WZYBUTA 280W Moving Head Light User Manual
- June 15, 2024
- WZYBUTA
Table of Contents
280W beam lamp
User manual
280W Moving Head Light
(Please read the instruction carefully and manage it before using the product)
Thank you for choosing to use our 280W beam lamp. To use the product correctly
and safely, please read the instruction carefully before installing and using
the product. This instruction contains important installation and application
information. Please strictly follow the operation procedures of the
instruction when installing and operating the product. At the same time,
please keep this instruction manual properly.
Our 280W beam lamp uses a new and beautiful high temperature resistant metal
body. This product is designed and produced in strict accordance with CE
standard. DMX512 signal protocol, which conforms to international standards,
can be used independently or online. It has the characteristics of fast
rotation, low noise and powerful function. It is suitable for small and
medium-sized concert, theatre, studio, night meeting and bar, This product
uses a high-intensity stable Philips 280W bulb. Please carefully dismantle the
package, check whether the product is damaged during transportation after the
removal of the package, and check whether the following contents are complete.
Beam lamp: 1
Lock it up, two
Power cord: 1| Manual: 1
Signal line: 1
---|---
This product is in good condition before leaving the factory. In order to keep
the product in good condition and ensure safe operation, please follow the
safety precautions and the warnings in this manual。
Important: damage caused by not following this instruction is not covered
by the warranty. The supplier shall not be responsible for the product
problems arising therefrom.
If the product has been exposed to extreme unstable temperature environment
(e.g. after transportation), please do not connect the power supply of the
product immediately, because the water drop caused by temperature change may
damage the product. Please use after the product returns to normal
temperature.
This product can be used in the voltage range of 90-240v, is used for indoor
products. Please make sure that the applied ground voltage is not higher than
the range that the product can bear!! The power plug must be plugged into a
class I socket with good protection. Green or magenta conductors must be
grounded.
Please always check the power cord of this product. Make sure that the power
cord is not folded or scratched, and is not connected to other wires! Pay
special attention when connecting the power cord or related wiring. When not
using this product or before cleaning, be sure to unplug the power supply.
Before using the product, please be familiar with the operation function of
the product. Please do not let children or unprofessional people touch the
product. Please do not shake this product. Do not use brute force when
installing or operating the product. Don’t let unprofessional people operate
the product. Most of the damage is due to unprofessional operation.
The product is not equipped with relevant maintenance accessories. Product
maintenance and repair can only be carried out by professionals!
Please do not change this product without authorization, otherwise it may
damage the product, and the damage caused by it is not within the scope of
warranty. Moreover, unprofessional operation may lead to short circuit, burn
or electric shock, etc.
DMX512 signal connection:
The lamp uses DMX512 signal control mode. The control signal of each lamp is
in parallel. When connecting multiple lamp signals, it is better to use double
core shielded cable. When connecting, each lamp is connected through DMX
signal Jack (XLR socket) input and output on the lamp. The 3-core XLR plug
terminals connecting the signal wire of lamps must correspond to each other.
When connecting the lamp signal, the three core XLR plug terminals of the
signal wire of the lamp must correspond to each other. When connecting the
lamp signal, the three core XLR plug terminals of the signal wire of the lamp
must be corresponding to each other, It is recommended to use DMX signal
terminator. It can be avoided that the control signal is damaged due to
electrical dryness. The DMX signal terminal is a 120 ohm 1 W resistance
between two and three pins of an XLR plug and connected to the output socket
of the last lamp Calculation method of lamp starting address code:
The starting address code of the current lamp is equal to (the starting
address code of the previous lamp) + (the number of channels of the lamp)
- The starting address code value of the first lamp is A001
- The basic channel number of the controller should be greater than or equal to the total channel number of the lamp
3: Note: when using any controller, each lamp must have its own starting address code
If A001 is set as the starting address code of a lamp and the channel number of the lamp is 16CH, then
the starting address code of the second lamp will be zero
Set to A017; the starting address code of the third lamp is set to a033; and so on
Different console to decide
Installation instructions of lamps:
2.The lamp can be placed horizontally, slant and upside down. When slant and upside down, the installation method must be paid attention to. Fixed installation of lamp: before positioning the lamp, the stability of the installation site must be ensured. During reverse hanging installation, it must be ensured that the lamp does not fall down on the support frame, and the safety rope should be used to wear the support frame and lamp handle for auxiliary hanging, so as to ensure safety and prevent the lamp from falling and sliding, During the installation and debugging of lamps, pedestrians are not allowed to pass below. Regularly check whether the safety rope is worn and whether the hook screw is loose. If the hanging installation is not stable, the manufacturer will not bear any responsibility for all consequences caused by the falling of lamps 3.
Bulb installation:
- When installing and replacing the bulb, remove the plastic shell of the lamp cap first
- It is recommended to use good quality bulbs
- Do not install or remove the bulb with electricity
- Don’t touch the ball part of the bulb
- Tighten the screws after replacing the bulb
- When the bulb works, it will reach a very high temperature, and the vapor discharge bubble can not continue to supply power. Therefore, it must be completely cooled for 10 minutes after each power failure, otherwise it will lead to high voltage discharge, short circuit and burn out the components on the computer control board
Menu structure
Main interface manual
—-Setting — operation mode
—-DMX address
—-Channel mode
—-X reversal
—-Y reversal
—-XY exchange
—-XY encoder
—-DMX signal
—-Power on light bulb
—-The color wheel changes linearly
—-Restore default settings
—-System software version
—-Reset calibration
—-Sensor monitoring
—-System error
—-Permission setting
—-DMX monitoring
—-Switch between Chinese and English
—-Screen rotation
set up
Option | Description |
---|---|
Operation mode | DMX |
random | Host status: self-propelled and send the signal to the slave |
Voice
control
DMX address| 1-512| Press “OK” to enter the editing state. At this time,
select 100 digits and press the up and down keys to change the address code.
Press “OK” again to select ten digit edit. Press the “OK” key again to select
a bit for editing. Press again to exit editing
Channel mode| Standard 16CH
X reversal| off|
open|
Y reversal| off|
open|
XY exchange| off|
open| Exchange channels of XY axis (including fine
adjustment)
XY encoder| open| Use encoder (optocoupler) to judge out of step and correct
position automatically
off| Position correction without encoder (optocoupler)
DMX signal| keep| Continue to run as before
Clearing| The motor returns to its original position and stops running
Screen| open| Turn off backlight after idle for 30 seconds
saver| off| Backlight always on
Start the bubble| off| Reset directly after power on, no light bulb (need to
use menu or console to light bulb manually)
open| After power on, the bulb will light up automatically, and reset only
after the bulb lights up successfully
Restore default settings| | Press OK to see the confirmation dialog box. Press
OK again to restore the default settings
System information
A layer of password is set in the “permission setting” option to prevent non professionals from disoperation. The default password is up and down. Press “OK” to verify the password.
Option | Description |
---|---|
Software version | |
Reset calibration | X-axis calibration |
reset position of x-axis and y-axis motors can be adjusted to make up
for the error in hardware installation. The adjustment range is – 128 — + 127,
- 0 means no adjustment.
Y-axis calibration
Color calibration
Pattern calibration
Focus calibration
Dimming calibration
Sensor monitoring| | Real time monitoring of various photoelectric switches and Hall sensors on the lamp
System error| | System error message prompt
DMX monitoring| | Real time monitoring of console signal
Error message| Description
---|---
Motor reset failure, serial port error| The driver board did not respond. There is something wrong with the serial communication circuit between the display board and the driver board, or there is something wrong with the driver board.
X-axis reset failed| There is something wrong with X-axis photoelectric switch or X-axis motor
Y-axis reset failed| Y-axis photoelectric switch or y-axis motor has problems
X-axis hall error| There is something wrong with the x-axis
axis hall error| There is something wrong with Y-axis hall
Color disk reset failed| There is something wrong with the color disk or the color disk motor
Reset disk pattern failed| There is something wrong with the pattern disk or the pattern disk motor
Focus reset failed| There is something wrong with the focusing hall or focusing motor
Prism focus reset failure| There is a problem with the prism focusing hall or the prism focusing motor
Bulb control failure| Fail to light or extinguish the bulb, or there is something wrong with the light lighter or bulb
Too long time to soak, please
change!| If the cumulative bubble time exceeds the maximum bubble time set in the Advanced menu, the user will be prompted to change the shot in time. After changing the bubble, clear the bubble time in the “advanced” menu, and the bubble time will be counted again.
Product parameter introduction:
Power supply: ac110 ~ 240V, 50 / 60Hz
Light source: Philips original 280W bulb
Dimming: 0-100% linear dimming
Stroboscopic: double chip stroboscopic (0.5-9 times / s)
Atomization: 0-100% linear atomization
Focusing: electronic focusing
Optical lens: high precision glued optical lens
Prism disk: built in 2 Effect prisms, which can rotate forward and backward.
Color: 1 fixed color disk, 14 colors + white light, rainbow effect, adjustable
speed, half step color effect
Rainbow: 6 high brightness color chips
Fixed image: 1 fixed pattern disk, 17 patterns + white light, can rotate in
two directions
Horizontal scanning: 540 degrees (160bit precision scanning) electronic error
correction
Vertical scanning: 280 degrees (160bit precision scanning) electronic error
correction
Channel mode: 16 international standard DMX512 channels, master-slave mode
Display: color display
Rectifier: electronic rectifier makes the product lighter, brighter, more
stable, more environmental protection and energy saving16CH DMX512
Channel table:
CH | Std.16CH |
---|---|
1 | COLOUR |
2 | STOP/STROBE |
3 | DIMMER |
4 | GOBO |
5 | PRISM1 |
6 | PRISM RT |
7 | PRISM2 |
8 | FROST& IRIS |
9 | FOCUS |
10 | PAN |
11 | PAN FINE |
12 | TILT |
13 | TILT FINE |
14 | PAN-TILT TIME |
15 | RESET |
16 | LAMP CONTROL |
RESET
BIT | EFFECT | Remarks |
---|---|---|
128-255 | COMPLETE RESET | Reset is activated passing through the unused range |
and staying 5 seconds.
0-127| UNUSED RANGE
LAMP CONTROL
BIT | EFFECT | Remarks |
---|---|---|
101-255 | LAMP ON | Lamp switch passing through the unused range and staying 5 |
seconds.
26-100| LAMP OFF
0-25| UNUSED RANGE
COLOUR
BIT | EFFECT |
---|---|
255 | FAST ROTATION |
…… | …… |
201 | SLOW ROTATION |
200 | FAST ROTATION |
…… | …… |
150 | SLOW ROTATION |
145-149 | COLOUR14 + WHITE |
140 | COLOUR14 |
135 | COLOUR13 + COLOUR14 |
130 | COLOUR13 |
125 | COLOUR12 + COLOUR13 |
120 | COLOUR12 |
115 | COLOUR11+ COLOUR12 |
110 | COLOUR11 |
105 | COLOUR10+ COLOUR11 |
100 | COLOUR10 |
95 | COLOUR9+ COLOUR10 |
90 | COLOUR9 |
85 | COLOUR8+ COLOUR9 |
80 | COLOUR8 |
75 | COLOUR7 + COLOUR8 |
70 | COLOUR7 |
65 | COLOUR6+ COLOUR7 |
60 | COLOUR6 |
55 | COLOUR5+ COLOUR6 |
50 | COLOUR5 |
45 | COLOUR4 + COLOUR5 |
40 | COLOUR4 |
35 | COLOUR3+ COLOUR4 |
30 | COLOUR3 |
25 | COLOUR2 + COLOUR3 |
20 | COLOUR2 |
15 | COLOUR1 + COLOUR2 |
10 | COLOUR1 |
5 | WHITE +COLOUR1 |
0 | WHITE |
Maintenance:
Shut down operation: turn off the bulb for 10 minutes before power failure before shutting down. Let the heat dissipating fan quickly discharge the heat generated during the use of the luminaire, thus prolonging the service life of the lamps and lanterns, especially the bulb. In order to ensure that lamps and lanterns can operate stably, they should be kept clean, dismantled, and repaired or started maintenance. Before that, it is very important to confirm whether the power is disconnected. Keeping the lamps clean and clean is very important. Please clean regularly, not only keep the maximum brightness output, but also prolong the service life of lamps and lanterns. It is recommended to use high quality glass cleaning agent and clean soft cloth to clean, and use vacuum cleaner to clean the interior of lamps at least half a year
after-sale service
Attention! When the lamps leave the factory, they all pass the strict quality
inspection, and the packaging is in good condition. Please operate according
to the instruction manual. The machine failure caused by human reasons is not
within the scope of warranty
- The company provides technical consultation for customers all their life
- If the product breaks down and needs to be repaired, please show the product warranty card and fill in the relevant contents truthfully. At the same time, we also hope that customers can feed back the problems of the product to us in time, so that we can improve the product in the first time.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>