Product Information
Technical Specifications
- Max Hold Force (kgf): 256
- Air Port Threads: 2X G1/8
- Net Weight (kg): 2.1
- Max Air Pressure (MPa): 0.7
- Normal Actuation Pressure: 0.5 MPa
- ON/OFF Position Sensor: FLUXUS Sensor, M8 4-Pin Male Connector N.O.
- ON/OFF Position Sensor Power Supply: 10-30V DC
- ON/OFF Position Sensor Wire Length (m): 2.4
- Maximum Operating Temperature: 70°C
- Actuation Time: 0.5 s
- Fastest Complete Cycle Frequency: 0.5 Hz
Features
- 6MM HEX DRIVE MANUAL OVERIDE
- TOP MOUNTING OPTION
- G1/8 AIR FITTINGS
- FLUXUS SENSOR
- SIDE MOUNTING
- GRIPPING SURFACE
Product Usage Instructions
Disclaimer and Warranty
This product should be operated using clean air and under specified operating parameters. The product should only be actuated when in contact with a steel target. The product warranty is good for 1 year or 1.5 million cycles when operated following these guidelines.
Performance
Flux Force and Recommended Safe Working Loads:
Target Thickness (mm)| Flux Force (kgf)| Normal Work Load (kg)| Shear Work
Load (kg)
---|---|---|---
0.4| 8.3| 1.7| 0.8
0.5| 11.3| 2.3| 1.1
0.6| 14.4| 2.9| 1.4
0.8| 22.0| 4.4| 2.2
1.0| 27.4| 5.5| 2.7
1.2| 34.5| 6.9| 3.4
1.5| 41.8| 8.4| 4.2
2.0| 67.1| 13.4| 6.7
2.5| 94.5| 18.9| 9.5
3| 116.6| 23.3| 11.7
3.5| 134.5| 26.9| 13.4
4| 155.0| 31.0| 15.5
4.5| 190.9| 38.2| 19.1
5| 217.3| 43.5| 21.7
5.5| 233.8| 46.8| 23.4
7| 242.1| 48.4| 24.2
8| 256.0| 51.2| 25.6
10| 256.0| 51.2| 25.6
Holding Force Deratings for Material and Contact
Condition:
- Target Material – Low Carbon Steel: Derating 1.0
- Target Material – High Carbon Steel: Derating 0.9
- Target Material – Ferritic Stainless Steel: Derating 0.5
- Target Material – Cast Iron: Derating 0.45
- Contact – Perfect Flat: Derating 1.0
- Contact – Imperfect Flat: Derating 0.9
- Contact – V Pole on Round: Derating 0.5
- Contact – Multi-Point: Derating 0.5
Calculation Examples
Example A: V pole contact on 2mm thick low carbon (mild) steel
tube: 67.1 x 0.5 x 1.0 = 33.55 kgf Flux Force
Example B : Imperfect flat contact on cast iron that is over 10mm
thick: 256.0 x 0.45 x 0.9 = 103.68 kgf Flux Force
Dimensions
FA76 Base Dimensions with No Poles and No Sensors FA76 Standard Sensor Dimensions & Wiring Diagram FA76 Standard Flat Pole FA76 Standard V Pole FA76 Standard Pin Pole (pin not included) Optimized for round targets 120mm – 240mm OD Optimized for round targets 30mm – 120mm OD FA76 Standard Blank Pole
FAQ
- Q: How long is the product warranty?
- A: The product warranty is good for 1 year or 1.5 million cycles when operated following the specified guidelines.
- Q: What is the maximum operating temperature?
- A: The maximum operating temperature is 70°C.
- Q: What is the actuation time?
- A: The actuation time is 0.5 seconds.
- Q: What is the fastest complete cycle frequency?
- A: The fastest complete cycle frequency is 0.5 Hz. 2023
Technical Specifications and Features
overview product
DISCLAIMERS AND WARRANTY
This product should be operated using clean air and under specified operating parameters. The product should only be actuated when in contact with a steel target. The product warranty is good for 1 year or 1.5 million cycles when operated following these guidelines.
Performance
- Flux Force is the amount of gripping force generated by the product on a target part.
- Normal Work Load is the max target part weight reccomended for handling in the normal orientation.
- Shear Work Load is the max target part weight reccomended for handling in shear or perpendicular orientation.
Holding Force Deratings for Material and Contact
Calculation Examples
Example A
V pole contact on 2mm thick low carbon (mild) steel tube: 67.1 x 0.5 x 1.0 =
33.55 kgf Flux Force
Example B
Imperfect flat contact on cast iron that is over 10mm thick. 256.0 x 0.45 x 0.9 = 103.68 kgf Flux Force
These deratings are estimates based on common application condi-tions. Please contact Fluxus for additional support.
Dimensions
FA76 Base Dimensions with No Poles and No Sensors
FA76 Standard Sensor Dimensions & Wiring Diagram
FA76 Standard Flat Pole
FA76 Standard V Pole
FA76 Standard Pin Pole (pin not included)
FA76 Standard Blank Pole