daviteq CAP10CNC Module Instructions
- June 16, 2024
- daviteq
Table of Contents
Module CAP10CNC
USER GUIDE FOR MODULE
CAP10CNC
FEB-2020
This document is applied for the following products
Module CAP10CNC
Specification
Output | 4-20mA output (with 250 ohms precision resistor), or RS485/ModbusRTU |
---|---|
Power supply | 8..50VDC |
Consumption | max 35mA |
Capacitance range | 0-400 pF |
Working temperature | -40 oC .. + 85 oC |
Instructions for configuration
3.1 Wiring
Please wiring as shown below:
3.2 Soldering wire connected to input C signal
- Solder the signal C to the middle point of the circuit.
- Choose 1 of 3 points on the edge of the circuit (1 or 2 or 3) to connect GND.
3.3 Calibration
Zero: Power the circuit, press the button 3 times consecutively then wait for
the LED to blink continuously, we will press one more time. Disconnect power.
Full-scale: Power the circuit, press the button 3 times consecutively
then wait for the LED to blink continuously, we will hold the button, when the
light is off we take our hands off.
References
- daviteq.com/en/manuals/uploads/images/gallery/2020-06/3UklBYzS6ke0jpt2-DSC_0121.png
- daviteq.com/en/manuals/uploads/images/gallery/2020-06/B5BJn9VL01ziaxaV-DSC_0122.png
- daviteq.com/en/manuals/uploads/images/gallery/2020-06/D7rjIpAZfQoNirLf-DSC_0119.png
- daviteq.com/en/manuals/uploads/images/gallery/2020-06/qUHobg73wu3pRAEC-DSC_0115.png
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>