Technaxx TX-248 Solar Balcony Power Plant 600W WiFi User Manual

June 15, 2024
Technaxx

Technaxx TX-248 Solar Balcony Power Plant 600W WiFi

Specifications

  • Model: TX-248
  • Article No.: 5074
  • Date: 06/2023

Important notes at the start

According to the German Federal Network Agency, installations exceeding 600W may only be carried out by electrical contractors. In addition, a corresponding report must be made to the network operator! Therefore, contact a specialist electrical company if your installation exceeds 600W!

Explanation of the pictograms used

  • Read the user manual
  • Warning: Caution, risk of electric shock.
  • Caution: Hot surface. Specifications are subject to change without notice – please make sure you are using the latest manual available on the manufacturer’s website.

Note Before using the appliance for the first time, please read the instructions for use and safety information carefully.

This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capacities, or by persons lacking in experience or knowledge unless they are supervised or instructed on the use of this device by a person responsible for their safety. Children should be supervised to ensure they do not play with this device.

Keep this user manual for future reference or product sharing carefully. Do the same with the original accessories for this product. In case of warranty, please contact the dealer or the store where you bought this product.
Enjoy your product.  Share your experience and opinion on one of the well- known internet portals.

Important notes at the start

ATTENTION: According to the German Federal Network Agency, installations exceeding 600W may only be carried out by electrical contractors. In addition, a corresponding report must be made to the network operator! Therefore, contact a specialist electrical company if your installation exceeds 600W!

Explanation of the pictograms used

  • Read the user manual
  • Warning
  • Caution, risk of electric shock.
  • Caution, hot surface

Specifications subject to change without notice – please make sure you are using the latest manual available on the manufacturer’s website.

Note

  • Only use the product for purposes due to its intended function.
  • Do not damage the product. The following cases may damage the product: Incorrect voltage, accidents (including liquid or moisture), misuse or abuse of the product, faulty or improper installation, mains supply problems including power spikes or lightning damage, infestation by insects, tampering or modification of the product by persons other than authorized service personnel, exposure to abnormally corrosive materials, insertion of foreign objects into the unit, used with accessories not preapproved.
  • Refer to and heed all warnings, precautions, and safety instructions in the user manual.

Safety instructions

  • Read the user manual carefully. They contain important information on the use, safety and maintenance of the device. Keep the user manual in a safe place and pass them on to subsequent users if necessary.

  • Before installing or using the Solar Balcony Power Plant, please read all instructions and warnings in the technical documentation, on the microinverter, and the solar modules.

  • The device may only be used for its intended purpose by this user manual.

  • Observe the safety instructions during use.

  • Before commissioning, check the device and its connecting cable as well as accessories for damage. Do not use the device if it shows visible damage.

  • Operate the device only from household power sources. Check whether the mains voltage specified on the type plate corresponds to that of your mains supply.

  • Perform all electrical installations under local regulations (including VDE).

  • When installing and operating the plug-in photovoltaic system, observe the national legal regulations and the connection conditions of the grid operator.
    In particular, DIN VDE V 0100-551-1 (VDE V 0100-551-1), VDE AR-N 4105:2018-11, DIN VDE 0100-712, DIN VDE 0100-410 and DIN VDE V 0628-1 (VDE V 0628-1).

  • Note the information on determining the line reserve at the end of these operating instructions.

  • Note that the housing of the microinverter is a heat sink and can reach a temperature of 80 degrees Celsius. To reduce the risk of burns, do not touch the housing of the microinverter.

  • Do not squeeze the power cord, do not pull it over sharp edges or hot surfaces; do not use the power cord for carrying.

  • If the power cord of this device is damaged, it must be replaced by the manufacturer or its customer service or a similarly qualified person to avoid hazards.

  • The appliance is intended for household or similar use only. It must not be used for commercial purposes!

  • Make sure that the device is well secured during operation and cannot be tripped over by cables.

  • Never use the device after a malfunction, e.g. if the device has been dropped into water or damaged in any other way.

  • The manufacturer assumes no responsibility in the event of incorrect use resulting from failure to follow the instructions for use.

  • Modification or alteration of the product will affect the product safety. Caution: Risk of injury!

  • All modifications and repairs to the device or accessories may only be carried out by the manufacturer or persons expressly authorized by the manufacturer for this purpose.

  • Make sure that the product is operated from a power source that is easily accessible so that you can quickly disconnect the device from the mains in case of an emergency.

  • Never open the product without authorization. Never carry out repairs yourself!

  • Handle the product with care. It can be damaged by shocks, impacts, or falling from even a low height.

  • Keep the product away from extreme heat.

  • Never immerse the product in water or other liquids.

  • Technical changes and errors accepted!

Warning

  • Do not tamper with or manipulate the micro-inverter or other parts of the equipment under any circumstances.
  • Risk of damage due to improper modifications!
  • Keep all contacts dry and clean!

Caution Risk of electric shock!

  • When operating this device, certain parts of the device are under dangerous voltage, which can lead to serious physical injuries or death. Therefore, follow the following instructions to minimize the risk of injury.
  • Disconnect the plug connection only in a de-energized state!
  • Before carrying out visual inspections and maintenance work, check that the power supply is switched off and secured against being switched on again.

Caution, hot surface!

  • The surface of the micro inverter can become very hot. Touching the surface can cause burns.
  • Mount the micro inverter in such a way that accidental contact is not possible.
  • Do not touch hot surfaces. When working on the micro inverter, wait until the surface has cooled down sufficiently.

Intended use
The micro inverter may only be operated with a fixed connection to the public power supply. The micro inverter is not intended for mobile use. Modifications to the micro-inverter are generally prohibited. For changes in the environment, you must always consult a qualified electrician. Assembly, installation, and electrical connection.

Assembly, installation, and electrical connection

Warning

  • All work including transport, installation, commissioning, and maintenance must be carried out by qualified and trained personnel.
  • The electrical connection to the central building services may only be carried out by a licensed electrician.
  • Do not connect the micro inverter to the operator grid until you have fully implemented the installation process and have received confirmation/approval from the electricity network operator.
  • If you mount the micro inverters at a great height, avoid possible fall risks.
  • Do not insert electrically conductive parts into the plugs and sockets! Tools must be dry.

Caution measures during installation

  • Installation must be performed with the unit disconnected from the grid and with the solar panels shaded and/or insulated.
  • Install the microinverter and all DC connections in a suitable location, for example under the solar panel, to avoid direct UV/sunlight exposure, rain exposure, snow accumulation, etc. In any case, sufficient air circulation for cooling must be ensured.
  • Install the micro inverter in such a way that at least 2cm distance to the nearest surface is maintained. Otherwise, the micro inverter may overheat.
  • Do not install in locations where gases or flammable materials may be present.

Qualified personnel
An adequately informed person or a person supervised by a person with electrical engineering skills and knowledge so that he or she recognizes the risks and avoids the hazards caused by electricity. For safety reasons, in this manual ‘Qualified Personnel’ means that this person is familiar with safety requirements, cooling systems, and EMC and that this person is authorized to power, ground, and attach equipment, systems, and circuits according to existing safety procedures. The micro inverter, accessories, and connected systems may only be commissioned and operated by qualified personnel.

Disclaimer

  • In no event shall Technaxx Deutschland be liable/responsible for any direct, indirect punitive, incidental, special consequential danger, to property or life, improper storage, whatsoever arising out of or connected with the use or misuse of their products.
  • Error messages may appear depending on the environment it is used in.

Features

  • Easy installation: connect, start, save power
  • Includes TX-247 WiFi stick and TX-246 bracket
  • Suitable for wall, floor and railing mounting
  • Suitable for most solar panels with a frame (35mm thickness)
  • Real-time data and alarms on the S-Miles APP
  • Data acquisition of energy production
  • Lightweight and compact microinverter
  • Suitable for feeding electricity into the 230V household grid
  • Maximum feed-in power of the inverter 600W
  • Ideal for covering the base load during the day in your home
  • MPP tracking for optimal power feeding
  • VDE compliant

Product details

Technaxx-TX-248-Solar-Balcony-Power-Plant-600W-WiFi-
FIG-1

Product Overview

Technaxx-TX-248-Solar-Balcony-Power-Plant-600W-WiFi-
FIG-2

Technaxx-TX-248-Solar-Balcony-Power-Plant-600W-WiFi-
FIG-3

Preparation
Requirements for the operation of a photovoltaic system

  • Permission from the owner or owners’ association if you are not the owner yourself
  • Wieland socket (recommendation), permanent connection or Schuko socket
  • RCD in the fuse box (standard nowadays)
  • Socket, better protected outdoors
  • Electricity meter with backstop or bidirectional meter

ATTENTION!
The following requirements must be met to operate a photovoltaic system.

  • You must register your photovoltaic system with your responsible grid operator.
  • In addition, a report must be submitted to the responsible authority (Market Master Data Register (MaStR)).
  • You must have ensured that an appropriate and sufficiently dimensioned feed-in socket is already available.
  • Meter replacement required: A bi-directional meter must be present or depending on what your electricity provider specifies. Simple electricity meters are often not sufficient.
  • If necessary, the consent of the landlord is required.
  • If you are unsure, please have the local conditions checked, if necessary, or contact your network operator for information.

Connecting the micro inverter
The micro inverter is already pre-installed on a solar module in this set It may only be necessary to connect the solar modules (DC) to the micro inverter. On the AC side, only the connection with the enclosed connection cable must be made. A Wieland plug connection is recommended here according to VDE. A Schuko plug connection with a Schuko socket is also possible.

CAUTION
Observe all local regulations and restrictions during installation.

The external protective grounding conductor is connected to the protective grounding conductor terminal of the micro inverter via AC connection. When connecting, connect the AC terminal first to ensure the grounding of the microinverter. Then connect the DC terminals. When disconnecting, disconnect the AC first by opening the branch circuit breaker but keeping the protective grounding conductor in the branch circuit breaker connected to the microinverter. Then disconnect the DC inputs.

  • Do not, under any circumstances, connect the DC input if the AC connection is not connected.
  • Install disconnect devices on the AC side of the microinverter.
  • It is strongly recommended to install surge protectors in the appropriate meter box.
  • You should not use an AC residual current device to protect the corresponding circuit to the micro-inverter, even if it is an outdoor circuit. None of the small residual current devices (5~30 mA) are designed for regeneration and will be damaged if regeneration occurs. The same is true for AC arc fault circuit breakers. They are not evaluated for regenerative power and could be damaged if regenerated with the output of a solar micro inverter.

Connect the solar panels (DC connection)
Connect the solar panel’s DC cables to the DC input side of the microinverter.

The 600W micro inverter provides two pairs of MC4 connectors for two solar panels. Simply connect the DC connection cables of the micro inverter to the matching counterpart of the solar panel. When doing so, plug the pair of connectors together until you hear a “click” sound. The connectors of some solar panels have the polarity (+, -) printed on them, which is valid for the panels. The DC cable of the micro inverter with the plus marking (+) is connected to the – pole of the panel, the negative marked cable (-) to the + pole. Make sure that the polarity is correct.

Note: When plugging in the DC cables, if the AC cable is already plugged in, the micro inverter LED should immediately flash green and start synchronizing with the grid within 2 minutes. If the AC cable is not plugged in, the red LED will flash continuously and repeat this until the AC cable is plugged in (see chapter LED Status).

Connecting the micro inverter to the AC grid (AC connection)
WARNING:
A maximum 1x 600W may be connected to an EU / 50Hz / 230V installation with 16A automatic circuit breaker.
The connection to the mains is made with a suitable power cable. Only use 3-core cables that are also approved for outdoor installation and have a conductor cross-section adapted to the amperage (preferably 1.5mm² or 4mm²).
Fasten the connection cables to the mounting rail using UV-stable cable ties in such  a way that the cables are protected from rain and sun and, in particular, the plug connections cannot lie in a puddle of water. To connect the micro inverter and the connection cable, the pre-assembled AC plug-in system in combination with an AC cable and assembled Betteri IP68 connection socket or the AC string input/output can be used, depending on the delivery variant. To mount a Wieland connector, the pre-assembled Betteri IP68 connector system must be removed.

Note: Other plug connections/systems may be possible, provided they are suitable for outdoor use and the current levels involved.

Mounting

Observe the following instructions for the corresponding installation.

General hints

  • Before you start mounting, check the solar module, the inverter, and all cables for visual damage.
  • Do not stand on the module or the module frame. To prevent grease stains on the module, avoid contact with your hands on the glass surface and ideally wear work gloves.
  • Place the solar module face down on a clean, flat, soft surface.
  • Write down the model and serial number of the components [inverter, solar module(s)] and keep the numbers. In the event of a defect, we will need the numbers for unique identification.

Balcony : The solar module is only suitable for installation up to a height of 4m (upper edge of the module), provided that there is also no public traffic below the module.

Flat roof (bitumen roof)

  • The statics of the roof for the photovoltaic system must be checked by the customer. The photovoltaic system can be installed up to a roof height of 9m, a sea level of max. 350 m and a roof pitch of 45°.
  • We recommend a distance of 1.25 m to firewalls of adjacent buildings (e.g. row houses). For more detailed requirements for your federal state, please refer to your state building code (LBO).
  • Make sure that national and site-specific building regulations, occupational safety and accident prevention regulations, standards and environmental protection regulations are observed.

Weight the module mount evenly

  • The solar module (up to 19kg) should be positioned at ground level or centered on a flat roof.
  • Suitable is a bracket for mounting on bitumen, or concrete, in the garden on the lawn or terrace.
  • The weighting is calculated according to the terrain IV (urban area), where at least 15% of the area is covered with buildings, the average height of which exceeds 15m, and may differ for other heights or terrain structures.
  • In case of installation on a flat roof, the top edge of the building should be lower than 15m and the photovoltaic system should be at least 1.25m away from the neighbor’s roof surface. The maximum slope of the ground may be 5°.
  • One concrete slab should weigh 9kg.
  • Check whether the statics of the installation site are suitable for the photovoltaic system. Technaxx Germany does not assume any liability for the suitability of your installation site.

Facade

  • For the mounting you need your own dowels and screws. Since every wall is different.
  • Up to a height (upper edge of the module) of 4m the glass-foil module can be used, as long as you cannot step directly under the module.

First commissioning
After mechanical and electrical installation of the solar power system, you can put the system into operation. There should be enough sunshine for this. The solar panels need to produce at least a start voltage of 22V.

Initial state:

  1. The micro inverter is connected to the solar panels
  2. The microinverter is connected to the house mains via a Wieland plug(recommended) or Schuko plug.
  3. The cables are fixed and protected from rain and sunlight
  4. The feed line is connected to the mains via a circuit breaker

Proceed as follows:

  1. Turn on the circuit breaker and any other switches that may be present.
  2. Switch on the main AC switch.
  3. The unit LED should begin flashing green after you turn on the AC circuit breaker. See chapter LED status for more information.
  4. The micro inverter starts feeding (grid synchronization) within 2 minutes if there is sufficient solar radiation. The status LED indicates the basic function. You can check the feed-in power with a suitable power socket energy meter (needs to be waterproof for outside use!).
  5. If you have installed a feed-in meter, you can also use it to check the current feed-in power or energy.

Note: When AC power is applied but the micro inverter is not started, approximately 0.2W of power can be measured for each micro inverter using a power meter. This power is reactive power, not consumption from the utility grid.

WiFi-Stick installation (DTU TX-247)

  1. Solar panels and microinverters should be already installed and connected to the house grid.
  2. Find best location for DTU. The maximum communication distance between the DTU and the microinverter is 150 m, maximum communication distance between the DTU and the router is 10m in open space. Walls, roofs, or other obstacles in between will affect the signal and reduce the communication distance in actual installations.
  3. Connect the DTU to the adapter and plug it into the wall socket, like beside.
  4. Once the DTU powers on, the red, green, and blue lights will flash in sequence for one second each for 30 seconds.

Get the App
To download the App S-Miles Installer from the App Store or the Google Play Store search for “S-Miles Installer” or scan the QR-code below. [iOS 13.0 or above; Android 10.0 or above (03-2023)]

Technaxx-TX-248-Solar-Balcony-Power-Plant-600W-WiFi-
FIG-6

Follow the instructions in the APP to register and connect the microinverter. Note: It takes up to 30 minutes until the first values are shown in the App.

Webpage

You can view the inverter’s operating details on the computer web page by accessing the S-Miles Cloud (Hoymiles Monitoring Platform) at https://world.hoymiles.com. Therefor use your login which you created via S-Miles Installer App registration.

  • Enter account = Login account, username created by app.
  • Enter password = Password created for app login.

Note: You will need to be connected to the Hoymiles DTU WiFi access point by APP for first registration and configuration.

If you need further assistance, please contact our support or read the detailed TX-247 manual on our homepage:
https://www.technaxx.de/products/ and search for ‘TX-247’.

LED status
The LED of each microinverter provides information about the current status. All micro inverters draw their supply voltage from the DC connector/solar panels.

St atus during power-up
The green LED will flash fast a few times. The switch-on process usually takes up to 2 minutes. The following LED status can occur:

Flashing fast red (1s): No AC connection è no grid feed
Flashing slow green (3s): AC connection &

DC connection voltage lower 22V

| è no grid feed
Flashing fast green (1s):| AC connection &

DC connection voltage over 22V

| è grid feed
No LED Flashing/LED off:| No   DC   connection/solar   panels connected| è no grid feed

Status after the switch-on process

  • A fast green flashing LED indicates normal status and an active feed into the grid. If the LED remains flashing red after 3 minutes, this indicates an error with solar panel voltage that is too low (below 22V) or a missing AC voltage.
  • The micro inverter can only start feeding (again) after the cause of the error has been eliminated. The reason for this error could be a faulty solar panel connection / AC connection or the connected grid exceeds / falls below the voltage/frequency range of the microinverter. If the LED shows no function or remains OFF, the most common cause is that there is no connection to the solar panel or the solar panel voltage is far below the start voltage.

Troubleshooting

Maintenance work and troubleshooting on the microinverter may only be carried out by qualified personnel. Modifications to the micro-inverter are generally prohibited. The micro inverter is potted, the electronics cannot be repaired. The TX-204 micro inverter draws its supply voltage from the DC side. To restart the microinverter, the solar panels must be disconnected from the micro inverter. The start-up process usually takes place within 2 minutes. For troubleshooting purposes, perform the following steps in the order listed:

  1. Check that all AC fuses are turned ON.

  2. Check all connection cables for external damage.

  3. Check all AC side connections for damage or connection errors.

  4. Measure at the connection points. The applied mains voltage must not exceed or fall below the AC voltage range of 180-275V.

  5. Restart the micro-inverter by disconnecting and reconnecting the DC power / solar panels. A normal start-up process should be indicated by a green LED (see LED status).
    CAUTION: Never disconnect the DC cables while the micro inverter is generating power.

  6. Measure the voltage of the solar panel to the micro-inverter with a suitable multi-meter. The required starting voltage of the microinverter is above DC22V.

  7. Check the MC4 connectors of the micro inverter and solar panel(s). Damaged DC connections must be replaced.

  8. If necessary, check with your grid operator whether the grid frequency matches the frequency range of the microinverter.
    CAUTION!

    • Do not attempt to repair the microinverter.
    • If the above steps do not solve the problem, contact our support or an electrician.
    • The AC connection on the microinverter cannot be replaced/repaired. If the cable has been damaged, the device should be disposed of.
    • Unless otherwise specified, maintenance work must be carried out with the equipment disconnected from the mains (mains switch open) and the solar panels covered, or insulated.
    • Do not use rags or corrosive products for cleaning that could corrode parts of the equipment or cause electrostatic charges.
    • Avoid temporary repairs. All repairs should be made only with original spare parts.
    • Each micro-inverter should be protected by a circuit breaker, but central disconnect protection is not required unless specified by national standards, or by the responsible network operator.

Technical specifications

For the technical specifications of the solar module, please refer to the enclosed data sheet.

PV Micro Inverter 600W TX-204

DC-input

Recommended panel power (W)| 240-380 (per panel)
Panel compatibility| 60-cell or 72-cell panels
Max. number of panels| 2
Panel connection| MC4
MPPT voltage range (V)| 29-48
Starting voltage (V)| 22
Operating voltage range (V)| 16-60
Max. input voltage (V)| 60
Max. input current (A)| 2x 11.5
Max. input short-circuit current (A)| 2×15

AC-output
Rated output power (VA)| 600
Rated output current (A)| 2.73 at 220V

2.61 at 230V

2.50 at 240V

Rated output voltage/range (V)| 220/180-275

230/180-275

240/180-275

Rated frequency/rated frequency range (Hz)| 45-55 (under 50Hz @ 220 V & 230 V)

55-65 (under 60Hz @ 220 V & 230 V)

Power factor| >0.99 standard

0.8 leading….. 0.8 delayed

Output current harmonic distortion| ≤3%
Maximum number of devices in series| 6

Efficiency, safety, and protection
Peak efficiency| 96.70%
CEC weighted efficiency| 96.50%
MPPT rated efficiency| 99.80%
Nightly power consumption (mW)| <50

Mechanical data
Ambient temperature range (°C)| -40~+65
---|---
Storage temperature range (°C)| -40~+85
Dimensions (WxHxD) mm| 250×170×28
Weight (kg)| 3.00
Protection class| NEMA outdoor (IP67)
Cooling| Natural circulating air – no fans
AC output cable length (cm)| 188
AC input cable length (cm)| 8.5

Communication
Transmission| 2.4GHz Proprietary RF (Nordic)
Frequency range| 2.403 – 2.475GHz
Radiated transmit power| max. 5.68dBM / 3.7mW

Characteristics
Compliance| VDE-AR-N 4105:2018, EN50549-1:2019, VFR2019, IEC/EN 62109-1/-2, IEC/EN 61000-3-2/-3, IEC/EN-61000-6-1/-2/-3/-4

WiFi Stick TX-247

Communication to Microinverter

Communication method| 2.4 GHz Proprietary RF (Nordic)
Frequency range| 2.403-2.475 GHz
Max. radiated output power| -2.72 dBm/0.53 mW
Modulation Type| GFSK
Maximum distance (open space)| 150 m
Maximum number of panels connected| 4 panels
Communication to Cloud (S-Miles)
Wi-Fi communication standard| Wi-Fi (802.11b/g/n)
Frequency range| 2,412-2,472 GHz
Max. radiated output power| 13.99 dBm/25.6 mW
Modulation Type| DSSS, OFDM
Maximum distance (open space)| 10 m
Data upload time| Every 15 minutes
Power Supply (Adapter)
Power supply| External adapter with USB port
Adapter input voltage/frequency| AC 100 to 240 V/50 or 60 Hz
Adapter output voltage/current| 5 V/2 A
Power consumption| 1.0 W (typical), 5 W (maximum)
Mechanical Data
Ambient temperature range (°C)| -20 to 55
Dimensions (W × H × D mm)| 143 × 33 × 12.5
Weight (kg)| 0.1
Installation option| Direct plug-in (USB port)
Indicator light| LED
---|---
Microinverter Compatibility
Microinverter model| HM series, MI series
Others
Compliance| CE: 2014/53/EU (RE Directive)


App “S-Miles Installer”

| iOS 13.0 or above; Android 10.0 or above

/ EN, DE, FR, ES, IT, NL, CZ, PL, PO (06- 2023)

Appendix
Determining the line reserve
The PI Photovoltaic Institute Berlin in cooperation with the German Society for Solar Energy (DGS), and the University of Applied Sciences (HTW) Berlin has worked out in a study that it is possible to feed in up to 2.6 amps (approx. 630 W, equivalent to 2 solar modules) with plug-in solar devices in every household with circuit breakers without any safety concerns, without having to make any changes to the house electrics. However, there may be a deviation from the applicable standard for line loading. We have described how to comply with the requirements of the standard and how to test the line in this appendix. If mini solar systems feed into the existing final circuit, the current load on individual cable sections may exceed the designed standard size. To prevent overloading of the cables in the household, they are protected by a line circuit breaker (LSS). This switches off automatically as soon as an overload occurs. As a rule, several sockets and consumers are protected by a common line protection. Due to the additional power of the mini solar system, the currents from the utility grid and the mini solar system can now add up. However, the currents are not detected by the line circuit breaker, so theoretically an overload can occur. You can use the following formula to determine whether the existing line with your circuit breaker is sufficiently dimensioned:

Iz indicates the current carrying capacity of the line, which should be greater than the sum of the rated current of the protective device (circuit breaker in amperes) and the generating equipment (power in amperes). Both Iz and Ig can be found in the following table for the example application below.

  • Iz = In + Ig
  • Iz Permissible current carrying capacity of the line
  • In Rated current of the protective device (circuit breaker)
  • Ig rated current of the power generation system

Load capacity of copper lines
Load capacity of copper cables and lines for fixed installation in buildings 1.5mm2 nominal cross-section; at ambient temperature 25°C, with 2 loaded cores*.


Installation method

| On thermally insulated walls| In electrical installation pipes| ****

On walls

| ****

In the air

---|---|---|---|---
Current carrying capacity Iz of the conductors of the final circuit in amperes| 16,5| 17,5| 21| 23
Maximum rated current Ig of the power generation system with

16A circuit breaker

| 0,5| 1,5| 5| 7
Maximum rated current Ig of the power generation system with

13A circuit breaker

| 3,5| 4,5| 8| 10
Photovoltaic system| one solar module| two solar modules| up to 3 × 115W| from 4 × 115W
max. current load in amperes| 1.3| 2.6| 1.3| 2.6

The example from the table is based on two loaded copper lines with a nominal cross-section of 1.5mm2, which reflects the line in a typical German household. In the case of a larger cross-section or a different cable type, the permissible current-carrying capacity is different, so this must be considered separately, by DIN VDE 0298-4.

Technaxx-TX-248-Solar-Balcony-Power-Plant-600W-WiFi-
FIG-9

Determination of the line reserve
If the cable is a copper cable with a core cross-section of 3×1.5mm2, then the cable is designed for a continuous load of 16.5A (in thermally insulated walls at 25°C). The free capacity is the difference between the line with 16.5A and the circuit breaker with 16A. The free capacity is therefore 0.5A in thermally insulated walls. If the solar power exceeds the current of 0.5A, then the circuit breaker should be replaced with a smaller one to comply with the requirements of the DIN VDE 2948-4 standard. By exchanging the fuse for a smaller 13A fuse, 13A can now still be drawn from the power grid, resulting in free capacity for the power line with a difference of 3.5A. The power of the mini solar system could therefore be up to 805W. In the example (right half of the picture), the power of the mini solar system is 2.6A/600W, which complies with the permissible load.

Further safety instructions

  • Only connect the mini solar system to a permanently connected socket, never to a multiple socket.
  • If you still have older screw fuses installed, it is mandatory to replace them from 16A to the next smaller fuse.

Support
Service phone No. for technical support: 01805 012643 (14 cent/minute from German fixed-line and 42 cent/minute from mobile networks). Free Email: support@technaxx.de
The support hotline is available Mon-Fri from 9 am to 1 pm & 2 pm to 5 pm

Care and maintenance

  • Clean the device only with a dry or slightly damp, lint-free cloth.
  • Do not use abrasive cleaners to clean the device.

Declaration of Conformity
The EU Declaration of Conformity can be requested at the following address: www.technaxx.de/ (in the lower bar “Declaration of Conformity”).

Disposal

  • Disposal of the packaging. Sort packaging materials by type upon disposal.
  • Dispose of cardboard and paperboard in the waste paper. Foils should be submitted for recyclable collection.

Disposing of old equipment (Applies in the European Union and other European countries with separate collection (collection of recyclable materials) Old equipment must not be disposed of with household waste! Every consumer is required by law to dispose of old devices that can no longer be used separately from household waste, e.g. at a collection point in his or her municipality or district. This ensures that the old devices are properly recycled and that negative effects on the environment are avoided. For this reason, electrical devices are marked with the symbol shown here.

FAQ

  • Q: What should I do if my installation exceeds 600W?
  • A: According to the German Federal Network Agency, installations exceeding 600W may only be carried out by electrical contractors. Contact a specialist electrical company for assistance.
  • Q: Can I modify the micro inverter?
  • A: No, tampering with or manipulating the micro-inverter or other parts of the equipment is not recommended as it can lead to damage.
  • Q: How should I handle the device to avoid electric shock?
  • A: Follow the safety instructions provided. Disconnect the plug connection only when the device is de-energized and ensure the power supply is switched off before carrying out visual inspections or maintenance work.

Made in China

  • Distributed by:
  • Technaxx Deutschland GmbH & Co. KG Konrad-Zuse-Ring 16-18,
  • 61137 Schöneck, Germany
  • Solar Balcony Power Plant 600W WiFi TX-248

Model: TX-248; Article No. 5074; 06/2023