tp-link TL-SG1016PE 16-Port Gigabit Easy Smart Switch Installation Guide

June 15, 2024
tp-link

tp-link TL-SG1016PE 16-Port Gigabit Easy Smart Switch

tp-link-TL-SG1016PE-16-Port-Gigabit-Easy-Smart-Switch-
product

LED Explanation

Power

  • On: Power on
  • Off: Power off

Link/Act

tp-link-TL-SG1016PE-16-Port-Gigabit-Easy-Smart-Switch-
fig-2

Note: Images may differ from your actual product. For simplicity, we will take DS108GE for example throughout this Guide.

Connection

tp-link-TL-SG1016PE-16-Port-Gigabit-Easy-Smart-Switch-
fig-3

Configuration

  • The switch is plug-and-play. To configure the switch, you can use the Web-based GUI or the configuration utility.
  • The utility is only supported on Windows now.

Using the Web-based GUI

  1. Find out the IP address of the switch.
    • By default, the switch receives an IP address from a DHCP server (or a router that functions as a DHCP server) in your network. You can find out this IP address on the DHCP server.
    • If the switch cannot receive an IP address from a DHCP server, it uses the static IP address of 192.168.0.1, with a subnet mask of 255.255.255.0.
  2. Configure the IP address on your PC to make sure the switch and PC are in the same subnet.
    • If the switch uses an IP address assigned by a DHCP server, set your PC to obtain an IP address automatically from the DHCP server.
    • If the switch uses 192.168.0.1 as the IP address, configure your PC’s IP address as 192.168.0.x (”x” ranges from 2 to 254), and subnet mask as 255.255.255.0.
  3. Launch a web browser on your PC, enter the IP address of the switch in the address bar and press Enter. Log in with admin as both user name and password.

Now you can configure the switch using the Web-based GUI. For further information, refer to the User Guide.
Go to https://www.tp-link.com/support, search for the model number of your switch, and you can find this guide on the product Support web page.

Note: If the switch gets a new IP address from the DHCP server, your connection to the switch will be lost. Enter the new IP address in your browser to access the switch again.

Using the Configuration Utility

  1. Go to https://www.tp-link.com/support and search for the model number of your switch. Download the Easy Smart Configuration Utility from the Product Support web page on your PC.
  2. Decompress the downloaded file, run the installation wizard and follow the prompts to install the Easy Smart Configuration Utility.
  3. Double-click the icon on the desktop, and the utility Home page will display a list of TP-Link switches on the local network.
  4. Click to find out the IP parameters of the switch.
    • If the switch uses an IP address assigned by a DHCP server, set your PC to obtain an IP address automatically from the DHCP server.
    • If the switch uses 192.168.0.1 as the IP address, configure your PC’s IP address as 192.168.0.x (“x” ranges from 2 to 254), and subnet mask as 255.255.255.0.
  5. Double-click the switch that you want to configure. Log in with admin as both user name and password.

Now you can configure the switch using the configuration utility. For further information, refer to the Easy Smart Configuration Utility User Guide.
Go to https://www.tp-link.com/support, search for the model number of your switch, and you can find this guide on the product Support web page.

Specifications

General Specifications

tp-link-TL-SG1016PE-16-Port-Gigabit-Easy-Smart-Switch-
fig-9 tp-link-TL-SG1016PE-16-Port-
Gigabit-Easy-Smart-Switch-fig-10

Environmental and Physical Specifications

  • Operating Temperature: 0 ˚C to 40 ˚C (32 ˚F to 104 ˚F)
  • Storage Temperature: -40 ˚C to 70 ˚C (-40 ˚F to 158 ˚F)
  • Operating Humidity: 10% RH to 90% RH non-condensing
  • Storage Humidity: 5% RH to 90% RH non-condensing

Frequently Asked Questions (FAQ)

Q1. Why is the Power LED not lit?

By default, the Power LED should be lit when the power system is working normally. If the Power LED is not lit, please check the following:

  • A1: Make sure the power adapter is connected to the switch with the power source properly.
  • A2: Make sure the voltage of the power supply meets the requirements of the input voltage of the switch.
  • A3: Make sure the power source is ON.
  • A4: On the LED On/Off configuration page, check whether the LED status is on. By default, the LED status is on.

Q2. Why is the Link/Act LED not lit while a device is connected to the corresponding port?

Please check the following:

  • A1: Make sure that the cable connectors are firmly plugged into the switch and the device.
  • A2: Make sure the connected device is turned on and works normally.
  • A3: The cable must be less than 100 meters long (328 feet).
  • A4: On the LED On/Off configuration page, check whether the LED status is on. By default, the LED status is on.

Some models featured in this guide may be unavailable in your country or region. For local sales information, visit https://www.tp-link.com.

Safety Information

  • Keep the device away from water, fire, humidity or hot environments.
  • Do not attempt to disassemble, repair, or modify the device. If you need service, please contact us.
  • Do not use a damaged charger or USB cable to charge the device.
  • Do not use any other chargers than those recommended.
  • The adapter shall be installed near the equipment and shall be easily accessible.
  • Place the device with its bottom surface downward.
  • Please read and follow the above safety information when operating the device.
  • We cannot guarantee that no accidents or damage will occur due to improper use of the device. Please use this product with care and operate at your own risk.

UK declaration of conformity

  • TP-Link hereby declares that the device complies with the essential requirements and other relevant provisions of the Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016.
  • The original UK Declaration of Conformity may be found at
  • https://www.tp-link.com/support/ukca/.

EU declaration of conformity (For DS105GE and DS108GE)

  • TP-Link hereby declares that the device complies with the essential requirements and other relevant provisions of directives 2014/30/EU, 2014/35/EU, 2009/125/EC, 2011/65/EU and (EU)2015/863.
  • The original EU Declaration of Conformity may be found at
  • https://www.tp-link.com/en/support/ce/.

EU declaration of conformity (For DS116GE)

  • TP-Link hereby declares that the device complies with the essential requirements and other relevant provisions of directives 2014/30/EU, 2014/35/EU, 2011/65/EU and (EU)2015/863.
  • The original EU declaration of conformity may be found at
  • https://www.tp-link.com/en/support/ce/.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

tp-link User Manuals

Related Manuals