PRODUCT

Product Information

  • Model: AC350
  • Manufacturer: Vornado Air, LLC
  • Address: 415 East 13th Street, Andover, Kansas 67002
  • Contact: 800.234.0604 [email protected].
  • Specifications
    • Intended Use: Purifying the air in indoor living spaces in the United States and Canada Not intended for commercial or industrial use
    • Product Warranty: Void if directions are not followed
    • Placement: Floor use only, not on elevated surfaces
    • Safety Precautions: Supervision required for children under age 12 and individuals with reduced capabilities

Product Usage Instructions

  • Installation
    • Place the air purifier away from curtains, draperies, tablecloths, and other fabrics to prevent damage to the motor and reduce the risk of fire.
  • Safe Use
    • Avoid circuit overload by following the provided instructions for power usage.
  • Cleaning and Maintenance
    • Clean your air purifier regularly as instructed in the manual.
    • Before cleaning, turn off the power and unplug the device.
    • Do not use gasoline, thinners, solvents, ammonias, or other chemicals for cleaning.
  • Troubleshooting
    • If the device does not power on, check the power connection and ensure it is properly plugged in.
    • If the airflow is low or slow, clean or replace the filters as instructed in the manual.
  • Warranty
    • For warranty information, contact Vornado Air, LLC at 800.234.0604 or [email protected].
  • True HEPA Filtration
    • The air purifier utilizes True HEPA filtration to effectively remove airborne particles and allergens from the indoor environment.
  • Automatic Filter Refill Program
    • The air purifier is equipped with an automatic filter refill program. Follow the instructions provided to ensure timely filter replacement.
  • Filter Replacement
    • Regularly check and replace the filters as instructed in the manual to maintain optimal performance.
  • FAQ (Frequently Asked Questions)
    • Q: What should I do if the device does not turn on?
    • A: First, check the power connection and ensure it is properly plugged in. If the issue persists, contact Vornado Air, LLC for assistance.
    • Q: How often should I clean the air purifier?
    • A: Clean the air purifier regularly as instructed in the manual to maintain its performance. The frequency may vary depending on usage and environmental conditions.
    • Q: Can I use chemicals for cleaning?
    • A: No, do not use gasoline, thinners, solvents, ammonias, or other chemicals for cleaning. Follow the cleaning instructions provided in the manual.

IMPORTANT SAFETY INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS

  • This owner’s guide and any additional inserts are considered part of the product. They contain important information about safety, use and disposal. Before using the product, please familiarize yourself with all operating and safety instructions. Please keep all documents for future reference and pass these documents on, together with the product, to any future owner. See www.vornado.com/circulatorsmanuals. to view, download and print the most current version of these instructions.

INTENDED USE: This product is intended to purify the air in indoor living spaces only in the United States and Canada. This product is not intended for commercial or industrial use. The manufacturer assumes  no responsibility for damage or injury due to unauthorized use orproduct modifi cation. Failure to follow these directions will void the product warranty. This product is intended to be used on the fl oor and not on an elevated surface such as a table or desktop.

  • WARNING: Risk to Children and Impaired Persons
  • Supervision is required during the installation, operation, cleaning and maintenance of this product by children under age 12 and anyone with reduced physical, sensory or mental capabilities. Children should be supervised to ensure that they do not play with the appliance, its parts and packaging material.

INSTALLATION WARNING— To reduce risk of fi re, electrical shock and injury to persons, observe the following:

  • Place this product away from curtains, draperies, tablecloths and other fabrics, since they may be drawn into the product, damage the motor and/or cause a fi re.
  • No part of this product (the appliance, power cord, plug, packaging, etc.) should be placed near furnaces, fi replaces, stoves or other high temperature heat sources. Do not use this product in a window, on an uneven or unstable surface, or near water.
  • The appliance, power supply, power cord and plug cannot come into contact with water. Do not use this product on wet surfaces. Do not use this product in a bathtub or shower or position product where it may fall into a bathtub, laundry, swimming pool or other water container. Do not use this product outdoors or expose it to weather or elements.
  • Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffi c area and where it will not be tripped over. The cord should not hang over edges of counters or be placed where it can be crimped or closed in doors. Place appliance near an easily accessible outlet so the product can be unplugged quickly during an emergency.

SAFE USE WARNING— To reduce risk of fi re, electrical shock and injury to persons, observe the following:

  • WARNING: To reduce likelihood of circuit overload, fi re and electric shock, do not operate with a solid state speed device, such as a dimmer control switch.
  • Do not operate unit if the unit has been dropped or damaged. Do not use this product if it has a damaged power cord or plug. To avoid risk of electrical shock, do not attempt to repair or replace parts. Only original replacement parts may be used. If the power cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualifi ed persons in order to avoid a hazard. Contact Vornado Consumer Service at 1-800-234-0604 (phone) or [email protected]. (email) for further instructions about replacement and repair.
  • Risk of fi re. Your appliance may be equipped with a detachable power supply or a cord/plug with a safety device such as a fuse. Use only the power cord and plug provided.
  • Before plugging power cord into electrical outlet, be sure that all electrical information on the rating label, including voltage, is compatible with your outlet’s power supply.
  • Never use the cord as a handle or otherwise yank, strain or stretch the power cord.
  • While the product is plugged in, do not insert or allow foreign objects to enter any input or output opening as this may cause risk of electric shock or fi re, or damage the product.
  • A loose fi t between wall outlet (receptacle) and plug may cause overheating and distortion of the plug. Discontinue use of the product in this outlet. Contact a qualifi ed electrician to replace loose or worn outlets.
  • This appliance has a polarized plug (one blade is wider than the other.) To reduce the risk of electrical shock, this plug is intended to fi t in a polarized outlet only one way. If the plug does not fi t fully in the outlet, reverse the plug. If it still does not fi t, contact a qualifi ed electrician. Do not attempt to defeat this safety feature.
  • Before moving, repositioning, servicing, cleaning and when not in use, use the product controls to turn off the power and then unplug. To disconnect from outlet, grasp and pull only the plug. Also, power off and unplug if the product will be left unattended for an extended period of time or during electrical storms.

SERVICING WARNING— To reduce risk of fi re, electrical shock and injury to persons, observe the following:

  • Clean your product regularly, only as is instructed in this manual. Prior to cleaning, turn off the power on your product and unplug. Do not use gasoline, thinners, solvents, ammonias or other chemicals for cleaning. Refer to the CLEANING instructions provided.
  • Do not open appliance housing while product is plugged in. To avoid risk of shock, all service and/or repairs must be done by a Vornado Authorized Service Center.

FCC Compliance Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with thelimits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Contact Vornado Customer Service or dealer or an experienced radio/TV technician for help.
  • This Class B digital apparatus complies with Canadian ICES-003.
  • Changes or modifi cations not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Supplier’s FCC Declaration of Conformity

  • Unique Identifi er: Vornado Model AC350
  • Responsible Party: Vornado Air LLC
  • Mailing Address: 415 E. 13th St., Andover, KS 67002
  • Contact: www.vornado.com.

PRODUCT INFORMATION

  1. FRONT PANEL

  2. PLASTIC SUPPORT FILTER FRAME
    The frame secures both Carbon and HEPA fi lters inplace.

  3. CARBON FILTER
    Captures larger initial particles and odors passing through the unit.

  4. HEPA FILTER
    Captures 99.97% of particles 0.3 microns or larger passing through the unit, allowing only fi ltered air back into the environment.

  5. CONTROL PANEL
    Push button controls for easy and intuitive operation.

  6. POWER CORD
    Convenient 6 ft. cord.Vornado-Air-LLC-AC350-Air-Purifier-with-True-HEPA-
Filter-FIG-1 \(1\)

CONTROL PANEL.

Vornado-Air-LLC-AC350-Air-Purifier-with-True-HEPA-Filter-FIG-1
\(2\)

  1. Power, Function ON and OFF by pressing the Power button.
  2. Fan Speed, 3 fan speed settings to meet any need. Select Low, Medium, or High by pressing the Power button until desired speed is illuminated.
    • Note: Dust and allergens are most airborne when persons and pets are active in the room. For best results, set the unit on a higher speed setting during these times for high demand cleaning and circulation. Set the unit to a lower setting for quieter operation when activity is reduced.
  3. Carbon Filter Replacement , Equipped with Replace Carbon filter indicator light to show when it is recommended to change the carbon fi lter. Please refer to FILTER REPLACEMENT for instructions. This feature is controlled by time of use. The light will illuminate after 4,000 hours of run time has accumulated.
  4. HEPA Filter Replacement, Equipped with Replace HEPA fi lter indicator light to show when it is recommended to change the HEPA fi lter. Please refer to FILTER REPLACEMENT for instructions. This feature is controlled by time of use. The light will illuminate after 9,000 hours of run time has accumulated.
    • Note: User environments will differ. The fi lter replacement time is based on average use situations, if you are using the air cleaner in a more demanding environment, you may need to change your fi lter more frequently. In less polluted environments the fi lter life may extend beyond  the notifi cation

USER TIPS

  1. Keep retail carton to store unit when not in use.
  2. Use the hand holds on either side of the unit for easy carrying.
  3. For best results, position the front of the unit (side with logo) towards the center of the room, leaving at least a 6 inch distance away from walls or furniture on every side.
    • Note: For optimum airfl ow, air outlet should be unobstructed. Ensure curtains and other items are far enough away from the unit to not be pulled into the side inlets or interfere with airfl ow.

TRUE HEPA FILTRATION

VORNADO WHOLE ROOM AIR PURIFIERS FEATURE PRECISION TRUE HEPA CALIBRATION

  • Without properly calibrated airfl ow, products with a True HEPA Filter will not achieve their full fi ltration potential.
  • Gaps, poorly sealed fi lter housings, and excessive air velocity all reduce the effectiveness of the product.
  • Independent testing labratory verifi es that the precise calibration of a Vornado Air Purifi er allows it to perform at True HEPA standards.

2 STAGE FILTRATION

  • Carbon fi ltration captures odors and prolongs HEPA fi lter life. HEPA fi ltration captures 99.97% of particles 0.3 microns or larger, to effectively clean large volumes of air.

AUTOMATIC FILTER REFILL PROGRAM

  • A convenient and hassle-free way to recieve regular shipments of Vornado Filters, direct to your door.
  • Eliminate the hassle of remembering to reorder.
  • Maintain the high effi ciencyof your Vornado Purifi er by regularly replacing used Filters with fresh new ones.

How it works:

  • You select a plan and Vornado will send replacement Filters at the recommended maintenance interval.
  • To sign up, visit vornado.com, email [email protected]. or call 1-800-234-0604. Cancel at anytime.

FILTER REPLACEMENT

GENUINE VORNADO FILTERS ARE RECOMMENDED

  • Peak performance is only realized when genuine Vornado Carbon and HEPA fi lters are used. Others may claim to be compatible with Vornado units, but the Vornado Air Purifi er is calibrated to achieve a 99.97% capture rate of particles 0.3 microns or larger, only when used with Vornado Filters.
    • Note: The Front Panel is held in place by magnets, you will need to lift the Front Panel hard enough to overcome the resistance of the magnets.

HOW TO REPLACE YOUR FILTERS

  1. Unplug unit.
  2. Remove Front Panel by lifting up and away from unit.
  3. Remove the Plastic Support Filter Frame by pulling on the center tabs (A). You may need to fl ex the Plastic Support Filter Frame slightly to release the tabs at the top and bottom.
  4. Remove and discard used Filters. Simply take hold of the Carbon Filter at any place along the perimeter and remove. To remove  the HEPA Filter, take hold of the tab (Figure 1) and pull to release.Replace with genuine Vornado Filters. Place the Filters in the unit and gently press around the perimeter of the Filter to ensure secure placement (Figure 2).
    • Note: The HEPA Filter must be placed in the unit before the Carbon Filter. See Product Information for a detailed illustration.
  5. Replace the Plastic Support Filter Frame by securing the bottom 2 tabs into bottom slots (B). Slightly fl ex the Plastic Support Filter Frame to secure the top 2 tabs into the top slots (A).
  6. Replace Front Panel by positioning the Panel slightly above the unit and aligning the tabs of the Front Panel with the holes in the unit (A). Gently press the Front Panel down, sliding into the tab slots and allowing the magnets to securely lock the Front Panel in place. SAFETY SHUT-OFF FEATURE
    • For your protection, the unit is designed to operate only if the Front Panel is in place.
    • Do not attempt to override this safety feature.
    • If, after the Front Panel has been reinstalled, the unit does not operate, remove and reinstall the Front Panel to assure proper placement.
  7. To reset the CARBON fi lter notifi cation – press and hold the REPLACE CARBON button for 3 seconds. To reset the HEPA fi lter notifi cation, press and hold the REPLACE HEPA button for 3 seconds. The light will turn off confi rming the indicator is reset.
    • Note: Do not operate the Air Purifi er without Vornado Carbon and Vornado HEPA Filters in place.

STORAGE

Follow the steps listed below when you are ready to store your unit.

  1. Unplug power cord and bundle loosely.
  2. Lift unit with both hands, using hand holds. (Refer to USER TIPS)
  3. Cover, or place back in retail carton if available. This will prevent the unit from accumulating dust overtime.
  4. Store unit in a cool and dry location.

CLEANING AND MAINTENANCE

HOW TO CLEAN

Because large volumes of air pass through your Vornado Air Purifi er each day, it will need regular cleaning.

  1. Unplug the unit before cleaning.
    • Note: Do not use gasoline, thinners, solvents or other chemicals for cleaning.
  2. Wipe down with a soft, damp cloth. (Figure 1)
  3. Dust or vacuum the interior and along the sides. It is recommended to clean the interior when the Filters are changed. (Figure 2)

Other Maintenance

The motor is permanently lubricated so it needs no service. No other serviceable parts, other than Filters, are contained within the unit.

TROUBLESHOOTING

PROBLEM/POSSIBLE CAUSE AND SOLUTION

Unit fails to power on.|  | Unit is not plugged in. Plug power cord into electrical outlet.
Front Panel may not be properly installed. Remove and reinstall the Front Panel to assure proper placement. Refer to FILTER REPLACEMENT.
Household circuit breaker / ground fault interrupter has tripped or blown a fuse. Reset circuit breaker / ground fault interrupter, or replace fuse. For assistance, contact a licensed electrician.
Unit is damaged or in need of repair. Cease usage and unplug. Contact Consumer Service for assistance.
---|---|---
Air fl ow is weak or slow.|  | Unit set to a low speed setting. Adjust to a higher speed setting. Debris build-up on filter. Check and replace Filters. Airflow is blocked. Remove obstruction.

WARRANTY

We expect this product to be perfect. If you’re not satisfi ed with this product, let us know.

  • Vornado Air LLC (“Vornado”) warrants to the original consumer or purchaser this Vornado® Whole Room Air Purifi er (“Product”) is free from defects in material or workmanship for a period of fi ve (5) years from the date of purchase. If any such defect is discovered within the warranty period, Vornado, at its discretion, will repair or replace the Product at no cost.

For warranty or repair service:

  • Call 1-800-234-0604 or email [email protected]. to obtain a Return Authorization (“RA”) form.
  • Please have or include your Product’s model number and serial number, as well as your name, address, city, state, zip code and phone number when contacting Vornado for warranty service.

After receiving the RA form, ship your Product to:

  • Vornado Air LLC Attn: Warranty & Repair 415 East 13th Street Andover, KS 67002. For your convenience, please have your model number and serial number when contacting
  • Vornado with service inquiries. To assure proper handling, packages must be clearly marked with the RA number.
  • Packages not clearly marked with the RA number may be refused at the receiving dock. Please allow 1-2 weeks for repair and return of your Product after the Product is received.
  • Repairs not covered by the warranty or outside the warranty period will require a fee to cover the cost of materials, labor, handling and shipping.
  • This warranty does not apply to defects resulting from abuse of the Product, modifi cation, alteration, repair or service of the Product by anyone other than Vornado, mishandling, improper maintenance, commercial use of the Product, damages which occur in shipment or are attributed to acts of God.
  • REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY IS THE EXCLUSIVE  REMEDY OF THE CONSUMER.
  • VORNADO SHALL NOT BE LIABLE FOR ANY INCIDENTALOR CONSEQUENTIAL DAMAGES FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ON THIS PRODUCT.
  • EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY.
  • Some states do not allow the exclusion or limitation of incidental or consequential damages, or allow limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you.
  • This warranty gives you specifi c legal rights, and you may have other rights that vary from state to state.
  • All company names and product names are trademarks of their respective owners. © All rights reserved.
  • All technical information, data, and instructions for the installation, connection, and operation contained in these instructions for use correspond to the latest available information at time of printing.
  • The contents of this manual may differ slightly from the actual product. Observe any additional supplements.
  • The manufacturer assumes no responsibility for damage caused by failure to follow these instructions or improper product use. Any such actions will invalidate the product warranty.
  • Any unauthorized product modifi cation, repair by unauthorized repair center, or use of non-approved replacement parts is not recommended and any consequences will not be covered by support services or product warranties.

CONTACT

  • We’re Here To Help
  • 800.234.0604
  • vornado.com.
  • [email protected].
  • Designed, engineered and supported in Andover, KS
  • © 2017 Vornado Air LLC Andover, KS 67002 U.S. Patent Pending. Specifi cations subject to change without notice. Vornado® is a trademark owned by Vornado Air LLC.
  • vornado.com.
  • 800.234.0604
  • [email protected].
  • Vornado Air, LLC
  • 415 East 13th Street, Andover, Kansas 67002
  • 800.234.0604
  • vornado.com.
  • WHOLE ROOM AIR PURIFIER OWNER’S GUIDE
  • model AC350

References