WANLUTECH 510628 Multi Function Tester User Guide
- June 16, 2024
- WANLUTECH
Table of Contents
WANLUTECH 510628 Multi Function Tester
Product Information
Specifications
- Product: WANLUTECH OTDR tester
- Battery: Built-in lithium ion rechargeable battery
- Adaptor: Original adaptor and connected cable
- Measurement Range: Optical fiber attenuation, connector attenuation, fault locator
- Usage: Construction, maintenance, and monitoring of optical fiber
Product Usage Instructions
Section 1: Installing the Battery
- Note: The tester has a built-in lithium-ion rechargeable battery. The battery cable inside the battery cabin should be disconnected for safety during transportation.
- Prior to using the instrument, ensure that the battery cables inside the battery cabin are well connected.
- To power on or off the tester, press the key continuously.
- Always use the original adaptor and connected cable of the device.
- The battery icon will be full or the charge indicator will turn off automatically when the battery charging is complete.
Section 2: OTDR
Summary
OTDR (Optical Time Domain Reflectometer) is an instrument used to understand
the uniformity, defect, fracture, joint coupling, and other properties of
optical fiber through the analysis of the measuring curve. It is used to
measure the attenuation of optical fiber, attenuation of connector, fault
locator, and view the loss distribution along the length of optical fiber.
OTDR is an essential tool in the construction, maintenance, and monitoring of
optical fiber.
Warning
When using OTDR to measure optical fiber, except for 1610nm wavelength
product, working light in the measured optical fiber couldn’t exist.
Otherwise, the instrument will be damaged.
Operation
Fiber Connection
Connect the fiber to the top optical interface of the OTDR using an FC-PC
optical connector.
Auto OTDR Test
The OTDR is set to auto mode by default. Click on OTDR test or select
wavelength, pulse width, and measurement duration in the Quick Setup to start
testing.
Expert OTDR Test
Manually select the range, pulse width, and other parameters for more
accurate test results. Zoom in on the curve tracer and view event map details.
Quick test allows setting laser wavelength, distance range, pulse width, and
measurement duration parameters.
Setting can set laser wavelength, distance range, pulse width, measurement
duration, measurement mode, IOR, non-reflection threshold, and end threshold
parameters. The reflection threshold is the specified item.
Setting
Quick Setup: Can quickly set wavelength, distance range, pulse width, and
measurement duration parameters. If the parameters are not properly set during
testing, they can be quickly changed.
Frequently Asked Questions (FAQ)
Q: Where can I find the After-sales service department?
A: Please contact the After-sales service department at
sales@testerpro.com.cn
Q: What should I do if there is a question or problem while using the OTDR
tester?
A: Please contact our After-sales service department at
sales@testerpro.com.cn
Q: Can I use any adaptor and connected cable for the device?
A: It is recommended to use the original adaptor and connected cable of
the device for optimal performance.
Thank you for purchasing WANLUTECH OTDR tester. Please read the manual before using the OTDR tester and use properly.
For using the OTDR tester safely, please first read the「Safety
Information」carefully in the manual.
The manual should be kept well in case of reference.
Keep the S/N label for after-sale service within warranty period. Product
without S/N label will be charged for repair service.
- If there is any question or problem while using WANLUTECH OTDR CCTV TESTER, or damages occurred on the product, please contact our After-sales service department(sales@testerpro.com.cn)
- The following data is for reference only and no additional notice will be given if there are any changes in the data.
Safe information
-
The tester is intended to use in compliance with the local rules of the electrical usage and avoid to apply at the places which are inapplicable for the use of electrics such as hospital, gas station etc.
-
Please use the original accessories, to avoid damage the tester caused by the use of non-certified accessories
-
The accessories only for our testers, don’t for another usage.
-
To prevent the functional decline or failure, the product should not be sprinkled or damped.
-
The exposed part of the tester should not be touched by the dust and liquid.
-
During transportation and use, it is highly recommended to avoid the violent collision and vibration of the tester, lest damaging components and causing failure.
-
Don’t leave the tester alone while charging and recharging. If the battery is found severely hot, the tester should be powered off from the electric source at once. The tester should not be charged over 10 hours.
-
Don’t connect the living cable or device to the ports of tester when the tester on.
-
Don’t use the tester where the humidity is high. Once the tester is damp, power off immediately and move away other connected cables.
-
The tester should not be used in the environment with the flammable gas.
-
Do not disassemble the instrument since no component inside can be repaired by the user.
If the disassembly is necessary indeed, please contact with the technician of our company. -
The instrument should not be used under the environment with strong electromagnetic interference.
-
Don’t touch the tester with wet hands or waterish things.
-
Don’t use the detergent to clean and the dry cloth is suggested to use. If the dirt is not easy to remove, the soft cloth with water or neutral detergent can be used. But the cloth should be tweaked sufficiently.
Installing the Battery
Note: The tester has built-in lithium ion rechargeable battery. The
battery cable inside battery cabin should be disconnected for safety during
transportation!
Prior to the use of the instrument, the battery cables inside the battery
cabin should be well connected.
Pressing the key continuously can power on or off the tester.
Please use the original adaptor and connected cable of the device!
When the battery icon is full or the charge indicator turns off automatically,
indicate the battery charging is complete
OTDR
Summary
OTDR is an instrument to understand the uniformity, defect, fracture, joint
coupling and other properties of optical fiber through the analysis of the
measuring curve. It is used to measure the attenuation of optical fiber,
attenuation of connector and fault locator, and view the loss distribution
along the length of optical fiber, it is an essential tool in the
construction, maintenance and monitoring of optical fiber.
Warning
- When using OTDR to measure optical fiber, except 1610nm wavelength product, working light in the measured optical fiber couldn’t exist. Otherwise, the measuring result won’t be accurate, and the instrument may be damaged perpetually.
- Don’t look at the optical interface directly or look over the optical interface through optical instrument.
- When the OTDR is working, do not look at the laser outlet directly;
- After using, cover the dust cap onto the optical outlet of the OTDR
- Don’t directly look at the disconnected terminal of the being tested optical fiber. If possible,make the disconnected terminal of fiber optical point to a non-reflective object.
Operation
Connecting fiber Setting parameters Testing Tracer viewing
Fiber connection
Connect the fiber to the top optical interface of OTDR. It adopts FC-PC
optical connector.
Notice: When using OTDR to measure optical fiber, working light in the measured optical fiber couldn’t exist. Or the instrument will be damaged.
Auto OTDR test
Auto OTDR by default, click “OTDR test” or select wavelength, Pulse width and
measurement duration in the “Quick Setup” to start testing. Another parameters
setting as below:
Expert OTDR test
Manually to select the range, pulse width, etc parameters, the test result
will be more accurate.
Can zoom the curve tracer, and view event map details.
Quick test can set laser wavelength, distance range, pulse width and
measurement duration parameters.
Setting can set laser wavelength, distance range, pulse width, measurement
duration,measurement mode, IOR, Non reflection threshold and end threshold
parameters, the reflection threshold is the specified item.
Setting
- Quick Setup
Can quickly set wavelength, distance range, pulse width and measurement duration parameter,if find the parameters are properly on testing, can quickly to change them.
Parameter setting
Laser wavelength: Selected by user, it provides several options, wavelength of
single mode fiber:
1310nm, 1550nm and 1610nm; users can simultaneously select 2 wavelengths at
most to measure, and set analysis and file saving with different wavelength.
In addition, multi wavelength measurement is valid only under the average
measurement mode. Multi wavelength measurement is forbidden under the real-
time measurement mode. (If the fiber over 100KM,Please select 1550nm
wavelength for testing)
- Distance scope: Selected by user, options include “auto, 500m, 1Km, 2Km,5Km,10Km,25Km,50Km, 100Km and 200Km”. If the length is uncertain, it is recommended to use automatic range, for known length, it is recommended to use a range containing 1.5 times the minimum length. Measurement duration: 5s, 10s, 15s, 30s, 60s, 120s, 180s is optional, If the current measurement model is real-time measurement, the selected duration of measurement won’tplay role in the measurement. When need the meticulous and smooth curve, can select the longer measurement time.
- Pulse width: Selected by user, options include “auto, 5ns, 10ns, 20ns, 30ns, 50ns, 80ns, 160ns,300ns, 500ns, 800ns, 1000ns, 2000ns, 4000ns, 6000ns,10000ns, 20000ns”.
- Measurement mode: Selected by user, options include “average measurement and real-time measurement”. When selected real-time measurement mode, the selected duration of measurement won’t play role in the measurement.
- Refractivity: Set by user, the default value is 1.4685. The refractivity is key parameter for calculating the length, please don’t modify it at will.
- Unit: Set by user, options include “m and ft”Reflection threshold: No option or user setting is provided in OTDR instrument.
- Non-reflection threshold: Set by user, input scope: 0.01~2.99, the default value is: auto. When the manual setting value is 0.00, it will transfer to auto value.
- End threshold: It is used as the threshold value for looking over event point when the instrument treating data, i.e.: event points that lower than the set value of end threshold will be removed,while the event points that higher than the set value of bundling threshold will be displayed. For options set by user, input scope is: 1~19.99dB, the default value is: 5.00dB.
- Optical warning of optical fiber: Options include “ON and OFF”, When in ON, if the optical fiber has optical signal, the instrument will pop up alarm.
- Default setting recovery: Distance scope is “auto”, pulse width is “auto”, duration of measurement is “5 s”, laser wavelength is “1550nm”, measurement mode is “average mode”, length unit is “meter”, refractivity is “1.4685”, back scattering coefficient is “auto”, reflection threshold is “auto”, non-reflection threshold is “auto”, end threshold is “5.0dB”, When finished setting, please click “Save” to save the parameters.
Threshold setting
In Event map, can set loss and link attenuation parameters of fusion and
connect point event, If less than reference value, then judge as PASS,
otherwise, will judge as Failed.
If not select the parameter, then will not judge.
Total loss: The total loss value of fiber link. Input scope: 0-60, If less
reference value, then judge as PASS, otherwise, will judge as Failed.
Reflection loss (connect point): The loss value of connector. Input scope:
0-60, If less reference
value, then judge as PASS, otherwise, will judge as Failed.
Non reflection loss (fusion point): The loss value of Fusion point or bend
point fiber. Input scope: 0-60, If less reference value, then judge as PASS,
otherwise, will judge as Failed.
Link attenuation coefficient: Different wavelength of fiber, the attenuation
coefficient is different. Input scope: 0-60, If less reference value, then
judge as PASS, otherwise, will judge as Failed.
File setting
- Auto naming: Options include “Open and Close”. When the auto naming status is “ON”, the auto naming category is optional. When the auto naming status is “OFF”, the auto naming function is off.
- File format: Set by user, options include “otdr and sor”format.
- Name type: Optional automatic naming of wavelength, pulse width, date, range, comment, etc.
It will take effect when automatic naming is turned on.
Note: It is used for edit the content of name type.
Curve tracer
When setting and saved the parameters, click “Start” to start the testing, the
wavelength/distance range/pulse width/duration of measurement/refractivity
will display at the top of interface, when finished the testing, will create
the trace. Click the “Stop” to end the testing.
Definition of trace: After the first measurement, reflection power diagram is
displayed as distance function, the diagram is called trace.
Trace displays the measurement result by graphic mode on the screen. The
vertical axis represents the power, while the lateral axis represents the
distance. The event point is marked with red symbol.
- Trace area
- Trace operation button area
- Information area
- Menu button area
Instruction of Events Categories
Events on optical fiber indicate these abnormal points that brought loss or
sudden change of reflection power beyond normal scattering of optical fiber
material, including various kinds of connection and bending, loss of flaw or
fracture on the optical fiber link.
Event points displayed on the screen is the abnormal points in the optical
fiber that led to deviation of trace, which are classified with special
symbols on the trace.
Events include “reflection event” and “non-reflection event”.
Initial Event
“Initial event” on the OTDR trace is the event that marks the starting point
of optical fiber. Under default conditions, “initial event” is located at the
first event (usually be the first connector of OTDR) of the tested optical
fiber. The event belongs to reflection event.
End Event
“End event” on the OTDR trace is the event that marks the terminal of optical
fiber. Under default conditions, “end event” is located at the last event of
the tested optical fiber. The event is called optical fiber terminal event
(usually be the end or fracture point of the tested optical fiber), which
usually belongs to reflection event.
Reflection Event
When optical pulse energy is reflected (such as on the connector), reflection
event occurs. On the trace, reflection event is shown as peak signal, as shown
in the picture.
Non-reflection event brings loss on the whole transmission link of optical fiber, but no light reflection. On the curve, non-reflection event is shown as drop of optical power, as shown in follow picture.
Event Inspection
OTDR sends optical pulse into the optical fiber that waited for inspection,
then, begins to accept the returned optical signal immediately, and calculate
the distance of “event” in the optical fiber.
The further the event is, the longer the time for returning back to OTDR will
be. The distance can be calculated according to the time when receiving the
event. Through inspecting the curve of the reflected signal, the optical
transmission characteristics of optical fiber, connector and joint can be
confirmed.
Instruction of Info Window Area of the Main Interface
Contents of info window include measurement parameter, event list, scale plate A/B, and analyzed parameter, etc.
Data displayed in the event list include: serial number, category, position,
plug-in loss, Nattenuation coefficient, echo loss, and accumulate loss.
“Serial number” indicates the Ninformation of the nth event that currently
displayed on the trace graph; “Category” indicates the event category of the
event point; “Position” indicates the distance from the initial point of the
optical fiber to the event point; “Plug-in loss” indicates the quantity of
plug-in loss of the event; “Attenuation coefficient” indicates the attenuation
characteristics of the optical fiberN from the last event point to the current
event point; “Echo loss” reflect the reflection value of Nthe event point;
“Accumulate loss” indicates the loss value of optical fiber from the initial
point Nto the current event point. Contents of information of event list are
shown in follow picture. The event point data and event section data are
separately displayed in the event list. Serial number of event only numbers
the event points. Event category displays the following information by
picture: initial event, optical fiber section, reflection event, non-
reflection event, and end event.
Corresponding pictures of event category are shown in follow picture. When
looking over information of event list, click the icon “event” through the
touch screen, then the information of event list can be found in the info
window.
Optical fiber link information includes file name, measurement date, measurement time, link length, link loss, link attenuation coefficient, and quantity of event. Definition and setting of file name, duration of measurement, and measurement date are shown in “set” menu. When looking over information of optical fiber link, click the “fiber link” through the touch screen, then the information of optical fiber link can be found in the info window. Contents of information of optical fiber link are shown in follow picture.
Information of scale plate includes position of point A (or B), plug-in loss of point A (or B), back scattering coefficient of point A (or B), accumulate loss of point A (or B), distance of A B section, loss between two points of AB section, attenuation coefficient between two points of AB section, and LSA attenuation coefficient of AB section. Sign post is used to mark and analyze a single event, curve section and distance. The information of sign post shows distance, loss and attenuation coefficient between sign posts. When changing any sign post, the record value will also be changed along with it. When looking over information of scale plate, click the icon “scale plate” through the touch screen, then the information of scale plate can be found in the info window. Contents of information of scale plate are shown in follow picture.
Measurement parameter includes laser wavelength, distance scope, pulse width, refractivity,back scattering coefficient, reflection threshold, bundling threshold, non-reflection threshold,and duration of measurement. The definition and setting are shown in “setting” menu. Can click “Fiber link” to view the fiber link information, Fiber link information is shown in follow picture.
Trace zoom
Touch screen zoom operation instructions
Use the center point of the two fingers as the center to zoom. When the
horizontal angle between the two fingers and the center is less than 45
degrees, zoom horizontally.
When the horizontal angle between the two fingers and the center is more than
45 degrees,zoom vertically. Touch the top right thumbnail twice to restore the
original state of the trace.
Trace Movement
Press the trace and move in any horizontal or vertical direction.
Instruction of Trace Operation Button Area
Horizontal amplification: click the button on the touch screen to enlarge the curve horizontally.
Horizontal reduction: click the button on the touch screen to reduce the curve horizontally.
1: 1 restore: restore the scaled curve in the original 1:1 ratio.
After clicking the button on the touch screen, in this state, the left and right arrow keys move the a pole.
After clicking the button on the touch screen, in this state, the left and right arrow keys move the b pole.
After clicking the button on the touch screen, in this state, the left and right arrow keys move the and b pole at the same time.
Move the marker to the left and touch the screen to click the button, the pole A/B in the selected state will move to the left.
Move the stick to the right and touch the screen to click the button, the pole A/B in the selected state will move to the right.
Track switching. This button takes effect only when multiple curve tracks are opened. After clicking the button on the touch screen, you can switch between different curves.
Date Saving
Chick “Quick Save” will auto naming and save the file, according to “Setting-
file setting” name type to name the file.
Click the icon “Save date” to select the path to save the file and modify the
file name. Can choose the save file format in “Setting-file setting”, the file
support PDF and .SOR file format.
Default save files in the internal SD card of the OTDR directory.
Data import
Select the file to be opened in File management, click the “open” in the
bottom to import the curve file.
File management
- Open: Open the selected the curve file, 4 traces can be simultaneously selected at most on main page.
- Rename: Rename the checked file or folder.
- Copy: Copy the selected file or folder to External or internal SD card.
- Delete: Delete the selected file or folder.
- New folder: Create a new folder in the selected directory of “Equipment directory”. The new folder will be used as the default storage path.
- Storage path: Set or view the current storage curve path.
Analysis of “Multi-traces setting”
Click the trace 1/2/3/4 of “Multi-traces setting”, 4 traces can be displayed
at most. The opened traces are distinguished through different colors.
Instruction of Button “Trace 1/2/3/4”
Button icons in the trace operation area are valid to all opened traces
simultaneously. Current trace can be switched through the trace switching
button or through clicking “C 1” (or “C 2”, “C 3”, “C 4”) directly. The data
in the info window is that of the current trace. Or click C1/C2/C3/C4 at left
upper corner to switch the trace.
After the scaling, switching the traces of different ranges will automatically
restored to 1:1.
Switching the traces of the same range will not restore the scaling.
Click “delete” to remove the trace.
Event Map
Display the quantity of event, link loss, link length, link attenuation
coefficient. Click again to switch to trace.
Initial Event: The starting point of link.
Reflection Event: Connector, reflection event is shown as peak signal.
Non-reflection Event: Fusion point or optical fiber bending, non- reflection event is shown as drop of optical power.
End Event: The terminal of fiber, the end event with reflection peak is the normal end.
End Event: Optical fiber bending, the end event with non-reflection peak is the fracture.
Test report
Can save trace trajectory, event, parameter, optical fiber link, rules list
,etc information, can save the 4 traces simultaneously, can create EXCEL or
FDF file test report.
Loss test
Use short standard jumpers to connect the OTDR and LS ports of the instrument
respectively to set the reference value.
After setting the reference value, let’s talk about the optical device being
connected to the OTDR and LS interface of the instrument
It is used to test the insertion loss of optical passive devices.
Click loss test of optical fiber test to enter interface.
Calibration:Connect standard jumper to meter’s OTDR and LS port, click
“Start”, after power is stable, click “Reference”
After setting the reference, connect the tested optical device to meter’s OTDR and LS port, click “Start”, the relative power on the interface is insertion loss value of the tested device
Please calibrate before each test, the test results will be more accurate
Laser source
Laser source output stable power laser with same wavelength as OTDR function,Which be used for engineering and maintenance of optical fiber communication and CATV, fiber parameter setting, the production and research of optical components.
- Open/Off: Turn on/off the laser source
- Wavelength: 1310/1550/1610 are optional, the wavelength same as OTDR module
- Mode: Switch the frequency of laser source, CW/270Hz/330Hz/1000Hz/20000Hz
- Power: Through the slider to adjust the power, the power range is 1-100
- WARNING: Please don’t look the laser directly, will damage the eyes.
- Stability: CW, ±0.2dB/15min (tested after 15min turn on laser source)
Optical power meter
Click icon to enter, with five wavelength 1625nm,1550nm, 1490nm, 1310nm,1300nm, 850nm, linear or nonlinear optical power display, both for optical power testing and Fiber link loss relative measurement. It is necessary tool for installation and maintenance optical fiber communication, cable television and CCTV security system.
Note: Please keep the fiber connector and the dust cap be clean, and clean the detector with the special alcohol.
Visual Fault Locator
Click icon to enter
VFL four status can select——”Steady mode”, “Evasive 1Hz”,”Evasive 2Hz”and
“Time off”. Click button “Steady mode” to enter steady status, click button
“Evasive 1Hz” and “Evasive 2Hz”, to enter pulse mode, click button “Time off
“, VFL is turned off. Timed turn off can select (5 mins, 10 mins, 30 mins, 60
mins and 120 mins).
Click “Steady mode”, red laser source emits steady, click again to quit.
IP camera connection
Connect the IP camera to the IPC tester’s LAN port, if the link indicator of the tester’s LAN port is green and the data indicator flickers, it means the IP camera and the IPC tester are communicating.
IPC Test pro
Enter “IPC Test pro” app, after scanned the IP, click camera IP address, the
tester will auto log in and display the camera image.( This function will auto
turn on PoE power)
The network setting can modify camera’s IP address. The tester’s chrome app
can log in camera website to modify IP information.
HD coaxial camera connection (Optional)
Connect BNC cable to VIDEO IN port of tester, enter “AHD/CVI/TVI” apps will
display the image. Connect the TVI camera’s video output to the IP tester’s
“TVI IN” interface, the image will display on the tester.
Connect BNC cable to VIDEO IN and VIDEO OUT port, enter TV OUT interface, can
test BNC cable’s continuity.
HDMI input (Optional)
DVR or other device’s HDMI out port connect to tester’s HDMI in port, the
meter will display input image.
HDMI output (Optional)
The built in HDMI output port can output live video from an analog or IP
camera, recorded files, media files and images to HDTV monitors. Connect an
HDMI cable from the IP tester to an HDTV monitor at any time. It supports up
to 3840x2160P 30FPS resolution
VGA Input (Optional)
When tester receives VGA in image, the top tool bar shows the resolution of
this image. Tap screen by twice, full image display. Support resolution as
below:
1920x1200P 60FPS, 1920x1080P 60FPS, 1792x1344P 60FPS, 1680x1050P 60FPS,
1600×1200/900P 60FPS/1440x900P 60FPS, 1360x768P 60FPS,
1280×1024/960/800/768/720P 60FPS, 1152x870P 60FPS, 1024x768P 60FPS, 800x600P
60FPS, 640x480P 60FPS
It supports “Snapshot”, “Record”, “Photos”, “Video playback”.
Digital cable tracer
Connect tested cable or BNC cable to the UTP port or the CABLE SCAN (VIDEO
OUT) port on the bottom.
When searching the BNC cable, connect one port of the alligator clips to the
copper core or copper net of the BNC cable, the other one to connect the earth
wire (barred windows). Note: Press “Mode” seconds to turn on the wire tracer,
then can start the cable searching.
Quickly to verify the tracking result (Only for RJ45 port)
After hunt the cable, connect the network cable to wire receiver “UTP” port
for pair line detection, For example, when the “Straight/Cross/Other” light
up, indicates the verification of the matching cable, the indicator also shows
the type of the cable.
UTP cable test
Connect LAN cable or telephone cable to UTP port of tester, the other end
connect to UTP port of wire receiver, enter cable test app to test cable’s
continuity and sequence.
The continuity detection of the RJ45 cable plug
Connect one end of cable to tester’s UTP port, can test the continuity of this
RJ45 cable plug. If the 1-8 of tester are “√”, indicating that the RJ45 cable
plug is normal, if display “x”, indicating that this core of the port is
disconnected. (Note: The cable within 1 meter from the port)
RJ45 cable TDR test
Connect cable to the LAN port of tester, the other end connect or disconnect
other device. Enter “RJ45 cable TDR test” app to test cable’s length, short-
circuit, status, attenuation, reflectivity and skew, etc. parameters.
Test cable’s length, please don’t connect any device. The max measurement
length is 180 meter. Test cable’s skew, please connect the gigabit camera.
Specification
OTDR Technical Specifications
Wavelength (nm) Optional | 1310/1550| 1610
Dynamic range(dB) 2 Optional| 28/26| 30/28| 32/30| 34/34| 28| 30|
32| 34
Pulse width (ns)|
5,10,20,30,50,80,160,300,500,800,1000,2000,4000,6000,10000,20000
Testing range| ≤150 Km
Event blind zone (m) 3| ≤2m
Attenuation blind zone (m) 3| ≤10m
Linearity (dB/dB)| ±0.05 dB/ dB
Loss threshold (dB)| 0.05
Loss resolution ratio (dB)| 0.01
Minimum distance resolution| 0.05
Sampling point(K)| 32-128
Distance uncertainty (m)| ±(1 m + 5×10-5× distance + sampling interval)
Distance scope (km)| 0.5,1,2,5,10,25,50,100,200
Typical real-time refreshing duration| 1s
File format| SOR standard format/PDF/EXCEL
Measurement duration| 5sec, 10sec, 15sec, 30sec, 1min, 2min, and 3min are
selectable
Storage| FLASH (EMMC)8G + TF card
Interface type| FC/SC-PC
Remarks:
1. The technical specification describes the ensured performance of the instrument when using typical PC model connector to measure, without considering the uncertainty caused by optical fiber refractivity.
2. Dynamic range is the data measured under the condition of the maximum pulse width and 3 minutes of average time. Dynamic range is the data measured under the condition of 200km/20000ns/3min.
3. Measuring conditions of blind zone: reflection event is within 5Km, reflection strength is 45dB. Measured by the minimum pulse width.
Specification
Size & Display Network Port WIFI
H.265 mainstream test IP camera test
IP discovery
HD coaxial camera test CVBS camera test Zoom Image
| 5.4 inch IPS touch screen display, 1920*1152 resolution
Dual 1000M LAN port, 10/100/1000M auto adapt
Built in 2.4G WIFI, speeds150M, display wireless camera image
H.265 & H .264 IP, 8K video display via mainstream
Support 500 brands IP camera test
Auto-scan the whole network segment IP address
TVI 5.0/ CVI 4.0/ AHD 4.0 camera test, UTC control & call OSD menu
Optional
1 channel BNC input & 1 channel BNC looped output, NTSC/PAL (Auto adapt)
Optional
4x zoom, enlarge image, screen snapshot, save, view and record and playback
RJ45 cable TDR test| Test cable pair status, length, attenuation,
reflectivity, and impedance, skew etc. measurement range
180M.
HDMI input/output VGA input
Power output
| 4K 60FPS HDMI input 4K 30 FPS HDMI output Optional
Support VGA input *** Optional
48V PoE/ 24V2A/ 12V 3A / 5V 2A power output
UTP cable test**| Test UTP cable connection status and display on the
screen. Read the number on the screen. detect
the near-end, mid-end and far-end fault point of RJ45 cable connector, also can test shield cable
Data monitor
Network test Digital Cable tracer
| Captures and analyzes the command data from controlling device, also can
send hexadecimal
Trace route, Link monitor, DHCP server, port flashing, Ping test
Search BNC cable, network cable and telephone cable from the mess cables.
| Voltage range| AC12-1000V
Electroscope
| Frequency| 50/60Hz
Alarm type| Sounds and light double alarms
| Level| CAT.III 1000V / CAT.IV 600V;CE
PoE Voltage test| Measurement POE switch or PSE power supply voltage and
cable connection status
Visual fault locator| 10mW visual fault locator with 650nm wavelength,
emit red laser sources to test multi-mode and
single mode fiber’s bending and breakage, test range 8KM
Optical power meter
| Wavelength:1625,1550nm,1490nm,1310nm,1300nm,850nm, measurement range ,-70 ~
+10 dBm,
| for optical power testing and Fiber link loss relative measurement
Power
External power
supply
| DC 12V(2A)
Battery| Built-in 7.4V 5200mA Li-ion Battery
Rechargeable| After charging 2.5 hours, normal working time 11 hours
Parameter
Operation setting| OSD menu, select your desired language: English,
Portuguese, Korean, Russian, Italian, French, Polish,
Spanish, Japanese, Turkish, Deutsch, Serbian, Czech, Vietnamese etc
Auto off| 5-30 (mins)
Working environment
Working
Temperature
| -10℃—+50℃
Working Humidity| 30%-90%
Dimension/Weight| 264mm x 182mm x 43mm / 1Kg
Remarks:
- The technical specification describes the ensured performance of the instrument when using typical PC model connector to measure, without considering the uncertainty caused by optical fiber refractivity.
- Dynamic range is the data measured under the condition of the maximum pulse width and 3 minutes of average time. Dynamic range is the data measured under the condition of 200km/20000ns/3min.
- Measuring conditions of blind zone: reflection event is within 5Km, reflection strength is 45dB. Measured by the minimum pulse width.
Please Note: “*”sign mean that functions are customisable!
The data above is only for reference and any change of them will not be
informed in advance. For more detailed technical inquiries, please feel free
to contact us.
Comparison Table
Feature/Model | MT-6500 | MT-6510 | MT-6800 | MT-6810 |
---|---|---|---|---|
OTDR | √ | √ | √ | √ |
Analog camera test | x | √ | x | √ |
IP camera testing | 4K | 4K | 8K | 8K |
8MP AHD/CVI/TVI test | x | √ | x | √ |
Stable laser sources | √ | √ | √ | √ |
Optical power meter | √ | √ | √ | √ |
Visual fault locator | √ | √ | √ | √ |
Cable tracer | √ | √ | √ | √ |
VGA input | x | √ | x | √ |
HDMI input | x | √ | x | √ |
HDMI out | x | x | √ | √ |
Advanced network tool | √ | √ | √ | √ |
Interface type | SC-PC | SC-PC | FC/SC-PC | FC/SC-PC |
LAN port | Only one LAN port | Only one LAN port | **Dual LAN | |
port** | Dual LAN port | |||
Only support cable’s | Only support cable’s | Support cable ‘s | Support cable |
‘s
RJ45 TDR cable test| opens and shorts, Max| opens and shorts,| open and
short| open and short
| 600m| Max 600m| attenuation| attenuation
| | | /reflectivity/impe| /reflectivity/impedan
| | | dance and skew,| ce and skew, Max
| | | Max 180M| 180M
Packing list
- Tester
- Cable tracer
- Adaptor DC12V 2A/ 8GB TF card
- Li-ion Battery (7.4V 5200mAh)
- Tool bag / DC12V Power cable/BNC cable/ RS485 cable/RS485 port/ Audio cable/ Safety cord
- SC connector, FC connector, fiber test head
- BNC alligator clamp
- RJ45 to BNC connector
- OTDR test report
www.cctvtester.com
After-sales service department(sales@testerpro.com.cn)
References
Read User Manual Online (PDF format)