femometer FC-IR206 Infrared Thermometer User Manual

June 15, 2024
Femometer

femometer FC-IR206 Infrared Thermometer

femometer-FC-IR206-Infrared-Thermometer-product

Information

Specifications:

  • Manufacturer: Shenzhen Finicare Co.Ltd
  • Address: 201,No.50, the 3rd Industrial Park, Houting Community Shajing Street, Bao’an District Shenzhen 518104 China
  • Email: [email protected]
  • Made in China
  • Manual Ver.: V1.0
  • Issuing Date: 03/03/2021
  • Model: FC-IR206

Product Description

The thermometer consists of a shell, an LCD screen, a measure button, a beeper, an infrared temperature sensor, and a Microprocessor.

Display Description

  • Temperature value
  • Room/object mode
  • Battery level
  • Forehead temperature mode
  • Mute / Un-mute
  • Celsius degrees
  • Fahrenheit degree
  • Memory recall

Product Usage Instructions

How to use your thermometer:

  1. When using the thermometer for the first time, please load the batteries.
  2. Hold the thermometer within 0-1.5 inches (0-3 cm) of theforehead and aim it at the center.
  3. Start measuring with a short press of the Measure button.
  4. Read the temperature value displayed on the LCD screen.

If the eyebrow area is covered with hair, sweat, or dirt, please clean the area beforehand to improve reading accuracy. Always check if the lens is clean. Make sure the user and the thermometer have been in the same room for at least 30 minutes prior to the measurement. After each measurement, clean the temperature probe with a soft cloth and put the thermometer in a dry and well-ventilated place. Wait at least 10 seconds between each measurement. It is dangerous to make a self-diagnosis or self-treatment based on the obtained measurement results. For such purposes, please consult a doctor.

Read your temperature :

To indicate a temperature reading, the thermometer uses the forehead mode.

Switching between mute and un-mute:

When the thermometer is turned on, press the Mute / Un-mute button to switch between mute and un-mute. The mute/unmute function is switchable in the forehead mode but not switchable in the object/room temperature mode.

Caution

  1. All memory records will be lost when uninstalling or reinstalling the battery.
  2. All settings will revert to default when uninstalling the battery. If you need to adjust the settings, please power on and make the new settings.
  3. Replace the battery by sliding the battery cover off along the marked direction. Put two AAA batteries correctly into the compartment.
  4. Remove the batteries if the thermometer will not be used for more than two months.

Troubleshooting and Symbols

Troubleshooting:

Symptom Possible Cause Description & Solution
Failed to power on. The battery level is too low. Replace with a new

battery.
The reading is too low.| |
The reading is too high.| |

FAQ

Q: What should I do if I suspect any product issues during the warranty period?

Introduction and Intended Use

  • Thank you for purchasing this Non-contact forehead Infrared Thermometer. The device has been designed for accurate, safe and fast temperature measurements via the forehead.
  • Please read these instructions carefully before using this product and keep the instructions and thermometer in a safe place.

Intended Use

The Non-contact Infrared Thermometer is intended for the measurement of human body temperatures. The forehead mode is suitable for people of all ages.

Package contents

  • 1 Infrared Thermometer
  • 1 Pouch
  • 2 Batteries(AAA)
  • 1 Operating Manual

Warnings and precautions

  1. Keep out of reach of children under 12 years.
  2. Never immerse the thermometer into water or other liquids (as it’s not waterproof). For cleaning and disinfecting, please follow the instructions in the ‘Care and cleaning’ section.
  3. Never use the thermometer for purposes other than those it is designed for. Please follow the safety precautions when using on infants and children.
  4. Keep the thermometer away from direct exposure to the sun and keep in a dust- free, dry and well-ventilated area, at a temperature between 10°C (50°F)-40°C (104°F). Do not use the thermometer in high humidity environments. (>95% RH)
  5. Do not use the thermometer if there are signs of damage on the measuring sensor or on the device itself. If damaged, do not attempt to repair the device. Contact the retailer.
  6. This thermometer consists of high-quality precision parts. Do not drop the device. Protect it from impact. Do not twist the instrument or the measuring sensor.
  7. Please consult your doctor if you see symptoms such as unexplained vomiting, diarrhea, dehydration, changes in appetite or activity, seizure, muscle pain, shivering, stiff neck, pain when urinating, etc., even in the absence of fever.
  8. Even in the absence of fever, those who exhibit a normal temperature may still need to receive medical attention. People who are on antibiotics, analgesics, or antipyretics should not be assessed solely on temperature readings to determine the severity of their illness.
  9. Temperature elevation may signal a serious illness, especially in adults who are old, frail, have a weakened immune system, or babies and infants. Please seek professional advice immediately when there is a temperature elevation and if you are taking temperature for those who are:
    • Over 60 years of age (fever may be blunted or even absent in elderly patients)
    • Have diabetes mellitus or a weakened immune system (e.g., HIV positive, cancer, chemotherapy, chronic steroid treatment, splenectomy)
    • Bedridden (e.g., nursing home patient, stroke, chronic illness)
    • A transplant patient (e.g., liver, heart, lung, kidney)
  10. This thermometer is not intended for pre-term babies or small-forgestational age babies. This thermometer is not intended to interpret hypothermic temperatures. Do not allow children to take their temperature unattended.
  11. Use of this thermometer is not intended as a substitute for consultation with your physician or paediatrician. It is for household use only.
  12. Clean the thermometer probe after each use.
  13. Do not use the thermometer on newborns or for continuous temperature monitoring purposes.
  14. Do not take a measurement while or immediately after nursing a baby.
  15. Patients should not drink, eat, or be physically active before/while taking the measurement.

Product Information

Product Description

  • The thermometer consists of a shell, an LCD screen, a measure button, a beeper, an infrared temperature sensor, and a Microprocessor.

Product Description

  1. Indicator light
  2. LCD display screen
  3. Measure button
  4. Memory button
  5. Probe
  6. Mute / Un-mute button
  7. Rating label
  8. Battery cover

Display description

  1. Temperature value
  2. Room/object mode
  3. Battery level
  4. Forehead temperature mode
  5. Mute /Un-mute
  6. Celsius degrees
  7. Fahrenheit degree
  8. Memory recall

How to use your thermometer

Temperature taking tips

Which values are normal?

Infrared Thermometer measures the body temperature based on the infrared energy emitted from the eardrum or the forehead. Users can quickly get measurement results after positioning properly the temperature probe in the ear canal or forehead.

Normal body temperature is a range. The following tables shows that this normal range also varies by site. Therefore, readings from different site should not be directly compared. Tell your doctor what type of thermometer you used to take your temperature and on what part of the body. Also, bear this in mind if you are diagnosing yourself.

| Measurements
---|---
Forehead temperature| 97.0°F to 99.5°F (36.1°C to 37.5°C)
Ear temperature| 96.4°F to 100.4°F (35.8°C to 38.0°C )
Oral temperature| 95.9°F to 99.5°F (35.5°C to 37.5°C )
Rectal temperature| 97.9°F to 100.4°F (36.6°C to 38.0°C)
Axillary temperature| 94.5°F to 99.1°F (34.7°C to 37.3°C)

Temperature taking tips

  1. It is important to know each individual’s normal temperature when they are well. This is the only way to accurately diagnose a fever. Record readings twice a day (early morning and late afternoon). Take the average of the two temperatures to calculate normal oral equivalent temperature. Always take the temperature in the same location, since the temperature readings may vary from different locations on the forehead.
  2. A child’s normal temperature can be as high as 99.9°F (37.7ºC) or as low as 97.0°F (36.11ºC). Please note that this unit reads 0.9°F (0.5ºC) lower than a rectal digital thermometer.
  3. Holding the thermometer for too long in the hand before taking a measurement can cause the device to warm up. This means the measurement could be incorrect.
  4. Patients and the thermometer should stay in steady-state room condition for at least 30 minutes.
  5. Before placing the thermometer sensor onto the forehead, remove dirt, hair, or sweat from the forehead area. Wait 10 minutes after cleaning before taking measurement
  6. Use an alcohol swab to carefully clean the sensor and wait for 5 minutes before taking a measurement on another patient. Wiping the forehead with a warm or cool cloth may impact your reading. It is advised to wait 10 minutes before taking a reading.
  7. In the following situations it is recommended that 3-5 temperatures in the same location be taken and the highest one taken as the reading:
    • Newborn infants in the first 100days.
    • Children under three years of age with a compromised immune system and for whom the presence or absence of fever is critical.
    •  When the user is learning how to use the thermometer for the first time until he/she has familiarized himself/herself with the instrument and obtains consistent readings.

How to use your thermometer

When using the thermometer for the first time, please load the batteries.

  1. Hold the thermometer within 0-1.5 inches (0-3 cm) of the forehead and aim it at the center, start measuring with a short press of “Measure” button, then you can read the value.
  2. a measurement can cause the device to warm up. This means the measurement could be incorrect.

NOTE: The forehead measurement is an indicative reading. The measured forehead temperature can fluctuate up to 1 ºF/0.5 ºC from your actual body temperature. Please be aware of the factors that influence the accuracy as described in the section “Temperature taking tips” and WARNINGS AND PRECAUTIONS”.

warning

If the eyebrow area is covered with hair, sweat or dirt, please clean the area beforehand to improve the reading accuracy.

  • Always check if the lens is clean.
  • Always make sure the user and the thermometer will have been in the same room for at least 30 minutes prior to the measurement.

Take room/object temperature

  • When the thermometer is power off, long press the Memory button for 3 seconds until it shows “ “.
  • Then press the Measure button to measure.
  • Keep the thermometer about 1-1.5 inches(1-  3cm) away from the object.Press and release  the Measure button in 1 second, the beep is heard, you can now read the value.

After a measurement

  • Once the reading has been completed, remove the thermometer away from the forehead and observe temperature.
  • After each measurement, you can enter the recall mode and query earlier temperature readings.
  • Do not hold the thermometer for a long time, because it is sensitive to the ambient temperature

Read your temperature

To indicate a temperature reading. In forehead mode.

  • If 89.6°F≤T≤99.2°F(32°C≤T≤37.3°C), the green light will last for 3 seconds, with one long beep.
  • If 99.3°F≤T≤100.3°F(37.4°C≤T≤37.9°C), the orange light will last for 3 seconds, with 3 short beeps, and the value in LCD flickers, which is a warning that you may have a light fever.
  • If 100.4°F≤T≤109.2°F(38°C≤T≤42.9°C), the red light will last for 3 seconds, with 5 short beeps, and the value in LCD flickers, which is a warning that you may have a high fever.
  1. Switching between mute and un-muteWhen the thermometer is turned on, press the Mute /Un-mute button to switch from un-mute to mute.
    • The mute/unmute function is switchable in the forehead mode, it is not switchable in the object/room temperature mode.
  2. Checking 35 sets of memory data When the thermometer is turned on or power off, by press the Memory button to go to the memory mode, press this button again to check the 35 sets of memories one by one. If no value, it will display “—M”.
  3. ºF/ºC conversion
    • Open the battery cover, use the toggle switch to change the ºC/ ºF.
  4. Temperature compensation adjustment
    • When the thermometer is turn on, both press the Mem&Mute/Un-mute button, display ” ” , then go to the temperature compensation mode. By pressing the Mem button to increase the temperature from  ±0.0ºC(ºF) to ±2.0ºC(ºF).
    • Note: All the future temperature you are taking will be automatically added the value you are adjusted.
  5. To turn off
    • The unit will shut down automatically after 10±1 seconds of no use.
    • Or you can keep pressing the Measure button for 8 seconds.

Caution

  1. All memory records will loss when uninstall or reinstall the battery.
  2. All settings will come to default when uninstall the battery. If need adjust the settings, please power on and make the new settings.
  3. Replace the battery.

Slide the battery cover off along the marked direction. Put two AAA batteries correctly into the compartment.

WARNING: Remove the batteries if the thermometer will not be used for more than two months.

Troubleshooting and Symbols

Troubleshooting

Symptom Possible Cause Description & Solution

Failed to power on.

| The battery level is too low.| Replace with a new battery
Polarities of the batteries are reversed.| Ensure the batteries are in the right position
The thermometer is damaged| Contact dealer



The reading is too low

| The lens of the probe is dirty.| Clean the lens with a cotton swab.
The distance of the item and target is too far| Keep the thermometer in contact with forehead, or put the probe into the Ear Canal.
You have just come from a cold environment| Stay in a warmer room for at least 30 minutes before taking a reading
The reading is too high| You have just come from a hot environment.| Stay in an adequately cool room for at least 30 minutes before taking a reading
| The ambient temperature is not in range.| 3 short beeps and red indicator light3 seconds. Take a measurement under an ambient temperature between 50.0°F(10°C ) and 104°F (40°C).
| ****

Memory Error

| 3 short beeps and red indicator light for 3 seconds. Contact dealer.
|

In forehead mode,T > 109.2°F (42.9°C)

| ****

3 short beeps and red indicator light for 3 seconds.


| ****

In forehead mode, T < 89.6ºF (32ºC)

| ****

3 short beeps and red indicator light for 3 seconds.

|

2.5V±3% ≤ power voltage

≤ 2.6V±3%

| The battery level is low, it suggests you to replace the battery, but you can continue to use it.
|

The power voltage is lower than 2.5V± 3%.

| It will turn off automatically after 30 seconds. Please replace with a new battery

Symbols

femometer-FC-IR206-Infrared-Thermometer-fig14

Care and cleaning

  1. Cleaning and user maintenance must not be performed by children unless supervised.
  2. Cleaning the device use an alcohol swab or cotton swab moistened with 70% alcohol to clean the thermometer casing and the measuring probe.
  3. After the alcohol has completely dried out, you can take a new measurement (minimum of 10 minutes).
  4. Ensure that no liquid enters the interior of the thermometer.
  5. Never use abrasive cleaning agents, thinners or benzene for cleaning and never immerse the instrumentin water or other cleaning liquids.
  6. Take care not to scratch the surface of the LCD screen.
  7. Remove the batteries from the device beforecleaning.
  8. Clean the device after use with a soft, slightly damp cloth. If they are very dirty, you can also moisten the cloth with a mild soapy solution.
  9. Ensure that no water enters the device. If this happens, only use the device again once it has fully dried out.

Specifications

Product name Infrared thermometer
Power supply DC1.5V×2
Measurement range Forehead: 89.6°F–109.2°F (32.0°C–42.9°C)

Object: 32°F–212°F (0°C–100°C)
Accuracy (Laboratory)| Forehead mode| ±0.4°F/±0.2°C
Object mode| ±1.8°F/±1.0°C
Display resolution| 0.1°F/0.1°C
Measuring distance| 0 -1.5 inches (0-3cm)
Automatic shutdown| 10s±1s
Memory| 35 groups of measured temperature.
Battery| 2AAA, can be used for more than 3000 times
Weight & Dimension| 80g (without battery),39
150*50mm
Operating conditions| Operating environment: 10ºC-40ºC, ≤85%RH Relative Humidity: ≤85% moisture condensation Atmospheric pressure: 70 – 106kPa
Storage| Temperature: -20°C~55°CRelative Humidity: ≤95% moisture condensation atmospheric pressure: 70 – 106kPa
Device Life| 5 Years

EMC information

IEC 60601-1-2: 2014 ME EQUIPMENT and ME SYSTEMS identification, marking and documents for Class B product The ME EQUIPMENT or ME SYSTEM is suitable for home healthcare environments and so on.

Warning : Don’t near active HF surgical equipment and the RF shielded room of an ME system for magnetic resonance imaging, where the intensity of EM disturbances is high.

Warning : Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally.

Warning: Use of accessories, transducers and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation.”

Warning : Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer
than 30 cm (12 inches) to any part of the Infra-red Thermometer (FC-IR206), including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result.

If any : a list of all cables and maximum lengths of cables (if applicable), transducers and other ACCESSORIES that are replaceable by the RESPONSIBLE ORGANIZATION and that are likely to affect compliance of the ME EQUIPMENT or ME SYSTEM with the requirements of Clause 7 (EMISSIONS) and Clause 8 (IMMUNITY).
ACCESSORIES may be specified either generically (e.g. shielded cable, load impedance) or specifically (e.g. by MANUFACTURER and EQUIPMENT OR TYPE REFERENCE).

If any : the performance of the ME EQUIPMENT or ME SYSTEM that was determined to be ESSENTIAL PERFORMANCE and a description of what the OPERATOR can
expect if the ESSENTIAL PERFORMANCE is lost or degraded due to EM DISTURBANCES (the defined term “ESSENTIAL PERFORMANCE” need not be used).
Technical description:

  1. all necessary instructions for maintaining BASIC SAFETY and ESSENTIAL PERFORMANCE with regard to electromagnetic disturbances for the excepted service life.
  2. Guidance and manufacturer’s declaration -electromagnetic emissions and Immunity

TABLE 1

Guidance and manufacturer’s declaration – electromagnetic emissions

Emissions test| Compliance
RF emissions CISPR 11| Group 1
RF emissions CISPR 11| Class B
Harmonic emissions IEC 61000-3-2| N/A
Voltage fluctuations/ flicker emissions IEC 61000-3-3| N/A

TABLE 2

Guidance and manufacturer’s declaration – electromagnetic Immunity

Immunity Test| IEC 60601-1-2 Test level| Compliance level
Electrostatic discharge (ESD) IEC 61000-4-2| ±8 kV contact ±2 kV, ±4 kV,±8 kV, ±15 kV air| ±8 kV contact ±2 kV, ±4 kV,±8 kV, ±15 kV air
Electrical fast transient/ burst IEC 61000-4-4| Power supply lines:±2 kV input/output lines:

±1 kV 100 kHz repetition

frequency

|

N/A

SurgeIEC 61000-4-5| line(s) to line(s)±1

kV.line(s) to earth:±2 kV.

| N/A
Voltage dips, short interruptions and voltage variations on power supply input lines IEC 61000-4-11| 0% 0.5 cycle At 0º, 45

º,90 º, 135 º, 180 º, 225

º,270 º and 315 º 0% 1 cycle And 70% 25/30 cycles Single phase: at 0 0%250 cycle

|

N/A

Power frequency magnetic field IEC 61000-4-8| 30 A/m50Hz/60Hz| 30 A/m50Hz/60Hz
Conduced RF IEC61000-4-6| 150KHz to 80MHz: 3Vrms 6Vrms (in ISM andamateur radio

bands) 80% Am at 1kHz

|

N/A

Radiated RF IEC61000- 4-3| 10 V/m80 MHz – 2,7

GHz80 % AM at 1 kHz

| 10 V/m80 MHz – 2,7

GHz80 % AM at 1 kHz

NOTE UT is the a.c. mians voltage prior to application of the test level.

TABLE 3

Guidance and manufacturer’s declaration – electromagnetic Immunity

“Radiated RF IEC61000- 4-3

(Test specifications for ENCLOSURE PORT IMMUNITY to RF wireless communicating)”

| Test Frequency (MHz)|

Band (MHz)

|

Service

|

Modulation

|

Modulat

-ion (W)

|

Distance (m)

| IMMUNITY TEST LEVEL(V/

m)

385

| 380

–390

|

TETRA 400

| Pulse modulation 18 Hz|

1,8

|

0.3

|

27

450

|

430–

470

| GMRS 460,FRS460| FM± 5 kHz

deviation 1 kHz sine

|

2

|

0.3

|

28

710|

704

–787

|

LTE Band 13,17

|

Pulse modulation 217 Hz

|

0,2

|

0.3

|

9

745
780
810|

800

–960

| GSM 800/ 900, TETRA

800, iDEN

820, CDMA

850,LTE

Band5

|

Pulse modulation 18 Hz

|

0,2

|

0.3

|

28

870
930
1720|

1700 –1

990

| GSM 1800; CDMA

1900; GSM

1900;DECT; LTE Band1, 3,

4, 25; UMTS

|

Pulse modulation 217 Hz

|

2

|

0.3

|

28

1845
1970

2450

|

2400

–2570

| Bluetooth, WLAN,

802.11b/g/n, RFID 2450,

LTE Band 7

|

Pulse modulation 217 Hz

|

2

|

0.3

|

28

5240|

5100

–5800

|

WLAN

802.11a/n

|

Pulsemodu- lation 217 Hz

|

0.2

|

0.3

|

9

5500
5785

Warranty and After-Sale Service

  • The device is under warranty for 12 months from the date of purchase.
  • The batteries, the packaging, and any damage caused by improper use are not covered by the warranty.

Excluding the following user-caused failures :

  1. Failure resulting from unauthorized disassembly and modification.
  2.  Failure resulting from an unexpected dropping during application or transportation.  Failure resulting from not following the instructions in the operating manual.
  3. If you suspect any product issues during the warranty period, please contact customer services via [email protected]

Manufacturer

  • Shenzhen Finicare Co.,Ltd
  • 201,No.50, the 3rd Industrial Park, Houting Community Shajing Street, Bao’an District Shenzhen 518104 China
  • E-mail: [email protected]

Made in China

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Femometer User Manuals

Related Manuals