Haier QPCA08 Btu Portable Air Conditioner User Manual

June 15, 2024
Haier

Haier QPCA08 Btu Portable Air Conditioner User Manual
Haier QPCA08 Btu Portable Air Conditioner

SAFETY INFORMATION

WARNING
For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.

  • Use this appliance only for its intended purpose as described in this Owner’s Manual.
  • This air conditioner must be properly installed in accordance with the Installation Instructions before it is used.
  • Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle.
  • Replace immediately all electric service cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.
  • Turn the unit OFF and unplug your air conditioner before cleaning.
  • For your safety…do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
  • If the receptacle does not match the plug, the receptacle must be changed out by a qualified electrician.

CONTROLS

Features and appearance will vary. Lights next to the touch pads on the air conditioner control panel indicate the selected settings.

Product Overview

NOTE: When the machine is powered on for the first time, the buzzer will play power-on music and then the machine will go into standby status.

  1. Power Button
    Turns ON/OFF power to the air conditioner.
    NOTE: Turning off power by pressing the Power button does NOT disconnect the appliance from power supply.
    Press the Power button. The power indicator and  temperature display will illuminate, select desired settings. After one minute, the display lights will turn off. Press any button on the unit or the remote. The display will illuminate. Then press corresponding buttons to change unit function.
    Note: If changes functions from the remote, it may required multiple button pushes to synchronize remote to the unit.

  2. Mode Button
    Press the Mode button to toggle among the operating options. The corresponding indicator will illuminate:
    Cool – Cools the room to the set temperature
    DRY – Reduces the humidity in the room
    Fan – Circulates the air in the room without cooling

  3. + and – Buttons
    Sets the Temperature when in Cooling Mode or sets the Time when Timer is selected.
    To Set the Temperature:
    Press the + or – button to select the required temperature.
    NOTE: The temperature cannot be set when the air conditioner is in either Fan or DRY mode. To Set the Time:
    Press the + or – button to select the required time.

  4. Fan Speed Button
    The fan speed can be adjusted from Low to High speed when the air conditioner is in operation.
    NOTE: The fan speed cannot be adjusted when the unit is in DRY mode.

  5. Timer Button
    Program a time from (1 hour to 24 hours) for the air conditioner to turn Off or On.

  6. Sleep Mode
    Press the Sleep button to turn on Sleep Mode.

NOTE: You cannot turn on the Sleep mode in the Dry or FanMode.

NOTE: When the inner unit chassis is full of water, the Water Full light will turn on. A buzzer will sound for several seconds and the compressor will stop.

Refer to the instructions on page 6 for draining the water from the unit.

The display will always default to show SET temperature. When the air conditioner is turned on, it will automatically start in the last mode and fan settings selected

FROST PROTECTION FUNCTION:

In cooling or dry mode, if the temperature of the exhaust hose is too low, the AC will automatically go into a unit protection state.

When the temperature rises to a normal temperature, the unit will automatically resume normal operation.

OVERFLOW PROTECTION FUNCTION:

When water in the water pan exceeds the warning level, the machine will automatically sound an alarm, the FULL indicator light will flash and the unit will shut down. At this point, you need to drain the water from the lower drain (See Drainage instructions for details)

After the water is emptied, the machine the machine will automatically resume normal operation.

AUTOMATIC DEFROSTING (on some models)

The machine has an automatic defrosting function.

PROTECTION FUNCTION OF THE COMPRESSOR

To increase the service life of the compressor, the AC has a 3-minute delay after the compressor has shut off to protect the compressor.

DRAINAGE INSTRUCTIONS

Draining the unit manually:

Note: Please move the AC carefully, do not spill the water in the water pan at the bottom of the unit.

  1. When the AC stops after the water is full, turn off the AC power and unplug the power plug.

  2. Place a water container larger than the sump capacity (at least 1-1/2 quart) below the lower rear water outlet on the back side of unit.

  3. Remove the plug, the water will automatically flow into the container.
    Note: During drainage, the body can be tilted slightly backwards. If the water container cannot hold all the water, before the water container is full, replace the water plug as soon as possible to prevent water from flowing to the floor or the carpet.

  4. After water has been drained from the unit, re-install the water plug securely

Note: Restart the AC after the water plug is installed, otherwise condensate water from the AC will drain onto the floor or carpet.

Continuous drainage (optional, and only in dry mode)

  1. Remove the upper drain plug.
  2. Connect a drain hose with an inside diameter of 5/8” to the water outlet.
  3. Route drain hose to a bucket or floor drain.
  4. Be sure to use a large container (3 gallons or larger is recommended) and monitor the water level in the container continuously. The unit will not shut off when the container is full. An overflowing container can cause flooding and damage to the floor.
    Drainage Instruction

Features and appearance may vary. Icons on the remote control indicate the selected settings

Product Overview

REMOTE CONTROL

  1. Insert the two AAA batteries (provided).
  2. Aim the remote control at the signal receiver on the control panel to operate the air conditioner.
    A. Power Button
    Turns ON/OFF power to the air conditioner.
    B. Mode Button
    Press the Mode button to toggle among the operating options, cooling, fan and dry mode.
    C. + and – Button
    Adjusts the Temperature or Timing set value.
    D. Fan Button
    Press the Fan button to adjust fan speed from Low to High speed.
    E. Timer
    Press Timer button to activate the ON/OFF timer. Use the + and – buttons to adjust the timer.
    F. Sleep Button
    Press the Sleep button to turn on the sleep mode.

Note: The air conditioner LED display will turn off 1 minute after last button is pushed. To turn on the LED display, press any button on the unit or the remote. Then press corresponding function to change settings, the remote may require multiple pushes to synchronize the unit.

CARE AND CLEANING

CLEANING

WARNING

Electrical Shock Hazard
Disconnect power before cleaning.

  1. Unplug or disconnect power.

  2. Use only a soft cloth dampened with water to clean the cabinet.
    NOTE:

  3. Do not use a liquid or spray cleaner to clean the air conditioner.

  4. DO NOT use chemicals, abrasives, ammonia, chlorine bleach, concentrated detergents, solvents or scouring pads. Some of these chemicals/items may damage and/or discolor your air conditioner.

  5. Dry thoroughly with a soft cloth.

  6. Plug in or reconnect power.

CLEANING THE SURFACE

Clean surface of machine with a wet soft cloth. Do not use chemicals, such as benzene, alcohol, gasoline, etc.; otherwise, the surface of the air conditioner will be damaged or the entire unit will be damaged.

AIR FILTER

The air filters should be cleaned at least every two weeks for your unit to operate at optimum efficiency.

CAUTION
DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance.

To clean the upper filter screen frame:

  1. Remove the upper and lower filter screens. On the top filter, place finger in recess at top of filter and pull down and outward to remove. On the lower filter, place finger in recess at bottom of filter, pull upward and outward to remove filter.
  2. Remove the filter from the filter frame. It is held in place by 4 tabs. After removal, wash or vacuum the filter to remove the dirt and lint. Make sure filter is dry before reinstalling on the unit.
    Installation Instruction

STORAGE

If the unit is not being used for a long period of time:

To Empty the Internal Water Tank:

  1. Unplug or disconnect power.
  2. Drain the water from the water tank. (See “Internal Water Tank section” above.)
  3. Use the original packaging to repack the unit to avoid a buildup of dust or dirt.
  4. Store the air conditioner in a cool, dry location.

INSTALLATION INSTRUCTIONS

Questions? Call GE Appliances at 866.907.1655 or visit our Website at: GEAppliances.com.

BEFORE YOU BEGIN

Read these instructions completely and carefully.

  • IMPORTANT — Save these instructions for local inspector’s use.
  • IMPORTANT — Observe all governing codes and ordinances.
  • Note to Installer – Be sure to leave these instructions with the Consumer.
  • Note to Consumer – Keep these instructions for future reference.
  • Skill level – Installation of this appliance requires basic mechanical skills.
  • Completion time – Approximately 1 hour
  • We recommend two people to install this product.
  • Proper installation is the responsibility of the installer.
  • Product failure due to improper installation is not covered under the Warranty.
  • You MUST use all supplied parts and use proper installation procedures as described in these instructions when installing this air conditioner.

ELECTRICAL REQUIREMENTS

These models require a 115/120-volt AC, 11) 60-Hz grounded outlet protected with a 15-amp time-delay fuse or circuit breaker. The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.

CAUTION

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.

Do not change the plug on the power cord of this air conditioner.

Aluminium house wiring may present special problems- consult a qualified electrician.

Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
Product Overview

LOCATION REQUIREMENTS

  • Place the air conditioner on a flat, level surface. For optimal performance place portable 20″ from exterior wall. For all other sides a minimum distance of 30″ should be maintained.
  • Keep the air conditioner free of any obstructions such as drapes, curtains, blinds, etc.
  • The exhaust hose should be free of any obstructions.
  • Do not place the air conditioner on an unstable or raised surface because it could fall and cause damage or injury.
  • Do not place the air conditioner in direct sunlight or near a heat source such as baseboard heaters, stoves, etc.
  • The window panel can be installed in a window with a minimum 20″ (55.88 cm) to a maximum 46″ (121.92) opening.
    Product Overview

PARTS INCLUDED

(Appearance may vary)
Product Overview

  1. Top Cover
  2. Control Panel
  3. Side Panel
  4. Air Outlet / Louver
  5. Front Housing
  6. Rear Housing
  7. Caster
  8. Base Pan
  9. Upper Filter
  10. Upper Continuous Drain
  11. Cord Wrapping Post
  12. Exhaust Air Vent
  13. Lower Filter
  14. Lower Drain
  • Exhaust Hose Assembly
    Parts

  • Top Window Bracket (2)

  • Bottom Window Bracket (2)

  • Security Bracket

  • Top Foam Strip

  • Bottom Foam Strip

  • Foam Strip

  • Remote Control Batteries (2)

  • Window Mounting Kit
    Parts

  • Flat Tip Screw For exhaust nozzle to main window panel.

  • Pointed Screws (7)

2 – Top Window Bracket
1 – Security Bracket
4 – Main Window Pane

TOOLS YOU WILL NEED
Parts

WINDOW PANEL COMBINATIONS TO FIT WINDOW OPENINGS (Appearance may vary)

  • Window Opening 20” – Center Panel Only
    Installation Instruction

  • Window Opening 20”- 23½” – Center Panel + 5½” Extension
    Installation Instruction

  • Window Opening 23½”- 27” – Center Panel + 9” Extension
    Installation Instruction

  • Window Opening 23½”- 30½” – Center Panel + 9” and 5½” Extensions
    Installation Instruction

  • Window Opening 30½” – 34” – Center Panel + 16” Extension
    Installation Instruction

  • Window Opening 34”- 41” – Center Panel + 9” and 16” Extensions
    Installation Instruction

  • Window Opening 41”- 48” – Center Panel + (2) 16” Extensions
    Installation Instruction

UNPACK AIR CONDITIONER

WARNING

Excessive Weight Hazard

  • Use two or more people to move and install air conditioner.
  • Failure to do so can result in back or other injury.

NOTE: Before using the air conditioner, keep it upright for at least 2 hours.

  • Remove packaging materials. Save the carton and the foam packaging for storing the air conditioner when not in use.
    NOTE: There are NO packing materials inside the air conditioner to remove—Do Not open the cabinet.

  • Properly dispose of/recycle all packing material.

  • Handle the air conditioner gently.

  • Keep the air conditioner upright and level. Do not set the air conditioner on its side, front, back or upside down.

INSTALL EXHAUST NOZZLE TO MAIN WINDOW PANEL

  1. Hold the main window panel so that the L-shaped edges of the panel are facing you.

  2. Align the exhaust nozzle with the slots in the opening, and then insert and slide the nozzle to access the hole from the back of the main window panel.

  3. Turn the main window panel over, so that the nozzle is away from you. Insert a flat tip screw through the hole to fasten the window panel to the adapter.

INSTALL MAIN WINDOW PANEL AND EXTENSION PANELS

NOTE: Measure the window opening and use the extension panels as referenced on page 10 to fit your window.

  1. Open the window and place the window kit assembly into the window.
    NOTE: The window assembly is designed to accommodate either a double hung or sliding window.
    Installation Instruction

  2. Adjust the extension panel(s) to the width or height of the window as shown.

  3. Depending on the number of extension panels used, turn the knobs to secure the extension panel(s) to the main panel. Install from the back.

NOTE: There are many window types on the market today. Use the foam strips and brackets (provided) to secure the extension panels that will fit the window opening.

  1. For vinyl windows only.
    Skip to step 6 for wood windows. Place the two top window brackets and two bottom window brackets where they will best support the extension panels. Use painted screws to attach top bracket to the support panels.
    Installation Instruction
    Installation Instruction

  2. Apply the top foam strip (provided) across the top of the window panel assembly, and then apply the bottom foam strip (provided) across the bottom front edge of the window panel assembly, as shown.
    Installation Instruction

  3. Place the window panel assembly in the window, and using the screws provided, fasten the assembly to the window sill and window frame.
    Installation Instruction

  4. Using one pointed screw, install the Security bracket to the window.
    NOTE: The security bracket prevents the window from being opened from the outside.
    Installation Instruction

Attach Exhaust Hose to the Exhaust Nozzle

  1. Grasp both ends of the exhaust hose and gently pull to expand fully the ends of the hose. Note: Do not attach multiple hoses to extend the length, this would decrease the cooling efficiency and may cause damage to the air conditioner.
  2. Turn hose clockwise and screw into the nozzle in the window panel. Attach adapter to other end of hose by turning clockwise.

CONNECT EXHAUST HOSE TO THE AIR CONDITIONER

NOTE: When connecting the hose, the air conditioner must be close enough to the window that you will not dislodge the window seal plate. Once the hose is connected, move the air conditioner 20” (51 cm) from the wall.

  1. Extend the flexible exhaust hose to reach out to the unit.
  2. Aim the opening of the hose to the air exhaust outlet and push it hard straight into the outlet until it clicks.
    Installation Instruction

TROUBLESHOOTING TIPS

Problem Possible Causes Solution
Unit does not start or operate Power supply cord is
not plugged into an outlet. Plug the power cord into a grounded 3 prong

outlet.
Power supply cord has tripped.| Press and release the RESET button on the power supply cord.
The Power button has not been pressed.| Press the Power button on the Control Panel or Remote Control to turn ON the air conditioner.
There is no power to the electrical outlet.| Plug a working lamp into the outlet to check for power.
A household fuse has blown or a circuit breaker has tripped.| Replace the fuse or reset the circuit breaker.
The control was programmed for a Time Delay.| Cancel the Time Delay. See “Control Panel.”
The batteries in the remote control are dead.| Replace the batteries.
The internal water tank is full. NOTE: The air conditioner automatically turns off, and the Water Full indicator illuminates to alert you of this condition.| Empty the water tank. See “Air Conditioner Care.”
Remote control is not working| Batteries are dead.| Replace the batteries.
Batteries are installed incorrectly.| Make sure the batteries are inserted in the correct position.
Air conditioner is working but the room is not cooling.| The room temperature is hot.NOTE: On extremely hot and humid days,the air conditioner will take longer to cool the room.| Allow time for the room to cool when you first turn on the unit.Make sure the air conditioner has an adequate BTU rating for the size of the room being cooled.
The control is set incorrectly to Fan or Dehum mode.| Set the Mode to Cool and the Fan Speed to High.
Airflow is restricted.| Remove any obstacles to the airflow and redirect airflow for uniform cooling.
Temperature set too high.| Lower the set temperature.
Air filters are dirty or restricted.| Clean the air filter. See “Air Conditioner Care.”
Air conditioner installed incorrectly| Check the exhaust hose and window panel for proper installation.
Doors and windows are open.| Close the doors and windows to the room being cooled to prevent cooled air from escaping.

LIMITED WARRANTY

Call 866.907.1655 (in the United States) to initiate the product replacement process. Have serial number and model number available when calling for service.

For The Period Of:| Haier Appliances Will Replace:
---|---
One Year From the date of the original purchase| Any part of the air conditioner which fails due to a defect in materials or workmanship. During this limited one-year warranty, GE Appliances will also provide, free of charge, all labor and related service to replace the defective part.

What Haier Appliances Will Not Cover:

  • Service trips to your home to teach you how to use the product.
  • Improper installation, delivery or maintenance. If you have an installation problem, or if the air conditioner is of improper cooling capacity for the intended use, contact your dealer or installer. You are responsible for providing adequate electrical connecting facilities.
  • Failure of the product resulting from modifications to the product or due to unreasonable use including failure to provide reasonable and necessary maintenance.
  • In commercial locations, labor necessary to move the unit toa location where it is accessible for service by an individual technician.
  • Replacement of house fuses or resetting of circuit breakers.
  • Failure due to corrosion on models not corrosion-protected.
  • Damage to the product caused by improper power supply voltage, accident, fire, floods or acts of God.
  • Incidental or consequential damage caused by possible defects with this air conditioner.
  • Damage caused after delivery

EXCLUSION OF IMPLIED WARRANTIES— Your sole and exclusive remedy is product repair as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law

This limited warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA. If the product is located in an area where service by a GE Authorized Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Service location for service. In Alaska, the limited warranty excludes the cost of shipping or service calls to your home.

Some states do not allow the exclusion or limitation of incidental or consequential damages. This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.

Warrantor US:
GE Appliances, a Haier company
Louisville, KY 40225

IMPORTANT

Do Not Return This Product To The Store

If you have a problem with this product, please call 1-877-337-3639 for the name
and telephone number of the nearest authorized service center.
DATED PROOF OF PURCHASE REQUIRED FOR WARRANTY SERVICE

Haier Logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals