FAGERHULT 23536 Notor Recessed LED Delta Luminaire Instructions

June 16, 2024
FAGERHULT

FAGERHULT 23536 Notor Recessed LED Delta Luminaire

FAGERHULT-23536-Notor-Recessed-LED-Delta-Luminaire-
product

Product Information

Specifications

  • Art.no.: 23536
  • EAN: 7320046503024
  • Product Name: Notor recessed LED Delta
  • Installation Type: Single
  • Light Distribution: Direct
  • Color: White
  • Module: 600 Louvre Delta RAL 9016
  • Lumen Output: 1289
  • CCT (Correlated Color Temperature): 4000K
  • SDCM (Standard Deviation of Color Matching): 3
  • Lumen Maintenance (L89): 75,000 hours
  • Lumen Maintenance (L80 B50): 100,000 hours
  • LED Driver Life: 100,000 hours with a maximum failure of 10%
  • Luminous Efficacy (lm/W): 101
  • CRI (Color Rendering Index): 80
  • Lumen Maintenance (L93): 50,000 hours
  • Lumen Maintenance (L86): 100,000 hours
  • Lumen Maintenance (L90 B50): 70,000 hours
  • Energy Class (LED module): C
  • Driver Brand: Tridonic
  • Dimensions:
    • Length: 585mm
    • Height: 102mm
    • Width: 90mm
    • Weight: 2.4kg

Product Usage Instructions

Installation
The Notor recessed LED Delta is designed for installation in all types of suspended ceilings. It features Delta louvers that provide high efficiency and optimal lighting comfort. It can be installed as a single unit or in a continuous installation.

Single Installation:

  • Mount the luminaire in ventilated or unventilated suspended ceilings.
  • For suspended ceilings with visible T-bars or VTB (15 or 24 mm), or one-piece suspended ceilings, the luminaire can be installed.
  • If you want to perform a continuous installation with combinations of asymmetric/Control Track Unit and Delta/Opal flush, please refer to the documents provided.

Connection:

  • The connection is made through a connection box located on top of the luminaire.
  • Use a 3-way chassis connector (GST 18i3) for regular connection, and a 5-way chassis connector (GST 18i5) for dimming.
  • In continuous installations, always start the luminaire row with a start luminaire.
  • The luminaire units are interconnected with a connection cable in the connection box.

Design
The luminaire body is available in natural anodized, extruded aluminum or white enameled (RAL 9016) finishes. With continuous installation, an unbroken line of light is achieved, even with an L-coupling.

Accessories

  • End caps for the luminaire need to be ordered separately and are not included in the package.
  • For additional accessories and cables, please refer to the Accessories section.

Calculating Luminaire Requirements
To calculate the number of luminaires and accessories needed to complete a run, please use our configurator tool.

Important Notes

  • NOTE 1: Do not mix Low Lumens (LL) and High Lumens (HL) luminaires in continuous installations.
  • NOTE 2: For exact lengths, please refer to the dimension drawing.

FAQ (Frequently Asked Questions)

  • Q: Can I mix Low Lumens (LL) and High Lumens (HL) luminaires in continuous installations?
    A: No, it is not recommended to mix Low Lumens (LL) and High Lumens (HL) luminaires in continuous installations.

  • Q: Where can I find the dimension drawing?
    A: The dimension drawing can be found in the user manual or product documentation.

Important Instruction

A recessed luminaire for all types of suspended ceilings. Delta louvers provide high efficiency and optimal lighting comfort. Single or continuous installation.

  • Installation of Luminaire mounted in ventilated or unventilated suspended ceilings. Installed in suspended ceilings with visible T-bars, V TB (15 or 24 mm), or one-piece suspended ceilings. For continuous installation with combinations of asymmetric/Control Track Unit and Delta/Opal flush, see the documents below.
  • Connection Connection employs a connection box on top of the luminaire. Wieland Chassis connector 3-way (GST 1813), with dimming 5-way (GST 1815). In a continuous installation, the luminaire row should always start with a start luminaire. With continuous installation, the luminaire units are interconnected with a connection cable in the connection box.
  • Design Luminaire body in natural anodized, extruded aluminum or white enameled (RAL 9016). With continuous installation, an unbroken line of light is achieved, even via a L-coupling.
  • Louvre Delta – microprism louvre in acrylic (PMMA) with a thin opal diffuser (acrylic/PMMA) on the inside (PMMA).
  • Accessories End caps are ordered separately (not included).
  • For miscellaneous Accessories and cables, see Accessories.
    • To calculate how many luminaires and accessories you will need to complete a run, please use our configurator.
    • NOTE! Do not mix Low Lumens (LL)- and High Lumen (HL-luminaires in continuous installations.

NOTE!
Do not mix Low Lumens (LL)- and High Lumen (HL)-luminaires in continuous installations.

For exact lengths, please refer to the dimension drawing.

Specifications

Notor recessed LED Delta
Direct, Single, HL

DESIGN

  • Installation Single
  • Light distribution Direct
  • Colour White
  • Module 600
  • Louvre Delta
  • RAL 9016

LIGHT DATA & PERFORMANCE

  • Lumen output 1289
  • ССт, к 4000
  • SDCM 3
  • Lumen maintenance 75 000 h L89
  • Lumen maintenance L80 B50, h 100000
  • LED driver, h/max failure % 100000/10
  • Im/W 101
  • CRI 80
  • Lumen maintenance 50 000 h L93
  • Lumen maintenance 100 000 h L86
  • Lumen maintenance L90 B50, h 70000
  • Energy class, LED module C

CONTROLS & CONNECTIVITY

  • Driver brand Tridonic

ELECTRICITY & ENCLOSURE

  • Rated supply voltage, V 220-240
  • Protective class 1
  • System Wattage 13
  • Max. ambient temperature, °C 25
  • MCB B16A 36
  • MCB С16А 60
  • Surge protection CM, kV/kA 2
  • Power factor, 100% 0.85
  • Mains frequency, Hz 0, 50, 60
  • IP rating 20
  • Min. ambient temperature, °C -25
  • MCB B10A, pcs 23
  • MCB С10А 35
  • THD, % 18
  • Surge protection DM, kV/kA 1

DIMENSIONS

  • Length, mm 585
  • Height, mm 102
  • Width, mm 90
  • Weight, kg 2.4

FAGERHULT-23536-Notor-Recessed-LED-Delta-Luminaire-