not require regular maintenance.
Installation Instructions
Installation of the iLOQ KIK for Deadbolt Cylinder
Follow these steps to install the iLOQ KIK for Deadbolt Cylinder:
-
1. Cut the tailpiece to the proper length according to the door thickness.
- Insert the knob removal tool into the front of the knob to remove the knob from the cylinder. Press firmly and hold the knob securely during installation and removal to prevent the tool from accidentally popping off.
FAQ
-
Q: Is regular maintenance required for the iLOQ S50 (Y50S.T.TL01, Y50S.T.TL02)?
A: No, the product is designed to be maintenance-free and does not require any regular maintenance. -
Q: Where can I find the most up-to-date information about the product?
A: For the most current information, please visit our website at support.iloq.com.
Safety Information
Safety signs
- General notice sign. Indicates particularly important information about the installation or product.
- Read these instructions carefully before using products. This information is to ensure your safety and long lifetime of the products.
- General warning sign. Indicates the presence of a hazard which could result in personal injury, equipment damage, or loss of data.
Overview
iLOQ KIK Schlage for deadbolt cylinder
The iLOQ Y50S.T.TL01 and Y50S.T.TL02 are battery-free programmable NFC
cylinders for the iLOQ S50 product family in the 5 Series platform.
- Front cap
- Knob
- Cylinder
- Plunger
- Lazy tailpiece
- Tailpiece spacer
- Crown
Tools supplied
- Knob removal tool
- Cap removal tool
- Crown removal tool (necessary in case the installer needs to change the tailpiece)
Lazy tailpiece for iLOQ KIK Schlage Cylinder Y50S.T.TL01
The lazy tailpiece for KIK Schlage Cylinder Y50S.T.TL01 has a 45 degrees
angle, and it is used with Schlage B560/B660 deadbolts or with any other
deadbolts that have a bolt with a similar 45 degrees angle.
Lazy tailpiece for iLOQ KIK Schlage Cylinder Y50S.T.TL02
The lazy tailpiece for KIK Schlage Cylinder Y50S.T.TL02 is horizontal, and it
is used with most standard deadbolts that work with a KIK Schlage cylinder.
Before installation
The content of this manual is current at the time of publication. iLOQ reserves the right to change availability of any item in this guide, its design, construction, and/or its materials. For the most current information, please see our website at support.iloq.com.
Safety
- WARNING! Choking hazard – this product contains small parts, including small magnets. Avoid disassembling the product. If a child swallows magnets, seek medical help immediately.
- WARNING! This product contains small magnets. Medical devices, such as implanted pacemakers and defibrillators may contain sensors that respond to magnets and radios when in close contact. To avoid any potential interactions with these devices, keep the product in a safe distance away from your device (more than 4 inches/10 cm, but consult with your healthcare provider and your device manufacturer for specific guidelines). Do not place your credit card or any other magnetic stripe cards near this product.
General notes
- Installation
- This product must be installed only by professional personnel who have received a training arranged by or on behalf of iLOQ.
- This product is available with different types of tailpieces. Make sure to select the correct tailpiece according to the door hardware.
- Only use an authentic iLOQ tailpiece. The use a of non-iLOQ tailpiece can compromise the built-in security features.
- If the product is installed on a fire door, examine the fire certification to ensure conformity. If needed, contact an iLOQ sales representative for assistance.
- Make sure that the operation of the product complies with the local building codes, security regulations and any other applicable regulations.
- After installation, make sure that the product operates properly without interference from weatherstripping, or other parts of the door. Make sure that the door opens, closes, and swings freely without interference from any projecting part of the lock assembly.
- IMPORTANT! After installation, these instructions and any maintenance instructions should be passed on by the installer to the user. If there are any deviations from the contents in foreign language versions of the documentation, the English original shall apply in case of doubt.
- Avoid damage
- This product is designed and intended for locking doors. Do not use this product for any other purpose. Using the product for unintended purposes may result in damage, malfunction, or safety hazards.
- Do not modify the product in any way, except in accordance with the modifications described in this guide.
- Do not attempt to bypass the locking feature, tamper with the lock or disassemble it. Doing so will compromise the built-in security and damage the product.
- To avoid damage, handle the product with care and do not force any parts during installation and use. The knob should turn easily and the cylinder should operate smoothly.
- Do not apply any liquid to the product, including water, grease, solvent, or corrosive substance, except as specified in this manual.
- Do not expose this product to excessive heat sources, open flames, or heating devices.
- This product contains small magnets. To prevent the batteries of the Programming Key (P55S.1) and the Key Fob (K55S.1) from draining, please store the product in a separate box away from them.
- After operating the lock, make sure that the knob is rotated back to its normal locked position.
- Terms of Service and Warranty
- The lock cylinder has a 24 month warranty. By purchasing or using the product, you agree to the Terms of Service found at www.iloq.com.
- If you suspect that this product is broken, do not attempt to repair it. Contact iLOQ customer support for professional assistance.
- Care & maintenance
The product is designed to be maintenance-free. It does not require any regular maintenance.
Installation
WARNING! Risk of injury. Do not leave the knob removal tool inside the knob. Hold the knob securely during installation and removal to prevent the tool from accidentally popping off.
Installation of the iLOQ KIK for Deadbolt Cylinder
-
Cut the tailpiece to the proper length according to the door thickness.
-
Insert the knob removal tool into the front of the knob to remove the knob from the cylinder. Press firmly on the tool until it clicks while holding the back of the knob.
-
Pull the knob from the cylinder.
-
Remove the tool from the knob.
-
Slide the KIK cylinder into the deadbolt body.
NOTE! An iLOQ high guard escutcheon for Schlage deadbolt B560/ B660 could be used to provide an extra protection to the knob. Remove the Schlage B560/B660 trim ring and replace it with the iLOQ high guard escutcheon (Product code: AX50.Y.ES1.XX). -
Insert the knob removal tool into the front of the knob. While holding the back of the knob, press firmly on the tool until it clicks.
-
While pressing on the tool, slide the knob onto the cylinder until it stops.
NOTE! Make sure that the knob is inserted the correct way around so that the straight edges of the cylinder and knob align horizontally. -
Remove the tool from the knob.
-
Insert the front cap into the knob by aligning the four tabs of the cap with the four pockets in the knob. The iLOQ logo on the cap should be horizontal when the cylinder is locked.
NOTE! The front cap can be installed in four different orientations (0º, 90º, 180º and 270º angles) based on the orientation of the lock.
NOTE! When inserting the KIK Schlage Cylinder Y50S.T.TL02 Cylinder into the deadbolt’s bolt, please ensure the following:- The deadbolt’s bolt is retracted inside the door (open position).
- The tailpiece is in the horizontal position.
- The tailpiece flange is facing down.
Operating instructions
Read and follow the instructions in this manual and any other instructions provided by iLOQ. Failure to do so may result in injury, malfunction, damage or a safety hazard..
WARNING! This product contains small magnets:
- Medical devices, such as implanted pacemakers and defibrillators may contain sensors that respond to magnets and radios when in close contact. To avoid any potential interactions with these devices, keep the product in a safe distance away from your device (more than 4 inches/10 cm, but consult with your healthcare provider and your device manufacturer for specific guidelines)
- Do not place your credit card or any other magnetic stripe cards near this product.
NOTE! Do not use excessive force when operating the lock (Max. 5 Nm of torque).
-
Hold a valid key against the knob and wait until the key shows a green light.
NOTE! Due to the large variety of phone models and operating system versions, iLOQ cannot guarantee that all NFCenabled phones will work seamlessly with our NFC locks.
NOTE! Before using the locks, check where the NFC antenna is located in your phone so that you know the best position to hold the phone against the knob. -
Turn the knob to unlock or lock the door.
-
Make sure that the knob is in the original locked position and cannot be rotated before leaving the door.
Installing the ADA Adapter
- Parts needed:
- AX50.G.KT.3 – Cap removal tool
- AX50.G.KT.1 – ADA Adapter for TorQ Knob:
- ADA Adapter for TorQ Knob
- Knob removal tool
WARNING! Risk of injury. Do not leave the knob removal tool inside the knob. Hold the knob securely during installation and removal to prevent the tool from accidentally popping off.
-
Insert the cap removal tool into the hole of the cap to remove the front cap from the knob.
-
Insert the knob removal tool into the front of the knob. While holding the back of the knob, press firmly on the tool until it clicks.
-
Pull the knob from the cylinder.
-
Remove the tool from the knob.
-
Bring the ADA Adapter around the knob.
NOTE! The screw side should be facing the door and the upper lip of the adapter should sit on top of the upper lip of the knob
NOTE! The ADA adapter can be installed in four different orientations (0º, 90º, 180º and 270º angles). -
Close the ADA-adapter.
-
Tighten the T6 fixing screw on the bottom of the adapter (Max 0.1 Nm of torque).
-
Insert the knob removal tool into the front of the knob. While holding the back of the knob, press firmly on the tool until it clicks.
-
While pressing on the tool, slide the knob onto the cylinder until it stops.
NOTE! Make sure that the knob is inserted the correct way around so that the straight edges of the cylinder and knob align horizontally. -
Remove the tool from the knob.
-
Insert the front cap into the knob by aligning the four tabs of the cap with the four pockets in the knob. The iLOQ logo on the cap should be horizontal when the cylinder is locked.
NOTE! The front cap can be installed in four different orientations (0º, 90º, 180º and 270º angles) based on the orientation of the lock.
Changing the tailpiece of a KIK cylinder
NOTE! Only use an authentic iLOQ tailpiece. The use a of non-iLOQ tailpiece can compromise the built-in security features.
- Parts needed:
- AX50.Y.G.02 – Crown installation tool
- AX50.Y.TX – KIK Tailpiece (specify the needed tailpiece when ordering)
- Remove the KIK cylinder plunger using tweezers.
- Insert the crown installation tool into the crown piece of the KIK cylinder and turn it counterclockwise.
- Remove the tailpiece from the cylinder.
- Push the plunger back into its designated position.
- Insert the new tailpiece and place the spacer in its position.
- Place the crown in its position.
- Insert the crown installation tool and turn it clockwise until it bottoms out.
- Turn the crown installation tool slightly counterclockwise until it stops.
Replacing the knob
If necessary, use the following instructions to replace the knob.
- Parts needed:
- AX50.G.KT – TorQ Knob Without Cap
- AX50.G.KT.A.1 – Black Flat Cap for TorQ Knob
- AX50.G.KT.3 – Cap removal tool
- AX50.G.KT.2 – Knob removal tool
WARNING! Risk of injury. Do not leave the knob removal tool inside the knob. Hold the knob securely during installation and removal to prevent the tool from accidentally popping off.
-
Insert the cap removal tool into the hole of the cap to remove the front cap from the knob.
-
Insert the knob removal tool into the front of the knob. While holding the back of the knob, press firmly on the tool until it clicks.
-
Pull the knob from the cylinder.
-
Insert the knob removal tool into the front of the new knob. While holding the back of the knob, press firmly on the tool until it clicks.
-
While pressing on the tool, slide the knob onto the cylinder until it stops.
NOTE! Make sure that the knob is inserted the correct way around so that the straight edges of the cylinder and knob align horizontally. -
Remove the tool from the knob.
-
Insert the front cap into the knob by aligning the four tabs of the cap with the four pockets in the knob. The iLOQ logo on the cap should be horizontal when the cylinder is locked.
NOTE! The front cap can be installed in four different orientations (0º, 90º, 180º and 270º angles) based on the orientation of the lock.
Converting a KIK Schlage Cylinder to a Mortise Cylinder
- Parts needed:
AX50.X.G.03.26 – 1 1/8” Mortise Conversion Kit (26D)
1. Mortise front frame 26D
2. Adapter plug
3. Mortise housing 1 1/8”
4. T20 Screws (x2)
AX50.X.CXX –
5. Cam for Mortise Cylinder (specify the needed cam when ordering)
AX50.X.G.01 –
6. T6 Screws for cam (x2)
AX50.Y.G.02 –
7. Crown installation tool
AX50.G.KT.3 –
8. Cap removal tool
AX50.G.KT.2 –
9. Knob removal tool
WARNING! Risk of injury. Do not leave the knob removal tool inside the knob. Hold the knob securely during installation and removal to prevent the tool from accidentally popping off.
-
Remove the KIK cylinder plunger using tweezers.
-
Insert the crown installation tool into the crown piece of the KIK cylinder and turn it counterclockwise.
-
Remove the tailpiece from the cylinder.
-
Insert the cap removal tool into the hole of the cap to remove the front cap from the knob.
-
Insert the knob removal tool into the front of the knob to remove the knob from the cylinder. Press firmly on the tool until it clicks while holding the back of the knob.
-
Pull the knob from the cylinder.
-
Remove the tool from the knob.
-
Insert the mortise front frame into the front of the cylinder.
-
Insert the adapter plug and align it with the back of the cylinder.
-
Attach the mortise housing to the front frame and secure it with the two T20 screws.
-
Attach the mortise cam to the cylinder using two T6 screws (max. 0.5 Nm of torque).
-
Insert the knob removal tool into the front of the knob. While holding the back of the knob, press firmly on the tool until it clicks.
-
While pressing on the tool, slide the knob onto the cylinder until it stops.
NOTE! Make sure that the knob is inserted the correct way around so that the straight edges of the cylinder and knob align horizontally. -
Remove the tool from the knob.
-
Insert the front cap into the knob by aligning the four tabs of the cap with the four pockets in the knob. The iLOQ logo on the cap should be horizontal when the cylinder is locked.
NOTE! The front cap can be installed in four different orientations (0º, 90º, 180º and 270º angles) based on the orientation of the lock.
Disposal of decommissioned products
- Never discard an electrical appliance in household waste. Follow the local laws and regulations for safe and environmentally friendly product disposal.
- Before discarding products, bear in mind that most iLOQ products are reusable. All programmable products can be reset to factory settings, after which they can be reused in another system.
Recycling instructions of decommissioned products are depicted below.
Compliance
FCC
Chapter 1, Subpart A, Part 2 of Title 47 of the Code of Federal Regulations
The conformity was assessed in accordance the following standard: FCC – FCC
Rule Part 15
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
ISED
Innovation, Science and Economic Development Canada (ISED) The conformity was
assessed in accordance the following standard: ISED – ICES 003, Issue 7: 2020
– class B