ABBREE AR-M7 CB Radio Instruction Manual
- June 16, 2024
- ABBREE
Table of Contents
AR-M7
CB RADIO
Instruction Manual
ACCESSORIES
KNOW ABOUT THIS RADIO
2.1 Front panel function
No. | Button | Function |
---|---|---|
1 | Power On/ Off button | |
2 | Mute/ Keypad lock button | |
3 | Squelch function/ Store memory channel function button | |
4 | VOX function button | |
5 | ASQ (Automatic Squelch Control) function/ Store memory channel function |
button
6| | Channel switch/ Store memory channel function button
7| | Modulation switch button
8| | CTCSS/DCS function / Store memory channel function button
9| | Scan channel function button
10| ****| Emergency channel button
11| | Volume knob/ Push/ Function menu button
12| MIC| Microphone interface
13| LCD| Display the status of channel/frequency and various function settings
After pressing the PUSH button, press the following buttons to enter function:
Button | Function |
---|---|
Choose storage memory channel M1 | |
Choose storage memory channel M2 | |
Choose storage memory channel M3 | |
Choose storage memory channel M4 |
Hold on pressing the following buttons to enter function:
Button | Function |
---|---|
Store/ delete memory channel M1 | |
Store/ delete memory channel M2 | |
Store/ delete memory channel M3 | |
Store/ delete memory channel M4 | |
Add/ remove scan channel list |
2.2 Rear Panel
NO. | Button | Function |
---|---|---|
1 | Antenna Interface | Install the antenna here, the impedance is 50Ω |
2 | External Speaker Jack | Connect the optional external speaker SP01 here |
3 | Power cable | Connect the standard DC (Direct Current) power cable here |
2.3 Microphone
HOW TO USE THIS RADIO
3.1 Power On/Off the Radio
- Power On the radio: Press the button, the screen will light up and display “WELCOME”, then the radios will show the current frequency or channel, it’s on.
- Power Off the radio: Press the button for 2 seconds, the screen will display “CLOSING”, then all the display will disappear, it’s off.
3.2 Volume Adjustment
When the radio is under standby, turn the VOL knob to adjust the volume, turn
it clockwise to increase the volume, and turn it counterclockwise to decrease
the volume.
Note: Set the volume level during a call to adjust the desired volume
more accurately.
3.3 Quick Mute Setting
Under standby state, short press the key, the screen will display the mute
icon to enter mute mode; Short press the key again or turn the VOL knob, the
screen displays the volume level to exit the mute mode.
3.4 Enter Stored Memory Channel and Exit Out
Enter Stored Memory Channel: Short press the [PUSH] button, the screen will
displays the “FUNC” icon, then press the corresponding M1-M4 to enter the
memory channel mode; Short press the CH/M3 button when the channel number is
blue, and then turn the VOL knob to exit the memory channel mode out.
3.5 Store Memory Channel
In the non-storage channel, select the channel you want to store, and hold
on press the corresponding M1-M4 button until the screen displays the storage
channel number and emits a “DiDi” sound, and the storage is completed.
3.6 Delete Memory Channel
Under the storage channel, hold on press the corresponding M1-M4 button
until the storage channel number displayed on the screen disappears and a
“DiDi” beep sounds, and the storage channel deletion is completed.
KEYPAD FUNCTION
4.1 Button
Keypad Lock Function
- Hold on press the **** key for 2 seconds to turn on the keypad lock function, and the screen will display the ” ” icon.
- Hold on press the **** key again for 2 seconds to turn off the keypad lock function.
Note: When the key is locked, the PTT key /VOL switch knob is valid, and
the other keys are invalid.
4.2 Button
SQ Level Selection
Short press the ** button to display the current SQ level on the LCD. You
can select the desired SQ level by rotating the VOL switch or pressing the
[UP/DOWN] button of the microphone. There are OFF and 1-34 levels to choose.
4.3 Button
VOX Function
Short press the button to turn on the voice control function, short press the
button again to turn off the voice control function.
4.4 Button
Automatic Squelch Level Selection
Short press the button to display the current ASQ level on the LCD. You can
select the desired ASQ level by rotating the VOL knob or pressing the
[UP/DOWN] button of the microphone. There are 1-9 levels to choose.
4.5 Button
Channel Selection
In the channel mode, short press the button, when the channel number is blue,
turn the VOL knob or press the [UP/DOWN] button of the microphone to select
the desired channel. Turn clockwise to adjust to the next channel , turn
counterclockwise to the previous channel.
4.6 Button
Modulation Mode Selection**
- Short press the button to switch the communication modulation mode AM/FM.
- The selected modulation mode will be displayed on the LCD.
4.7 Button
CTCSS/ DCS Code Function
- Short press the
-
- button to enter the CTCSS/DCS encode and decode function, and the screen will displays the “CTC or DCS” icon.
- Short press the button for the first time to enter the CTCSS encode and decode signaling function.
- Short press the button for the second time to enter the DCS encode and decode signaling function.
- Short press the button for the third time to turn off the CTCSS/DCS codec encode and decode signaling function.
4.8 Button
Scan Function
- Short press the button to enter the scan function, and the screen will flashes a red “S” icon.
- Under the scanning state, press the button and then turn the VOL knob or press the [UP/DOWN] button of microphone to change the scanning direction.
- Short press the button or the PTT button again to exit scan.
Add/ Delete Scan List
- Hold on press the key for 2 seconds to set the current channel to be added to the scan list or deleted it from the scan list.
- When the screen shows “S” icon, it means that the current channel is not in the scan list, and the channel will not be scanned during scanning.
- When the screen doesn’t show “S” icon, it means that the current channel has been added to the scan list, and the channel will be scanned when scanning.
4.9 Button
Emergency Channel Function
Short press the button to enter the emergency channel function, and the screen
displays the “EMG” icon.
- Short press the button once to choose the CH9 channel.
- Short press the button twice to choose the CH19 channel.
- Short press the key thrice to return to the original channel.
4.10 【PUSH】Button
Hold on press the [PUSH] button for 2 seconds to enter the function menu
setting.
4.11 Norms and Frequency
- In the power off state, hold on press the A/F button to power on the radio and displays the norms in LCD.
- Turn the knob or press the UP/DN button of the microphone to select norms.
- Turn off the radio to confirm selected norms and exit.
4.12 Install External Speake
If you plan to install external speakers, choose speakers with 8Ω and a
3.5mm mono (two-conductor) plug.
- Install the external speakers in an ideal position.
- Plug the speaker connector into jack.
FUNCTION MENU OPERATION
Hold on press the [PUSH] button to enter sub MENU, rotate the VOL knob to
switch betwen sub menu : Functions or PARA-SET or TIME-DATE Press the [PUSH]
button to enter the sub menu list,
Rotate the VOL knob to select the function options;
Press the [PUSH] button to enter the selected function, rotate the VOL knob
for setting, and press the [PUSH] button to save the setting;
Short press the EMG button to exit the function setting menu step by
step. 5.1
FUNCTION MENU SETTING
NO. | LCD display | Function detail | Setting details |
---|---|---|---|
1.1 | Display brightness of backlight setting | Option 1~5, there are 5 levels |
to choose; Default: 5
1.2| | Keypad brightness of backlight setting| 1~5, there are 5 levels to
choose; Default: 5
1.3| | Keypad beep setting| OFF:Shut beep function ON:Open beep function
Default: ON
1.4| | Power on setting| OFF:Turn off the automatic power-on function ON:Turn
on the automatic power-on function
1.5| | Scan type setting| SQ:SQ scan function TI:Time scan function
1.6| | Scan range setting| OFF:Turn off scan range function ON:Turn on scan
range function Default: ON
Note: Set the scan begin channel or frequency when “S” is displayed in the
menu, and set the scan stop channel or frequency when “E” is displayed
1.7| | Dual watch channel setting| One of 1-40 channels can be set, the
channel before entering menu is another dual watch channel
Default: 09
1.8| | Dual watch function setting| OFF: turn off the dual watch function. ON:
turn on the dual watch function. Default : OFF
1.9| | TOT settings| OFF~600S, 10 minutes to choose, OFF is to turn off TOT
function;
Default: 60S
1.10| | RF gain setting| OFF/ AU/ 03/ 06/ 09~48, total 18 types to select, OFF
is to turn off the RF gain function; Default: OFF
Note: If set the AUTO RFG function, the radio will turn on the automatic RFG
function.
1.11| | Microphone type settings| DY:Dynamic MIC EL:Electronic MIC Default: EL
---|---|---|---
1.12| | Microphone sensitivity settings| 1~9, total 9 levels, the higher level
the higher sensitivity of microphone;
Default: level 6
1.13| | TALK BACK function settings| OFF/ 1~9, total 10 levels, the higher
level the louder it will sound;
Default: OFF
1.14| | NC function settings| OFF:turn off NC function; ON:turn on NC
function; Default: OFF
1.15| | NG function settings| OFF turn off NG function; ON:turn on NG
function; Default: OFF
1.16| | PA function settings| OFF:turn off PA function; ON:turn on PA
function; Default: OFF
1.17| | VOX sensitivity settings| 1~9, total 9 levels, the higher level the
higher sensitivity of VOX;
Default: level 3
1.18| | VOX delay time settings| 1~9, total 9 levels, the higher level the
longer delay time of VOX; Default: level 4
1.19| | SWR protection settings| OFF/ 2.0/ 2.5/ 3.0/ 4.0/ 5.0/ 10.0, OFF is to
turn off SWR protection function Default: OFF
1.20| | Power on display settings| DEF PIC: default picture display
USET PIC: Customized picture display (can be written by PC software)
CHAR: indicates the name
BAT: voltage display Default : DEF PIC
1.21| | RX NRC(Noise reduction) function setting| OFF: Turn off NRC function
ON: Turn on NRC function”
Default: OFF (**Optional function, only have this function when NRC PCB added)
1.22| | Factory reset settings| ALL the channels, function settings will be
back to factory default settings
5.2 RARA-SET MENU SETTING
NO. | LCD display | Function detail | Setting details |
---|---|---|---|
2.1 | Public channel settings | OFF:turn off public channel function; ON:turn |
on public channel function; Default: ON
2.2| | Add/ delete scanning settings| ADD:Add scanning list SKIP:Delete
scanning list Default: ADD
2.3| | CTCSS/DCS Decode settings| OFF:Turn off CTCSS/DCS function
CTCSS:C01-67.0Hz~C38-250.3Hz; DCS:D001-023N~D104-754N;
Default:OFF
2.4| | CTCSS/DCS Encode settings| OFF:Turn off CTCSS/DCS function
CTCSS:C01-67.0Hz~C38-250.3Hz; DCS:D001-023N~D104-754N;
Default:OFF
2.5| | CTCSS/DCS Decode & Encode settings| OFF:Turn off CTCSS/DCS function
CTCSS:C01-67.0Hz~C38-250.3Hz; DCS:D001-023N~D104-754N;
Default:OFF
2.6| | HI-CUT function settings| OFF:turn off HI-CUT function; ON:turn on HI-
CUT function; Default: ON
2.7| | NB function settings| OFF:turn off NB function; ON:turn ON NB function;
Default: ON
2.8| | RB function settings| OFF/ 1/ 2~8, total 9 levels, OFF is to turn off
RB function
Default: OFF
2.9| | Busy channel lock out function settings| OFF:turn off Busy lock-out
function; ON:turn on Busy lock-out function; Default: OFF
5.3 TIME-DATE MENU SETTING
NO. | LCD display | Function detail | Setting details |
---|---|---|---|
3.1 | CLOLK SETTING | Setting hours and minutes, the radio is 24hours system |
display
3.2| | DATE SETTING| Setting DATE,MONTH,YEAR
3.3| | DISPLAY SETTING| CLOCK:clock display VOLTAGE:voltage display
DEFAULT:CLOCK
3.4| | SCREEN SAVER TIME SETTING| OFF,5,10~60S,total 13 levels for optional
DEFAULT:OFF
3.5| | CLOCK COLOR SETTING| WHITE:White YELLOW:Yellow RED:Red
GREEN:Green CYAN:Cyan DEFAULT:WHITE
3.6| | POWER OFF SCREEN SAVER SETTING| OFF: close SCREEN SAVER display
function CLOCK: open SCREEN SAVER display function DEFAULT:OFF
SPECIFICATION
GENERAL
Modulation Mode| AM/FM
Frequency Range| 26.965-27.405MHz
Frequency Tolerance| ±5.0ppm
Dimensions(in mm)| 188x78x58mm
Ferquency Control| PLL Synthesizer
Operating Temperature Range| -20℃ TO + 55℃
Current Drain| Transmit| 3A MAX
Receive| Squelched 0.3A
VOL Max| 0.8A
TRANSMITTER
Power Output| 4 Watt FM/AM
Transmission interference| inferior to 4nW(-54dBm)
Frequency Response| 300-3000Hz
Modulated signal distortion| inferior to 5%
Output Impedance| 50 ohms
RECEIVER
Sensitivity| Less than 1uV for 10dB(S+N)/N
Image Rejection| 70dB
Adjacent Channel Rejection| 60dB
IF Frequencies| 1st 10.695MHz
2nd 455KHz
Automatic Gain Control(AGC)| Less than 10dB change in audio
Output for inputs from 10 to 50000uV
Squelch| less than 1uV
Audio Output Power| 1Watts
Frequency Response| 300-3000Hz
FCC Compliance Statements:
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential
installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
WARNING:
MODIFICATION OF THIS DEVICE TO RECEIVE CELLULAR RADIOTELEPHONE SERVICE SIGNALS
IS PROHIBITED UNDER FCC RULES AND FEDERAL LAW.
RF Exposure and Separation Distance:
For safe operation, the minimum separation distance should be 36.2cm.
Xiamen Aorui Electronics Co.,Ltd
Documents / Resources
|
ABBREE AR-M7 CB
Radio
[pdf] Instruction Manual
AR-M7 CB Radio, AR-M7, CB Radio, Radio
---|---
Read User Manual Online (PDF format)