JBC Tools TIA Analogic Thermometer Instruction Manual

June 15, 2024
JBC Tools

JBC Tools TIA Analogic Thermometer

Product Information

Specifications

  • Product Name: TIA Analogic Thermometer
  • Model: TIA-A
  • Temperature Range: Not specified
  • Thermocouple Type: E
  • Scale Unit: Not specified
  • Total Weight: 0.7 kg / 1.5 lb
  • Compliance: CE standards, ESD Safe

Warranty Information

JBC provides a 2-year warranty for this product, covering all manufacturing defects. The warranty includes the replacement of defective parts and labor. Please note that the warranty does not cover product wear or misuse. To ensure the validity of the warranty, the equipment must be returned, with postage paid, to the dealer from where it was purchased. Additionally, customers can register the product within 30 days of purchase to obtain an extra year of warranty. Register here: Product Registration.

Disposal Information

As per the European directive 2012/19/EU, this product should not be thrown in the garbage. Electronic equipment at the end of its life must be collected and returned to an authorized recycling facility.

Product Usage Instructions

Packing List

  • Thermometer – 1 unit (Ref. TIA-A)
  • Cable – 1 unit (Ref. 0780476)
  • Manual – 1 unit (Ref. 0031052)

Operation

  1. Apply solder: The soldering tip must be properly tinned before taking a reading. Apply solder to the center of the sensor wire.
  2. Read the temperature: Place the tip in the center of the sensor and wait until the temperature stabilizes to obtain an accurate reading.

Reading the Sleep Temperature

To read the sleep temperature, connect one end of the cable to the metal part of the tool stand and the other end to the cartridge. Follow the instructions mentioned in the Operation section (steps 1 & 2) to take the temperature reading.

Calibration

  1. Pull out the sensor and adjust the reading needle using a screwdriver at room temperature.
  2. Connect the TIA Thermometer to the pattern generator thermocouple Type E using the provided connections (+ and -).
  3. Choose the desired temperature on the generator and take a reading on the thermometer.
  4. Note down the deviation to correct future readings.
  5. Fit the STA sensor back in place.

Changing the Sensor

To replace the STA sensor, simply pull it off the base and replace it with a new one.

Notes

No specific notes are mentioned in the user manual.

FAQ (Frequently Asked Questions)

  1. What is the temperature range of the TIA Analogic Thermometer?
    • The temperature range is not specified in the user manual.
  2. What type of thermocouple does the TIA Thermometer use?
    • The TIA Thermometer uses a Type E thermocouple.
  3. What is the total weight of the TIA Analogic Thermometer?
    • The total weight of the TIA Analogic Thermometer is 0.7 kg / 1.5 lb.
  4. How can I extend the warranty for the TIA Analogic Thermometer?
    • You can extend the warranty by registering the product within 30 days of purchase.
    • Register here: Product Registration.
  5. How should I dispose of the TIA Analogic Thermometer?
    • As per the European directive 2012/19/EU, electronic equipment at the end of its life must be collected and returned to an authorized recycling facility. Please do not throw it in the garbage.

This manual corresponds to the following reference: TIA-A

Packing List

The following items are included:

  • Thermometer …………………………………………………………………………………………………………………………… 1 unit

Ref. TIA-AJBC-Tools-TIA-Analogic-Thermometer-FIG-2

Operation

For a correct temperature reading, you need to apply solder to the center of the sensor wire.

  1. Apply solder
    • The soldering tip must be properly tinned before taking a reading.
  2. Read the temperature
    • Place the tip in the center of the sensor. This is reinforced for this purpose. Wait until the temperature stabilizes.

Reading the Sleep temperature

Connect one end of the cable to the metal part of the tool stand and the other end to the cartridge and proceed according to the instructions in Operation (steps 1 & 2).JBC-Tools-TIA-Analogic-Thermometer-FIG-5

Calibration

  1. Pull out the sensor and adjust the reading needle using a screwdriver at room temperature.
  2. Connect the TIA Thermometer as follows:
  3. Choose the temperature on the generator and take a reading on the thermometer.
  4. Take note of the deviation to correct future readings.
  5. Fit the STA sensor in place.

Changing the sensor

To replace the STA sensor, pull it off the base.

Specifications

TIA Analogic Thermometer

  • Ref.: TIA-A
    • Temperature range: 20 – 500 °C / 69 – 920 °F
  • Thermocouple: Type E
    • Ambient temperature correction: Adjusted for 20 °C / 68 °F
  • Scale Unit: 10 °C / 20 °F
    • Total weight: 0.7 kg / 1.5 lb
  • Complies with CE standards.
    • ESD Safe.

Warranty

  • JBC’s 2-year warranty covers this equipment against all manufacturing defects, including the replacement of defective parts and labor.
  • The warranty does not cover product wear or misuse.
  • For the warranty to be valid, equipment must be returned, postage paid, to the dealer where it was purchased.
  • Get 1 extra year JBC warranty by registering here: https://www.jbctools.com/productregistration/within 30 days of purchase.
  • This product should not be thrown in the garbage.
  • Per the European directive 2012/19/EU, electronic equipment at the end of its life must be collected and returned to an authorized recycling facility.
  • www.jbctools.com

Documents / Resources

| JBC Tools TIA Analogic Thermometer [pdf] Instruction Manual
TIA Analogic Thermometer, TIA, Analogic Thermometer, Thermometer
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)