FRECAN TR10 Slim Ceiling Mount Range Hood
Product Information
Specifications
- Model: TR 10 SLIM 1000, TR 10 SLIM 1200
- Installation: Do not install directly into drywall (Pladur)
- Reinforcement: False ceiling reinforced to support a minimum of 34 kg
- Dimensions:
- X (mm): 1000, 1200
- Y (mm): 500, 700
- Z (mm): 170, 170
- Cut Out (mm): 970 x 475, 1170 x 675
Product Usage Instructions
Preparing the Installation Area
Before installing the TR 10 SLIM, ensure that the installation area meets the following requirements:
- The false ceiling is reinforced to support a minimum of 34 kg.
- The installation surface is not drywall (Pladur). Do not install the product directly into the drywall.
Mounting the TR 10 SLIM
- Choose the appropriate model based on the dimensions required (1000mm or 1200mm). Ensure the dimensions of the cut-out match the specifications provided.
Cutting the Opening
- Carefully cut out the opening in the false ceiling using the provided cut-out dimensions (970mm x 475mm or 1170mm x 675mm).
Placing the TR 10 SLIM
- Insert the TR 10 SLIM into the cut-out opening, ensuring a secure fit.
Wiring
- Connect the necessary electrical wires to the TR 10 SLIM following standard electrical practices and local regulations.
Securing the Wiring
- Make sure to secure the wiring properly to avoid any potential hazards or damage to the product or surrounding areas.
Testing
- After completing the installation and wiring, test the TR 10 SLIM to ensure proper functionality.
Maintenance
- Regularly clean the TR 10 SLIM to remove dust and debris that may affect its performance. Avoid using harsh chemicals or abrasive materials during cleaning.
Frequently Asked Questions (FAQ)
Q: Can I install the TR 10 SLIM directly into the drywall?
- A: No, it is not recommended to install the TR 10 SLIM directly into drywall. Use a reinforced false ceiling to support the product.
Q: What is the maximum weight the false ceiling can support?
- A: The false ceiling should be reinforced to support a minimum of 34 kg.
Q: How do I wire the TR 10 SLIM?
- A: Follow standard electrical practices and local regulations when connecting the electrical wires to the TR 10 SLIM.
- NO INSTALE DIRECTO SOBRE PLACAS DE PLADUR
- DON’T INSTALL DIRECTLY INTO DRYWALL PLADUR
INSTALLATION INSTRUCTION
- FALSO TECHO REFORZADO PARA SOPORTAR MIN ( 34KG)
- FALSE CEILING REINFORCED TO SUPPORT MIN (34 KG)
X (mm) | Y (mm) | Z (mm) | CUT OUT (mm) | |
---|---|---|---|---|
TR 10 1000 | 1000 | 500 | 170 | 970 X 475 |
TR10 1200 | 1200 | 700 | 170 | 1170 X 675 |