Honeywell Home DT4R 1 Channel Wireless Spare Room Thermostat
Product Information
- Product Name:
- DT4R
- Product Website:
- Specifications
- Relay Box: 5(3)A
- Country of Origin: UK
- FAQ
- Q: Do I need to have a permanent live for installation?
- A: No, permanent live is not required for basic boiler installation.
- Q: What is the maximum thickness for the Relay Box installation?
- A: The maximum thickness for the Relay Box installation is 6mm.
- Q: How do I access the Installer Menu?
- A: Press and hold the specified button based on your language to access the Installer Menu.
- Q: How can I perform an RF Communication Test?
- A: Select the RF Communication Test option from the menu and follow the on-screen instructions.
Must be installed by a competent person. To ensure your safety make sure the mains power is switched OFF before accessing wiring.
Application
- On/off boiler (230V)
- Combi boiler
- Heat Pump
- 2-Port Zone Valve
Install the Relay Box
Install the Thermostat
Installer Menu
- Press & hold
- Press once
- Parameters
- RF Settings
- Display Brightness
- Software Version
- Exit
RF Communication Test
The Thermostat and Relay Box in this pack are pre-bound.
Wireless Binding Instructions
https://hwllhome.co/eu-dt4-rf-rebind.
Parameters
- HC Heat, Cool, Heat/Cool Mode H, C, HC
- Ot Minimum On Time 1, 2, 3, 4, 5, 10, 15, 20, 25, 30
- OFt Minimum Off Time 0, 1, 5, 10
- Cr Cycle Rate 3, 6, 9, 12
- tO Temperature Offset -3.0 … +3.0°C (0.0)
- Upper Limit (heat) 19 … 35°C
- Lower Limit (heat) 5 … 19°C
- Upper Limit (cool) 27 … 35°C
- Lower Limit (cool) 5 … 27°C
- EOs Eco Offset -3.0 … +3.0°C (-2.0)
- LC Failsafe Mode 0 = Disabled
- FS Factory Reset 0, 1 = Reset
- End Exit
Scan the QR Codes
CONTACT
- Pittway Sarl, Z.A. La Pièce 6,
- 1180 Rolle, Switzerland
- Country of origin : UK
- © 2023 Resideo Technologies, Inc. All rights reserved.
- The Honeywell Home trademark is used under license from Honeywell International Inc.
- This product is manufactured by Resideo Technologies, Inc. and its affiliates.
- www.resideo.com.
- R32350730-001 B