Aroma Link OS-35A6PRO300 Smart Scented Air Machine Bluetooth and WiFi Waterless Essential Oil Diffuser User Manual
- June 15, 2024
- Aroma Link
Table of Contents
- OS-35A6PRO300 Smart Scented Air Machine Bluetooth and WiFi Waterless
- Cautions
- Instruction
- Schematic diagram of connecting air-conditioning duct
- Operation Introduction
- The main common problems after long-time not using.
- Accessories and spare parts
- Accessories and spare parts
- After-sales Service
- The equipment warranty and precautions
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Instruction Manual
OS-35A6PRO300 Smart Scented Air Machine Bluetooth and WiFi Waterless
Essential Oil Diffuser
|
---|---
https://apps.apple.com/cn/app/aroma-link/id1505915988| http://www.aroma-
link.com/download.html?type=Android&language=EN
To start configuring the diffuser on phone, please scan QR code to download
“Aroma Link” App.
Attached Warranty Card
APlease keep the Instruction and the warranty Card carefully for further
reference.
Please read all instructions before using the device.
Cautions
(The foliowing basic safety precautions should be always complied with)
Avoid casualties and property loss, please always follow the attentions as the
following.
**warning**
May cause electric shock or fire hazard.
Installing
- D0 not use unsafe plug or power cable.
- Donot install the device at the place where children can reach
- Do not install the device at the place where can not bear strength and prone resultin falling and collapsing
- Do not tlt the device.
- Keep the device away from fire and heat source, prohibit to store flammable and explosive materials around the device.
- Except for the atomizer, the housing material is not resistant to corrosion
- Do not use device in high temperature or wet environment.
- D0 not use inflammable, explosive, corrosive and other hazardous solvents work with the device.
- Do not mix essential oil with water for using in diffuser.
Note
May cause personal injury or property damage
Installing
- Ensure the firmness of installation area.
- Install the device in a ventilative and adequate space.
- D0 not block the sprayer by hand or other obstructions when the device is working.
- D0 not spill water or conductive, corrosive liquid on the device surface or fall inside of the device.
- D0 not operate device without stopping. Suggested average daily usage time should not exceed 14 hours, and the second level is recommended
- Cut off the power in extreme weather environment.
Instruction
Approved Cerificate: CE. FCC. RoHS, CNAS and so on.
Application Place: Hotel. 4S Car store. Brand Shop. Bar. Public Area and so
on.
Schematic diagram of connecting air-conditioning duct
Operation Introduction
-
The device has four buttons : “ ” is the retum bution” ” is confirnation button, “ @ ” isthe increasing button and * ® ” is the shift button.
-
Buttons operation:
Under the normal working interface, press “ “and “ ” buttons at the same time to enter the password setting interface. -
Under the normal working interface, press “ ” and ” ” buttons at the same time to enter local time setting interface.
-
Under the normal working interface, press “ ” button to enter the working time and frequency setting interface.
-
Under the normal working interface, long press “ ” button to tum on/off the fan.
-
Under the normal working interface, long press “ ” button to tum off the machine,
Factory Reset:
Under the normal working interface, firstly, press the “ “and “ ” buttons at
the same.
time until the interface show YESINO, then let your hand go. Secondly .operate
“ ” to choose YES then press “ ” button to confirm it and finish the setting.
The main common problems after long-time not using.
Reason | Solution |
---|
1.The PCB can not work
a.PCB damage.
b.The battery s dead.
C .PCB poor welding resulting in insensitive contact,
d.Power cutoff.| AChange the PCB.
B Replace the battery.
C Replace the PCB.
D.Check the adapter and power cable.
2.Equipment can not work, but the PCB display normally
a.The pump system is broken.
b.Time seting
cnner ciruit problems.| A.Change a pump.
B.Check the time satting
C.Check the inner circu{mullimeter).
3.Abnormal Noise
a.Pump is broken, aged or loose.
b. Trachea cable connection occurs problems,
C .Internal structure is damaged,| AAdjust or Change a pump.
B Check the cable connection
C Adjust or change parts.
4.Machine works but no scent or scent is weak
a.The nozzle is blacked.
b.The pipette falls off.
.The pump system is aged.
d.The atomizer is blocked.
&.There are impurities in the essential ol| A.Change a nozzle(First with
alcohol soak for a few minutes) or with a fine neede to clear the nozze.
B.Reconnect the pipette.
C.Change a pump.
D. Clean the atomizer.
E.Replace with pure essential ol
5.0il Leakage
a.The equipment s filted
b.The atomizer leaks| APutthe machine straight.
B.Change a new atomizer.
Accessories and spare parts
Please clean the equipment periodically,suggest 2-3 months in 1 circle , so
that it can ‘work under best condition.
Please cut off the power when cleaning, also do not use wet hand to operate it
directly, in case of electric shock and injury.
1.Long-term non-use
- Please tur off and cut off the power then roll up the power cord.
- Clean the filter components.
- Place the deodorant package which contains activated carbon in the device or package, to prevent residual substances in the equipment produce odor.
- Please equip the machine with the dust cover, placed in the shade, ventiative place.
Accessories and spare parts
After-sales Service
- Provide free technical solutions and installation process guidance.
- Provide free online FAQ consultation and scent-marketing suggestion
The equipment warranty and precautions
- The equipment warranty period is 12 months (from the date of sale).
- Please provide the warranty card,Invoice o other provement which can prove the equipment was ordered in our company to enjoy the free maintenance.
- The human error or other wrong operation cause the fault not belong to the scope of warranty, and will not be accepted to provide free maintenance.
Name | Quantity | Name | Quantity |
---|---|---|---|
Aroma diffuser | 1 PC | Screws (including plastic expansion tube) | 2PC |
Adapter | 1 PC | Manual | 1 PC |
Cap | 1 PC | Warranty card | 1 PC |
Air conditioning tube | 1 PC | Bottle sealing gasket | 1 PC |
Key | 2PC | ||
Connector | 1 PC |