Champion Power Equipment 100571 3500W Portable Inverter Generator Instruction Manual
- June 15, 2024
- CHAMPION POWER EQUIPMENT
Table of Contents
OPERATOR’S MANUAL
MODEL #100571
3500W PORTAbLE INvERTER GENERATOR
REGISTER YOUR PRODUCT ONLINE
at championpowerequipment.com
100571 3500W Portable Inverter Generator
or visit championpowerequipment.com
3629-M-OP RE V 20230111
Champion Power Equipment, Inc., Santa Fe Springs, CA USA
CARBON MONOXIDE SAFETY: THE BIG PICTURE
As the only safe way to use a portable generator, taking your generator
outside is absolutely mandatory to keep your family safe from carbon monoxide.
But there’s even more you can do. By educating yourself about all carbon
monoxide risks, you’ll be better prepared to protect your family from this
colorless, oderless threat.
www.TakeYourGeneratorOutside.com
100571 – 3500W PORTAbLE INvERTER GENERATOR
INTRODUCTION
Congratulations on your purchase of a Champion Power Equipment (CPE) product.
CPE designs, builds, and supports all of our products to strict specifications
and guidelines. With proper product knowledge, safe use, and regular
maintenance, this product should bring years of satisfying service.
Every effort has been made to ensure the accuracy and completeness of the
information in this manual at the time of publication, and we reserve the
right to change, alter and/or improve the product and this document at any
time without prior notice.
CPE highly values how our products are designed, manufactured, operated, and
serviced as well as providing safety to the operator and those around the
generator. Therefore, it is IMPORTANT to review this product manual and other
product materials thoroughly and be fully aware and knowledgeable of the
assembly, operation, dangers and maintenance of the product before use. Fully
familiarize yourself, and make sure others who plan on operating the product
fully familiarize themselves too, with the proper safety and operation
procedures before each use. Please always exercise common sense and always err
on the side of caution when operating the product to ensure no accident,
property damage, or injury occurs. We want you to continue to use and be
satisfied with your CPE product for years to come.
When contacting CPE about parts and/or service, you will need to supply the
complete model and serial numbers of your product. Transcribe the information
found on your product’s nameplate label to the table below
CPE TECHNICAL SUPPORT TEAM
1-877-338-0999
MODEL NUMBER
100571
SERIAL NUMBER
DATE OF PURCHASE
PURCHASE LOCATION
SAFETY DEFINITIONS
The purpose of safety symbols is to attract your attention to possible dangers. The safety symbols, and their explanations, deserve your careful attention and understanding. The safety warnings do not by themselves eliminate any danger. The instructions or warnings they give are not substitutes for proper accident prevention measures.
DANGER
DANGER indicates a hazardous situation which, if not avoided, will result in
death or serious injury.
WARNING
WARNING indicates a hazardous situation which, if not avoided, could result in
death or serious injury.
CAUTION
CAUTION indicates a hazardous situation which, if not avoided, could result in
minor or moderate injury.
NOTICE
NOTICE indicates information considered important, but not hazard-related
(e.g., messages relating to property damage).
IMPORTANT SAFETY INSTRUCTIONS
WARNING
Cancer and Reproductive Harm –
www.P65Warnings.ca.gov
DANGER
Generator exhaust contains carbon monoxide, a colorless, odorless, poisonous
gas. Breathing carbon monoxide will cause nausea, dizziness, fainting or
death. If you start to feel dizzy or weak, get to fresh air immediately.
OPERATE GENERATOR OUTDOORS ONLY IN A WELL VENTILATED AREA AND POINT
EXHAUST AWAY.
DO NOT operate the generator inside any building, including garages,
basements, crawlspaces and sheds, enclosure or compartment, including the
generator compartment of a recreational vehicle.
DO NOT allow exhaust fumes to enter a confined area through windows, doors,
vents or other openings.
DANGER
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is a poison you cannot see or
smell.
NEVER use inside a home or garage, EVEN IF doors and windows are open.
ONLY use OUTSIDE and far away from windows, doors, and vents.
Install battery-operated carbon monoxide alarms or plug-in carbon monoxide
alarms with battery back-up according to the manufacturer’s instructions.
DANGER
Tampering with the CO Shield® system will result in a hazardous condition and
will void your warranty. Removing the CO Shield® module will not allow the
generator to start.
DANGER
Operate equipment with guards in place.
Rotating parts can entangle hands, feet, hair, clothing and/or accessories.
Traumatic amputation or severe laceration can result.
Keep hands and feet away from rotating parts.
Tie up long hair and remove jewelry.
DO NOT wear loose-fitting clothing, dangling drawstrings or items that could
become caught.
DANGER
Generator produces powerful voltage.
DO NOT touch bare wires or receptacles.
DO NOT use electrical cords that are worn, damaged or frayed.
Use only Champion electrical cords for proper application.
DO NOT operate generator in wet weather.
DO NOT allow children or unqualified persons to operate or service the
generator.
Use a ground fault circuit interrupter (GFCI) in damp areas and areas
containing conductive material such as metal decking.
Connection to your home’s electrical system requires a listed 30A transfer
switch installed by a licensed electrician and approved by the local authority
having jurisdiction. The connection must isolate the generator from the
utility power and must comply with all applicable laws and electrical codes.
WARNING
Do not use generator for medical and life support uses.
In case of emergency, call 911 immediately.
NEVER use this product to power life support devices or life support
appliances.
NEVER use this product to power medical devices or medical appliances.
Inform your electricity provider immediately if you or anyone in your
household depends on electrical equipment to live.
Inform your electrical provider immediately if a loss of power would cause you
or anyone in your household to experience a medical emergency.
WARNING
Spark from removed spark plug wire can result in fire or electrical shock.
When servicing the generator:
Disconnect the spark plug wire and place it where it cannot contact the plug
or any other metal object.
DO NOT check for spark with the plug removed.
Use only approved spark plug testers.
WARNING
Running engines produce heat. Severe burns can occur on contact. Combustible
material can catch fire on contact.
DO NOT touch hot surfaces.
Avoid contact with hot exhaust gases.
Allow equipment to cool before touching.
Maintain at least 3 ft. (91.4 cm) of clearance on all sides to ensure adequate
cooling.
Maintain at least 5 ft. (1.5 m) of clearance from combustible materials.
WARNING
Rapid retraction of the recoil cord will pull hand and arm towards the engine
faster than you can let go. Broken bones, fractures, bruises or sprains could
result. Unintentional startup can result in entanglement, traumatic amputation
or laceration.
When starting engine, pull the recoil cord slowly until resistance is felt and
then pull rapidly to avoid kickback.
DO NOT start or stop the engine with electrical devices plugged in and turned
on.
WARNING
Although the generator contains a spark arrester, maintain a minimum distance
of 5 ft. (1.5 m) from dry vegetation to prevent fires.
CAUTION
Exceeding the generator’s running capacity can damage the
generator and/or electrical devices connected to it.
DO NOT overload the generator.
DO NOT tamper with the governed speed.
DO NOT modify the generator in any way.
CAUTION
Start the generator and allow the engine to stabilize before connecting
electrical loads.
Connect electrical equipment in the off position, and then turn them on for
operation.
Turn electrical equipment off and disconnect before stopping the generator.
CAUTION
Improper treatment or use of the generator can damage it, shorten its life or
void the warranty.
Use the generator only for intended uses.
Operate only on level surfaces.
DO NOT expose generator to excessive moisture, dust, or dirt.
DO NOT allow any material to block the cooling slots.
If connected devices overheat, turn them off and disconnect them from the
generator.
DO NOT use the generator if:
– Electrical output is lost
– Equipment sparks, smokes or emits flames
– Equipment vibrates excessively
Fuel Safety
GASOLINE AND GASOLINE VAPORS ARE HIGHLY FLAMMABLE AND EXPLOSIVE.
Fire or explosion can cause severe burns or death.
Gasoline and gasoline vapors:
– Gasoline vapors are highly flammable and explosive.
– Gasoline vapors can cause a fire or explosion if ignited.
– Gasoline is a liquid fuel and the resulting gasoline vapors can ignite and
cause a fire or explosion.
– Gasoline is a skin irritant and needs to be cleaned up immediately if
spilled on skin or clothes.
– Gasoline has a distinctive odor, this will help detect potential leaks
quickly.
– In any petroleum gas fire, flames should not be extinguished unless by
doing so the fuel supply valve can be turned OFF. This is because if a fire is
extinguished and a supply of fuel is not turned OFF, then an explosion hazard
could be created.
– Gasoline vapors expand and contract with ambient temperatures. Never fill
the gasoline tank past the red FULL indicator on the fuel filter, as gasoline
vapors needs room to expand if temperatures rise.
WARNING
When adding or removing gasoline:
Do not light or smoke cigarettes.
Always stop the engine and allow to cool for a minimum of two minutes before
refueling.
Always loosen gasoline cap slowly to release vapor pressure and to keep fuel
from escaping around the gasoline cap.
Always replace and tighten the gasoline cap securely after fueling.
Never remove the gasoline cap or add gasoline while the engine is running or
when the engine is hot.
Only fill or drain gasoline outdoors in a well-ventilated area.
Do not pump gasoline directly into the generator at the gas station.
Always store gasoline in an EPA/CARB compliant container or to transfer the
gasoline to the generator.
Do not overfill the gasoline tank.
Always keep gasoline away from sparks, open flames, pilot lights, heat and
other sources of ignition.
WARNING
When starting the generator:
Do not attempt to start a damaged generator.
Always check that the gasoline cap, air filter, spark plug, fuel lines and
exhaust system are properly in place.
Always allow spilled gasoline to evaporate fully before attempting to start
the engine.
Always be certain that the generator is resting firmly on level ground.
WARNING
When operating the generator:
Do not move or tip the generator during operation.
WARNING
When transporting or servicing the generator:
Always check that the fuel valve is in the OFF position and the gasoline tank
is empty.
Disconnect the spark plug wire.
WARNING
When storing the generator:
Store away from sparks, open flames, pilot lights, heat and other sources of
ignition.
Do not store generator or gasoline near furnaces, water heaters, or any other
appliances that produce heat or have automatic ignitions.
DANGER
Never place a gasoline container, gasoline tank, LPG cylinder or any
combustible material in the path of the exhaust stream during operation of the
engine.
WARNING
Never use a gasoline container, gasoline tank, or any other fuel item that is
broken, cut, torn or damaged.
Safety and Dataplate Labels
These labels warn you of potential hazards that can cause serious injury. Read
them carefully.
If a label comes off or becomes hard to read, contact Technical Support Team
for possible replacement.
Safety Symbols
Some of the following symbols may be used on this product. Please study them
and learn their meaning. Proper interpretation of these symbols will allow you
to more safely operate the product.
SYMBOL | MEANING |
---|
|
Read Operator’s Manual. To reduce the risk of injury, user must read and
understand operator’s manual before using this product.
| Clearance. Keep all objects at least 5 feet (1.5m) from generator. Heat
from the muffler and exhaust gas can ignite combustible objects.
| Ground. Consult with local electrician to determine grounding
requirements before operation.
| Electric Shock. Failure to use in dry conditions and to observe safe
practices can result in electric shock. Improper connections to a building can
allow current to backfeed into utility lines, creating an electrocution
hazard. A transfer switch must be used when connecting to a building.
| Fire/Explosion. Fuel and its vapors are extremely flammable and
explosive. Fire or explosion can cause severe burns or death. Keep generator
at least 5 feet (1.5m) from all objects to prevent combustion.
| Hot Surface. To reduce the risk of injury or damage, avoid contact
with any hot surface.
| Open Flame Alert. Fuel and its vapors are extremely flammable and
explosive. Keep fuel away from smoking, open flames, sparks, pilot lights,
heat, and other ignition sources.
| Wet Conditions Alert. Do not expose to rain or use in damp
locations.
Operation Symbols
Some of the following symbols may be used on this product. Please study them
and learn their meaning. Proper interpretation of these symbols will allow you
to more safely operate the product.
SYMBOL | MEANING |
---|---|
On or Run | |
Stop or Off | |
Fuel Off | |
Choke | |
Circuit Breaker Reset: Push | |
Power Output. Percentage of available power from generator being used. | |
Ground Terminal | |
Overload Reset button | |
Low Oil | |
Economy Mode Button | |
Neutral Floating. Neutral circuit IS NOT electrically connected to the |
frame/ ground of the generator.
| 12V Direct Current
| Parallel Connection(s)
| High CO Warning. Move generator to an open, outdoor area. Move to fresh air
and get medical help if sick, dizzy or weak.
| CO Shield System Fault. Electrical issue, end of life.
| Handle Extender Button. Press to extend and collapse handle.
| Fastener Locked Position
| Fastener Unlocked Position
| Push Fastener Before Turning
Quick Start Label Symbols
Some of the following symbols may be used on this product. Please study them
and learn their meaning. Proper interpretation of these symbols will allow you
to more safely operate the product.
Starting the Engine
DANGER
Move generator outside and far away from windows, doors and intake ventilation
covers.
-
Check oil level.
Recommended oil is 10W-30. -
Add fuel. Check gasoline level. When adding gasoline, use a minimum octane rating of 87 and an ethanol content of 10% or less by volume.
-
Move the EZ Start dial to the “CHOKE” position.
-
Pull the recoil cord.
-
Turn the EZ Start dial to gasoline icon for gasoline “RUN”.
-
Plug in desired device.
Stopping the Engine
- Turn off and unplug all connected electrical loads.
- Turn the EZ Start dial to the “STOP” position.
CONTROLS AND fEATURES
Read this operator’s manual before operating your generator. Familiarize
yourself with the location and function of the controls and features. Save
this manual for future reference.
Generator
1. Carrying Handle – Used to lift or carry the unit.
2. Recoil Starter – Used to manually start the engine.
3. Folding Handle – Extendable handle used to move unit by lifting and
rolling on wheels. Do not use to lift or carry the unit.
4. Control Panel – See Control Panel section.| 5. Fuel Cap – Remove to add
fuel.
6. Spark Plug Access Cover
7. Maintenance Cover
8. Muffler
9. Never Flat Wheels – 5.5 in. (14 cm)
---|---
Control Panel
- EZ Start Dial – Used to start, stop and choke the generator.
- Intelligauge – See Intelligauge section.
- CO Shield® LED – The CO Shield® technology monitors for accumulation of poisonous carbon monoxide (CO) gas produced by engine exhaust when the generator is running. If CO Shield® detects elevated levels of CO gas, it automatically shuts off the engine.
- *See CO Shield section for more information 4. AC Overload Reset Button – Used to re-energize receptacles after overload fault. 5. Low Oil Warning Indicator Light – When ON, engine will shut down and not run. Check oil level. 6. Economy Mode Button – Enables/disables automatic idle control. 7. Circuit Breakers (Push Reset) – Protects the generator against electrical overloads. 8. Parallel Outlets – Used to parallel two inverters together for increased power output. (parallel kit sold separately). 9. Ground Terminal – Consult an electrician for local grounding regulations.
RECEPTACLES
A| | 12V DC, 8A (Regulated Automotive)
May be used to supply electrical power for operation of 12 Volt DC, 8 Amp
electrical loads.
B| | (2×) 120V AC, 20A (NEMA 5-20R)
May be used to supply electrical power for operation of 120 Volt AC, 20
Amp, single phase, 60 Hz electrical loads.
WARNING
When charging a device, do not place on the exhaust side of the generator.
Extreme heat caused by exhaust can damage the device and cause a potential
fire hazard. Prolonged exposure to engine exhaust can cause serious injury or
death.
Intelligauge with Power Meter and CO Shield®
Five mode digital meter for displaying voltage, frequency, session run time,
total run time and power output. A. CO Shield® LED – The CO Shield® technology
monitors for accumulation of poisonous carbon monoxide (CO) gas produced by
engine exhaust when the generator is running. If CO Shield® detects elevated
levels of CO gas, it automatically shuts off the engine.
- *See CO Shield section for more information
| MODE| DESCRIPTION
---|---|---
1| Voltage (V)| Output voltage of the generator.
__ Example: 120 volts|
__
2| Frequency (H)| Output frequency in hertz.
__ Example: 60.0 hertz|
__
3| Run Time (R)| Run time of the generator for the current session.
__ Example: 6 hours|
__
__ 4| Total Run Time| Total run time of the generator since first
operation.
__ Example: 16 hours|
__
__ 5| Power Meter| Power Output percentage.
__ Example: 100% Output|
__
FCC Statement
-
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1a. This device may not cause harmful interference.
1b. This device must accept any interference received, including interference that may cause undesired operation. -
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTICE
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
– Consult dealer or an experienced radio/TV technician for help.
Parts Included
Accessories
Dual Port USB Adapter (5v/2.4A) …………………………….1
Engine Oil ……………………………….. 13.5 fl. oz. (400 ml)
Oil Funnel …………………………………………………..1
Spark Plug Socket …………………………………………..1
Assembly Parts
Wheels
5.5 in. (14 cm) Never Flat Wheel (A) ………………………2
Wheel Hub Cap (B) ……………………………………….2
Roll Pin (C) ………………………………………………2
R-clip (D) ………………………………………………..2
Spacer sleeve (E) ………………………………………..2
ASSEMBLY
Your generator requires some assembly. This unit ships from our factory
without oil. It must be properly serviced with fuel and oil before operation.
If you have any questions regarding the assembly of your generator, call our
Technical Support Team at
1-877-338-0999. Please have your serial
number and model number available.
Unpacking
- Set the shipping carton on a solid, flat surface.
- Remove everything from the carton except the generator.
- Using the carrying handles of the unit, carefully remove the generator from the box (two people lifting is recommended).
Install the Wheel Kit
CAUTION
The wheel kit is not intended for over-the-road use.
Install the Wheels
- Before adding fuel and oil, tip the generator onto it’s muffler end.
- Remove wheel hub cap (B) from wheel by inserting a small screwdriver into the slot provided and pry upward.
- Slide the roll pin (C) through the wheel (A) from the outside.
- Slide the wheel (A) through the spacer sleeve (E) from the outside.
- Slide the roll pin through the mount point on the frame.
- Secure with the r-clip (D).
- Re-install hub cap on wheel.
- Repeat to attach the second wheel.
Add Engine Oil
WARNING
DO NOT attempt to crank or start the engine before it has been properly filled
with the recommended type and amount of oil. Damage to the generator as a
result of failing to follow these instructions will void your warranty.
NOTICE
The generator rotor has a sealed, pre-lubricated ball bearing that requires no
additional lubrication for the life of the bearing.
NOTICE
The recommended oil type for typical use is 10W-30 automotive oil. However,
using the listed conventional oils shown in the “Recommended Engine Oil Type”
chart may be used for typical use including the first 5 hours of the break-in
run time period of the engine. If running generator in extreme temperatures,
refer to the “Recommended Engine Oil Type” chart.
-
Place the generator on a flat, level surface.
-
Remove the oil drain side maintenance cover by pushing and turning the two fasteners counterclockwise to the unlocked horizontal position.
-
Remove oil fill cap/dipstick to add oil.
-
Using a funnel(included), add up to 12.9 fl. oz. (380 ml) of oil (included). DO NOT OVERFILL. Replace oil fill cap/dipstick and secure maintenance cover.
-
Check engine oil level before each use and add as needed.
NOTICE
Once oil has been added, a visual check should show oil about 1-2 threads from
running out of the fill hole.
When using the dipstick to check oil level, DO NOT screw in the dipstick while
checking.
NOTICE
Check oil level often during the break-in period. Refer to the Maintenance
section for recommended service intervals.
CAUTION
This engine is equipped with a low oil shut-off and will stop when the oil
level in the crankcase falls below the threshold level.
NOTICE
The first 5 hours of run time are the break-in period for the unit. During the
break in period stay at or below 50% of the running watt rating and vary the
load occasionally to allow stator windings to heat and cool. Adjusting the
load will also cause engine speed to vary slightly and help seat piston rings.
After the 5 hour break-in period, change the oil.
NOTICE
Synthetic oil may be used after the 5 hour initial break-in period. Using
synthetic oil does not decrease the recommended oil change interval. Full
synthetic 5W-30 oil will aid in starting in cold ambient < 41º F (5º C)
temperatures.
Add fuel
DANGER
Gasoline vapors are highly flammable and extremely explosive.
DO NOT light or smoke cigarettes. Fire or explosion can cause severe burns or
death.
Only fill or drain fuel outdoors in a well-ventilated area.
DO NOT pump gasoline directly into the generator. Use an approved container to
transfer the fuel to the generator.
Never use a gasoline container, gasoline tank, or any other fuel item that is
broken, cut, torn or damaged.
DO NOT overfill the gasoline tank. Always keep fuel away from sparks, open
flames, pilot lights, heat and other sources of ignition.
NOTICE
If removing the fuel tank screen, realign the slots on the screen with the
fuel tank vent tube inside the tank neck before reinstalling. Forcing the
screen without realigning slots may cause damage to the generator.
Use clean, fresh, regular unleaded gasoline with a minimum octane rating of 87
and an ethanol content of 10% or less by volume.
DO NOT mix oil with gasoline.
-
Remove the gasoline cap.
-
Slowly add gasoline to the tank. DO NOT OVERFILL. Gasoline can expand after filling. A minimum of ¼ in. (6.4 mm) of space left in the tank is required for gasoline expansion, although more than ¼ in. (6.4 mm) is recommended. Gasolinecan be forced out of the tank as a result of expansion if overfilled, and can affect the stable running condition of the generator.
-
Screw on the gasoline cap and wipe away any spilled fuel.
CAUTION
Use unleaded gasoline with a minimum octane rating of 87 and an ethanol content of 10% or less by volume.
DO NOT light cigarettes or smoke when filling the tank.
DO NOT mix oil and gasoline.
DO NOT overfill the tank. Fill tank to approximately ¼ in.
(6.4 mm) below the top of the tank to allow for gasoline expansion.
DO NOT pump gasoline directly into the generator at the pump.
Use an approved fuel container to transfer the gasoline to the generator.
DO NOT fill tank indoors.
DO NOT fill tank when the engine is running or hot.
WARNING
Pouring gasoline too fast through the fuel screen may result in gasoline splashing over the generator and operator while filling.
NOTICE
The generator engine works well with 10% or less ethanol blended gasoline.
When using ethanol-gasoline blends there are some issues worth noting:
– Ethanol-gasoline blends can absorb more water than gasoline alone.
– These ethanol blends can eventually separate, leaving water or a watery goo
in the tank, fuel valve and carburetor. The compromised gasoline can be drawn
into the carburetor and cause damage to the engine and/or create potential
hazards.
– If a fuel stabilizer is used, confirm that it is formulated to work with
ethanol-gasoline blends.
– Any damages or hazards caused by using ethanol blended gasoline higher than
10% by volume, improperly stored gasoline, and/or improperly formulated
stabilizers, are not covered by manufacturer’s warranty.
It is advisable to always shut off the gasoline supply and run the engine to
starvation after each use. See Storage instructions for extended non-use.
Grounding
Your generator must be properly connected to an appropriate ground to help
prevent electric shock.
WARNING
Failure to properly ground the generator can result in electric shock.
A ground terminal connected to the panel of the generator has been provided
(see Controls and Features for terminal location).
For remote grounding, connect a length of heavy gauge (12 AWG minimum) copper
wire between the generator ground terminal and a copper rod driven into the
ground. We strongly recommend that you consult with a qualified electrician to
ensure compliance with local electrical codes.
**Neutral Floating***
– Neutral circuit IS NOT electrically connected to the frame/ground of the
generator.
– The generator (stator winding) is isolated from the frame and from the AC
receptacle ground pin.
– Electrical devices that require a grounded receptacle pin connection will
not function if the receptacle ground pin is not functional.
**Neutral Bonded to Frame***
– Neutral circuit IS electrically connected to the frame/ground of the
generator.
– The generator system ground connects lower frame crossmember below the
alternator.
The system ground is connected to the AC neutral wire.
- See your Specifications section for specified type of grounding.
OPERATION
CO Shield® – Carbon Monoxide (CO) Detection and Auto-shutoff System CO Shield®
technology monitors the accumulation of carbon monoxide (CO), a poisonous gas
produced by engine exhaust when the generator is running. If CO Shield®
detects unsafe elevated levels of CO gas, it automatically shuts off the
engine. CO SHIELD® IS NOT A SUBSTITUTE FOR AN INDOOR CARBON MONOXIDE ALARM OR
FOR INDOOR OPERATION.
DO NOT allow engine exhaust fumes to enter a confined area through windows,
doors, vents or other openings.
Generators must ALWAYS be used outdoors, far away from occupied buildings with
engine exhaust pointed away from people and buildings.
If misused and operated in an unapproved and unsafe location that results in the accumulation of poisonous CO gas inside an enclosed or partially enclosed space, for example a house, garage or a garage with the door partially open, CO Shield® will automatically shut off the generator and then will illuminate a blinking red LED light. Read the action label for next steps.
In the event of an engine shut off, when you approach the generator to investigate, a blinking red LED light in the CO Shield® area provides notification that the generator shut off due to an accumulating CO hazard. The red LED light will blink for at least five (5) minutes after an engine shut off event.
Move the generator far away to an open, outdoor area and point the exhaust
away from people and buildings. Once relocated to a safe area, the generator
can be restarted, and the proper electrical connections made. Introduce fresh
air and ventilate the location where the generator shut off.
When restarting, the red and yellow LED will blink ten (10) times
simultaneously to indicate the LED is working.
NOTICE
This blinking LED light does not indicate CO Shield® is working, as CO Shield®
is working at all times when the generator is running. Also, the LED light
will not blink (10) times if the generator was restarted within 1 minute after
it was manually shut off. This does not occur if generator shut off from a
high CO event. If CO Shield® system experiences a fault and no longer provides
protection, the generator is shutoff automatically and the yellow LED light
will blink for at least five (5) minutes to notify you of the fault.
Call our Technical Support Team at
1-877-338-0999 for repair.
The generator can be restarted, but will continue to shutoff.
NOTICE
CO Shield® will detect the accumulation of carbon monoxide (CO) from other
fuel burning sources such as engine powered equipment, or propane heaters used
in the area of operation. If another generator is used and the exhaust stream
is pointed at a CO Shield ® equipped generator, the CO Shield® may initiate a
shutoff due to rising carbon monoxide (CO) levels. This is not a fault.
Poisonous carbon monoxide (CO) has been detected. You must take action to move
and direct the generator exhaust stream to better disperse carbon monoxide
(CO) far away from people or buildings.
DANGER
Tampering with the CO Shield® system will result in a hazardous condition and
will void your warranty. Removing the CO Shield® module will not allow the
generator to start.
Generator Location
WARNING
NEVER operate the generator inside any building, garage, basement, crawlspace,
shed, enclosure or compartment, including a generator compartment of a
recreational vehicle. NEVER operate or start the generator in the back of an
SUV, camper, trailer, truck bed (regular sides, flat or other configuration),
under staircases, stairwells, next to walls or buildings or in any other
location that will not allow for adequate cooling of the generator or for the
proper exit of the exhaust flow from the muffler system. DO NOT operate or
store the generator in wet weather conditions such as rain or snow. Using a
generator in wet conditions could result in serious injury or death due to
electrocution. In some state’s generators may be required to be registered
with the local utility company when used at construction sites and may be
subject to additional rules and regulations, consult your local municipal
authority. Generators should always be operated on a flat, level surface at
all times (even when not in operation). Generators must have a minimum of 5
feet (1.5 m) of clearance from all combustible material. Generators must also
have a minimum of 3 feet (91.4 cm) of air flow clearance on all sides to allow
for adequate performance cooling, maintenance and servicing. Always place the
generator in a well-ventilated area. NEVER place the generator near air intake
vents or where exhaust fumes could be drawn into occupied or confined spaces.
Always carefully consider wind and air currents when positioning generator.
Always allow generators to properly cool before transport or for storage
purposes. Failure to follow proper safety precautions may result in personal
injury, damage to the generator and void the manufacturer’s warranty.
WARNING
During operation the muffler and exhaust fumes will become hot. If adequate
cooling and breathing space are not supplied, or if the generator is blocked
or enclosed, temperatures can become extremely heated and may lead to fire.
WARNING
Do not expose to rain or use in damp locations.
Keep all objects a minimum of 5 feet (1.5m) away from the generator at all
times. Heat from the muffler surface and exhaust gas stream can ignite
combustible materials.
WARNING
If you must operate in rain or damp locations, DO NOT operate without proper
protection of the electrical components.
Use of a safety canopy that is fire retardant and will provide proper air
ventilation for the engine exhaust gas stream may be used. Visit
championpowerequipment.com or call to
find your Storm Shield cover.
Surge Protection
Electronic devices, including computers and many programmable appliances use
components that are designed to operate within a narrow voltage range and may
be affected by momentary voltage fluctuations. While there is no way to
prevent voltage fluctuations, you can take steps to protect sensitive
electronic equipment.
– Install UL1449, CSA-listed, plug-in surge suppressors on the outlets feeding
your sensitive equipment. Surge suppressors come in single- or multi-outlet
styles. They’re designed to protect against virtually all short-duration
voltage fluctuations.
Starting the Engine
-
Make certain the generator is on a flat, level surface.
-
Disconnect all electrical loads from the generator. Never start or stop the generator with electrical devices plugged in or turned on.
-
Turn EZ Start dial counter-clockwise to the full “CHOKE” position.
-
Pull the recoil cord slowly until resistance is felt and then pull rapidly.
-
As the engine warms up, move the EZ Start dial to the “RUN” position.
NOTICE
For gasoline restarts with hot engine in hot ambient temperature >86°F (30°C):
Rotate the EZ Start dial to the “CHOKE” position for only one pull of the
recoil cord. If generator does not start after first pull, rotate the dial to
the “RUN” position for the next three pulls. Too much choke leads to spark
plug fouling and engine flooding. This will cause the engine not to start.
NOTICE
For gasoline starting in standard ambient temperature >59°F (15°C): Keep EZ
Start dial in “CHOKE” position for three pulls of the recoil cord. If
generator does not start after three pulls, rotate the EZ Start dial to the
“RUN” position for the next three pulls. Too much choke leads to spark plug
fouling and engine flooding. This will cause the engine not to start.
NOTICE
For gasoline starting in cold ambient temperature < 59°F (15°C): Keep the EZ
Start dial in the “CHOKE” position until engine starts. As soon as the engine
starts and runs smoothly turn the EZ Start dial to the “RUN” position. In
extreme cold temperatures, this may take several seconds.
NOTICE
If the engine starts but does not continue to run make certain that the
generator is on a flat, level surface. The engine is equipped with a low oil
sensor that will prevent the engine from running when the oil level falls
below a critical threshold.
Connecting Electrical Loads
Let the engine stabilize and warm up for a few minutes after starting.
Plug in and turn on the desired 120 or 240 (if applicable) Volt AC single
phase, 60 Hz electrical loads.
– DO NOT connect 3-phase loads to the generator.
– DO NOT overload the generator.
– Use only a high quality, insulated, compatible (3-wire or 4-wire) grounded
cord set rated equal to or greater (volts and amps) than the receptacle
plugging into.
WARNING
Always remember to plug your appliances directly into the generator and do not
plug the generator power cord into any electrical outlet or connect to the
circuit breaker panel in your home. Connecting a generator to your home’s
electric utility company’s power lines, or to another power source, called
‘backfeeding’ is a dangerous practice that is illegal in many states and
municipalities. This action if done incorrectly could damage your generator,
appliances and could cause serious injury or death to you or a utility worker
when attempting to restore power during an outage occurrence in the
neighborhood who may then unexpectedly encounter high voltage on the utility
line and suffer a fatal shock. Whether injuries occur or not, if installed
incorrectly and not to applicable laws and codes, you may be subject to fines
or the utility company may disconnect your home power should this practice be
found in your home. If the generator will be connected to a building
electrical system, those connections must isolate the generator power from the
utility power. You are responsible for ensuring your generator’s electricity
does not backfeed into the electric utility power lines. These connections
must comply with all applicable laws and codes – Consult your local utility
company or a qualified electrician to properly install this connection.
Do Not Overload Generator
Capacity
Follow these simple steps to calculate the running and starting watts
necessary for your purposes:
- Select the electrical devices you plan on running at the same time.
- Total the running watts of these items. This is the amount of power you need to keep your items running.
- Identify the highest starting wattage of all devices identified in step 1. Add this number to the number calculated in step 2. Starting wattage is the surge of power needed to start some electric driven equipment. Following the steps listed under “Power Management” will guarantee that only one device will be starting at a time.
- If the generator power output is cut off due to an overload condition indicated by the AC overload blinking light, lower the load by unplugging one or more items, then press the AC overload reset button before restarting the generator for continued normal operation.
Power Management
Use the following formula to convert voltage and amperage to watts:
Volts × Amps = Watts
To prolong the life of your generator and attached devices, follow these steps
to add electrical load:
- Start the generator with no electrical load attached.
- Allow the engine to run for several minutes to get up to temperature.
- Make sure all circuit breakers are set to the run position.
- Plug in and turn on the first item. It is best to attach the item with the largest load first.
- Allow the engine to stabilize.
- Plug in and turn on the next item.
- Allow the engine to stabilize.
- Repeat steps 5-6 for each additional item.
NOTICE
Never exceed the specified capacity when adding loads to the generator.
Eco (Economy) Mode
The Eco Mode button can be activated to turn on economy control in order to
minimize fuel consumption and noise while operating the unit during times of
reduced electrical output. Eco Mode allows the engine speed to idle during
periods of non-use.
The engine speed returns to normal when an electrical load is connected. When
the economy switch is off, the engine runs at normal speed continuously.
CAUTION
For periods of high electrical load or momentary fluctuations, the Eco Mode
should be off.
Parallel Operation
The Champion model 100571 is parallel ready and can be operated in parallel
with another Champion unit to increase the total available electrical power. A
Champion parallel kit (optional equipment) is required for parallel operation.
Model 100319 is the recommended model for this unit. For a list of compatible
models or to order a parallel kit, please call customer service at
1-877-338-0999 or visit
www.championpowerequipment.com.
Detailed instructions for parallel kit installation and operation of the
connected generators are provided in the parallel kit operator’s manual.
Stopping the Engine
- Turn off and unplug all electrical loads. Never start or stop the generator with electrical devices plugged in or turned on.
- Let the generator run at no-load for several minutes to stabilize internal temperatures of the engine and generator.
- Turn the EZ Start dial clockwise to the “STOP” position.
Important: Always ensure that the EZ Start dial and fuel vent on the fuel
cap are in the “OFF” position when the generator is not in use.
NOTICE
If the generator will not be used for a period of two (2) weeks or longer,
please see the Storage section for proper engine and fuel storage.
Moving the Generator
CAUTION
– NEVER lift or carry the generator using the folding handle.
– NEVER tilt sideways while moving the generator.
– ALWAYS place the generator on its wheels in the upright position.
– ALWAYS turn the generator off and ensure the fuel valve is closed.
– ALWAYS make sure engine and muffler are cooled down before the generator can
be handled safely (typically 15-30 minutes).
WARNING
The folding handle is not long enough to hold and walk with a full stride when
moving the generator. Always side step as you walk to avoid injury to your
heels and/or feet. Failure to follow these instructions could result in
personal injury or damage to the generator.
-
Begin by raising the folding handle, found on opposite side of wheels.
-
Press the button inside the handle as shown below and extend the telescoping handle until a click is heard and the handle is locked in its fully extended position.
-
Using the handle, tilt the end of the generator slightly off the ground until balanced on the wheels.
-
While maintaining balance, roll the generator to the desired location.
Operation at High Altitude
The density of air at high altitudes is lower than at sea level. Engine power
is reduced as the air mass and air-fuel ratio decrease. Engine power and
generator output will be reduced approximately 3½% for every 1000 ft. of
elevation above sea level.
At high altitudes increased exhaust emissions can also result due to the
increased enrichment of the air fuel ratio. Other high altitude issues can
include hard starting, increased fuel consumption and spark plug fouling.
To alleviate high altitude issues other than the natural power loss, CPE can
provide a high altitude carburetor main jet. The alternative main jet and
installation instructions can be obtained by contacting our Technical Support
Team. Installation instructions are also available in the Technical Bulletin
area of the CPE website.
The part number and recommended minimum altitude for the application of the
high altitude carburetor main jet is listed in the following table.
In order to select the correct high altitude main jet it is necessary to
identify the carburetor model. For this purpose, a code is stamped on the side
of the carburetor. Select the correct high altitude jet part number
corresponding to the carburetor code found on your particular carburetor.
Carb. Code| High Alt. Jet Part Number| Min.
Altitude
---|---|---
16100-Z2X0210-00A0| 16161-Z150910-00A1| 3000 ft. (914 m)
16161-Z150610-00A0| 6000 ft. (1829 m)
WARNING
Operation using the alternative main jet at elevations lower than the
recommended minimum altitude can damage the engine. For operation at lower
elevations, the originally supplied standard main jet must be used. Operating
the engine with the wrong engine configuration at a given altitude may
increase its emissions and decrease fuel efficiency and performance.
MAINTENANCE
Make certain that the generator is kept clean and stored properly. Only operate the unit on a flat, level surface in a clean, dry operating environment. DO NOT expose the unit to extreme conditions, excessive dust, dirt, moisture or corrosive vapors.
WARNING
Never operate a damaged or defective generator.
WARNING
Improper maintenance will void your warranty.
NOTICE
For Emission control devices and systems, read and understand your
responsibilities for service as stated in the Emission Control Warranty
Statement of this manual.
The owner/operator is responsible for all periodic maintenance.
Complete all scheduled maintenance in a timely manner.
Correct any issue before operating the generator.
For service or parts assistance, contact our
Technical Support Team at
1-877-338-0999.
Cleaning the Generator
CAUTION
DO NOT spray generator directly with water.
Water can enter the generator through the cooling slots and damage the
generator windings. It can also contaminate the fuel system.
- Use a damp cloth to clean exterior surfaces of the generator.
- Use a soft bristle brush to remove dirt and oil.
- Use an air compressor (25 PSI) to clear dirt and debris from the generator.
- Inspect all air vents and cooling slots to ensure that they are clean and unobstructed.
To prevent accidental starting, remove and ground the spark plug wire before performing any service.
Changing the Engine Oil
Change oil when the engine is warm. Refer to the oil specification to select
the proper grade for your operating environment.
-
Set the generator on top of a work bench or table.
-
Remove the oil drain side maintenance cover by pushing and turning the two fasteners counterclockwise to the unlocked horizontal position.
-
Remove oil fill cap/dipstick.
-
Tilt the generator on its side and allow the oil to drain completely.
-
Add oil according to Add Engine Oil in Assembly section.
DO NOT OVERFILL. Oil not included for routine maintenance. -
Replace oil fill cap/dipstick and secure maintenance cover.
-
Dispose of used oil at an approved waste management facility.
NOTICE
Once oil has been added, a visual check should show oil about 1-2 threads from
running out of the fill hole. If using the dipstick to check oil level, DO NOT
screw in the dipstick while checking.
Cleaning and Adjusting the Spark Plug
-
Remove spark plug access cap from the top panel.
-
Remove the spark plug cable from the spark plug.
-
Use a spark plug socket tool (included), or a 17 mm socket (not included) to remove the plug.
-
Inspect the electrode on the plug. It must be clean and not worn to produce the spark required for ignition.
-
Make certain the spark plug gap is 0.024-0.031 in. (0.6-0.8 mm).
-
Refer to the spark plug types in Specifications when replacing the plug.
-
Firmly re-install the plug.
-
Attach the spark plug cable to the spark plug.
-
Reinstall the spark plug access cap and maintenance cover.
Cleaning the Air filter
-
Remove the oil drain side maintenance cover by pushing and turning the two fasteners counterclockwise to the unlocked horizontal position.
-
Locate the air filter plastic cover and remove.
-
Remove the foam element.
-
Wash in liquid detergent and water. Squeeze thoroughly dry in a clean cloth.
-
Saturate in clean engine oil.
-
Squeeze in a clean, absorbent cloth to remove all excess oil.
-
Place the filter in the assembly.
-
Reattach the air filter cover.
-
Reinstall the maintenance cover.
Cleaning the Spark Arrestor
-
Allow the engine to cool completely before servicing the spark arrestor.
-
Remove the 6 screws holding the cover plate which retains
the spark arrestor to the muffler. -
Remove the spark arrestor screen.
-
Remove the spark arrestor.
-
Carefully remove the carbon deposits from the spark arrestor screen with a wire brush.
-
Replace the spark arrestor if it is damaged.
-
Position the spark arrestor on the muffler and attach with the screws removed in step 2.
CAUTION
Failure to clean the spark arrestor will result in poor engine performance.
NOTICE
Federal and local laws and administrative requirements indicate when and where
spark arrestors are required. When ordered, spark arrestors are required for
operation of this generator in National Forest lands. In California, this
generator must not be used on any forest-covered land, brush-covered land, or
grass-covered land unless the engine is equipped with a spark arrestor.
Adjusting the Governor
WARNING
Tampering with the factory set governor will void your warranty.
The air-fuel mixture is not adjustable. Tampering with the governor can damage
your generator and your electrical devices and will void your warranty.
Contact our Technical Support Team at
1-877-338-0999 for all other service
and/or adjustment needs.
Maintenance Schedule
Follow the service intervals indicated in the following maintenance schedule.
Service your generator more frequently when operating in adverse conditions.
Contact our Technical Support Team at
1-877-338-0999 to locate the nearest
CPE certified service dealer for your generator or engine maintenance needs.
EVERY 8 HOURS OR PRIOR TO EACH USE
- Check oil level
- Clean around air intake and muffler
FIRST 5 HOURS (BREAK IN)
- Change oil
EVERY 50 HOURS OR ANNUALLY
- Clean air filter
- Change oil if operating under heavy load or in hot environments
EVERY 100 HOURS OR ANNUALLY
- Change oil
- Clean/adjust spark plug
- Clean spark arrestor
- Clean fuel valve filter*
EVERY 250 HOURS
- Clean combustion chamber*
- Check/adjust valve clearance*
EVERY 3 YEARS
- Replace fuel line*
- To be performed by knowledgeable, experienced owners or CPE certified service centers.
STORAGE
WARNING
To avoid accidental or unintended ignition of your generator during periods of
storage, the following precautions should be followed:
– When storing the generator make sure the EZ Start dial is set to the “STOP”
position.
Short Term Storage (up to 30 days)
Ethanol blended gasoline in the gasoline tank has a maximum shelf life of up
to 1 year with the addition of properly formulated fuel stabilizers and if
stored in a cool, dry place. Gasoline in the carburetor, however, may gum up
and clog the carburetor if it isn’t used or drained within 2-4 weeks.
If using the generator within 2 weeks, follow the steps according to Stopping
the Engine section.
-
If not using the generator for 2-4 weeks, begin by making sure all appliances are disconnected from the generator.
-
Start the generator as instructed in Starting the Engine section.
-
Turn the EZ Start dial to the RUN OUT OF FUEL position.
-
Let the engine run until fuel starvation has stopped the engine.
-
Turn the EZ Start dial to the “STOP” position
Mid Term Storage (30 days – 1 year)
Ethanol blended gasoline in the tank has a maximum shelf life of up to 1 year
with the addition of a properly formulated fuel stabilizer and stored in a
cool, dry place.
-
Be sure all appliances are disconnected from the generator.
-
Add a properly formulated fuel stabilizer to the gasoline tank.
-
Start engine by following directions in the Starting the Engine section.
-
Run the generator for 10 minutes so the treated gasoline cycles through the fuel system and carburetor.
-
Stop engine by turning the EZ Start dial to the RUN OUT OF FUEL position.
-
After fuel has run out and the engine has stopped, allow the engine to cool.
-
Turn the EZ Start dial to “STOP” position
-
Remove maintenance cover.
-
Remove the spark plug and pour about a tablespoon of oil into the cylinder.
-
SLOWLY pull the recoil to rotate the engine to distribute and lubricate the cylinder.
-
Re-install the spark plug and spark plug wire.
-
Re-install the maintenance cover.
-
Clean the generator according to Cleaning the Generator.
-
Store the generator in a cool, dry place out of direct sunligh
Long Term Storage (more than 1 year)
For storage over 1 year, the gasoline tank and carburetor must be completely
drained of gasoline.
-
Be sure all appliances are disconnected from generator.
-
Place inverter on blocks to allow appropriate gasoline container or pan to slide under inverter.
-
Remove the maintenance cover.
-
Turn the EZ Start dial to the RUN position.
-
Using a Phillips screwdriver, rotate drain screw counterclockwise (3) full turns. Gasoline will drain through clear tubing out underneath the inverter. Make sure draining gasoline empties into an appropriate container.
-
When gasoline stops flowing from the clear tube, rotate drain screw clockwise until tight. Properly dispose of the drained gasoline according to local regulations or guidelines.
-
Turn the EZ Start dial to the “STOP” position.
-
Follow steps 8-14 according to Mid Term Storage.
Removing from Storage
NOTICE
If the generator has been improperly stored for a period longer than 30 days
with ethanol blended gasoline in the gasoline tank and/or carburetor, all fuel
must be drained and the carburetor must be thoroughly cleaned of ethanol build
up. This process involves technically advanced tasks. For assistance please
call our Technical Support Team at
1-877-338-0999.
If the gasoline tank and carburetor were properly emptied of all ethanol
blended gasoline prior to the generator being stored, follow the below steps
when removing from storage.
- Be sure the EZ Start dial is in the “STOP” position.
- Add gasoline to the generator according to Add Fuel: Gasoline.
- Move the EZ Start dial to the “START” position.
- After 5 minutes check the carburetor and air filter areas for any leaking gasoline. If any leaks are found, the carburetor will need to be disassembled and cleaned or replaced. If no gasoline leaks are found, turn the EZ Start dial to the “STOP” position.
- Check engine oil level and add clean, fresh oil if needed. See Oil Specifications for proper oil type.
- Check and clear air filter of any obstructions such as bugs or cobwebs. If necessary, clean air filter according to Cleaning the Air Filter.
- Start the generator according to Starting the Engine.
SPECIFICATIONS
Generator Specifications
Generator Model ……………………………………. 100571
Start Type …………………………………………… Manual
Watts (Starting/Running) ………………………… 3500/2300
AC Volts …………………………………………………. 120
AC Amps @ 120V (Running) …………………………….. 19.2
Volts DC …………………………………………………. 12
DC Amps ……………………………………………………8
Frequency ……………………………………………..60 Hz
Phase ………………………………………………… Single
Grounding Type ……………………………….Neutral Floating
Weight …………………………………….. 57.8 lb. (26.2 kg)
Length ……………………………………. 23.8 in. (60.5 cm)
Width …………………………………….. 16.4 in. (41.6 cm)
Height ………………………………………19.4 in. (49.4 cm)
Engine Specifications
Model ………………………………………………. R120-Vi
Displacement ………………………………………….122 cc
Type …………………………………………… 4-Stroke OHV
Spark Plug
OEM Type ……………………………………………..A5RTC
Replacement Type ………………… NGK CR6HSA or equivalent
Gap …………………………… 0.024-0.031 in. (0.6-0.8 mm)
Valve
Intake Clearance ……………..0.002-0.006 in. (0.05-0.15 mm)
Exhaust Clearance ……………0.002-0.006 in. (0.05-0.15 mm)
NOTICE
A technical bulletin regarding valve adjustment procedures is available at
www.championpowerequipment.com.
Oil Specifications
DO NOT OVERFILL.
Type ……………………………………..*See following chart
Capacity ………………………………… 12.9 fl. oz. (380 ml)
NOTICE
Temperature will affect engine oil and engine performance.
Change the type of engine oil used based on temperature shown in the
“Recommended Engine Oil Type” table.
Fuel Specifications
Use unleaded gasoline with a minimum octane rating of 87 and an ethanol
content of 10% or less by volume. DO NOT USE E15 or E85. DO NOT OVERFILL.
Gasoline Capacity ………………………….. 1.2 gal. (4.500 L)
Temperature Specifications
Starting Temperature Range (°F/°C) ……….. 5 to 104/-15 to 40
NOTICE
An important message about temperature: Your product s designed and rated for
continuous operation at ambient emperatures up to 104°F (40°C). When needed,
it may be operated at temperatures ranging from 5°F (-15°C) to 122°F 50°C) for
short periods of time. If exposed to temperatures outside this range during
storage, it should be brought back within this range before operation. In any
event, the product must always be operated outdoors, in a well-ventilated area
and away from doors, windows and vents.
TROUBLESHOOTING
Problem | Cause | Solution |
---|
Engine will not start.
| No fuel.| Add fuel.
Faulty spark plug.| Clean and adjust spark plug or replace.
Low oil level.| Fill crankcase to the proper level.
Place generator on a flat, level surface.
Spark plug wire loose.| Attach wire to spark plug.
Fuel valve is closed.| Open fuel valve.
EZ Start dial OFF.| Turn EZ Start dial ON.
Old fuel or water in fuel.| Drain fuel and replace with fresh fuel.
Flooded with fuel.| Let unit stand for 10 mins.
CO Shield® module has been removed or tampered with.| Re-install module or
contact technical support.
Engine starts but runs roughly.
| Choke in the wrong position.| Move EZ Start Dial to the RUN position.
Dirty air filter.| Clean or replace air filter.
Dirty fuel valve.| Clean the fuel valve.
Clogged spark arrestor.| Clean spark arrestor.
Engine shuts down during operation.
| Out of fuel.| Fill fuel tank.
Low oil level.| Fill crankcase to the proper level. Place generator on a flat,
level surface.
If equipped, when CO Shield® shutoffs occur due to accumulating carbon monoxide (CO) and if the red LED light blinks on the panel.
| Move generator to an open, outdoor area. Point exhaust away from people and buildings. Move to fresh air and get medical help if sick, dizzy, or weak.
Make sure there are no objects creating obstructions within 5 feet of the
generator. Obstructions in the vicinity of the generator may trap carbon
monoxide emissions near the generator and cause the engine to shutoff.
If the generator’s exhaust is facing into the wind, the exhaust may be blown
back into the generator’s operating area, creating an accumulation of CO
emissions and triggering an engine shutoff. To avoid an engine shutoff, turn
the generator 45° in either direction to allow the exhaust emissions to blow
away from the generator. If engine shutoff events continue, readjust and align
the exhaust with the wind direction to blow away from the generator.
If equipped, when CO Shield® shutoffs occur due to system fault and if the
yellow LED light blinks on the panel.| Start by confirming yellow LED light
blinks when/ if generator shuts off. If CO Shield continues to sense the fault
and shuts off, contact technical support.
Clogged spark arrestor.| Clean spark arrestor.
Problem| Cause| Solution
---|---|---
Engine starts and shuts off right away.
| ****
If equipped, when CO Shield® shutoffs occur due to accumulating carbon monoxide (CO) and if the red LED light blinks on the panel.
| Move generator to an open, outdoor area. Point exhaust away from people and buildings. Move to fresh air and get medical help if sick, dizzy, or weak.
Make sure there are no objects creating obstructions within 5 feet of the generator. Obstructions in the vicinity of the generator may trap carbon monoxide emissions near the generator and cause the engine to shutoff.
If the generator’s exhaust is facing into the wind, the exhaust may be blown back into the generator’s operating area, creating an
accumulation of CO emissions and triggering an engine shutoff. To avoid an engine shutoff, turn the generator 45° in either direction to allow the exhaust emissions to blow away from the generator. If engine shutoff events continue, readjust and align the exhaust with the wind
direction to blow away from the generator.
If equipped, when CO Shield® shutoffs occur due to system fault and if the
yellow LED light blinks on the panel.| Start by confirming yellow LED light
blinks when/ if generator shuts off. If CO Shield® continues to sense the
fault and shuts off, contact technical support.
Both CO Shield® LEDs not blinking 10 times upon start up.| Starting the
generator within 1 minute after being manually shutoff, not a CO shutoff
event.| Wait 1 minute before trying to restart the generator. The LEDs should
then blink ten (10) times.
Generator cannot supply enough power or overheating.| Generator is
overloaded.| Review load and adjust. See “Connecting Electrical Loads.”
Dirty air filter.| Clean or replace air filter.
Choke in wrong position.| Move EZ Start Dial to the RUN position.
Engine is running but no AC output.| Poor cord connection.| Check all
connections.
Circuit breaker is open.| Reset circuit breaker. Check all circuit breakers.
Loose wiring.| Inspect and tighten wiring connections.
AC Overload: Button illuminated red| Reduce AC load and press Overload Reset
Button until illuminated green.
Other.| Contact the help line.
Problem| Cause| Solution
---|---|---
Engine hunts or falters.| Engine governor defective.| Contact the help
line.
Dirty fuel valve.| Clean the fuel valve.
Carburetor is dirty and running lean.| Contact the help line.
Choke in wrong position.| Move EZ Start Dial to the RUN position.
Repeated circuit breaker tripping.| Overload.| Review load and adjust.
See “Connecting Electrical Loads.”
Faulty power cords or device.| Check for damaged, bare or frayed wires.
Replace defective device.
Circuit breaker still too hot.| Let unit sit for 5 mins.
For other issues and technical support:
Technical Support Team
Toll Free 1-877-338-0999
support@championpowerequipment.com
WARRANTY
**WARRANTY***
CHAMPION POWER EQUIPMENT
3 YEAR LIMITED WARRANTY
Warranty Qualifications
To register your product for warranty and FREE lifetime call center technical
support please visit:
https://www.championpowerequipment.com/register
To complete registration you will need to include a copy of the purchase
receipt as proof of original purchase. Proof of purchase is required for
warranty service. Please register within ten (10) days from date of purchase.
Repair/Replacement Warranty
CPE warrants to the original purchaser that the mechanical and electrical
components will be free of defects in material and workmanship for a period of
three years (parts and labor) from the original date of purchase and 270 days
(parts and labor) for commercial and industrial use. Transportation charges
on product submitted for repair or replacement under this warranty are the
sole responsibility of the purchaser. This warranty only applies to the
original purchaser and is not transferable.
Do Not Return The Unit To The Place Of Purchase
Contact CPE’s Technical Service and CPE will troubleshoot any issue via phone
or e-mail. If the problem is not corrected by this method, CPE will, at its
option, authorize evaluation, repair or replacement of the defective part or
component at a CPE Service Center. CPE will provide you with a case number for
warranty service. Please keep it for future reference. Repairs or replacements
without prior authorization, or at an unauthorized repair facility, will not
be covered by this warranty.
Warranty Exclusions
This warranty does not cover the following repairs and equipment:
Normal Wear
Products with mechanical and electrical components need periodic parts and
service to perform well. This warranty does not cover repair when normal use
has exhausted the life of a part or the equipment as a whole.
Installation, Use and Maintenance
This warranty will not apply to parts and/or labor if the product is deemed to
have been misused, neglected, involved in an accident, abused, loaded beyond
the product’s limits, modified, installed improperly or connected incorrectly
to any electrical component.
Normal maintenance is not covered by this warranty and is not required to be
performed at a facility or by a person authorized by CPE.
Other Exclusions
This warranty excludes:
– Cosmetic defects such as paint, decals, etc.
– Wear items such as filter elements, o-rings, etc.
– Accessory parts such as starting batteries, and storage covers.
– Failures due to acts of God and other force majeure events beyond the
manufacturer’s control.
– Problems caused by parts that are not original Champion Power Equipment
parts.
When applicable, this warranty does not apply to products used for prime power
in place of a utility.
Limits of Implied Warranty and
Consequential Damage
Champion Power Equipment disclaims any obligation to cover any loss of time,
use of this product, freight, or any incidental or consequential claim by
anyone from using this product.
THIS WARRANTY AND THE ATTACHED U.S. EPA and/or CARB EMISSION CONTROL SYSTEM
WARRANTIES (WHEN APPLICABLE) ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE.
A unit provided as an exchange will be subject to the warranty of the original
unit. The length of the warranty governing the exchanged unit will remain
calculated by reference to the purchase date of the original unit.
This warranty gives you certain legal rights which may change from state to
state or province to province. Your state or province may also have other
rights you may be entitled to that are not listed within this warranty.
Contact Information
Address
Champion Power Equipment, Inc.
12039 Smith Ave.
Santa Fe Springs, CA 90670 USA
www.championpowerequipment.com
Customer Service
Toll Free: 1-877-338-0999
info@championpowerequipment.com
Fax no.: 1-562-236-9429
Technical Service
Toll Free: 1-877-338-0999
tech@championpowerequipment.com
EMERGENCY 24 HOUR SUPPORT:
1-562-204-1188
*Except as otherwise stipulated in any of the following enclosed Emission Control System Warranties (when applicable) for the Emission Control System: U.S. Environment Protection Agency (EPA) and/or California Air Resources Board (CARB). Whichever warranty applies for the longer period, either this 3 year limited warranty or the applicable Emission Control System Warranty, shall supersede the other.
CHAMPION POWER EQUIPMENT, INC. (CPE)
AND THE UNITED STATES ENVIRONMENTAL PROTECTION AGENCY (U.S. EPA)
EMISSION CONTROL SYSTEM WARRANTY
Your Champion Power Equipment (CPE) engine complies with U.S. EPA emissions
regulations.
YOUR WARRANTY RIGHTS AND OBLIGATIONS:
The US EPA and CPE are pleased to explain the Federal Emission Control Systems
Warranty on your 2023 small off-road engine (SORE) and engine powered
equipment. New engines and equipment must be designed, built and equipped, at
the time of sale, to meet U.S. EPA regulations for small off-road engines
(SORE). CPE warrants the emission control system on your small off-road engine
(SORE) and equipment for the period of time listed below, provided there has
been no abuse, neglect, unapproved modification, or improper maintenance of
your equipment.
Your emission control system may include parts such as the carburetor, fuel-
injection system, the ignition system, catalytic converter and fuel lines.
Also included may be hoses, belts, connectors and other emission related
assemblies. Where a warrantable condition exits, CPE will repair your small
off-road engine (SORE) at no cost to you including diagnosis, parts and labor.
MANUFACTURER’S EMISSION CONTROL SYSTEM WARRANTY COVERAGE:
This emission control system is warranted for two years, subject to provisions
set forth below. If, during the warranty period, an emission related part on
your engine is defective in materials or workmanship, the part will be
repaired or replaced by CPE.
OWNER WARRANTY RESPONSIBILITIES:
As the small off-road engine (SORE) owner, you are responsible for the
performance of the required maintenance listed in your Owner’s Manual. CPE
recommends that you retain all your receipts covering maintenance on your
small off-road engine, but CPE cannot deny warranty solely for the lack of
receipts or for your failure to ensure the performance of all scheduled
maintenance.
As the small off-road engine (SORE) owner, you should however be aware that
CPE may deny you warranty coverage if your small, off-road engine (SORE) or a
part has failed due to abuse, neglect, improper maintenance or unapproved
modifications.
You are responsible for presenting your small off-road engine (SORE) to an
Authorized CPE service outlet or alternate service outlet as described in
(3)(f.) below, CPE dealer or CPE, Santa Fe Springs, Ca. as soon as a problem
exists. The warranty repairs should be completed in a reasonable amount of
time, not to exceed 30 days.
If you have any questions regarding your warranty rights and responsibilities,
you should contact:
Champion Power Equipment, Inc.
Customer Service
12039 Smith Ave.
Santa Fe Springs, CA 90670
1-877-338-0999
tech@championpowerequipment.com
EMISSION CONTROL SYSTEM WARRANTY
The following are specific provisions relative to your Emission Control System
(ECS) Warranty Coverage.
- APPLICABILITY: This warranty shall apply to 1997 and later model year small off-road engines (SORE). The ECS Warranty Period shall begin on the date the new engine or equipment is delivered to its original, end-use purchaser, and shall continue for 24 consecutive months thereafter.
- GENERAL EMISSIONS WARRANTY COVERAGE CPE warrants to the original, end-use purchaser of the new engine or equipment and to each subsequent purchaser that each of its small off-road engines (SORE) is: 2a. Designed, built and equipped so as to conform to U.S. EPA emissions standards for spark-ignited engines at or below 19 kilowatts. 2b. Free from defects in materials and workmanship that cause the failure of a warranted part to be identical in all material respects to the part as described in the engine manufacturer’s application for certification for a period of two years.
- THE WARRANTY ON EMISSION-RELATED PARTS WILL BE INTERPRETED AS FOLLOWS:
3a. Any warranted part that is not scheduled for replacement as required maintenance in the Owners Manual shall be warranted for the ECS Warranty Period. If any such part fails during the ECS Warranty Period, it shall be repaired or replaced by CPE according to Subsection “d” below. Any such part repaired or replaced under the ECS Warranty shall be warranted for any remainder of the ECS Warranty Period.
3b. Any warranted, emissions-related part which is scheduled only for regular inspection as specified in the Owners Manual shall be warranted for the ECS Warranty Period. A statement in such written instructions to the effect of “repair or replace as necessary”, shall not reduce the ECS Warranty Period. Any such part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period.
3c. Any warranted, emissions-related part which is scheduled for replacement as required maintenance in the Owner’s Manual shall be warranted for the period of time prior to the first scheduled replacement point for that part. If the part fails prior to the first scheduled replacement, the part shall be repaired or replaced by CPE according to Subsection “d” below. Any such emissionsrelated part repaired or replaced under the ECS Warranty, shall be warranted for the remainder of the ECS Warranty Period prior to the first scheduled replacement point for such emissions-related part.
3d. Repair or replacement of any warranted, emissions-related part under this ECS Warranty shall be performed at no charge to the owner at a CPE Authorized Service Outlet.
3e. The owner shall not be charged for diagnostic labor which leads to the determination that a part covered by the ECS Warranty is in fact defective, provided that such diagnostic work is performed at a CPE Authorized Service Outlet.
3f. CPE shall pay for covered emissions warranty repairs at non-authorized service outlets under the following circumstances:
3i. The service is required in a population center with a population over 100,000 according to U.S. Census 2000 without a CPE Authorized Service Outlet AND
ii. The service is required more than 100 miles from a CPE Authorized Service Outlet. The 100 mile limitation does not apply in the following states: Alaska, Arizona, Colorado, Hawaii, Idaho, Montana, Nebraska, Nevada, New Mexico, Oregon, Texas, Utah and Wyoming.
3g. CPE shall be liable for damages to other original engine components or approved modifications proximately caused by a failure under warranty of an emission-related part covered by the ECS Warranty.
3h. Throughout the ECS Warranty Period, CPE shall maintain a supply of warranted emission-related parts sufficient to meet the expected demand for such emission-related parts. 3i. Any CPE Authorized and approved emission- related replacement part may be used in the performance of any ECS Warranty maintenance or repair and will be provided without charge to the owner. Such use shall not reduce CPE’s warranty obligation.
3j. Unapproved add-on or modified parts may not be used to modify or repair a CPE engine. Such use voids this ECS Warranty and shall be sufficient grounds for disallowing an ECS Warranty claim. CPE shall not be liable hereunder for failures of any warranted parts of a CPE engine caused by the use of such an unapproved add-on or modified part.
EMISSION-RELATED PARTS INCLUDE THE FOLLOWING: (using those portions of the list applicable to the engine)
Systems covered by this warranty | Parts Description |
---|---|
Fuel Metering System | Fuel regulator, Carburetor and internal parts |
Air Induction System | Air cleaner, Intake manifold |
Ignition System | Spark plug and parts, Magneto ignition system |
Exhaust System | Exhaust manifold, catalytic converter |
Miscellaneous Parts | Tubing, Fittings, Seals, Gaskets, and Clamps associated |
with these listed systems.
Evaporative Emissions| Fuel Tank, Fuel Cap, Fuel Lines (for liquid fuel and
fuel vapors), Fuel Line Fittings, Clamps, Pressure Relief Valves, Control
Valves, Control Solenoids, Electronic Controls, Vacuum Control Diaphragms,
Control Cables, Control Linkages, Purge Valves, Gaskets, Liquid/Vapor
Separator, Carbon Canister, Canister Mounting Brackets, Carburetor Purge Port
Connector
TO OBTAIN WARRANTY SERVICE:
You must take your CPE engine or the product on which it is installed, along
with your warranty registration card or other proof of original purchase date,
at your expense, to any Champion Power Equipment dealer who is authorized by
Champion Power Equipment, Inc. to sell and service that CPE product during his
normal business hours. Alternate service locations defined in Section (3)(f.)
above must be approved by CPE prior to service. Claims for repair or
adjustment found to be caused solely by defects in material or workmanship
will not be denied because the engine was not properly maintained and used.
If you have any questions regarding your warranty rights and responsibilities,
or to obtain warranty service, please write or call Customer Service at
Champion Power Equipment, Inc.
Champion Power Equipment, Inc.
12039 Smith Ave.
Santa Fe Springs, CA 90670
1-877-338-0999
Attn.: Customer Service
tech@championpowerequipment.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>