Didsbury 5 Wood Burning Stove Multifuel Ecodesign Stove
Product Information
Specifications
- Date: 01/07/2021
- Version Number: 2021 Issue no.1
- Compliance: EN 13240+Amd2-2004
Identifying Your Stove
1.1 Identifying parts & terminology of your
stove-External
This section provides information on how to identify the
external parts and terminology of your stove. Please refer to page
5 of the user manual for detailed illustrations and
descriptions.
1.2 Identifying parts & terminology of your stove
-Internal
This section provides information on how to identify the
internal parts and terminology of your stove. Please refer to page
6 of the user manual for detailed illustrations and
descriptions.
Installation Guide
2. Warnings
This section contains important warnings that must be followed
during the installation process. Please refer to page 7 of the user
manual for detailed information.
3. Health & Safety
This section provides guidelines for health and safety practices
during the installation process. Please refer to page 7 of the user
manual for detailed information.
4. Installation Requirements
4.1 Hearth & Recesses
This section outlines the requirements for the hearth and
recesses during the installation process. Please refer to page 8 of
the user manual for detailed information.
4.2 Combustible Materials
This section provides information on handling combustible
materials during the installation process. Please refer to page 8
of the user manual for detailed information.
4.3 Air For Combustion
This section explains the importance of proper air circulation
for combustion. Please refer to page 9 of the user manual for
detailed information.
Flue & Chimneys
This section provides requirements and guidelines for the flue
and chimneys. Please refer to page 10 of the user manual for
detailed information.
Commissioning The Stove
7.1 Checklist
This section provides a checklist to follow when commissioning
the stove. Please refer to page 14 of the user manual for detailed
information.
User Guide
8. Warnings
This section contains important warnings that must be followed
during the usage of the stove. Please refer to page 15 of the user
manual for detailed information.
8.2 Health & Safety
This section provides guidelines for health and safety practices
during the usage of the stove. Please refer to page 16 of the user
manual for detailed information.
8.3 Smoke Control Areas (The Clean Air Act 1993 & Smoke
Control Areas)
This section provides information on smoke control areas and
regulations. Please refer to page 16 of the user manual for
detailed information.
Recommended Fuels
9.1 Wood
This section provides information on recommended wood fuels for
the stove. Please refer to page 17 of the user manual for detailed
information.
9.2 Mineral Smokeless Fuel (Solid Fuel)
This section provides information on recommended mineral
smokeless fuels for the stove. Please refer to page 17 of the user
manual for detailed information.
Before You Start
10.1 Pointers Before Use
This section provides important pointers to consider before
using the stove. Please refer to page 18 of the user manual for
detailed information.
Further Resources / Information
15.1 Information
This section provides additional resources and information
related to the stove. Please refer to page 31 of the user manual
for detailed information.
15.2 Specifications
This section provides detailed specifications of the stove.
Please refer to page 31 of the user manual for detailed
information.
Guarantee
16.1 Guarantee
This section outlines the guarantee for the stove. Please refer
to page 32 of the user manual for detailed information.
16.2 Terms and Conditions
This section provides the terms and conditions related to the
guarantee. Please refer to page 32 of the user manual for detailed
information.
16.3 General
This section contains general information related to the
guarantee. Please refer to page 33 of the user manual for detailed
information.
FAQ (Frequently Asked Questions)
Q: How do I identify the external parts of my
stove?
A: To identify the external parts of your stove, please refer to
page 5 of the user manual for detailed illustrations and
descriptions.
Q: What are the installation requirements for the hearth
and recesses?
A: The installation requirements for the hearth and recesses are
outlined on page 8 of the user manual. Please refer to that page
for detailed information.
Q: What fuels are recommended for the
stove?
A: Wood and mineral smokeless fuel (solid fuel) are recommended
for the stove. Please refer to page 17 of the user manual for more
information on recommended fuels.
Q: What are the important pointers to consider before
using the stove?
A: Important pointers to consider before using the stove are
provided on page 18 of the user manual. Please refer to that page
for detailed information.
Q: Where can I find further resources and information
about the stove?
A: Additional resources and information about the stove can be
found on page 31 of the user manual. Please refer to that page for
more information.
Q: What is the guarantee for the stove?
A: The guarantee for the stove is outlined on page 32 of the
user manual. Please refer to that page for detailed
information.
Date: 01/07/2021 Version Number: 2021 Issue no.1
PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE
EN 13240+Amd2-2004
Date: 01/07/2021 Version Number: 2021 Issue no.1
Didsbury Stove Collection
Congratulations on the purchase of your new stove! More than 30 years of
experience has been put into the development of your stove to ensure ultimate
performance and years of trouble free use and enjoyment. Every detail of your
stove has been carefully designed and engineered which is why we are so
confident in the reliability of our products. Your stove is built to the
highest standard of craftsmanship using the best materials and the most modern
equipment available. It is a highly efficient and sophisticated piece of
machinery and when properly installed and operated it should provide a
lifetime of heating satisfaction. Should you have any questions about your
stove which are not covered by this manual, please contact your retailer in
your area or visit our website: www.flue-ducting.co.uk, which offers a wealth
of information on how to care for and get the best from your stove. Please
ensure that you read these instructions in full and understand them before
operating your stove. Flue & Ducting has a policy of continuous product
development and therefore we reserve the right to amend specifications without
prior notice. Due to printing cycles, items or options may be described before
they are generally available or after they have ceased.Please check with your
retailer or dealer if you are unsure about any aspect of your stove,its
installation or correct use.
Page 2
Date: 01/07/2021 Version Number: 2021 Issue no.1
Contents
1 Identifying your stove 1.1 Identifying parts & terminology of your stove-
External…………………………………………….. 5 1.2 Identifying parts & terminology of your
stove -Internal…………………………………………….. 6
INSTALLATION GUIDE
2 Warnings 2.1 Important Warnings……………………………………………………………………………………………… 7
3 Health & Safety 3.1 Health and Safety
Practice…………………………………………………………………………………….. 7
4 Installation Requirements 4.1 Hearth &
Recesses……………………………………………………………………………………………….. 8 4.2 Combustible
Materials………………………………………………………………………………………….. 8 4.3 Air For
Combustion……………………………………………………………………………………………… 9
5 Flue & Chimneys 5.1 Requirements……………………………………………………………………………………………………… 10
6 Installing The Stove 6.1 Removing The
Door……………………………………………………………………………………………. 11 6.2 Removing The Throat Plate &
Liners……………………………………………………………………. 11 6.3 Fitting The Spigot
Outlet……………………………………………………………………………………… 11 6.4 Fitting The Hot Plate (Blanking
Plate)…………………………………………………………………… 12 6.5 Connecting The Spigot Outlet To The
Flue system…………………………………………………. 12 6.6 Firebox Liner
Panels……………………………………………………………………………………………. 12 6.7 Optional Accessories
………………………………………………………………………………………….. 12 6.8 Smoke Control Areas (The Clean Air
Act 1993 & Smoke Control Areas)…………………. 13
7 Commissioning The Stove 7.1
Checklist……………………………………………………………………………………………………………. 14
USER GUIDE 8 Warnings 8.1 Important
Warnings……………………………………………………………………………………………. 15 8.2 Health &
Safety…………………………………………………………………………………………………. 16 8.3 Smoke Control Areas (The
Clean Air Act 1993 & Smoke Control Areas)………………… 16
9 Recommended Fuels 9.1 Wood……………………………………………………………………………………………………………….. 17
9.2 Mineral Smokeless Fuel (Solid Fuel)……………………………………………………………………. 17
Page 3
Date: 01/07/2021
Version Number: 2021 Issue no.1
10 Before You Start 10.1 Pointers Before
Use…………………………………………………………………………………………..18
11 Air Inlet Controls 11.1 Air
inlet……………………………………………………………………………………………………………19 11.1.1 Primary air control
location …………………………………………………………………………….19 11.1.2 Primary air
control………………………………………………………………………………………….20 11.1.3 Secondary air
control………………………………………………………………………………………20 11.1.4 Tertiary
air……………………………………………………………………………………………………..21
12 Lighting Your Stove 12.1.1 Smoke control
areas……………………………………………………………………………………….22 12.1.2 Fuel
overloading…………………………………………………………………………………………….22 12.1.3 Operation with door
left open…………………………………………………………………………..22 12.1.4 Dampers / Air controls left
open……………………………………………………………………… 22 12.2 Burning
wood………………………………………………………………………………………………….. 22 12.3 Burning solid
fuel……………………………………………………………………………………………..23 12.4 Warning – Fume / Smoke
emissions…………………………………………………………………… 24 12.5 Refueling on to a low fire
bed…………………………………………………………………………… 24 12.6 Smoke Control
Area…………………………………………………………………………………………. 25 12.7 Typical burn for nominal
output………………………………………………………………………… 25
13 Further Information For All Stove owners 13.1 Reduced burning (Slow
combustion)………………………………………………………………….26 13.2 Over
firing………………………………………………………………………………………………………26 13.3 Chimney
fires………………………………………………………………………………………………….26 13.4 Periods of non-use (Summer
months)…………………………………………………………………26 13.5 Multi Flue Kit Optional
Accessories…………………………………………………………………..27 13.5.1 Riddling the
firebox……………………………………………………………………………………….27 13.5.2 Ash
removal………………………………………………………………………………………………….27 13.6 Replacement
parts…………………………………………………………………………………………….28 13.7
Classification…………………………………………………………………………………………………..28 13.8 Adverse weather
conditions………………………………………………………………………………28 13.9 Door
glass……………………………………………………………………………………………………….29 13.10 Fire door handle /
riddle handle………………………………………………………………………..29
14 Care for your stove 14.1 Adjusting the door
hinges…………………………………………………………………………………30 14.2 Liners /
firebricks…………………………………………………………………………………………… 30 14.3 Throat
plate…………………………………………………………………………………………………….30 14.4 Fire door
seal…………………………………………………………………………………………………..31 14.5 Cracked
glass…………………………………………………………………………………………………..31 14.6 Chimney / flue sweeping
………………………………………………………………………………….31
15 Further resources / information 15.1
Information……………………………………………………………………………………………………..31 15.2 Specifications
………………………………………………………………………………………………… 31
16 Guarantee 16.1 Guarantee………………………………………………………………………………………………………..32 16.2
Terms and conditions………………………………………………………………………………………..32 16.3
General……………………………………………………………………………………………………………33
Technical data……………………………………………………………………………………………………34-37
Page 4
Date: 01/07/2021 Version Number: 2021 Issue no.1
1 Identifying your stove
1.1 Identifying parts & terminology of your stove -External
Fire Door Assembly
Top Flue Outlet (NOTE: Top & Rear Flue outlets are Interchangeable & Will Depend Upon Installation.)
Fire Door Handle
Air Controls
Heat Insulation Plate
Rear Flue Outlet (NOTE: Top & Rear Flue outlets are Interchangeable & Will Depend Upon Installation.)
Direct Air Cover
Air Channel Cover
Page 5
Date: 01/07/2021 Version Number: 2021 Issue no.1
1.2 Identifying parts & terminology of your stove–Internal
Firebox Liners (Sides & Rear)
Flue Retainer
Fire Door Glass
Throat Plate Page 6
Tertiary Outlet Within Rear Liner
Date: 01/07/2021 Version Number: 2021 Issue no.1
2 Warnings
2.1 Important Warnings It is a LEGA REQUIREMENT that the installation of all
new or replacement,wood or solid fuel heating appliance(s),obtain building
control approval, from your local authority or that the installation work must
be carried out through a government approved competent persons scheme.A list
of all competent person schemes can be found : https://www.gov.uk/quidance
/competent-person-scheme-current-schemes-and-how-schemes-areauthorised
All local regulations,including those referring to National & European
standards,need to be complied with when installing the appliance.
For the appliance installation,please refer to BS 8303-3:1994 as the code of
practice for installation of domestic heating and cooking appliances burning
solid mineral fuel.
This stove should not be installed into a chimney or flue system that serves
other heating appliances.
The manufacturers instructions must not be taken as overriding statutory
requirements.
Any form of an extraction fan must not be fitted into the same room as the
appliance.
Flue & Ducting Ltd will not be responsible for any consequential or incidental
loss or injury however caused. Any further warnings in this document will be
marked out in a box such as this one. Ignoring the warnings,could lead to
damage / injury to persons and / or property.
3 Health&Safety
3.1 Heath & Safety Practice Before any installation work is undertaken
consideration must be given to the Heath and Safety at work Act 1974.Safe
working practices should be followed at all times.
Please consult health and safety guidelines for advice on handling heavy and /
or large items.
During installation ensure that adequate precautions are taken to avoid
unnecessary risk to yourself or any householder.
The danger from the caustic nature of fire cement,should be avoided by using
these accepted methods:Wear gloves when handling fire cement.Wear goggles when
chiselling or looking up chimneys.
This stove contains no asbestos.Any possibility of disturbing asbestos in the
course of the installation then always seek specialist guidance and use
appropriate protective equipment for its removal.
Page 7
Date: 01/07/2021 Version Number: 2021 Issue no.1
4 Installation Requirements
4.1 Hearths and Recesses The stove should be installed on a surface with
adequate load bearing capacity. If the existing construction does not meet
this prerequisite,suitable measures(e.g. load distributing plate) should be
taken to achieve it. Please pay particular attention when examining existing
building work for suitability to meet the following requirements.
When installing a stove, hearths should have a sufficiently flat surface to
allow a firm seating surface for the stove body to be positioned during its
installation.Stonework,uneven bricks,loose tiles etc.,may need further work to
ensure that this can be achieved.
The stove should be installed on a non-combustible surface not less then 150mm
thick(conforming to Building Regulations unless otherwise specified) of
suitable load bearing capacity and heat resistance. Allowances should be made
for the expansion and contraction of any materials which are fitted up to and
near the appliance.
If required,the dimensions of any constructional hearth for all stoves should
project at least 500mm forward of the front of the appliance and 150mm at the
sides. The surface of the hearth should be free of combustible materials. The
superimposed hearth for all installations should project at least 225mm
forward from the front of the appliance and 150mm either side of the edge of
the appliance.
In most buildings with solid concrete or stone floors, the requirement will be
met by the floor itself,but mark the hearth to ensure floor coverings are kept
well away or use different levels to mark the hearth perimeter.
Please be aware that hot air can cause staining above the fire in a similar
fashion to walls above radiators. To help prevent this and cracking we
recommend that any plaster above the fire should be fitted with reinforcing
expanding mesh for at least 220mm above,and the full width of the fire. You
should also use a suitably heat resistant plaster which should be allowed
sufficient time to fully dry before using the stove or cracking is likely to
occur.
4.2 Combustible Materials Please view the product sheet or data plate which
accompanied your stove for specific minimum distances to combustible
measurements. Ideally,adjacent walls should be of suitable non-combustible
construction, preferably brickwork.
In large fireplaces take care that any supporting beam is protected by a 13mm
sheet of heat resistant fire board spaced 12mm off the surface with strips of
non-combustible material. Make sure that there is a gap between an un-
insulated flue system and any combustible material. This gap must be at least
3X the outside diameter of the flue pipe,or 1. 5X the flue diameter to non
combustible surfaces. Please consult the flue manufacturers specification for
insulated flues.
Page 8
Date: 01/07/2021 Version Number: 2021 Issue no.1
4.3 Air For Combustion All stoves require ventilation to burn safely and
correctly. There are a number of requirements that need to be met when
installing a stove, for example,allowing for the permeability of the house
(air permeability is the general seepage of air into the house via air
vents,doors and windows etc. ) There must always be a permanent means of
providing air for combustion into the room in which the stove is installed.
Air starvation will result in poor flue draw and may cause smoke to leak into
the room. For all installations it is recommended that a permanent vent with a
total free area of at least 550mm2 for every kW above 5kW should be connected
directly to the outside air.Installations in properties built after 2008
should have their vent increased by a further 330mm2 for each of the first
5kW. Alternatively, this air can be supplied through an external wall of an
adjacent room,which itself has to be connected to the room the appliance is
installed by a permanent vent of the same size. Note: If the appliance is
fitted with a draught stabiliser (or if one is fitted to the flue pipe or
chimney in the same room as the appliance) then the permanent air entry
openingor openings) should be increased by 300mm2 for each kW of rated output
up to 5kW and an additional 850mm2 for each kW output over 5kW. If there is
more than one appliance in the property then each appliance must be supplied
with adequate combustion air so that all appliances can be lit simultaneously.
The positioning of any air vent must be so that it cannot be liable to
blockage or obstruction. Ideally it should also be positioned where it is
unlikely to cause a cold draught. It should not be positioned in the fireplace
recess. For more detailed guidelines on required ventilation sizes please
refer to the Document J Building Regulations (Combustion Appliances) at the
www.planningportal.gov.uk website.
Page 9
Date: 01/07/2021 Version Number: 2021 Issue no.1
5 Flue And Chimneys
5.1 Requirements The stove must be connected to a suitable and efficient flue
so that products of combustion (fumes) from the stove are expelled to the
outside air.Please remember that chimney draught is dependent on four main
factors:
·Flue gas temperature ·Flue height ·Flue size ·Flue terminal
To ensure a good updraught it is important that the flue gases are kept warm
and that the flue size suits the stove. The termination of the outlet at the
top of the flue also needs to comply with Building Regulations. The minimum
effective height of the flue must be at least 4. 5 meters from the top of the
stove to the top of the flue outlet. When warm the flue draught should be
between 0. 1 to 0. 2mb.
The draw of a chimney / flue can vary in different weather conditions and the
customer should be made aware of this. Failure to correct an over-drawing flue
will invalidate the warranty.
A chimney may comply with regulations but could still be subject to
downdraught and similar problems. A chimney terminating above the ridge level
is generally less likely to suffer such problems. If a new chimney is being
provided it should fully comply with the relevant Building Regulations that
specify the requirements for solid fuel burning installations. Suitable types
of chimney include the following:
·Masonry Chimney: Built with clay or concrete liners, or a chimney block
system meeting Building Regulations. These types of chimneys should be
installed in accordance with the Building Regulations and BS EN15287-1: 2007.
·Factory Made Insulated Chimney: Complying with BS 4543: Part 2 (often called
Class 1 prefabricated metal chimney) . These types of chimneys should be
installed in accordance with Building Regulations and BS EN 15287-1: 2007.
Due to the gradual introduction of European Chimney Standards chimneys will be
specified according to their performance designation as defined in BS EN 1443
that covers the General Requirements for chimneys. The minimum performance
designation required for use with solid fuel burning stoves is T450 N2 S D3.
Ensure that the flue pipe diameter is not less than the diameter of the
appliance outlet.
The flue and chimney installation must be carefully checked by a competent
person before fitting the stove to ensure it is suitable and will work safely.
If the chimney is old (i.e.:built of brick or stone without a liner) or being
opened up for reuse, additional checks and smoke testing as described in
Appendix E of the Approved Document J 2010
Page 10
Date: 01/07/2021 Version Number: 2021 Issue no.1
Edition should also be carried out to ensure the flue and chimney are in good
operating condition.
Check the existing flue is in good condition with suitable access for
collection and removal of debris.
It is also important that suitable flue pipe (recommended at least 600mm in
length)complying with the Building Regulations is used to connect the stove to
the flue in the chimney. Suitable access should be provided into the flue for
regular inspection and sweeping of the flue ways.
The installer should comply with Building Regulations requirements in respect
of providing a Notice Plate giving details on the chimney,flue lining,hearth
and fireplace installation.
Chimneys should be as straight as possible. Horizontal runs should be avoided
except where the rear outlet of the appliance is used, in which case the
horizontal section should not exceed 150mm in length. If necessary a
combination of 45°and 90° bends can be used,as long as the sum of their angles
is not greater than 180° in total. IE: four x 45° bends or two x 45° and a
90°bend.
If the stove appears to be working hard but produces very little output to the
room it is likely that excess draw is present in the chimney,and that heat is
being sucked out of the appliance and up the chimney. If this is the case we
recommend the fitting of a draught stabiliser in preference to a flue damper,
in the interest of safety and efficiency.
6 Installing The Stove
To make the stove easier to manoeuvre (and safer) we recommend you remove the
following parts which can then be refitted when the stove is in its final
position:
Liners, Door (To help prevent the glass from breaking) , Operating Tool, Ash
pan, Throat Plate& Fuel Retainer.
6.1 Removing the door Open the door so that it’s perpendicular to the stove
body and then carefully lift the stove door upwards off its hinges. To replace
the door reverse the instructions above.
6.2 Removing the throat plate and liners The throat plate rests on the rear
liner and ledge within the upper edge of the door aperture. Push up on the mid
part of the throat plate with the palm of one hand.With the other,remove the
upper rear liner and then lower the throat plate forward from the ledge.
Diagonally twist the throat plate to allow removal through the door
aperture.The remaining liners,can now be removed. Again reverse procedure for
refitting.
6.3 Fitting The Flue Spigot Outlet The flue spigot outlet is found packed
inside the appliance. Depending upon the particular installation,the flue
spigot outlet can either be fitted to the top or rear outlet.The fitting of
the spigot is affixed to the stove body using the 3no. M6 Square cup
bolts,washers and nuts supplied. Note, ensure that the rope seal is in place
before fully tightening the fixings. A very thin layer of fire cement can also
be applied to the mating surfaces.
Page 11
Date: 01/07/2021 Version Number: 2021 Issue no.1
6.4 Fitting The Hot Plate (Blanking Plate) The hot plate or sometimes referred
to as a blanking plate, will be supplied inside the stove. Again this can be
fitted to either outlet on the appliance and is dependent upon the
installation requirements.Fitting is simply done using the supplied M6 nuts
and washers (no bolts are required as studs are factory fitted to the hot
plate disc) . Again fire cement can be used in conjunction with the self
adhesive rope seal.
IMPORTANT INFORMATION
When fitting the flue spigot & hot plate, always ensure that the rope seal is
fitted. Failure to do so, could lead to exhaust fume leakage into the property
and potential carbon monoxide poisoning. 6.5 Connecting The Spigot Outlet To
The Flue System The flue pipe must be fitted inside the outlet spigot as shown
in Figure 1. Failure to do so could result in the spillage of condensation
running down the flue. Fire cement should be used to create an airtight seal
between the flue and spigot.
Spigot
Rope Seal Joint
Fig. 1.Flue & Spigot Fitting
6.6 Firebox Liner Panels All models of the Wood ford stove collection,use
firebox liner panels to the side, back and either side of the rotating grate
to the base of the appliance.The stove will be delivered with the liner panels
in situ, however it may be easier to remove these during installation. 6.7
Optional Accessories Further optional extras, such as a direct air connector,
rear heat shield, solid fuel burning kit etc.are available via your retailer
or dealer.
Page 12
Date: 01/07/2021 Version Number: 2021 Issue no.1
6.8 Smoke Control Area (The Clean Air Act 1993 & Smoke Control Areas) If the
stove is to be installed in a designated Smoke Control Area (further
information can be found via https: //www.gov.uk/smoke-control-area-rules)
then the secondary air lever must be fitted with a restrictor plate to prevent
total closure of the secondary air control.The restrictor plate and additional
fixing screw is supplied with your stove NOTE: The minimum air control setting
is governed in manufacture to meet there requirements of Smoke Control
exemption and as a result the appliance will NOT shut down completely when in
the minimum air position setting.
Restrictor Screw Fig. 2. Fitting Smoke Control Restrictor Screw
IMPORTANT INFORMATION
Removal or modification of the restrictor screw is illegal when the appliance
is installed in a smoke exemption area and doing so may result in prosecution
and fine.
Page 13
Date: 01/07/2021 Version Number: 2021 Issue no.1
7 Commissioning the stove
7. 1 Checklist
Before handing over the installation to the customer it is a requirement under
Document Jof the Building Regulations for England and Wales) that the
appliance is lit and the functioning of the chimney system is checked for
satisfactory operation.
Be sure that the chimney is operating and all smoke and fumes are vented to
the atmosphere through the chimney terminal.
Check all joints and seals.
Clean the outside of the cold appliance with a lint free cloth or shoe brush
to prevent any stains becoming burnt on.
Check the flue draught which should read 10-20pa, or 0. 1-0. 2 mbar.
Consult a suitably qualified person who will have the knowledge and equipment
to perform a test.
For a registered Competent Persons scheme (such as those referred to at
www.gov.uk/buildingregulations-competent-person-schemes) ,please complete a
Certificate of Compliance, which is used for checking and reporting the
installation as imposed by the Government. Otherwise please ensure the
installation is approved by your local building control officer.
Ensure a Carbon Monoxide alarm is fitted. This must be between 1m to 3m from
the appliance,and approximately 150mm below the ceiling level.
A fireguard conforming to BS 8423: 2002 should be used in the presence of
children or infirm people.
A notice plate should be provided containing information on the performance
characteristics of the hearth,fireplace,flue or chimney.
Explain the following to the customer: How to operate the riddling mechanism
and air control lever.
The importance of an adequate air supply to the room.
The importance of regularly having the chimney swept/inspected.
That a protective glove should be used when operating the stove.
How changes in the weather can affect the performance of the stove.
Using the correct fuels.
Page 14
Date: 01/07/2021 Version Number: 2021 Issue no.1
8 Warnings-
IMPORTANT INFORMATION
8.1 Important Warnings It is a LEGAL REQUIREMENT that the installation of all
new or replacement,wood or solid fuel heating appliance,obtain building
control approval from your local authority or the installation work must be
carried out through a government approved competent persons scheme. A list of
all competent person schemes can be found:https: //www.gov.uk/guidance
/competent-person-schemecurrent-schemes-and-how-schemes-are-authorised
Any manufacturer’s instructions must not be taken as overriding statutory
requirements.
All Didsbury stoves MUST NOT be connected to a shared flue system.
Please Note: Classification of these appliances is for intermittent use only.
Do not use aerosol sprays or any other flammable materials near the appliance
when in use.
Do not use the appliance as an incinerator.
Use only recommended fuels, STRICTLY NO unsuitable and non recommended fuels
or materials or liquid fuels allowed.
Pure petroleum coke or Bituminous house coal must NOT be burned in this
appliance.The use of these fuels will invalidate the appliance guarantee.
Please ensure that the air inlet vent grills to the dwelling are not
obstructed or liable to be blocked.
Caution must be exercised during operation of the appliance as both internal
and external surfaces will be hot to touch,use the stove mitten provided when
the appliance is in operation.
A fireguard conforming to BS 8423: 2002 should be used in the presence of
children or elderly people.
Always observe the distances to combustible materials as stated on the
appliance data plate and in the technical data section of this manual. Ensure
no soft furnishings or combustible materials are susceptible to heat radiating
from the appliance.
Under NO circumstances should the stove be operated for extended periods with
the main fire door open. This will result in an over firing situation and will
lead to severe damage to the stove and flue system.
Ignoring the warnings could lead to damage/injury to persons and/or property.
Flue & Ducting Ltd will not be responsible for any consequential or incidental
loss or injury however caused.
It is essential that the appliance has adequate air supply for combustion and
ventilation.Apertures
Page 15
Date: 01/07/2021 Version Number: 2021 Issue no.1
provided for this purpose shall not be restricted or covered.
8.2 Health and Safety Please consult health and safety guidelines for advice
on handling heavy and/or large items.
8.3 Smoke control areas (The Clean Air Act 1993 & Smoke Control Areas) Under
the Clean Air Act local authorities may declare the whole or part of the
district of the authority to be a smoke control area. It is an offence to emit
smoke from a chimney of a building,from a furnace or from any fixed boiler if
located in a designated smoke control area. It is also an offence to acquire
an “unauthorised fuel” for use within a smoke control area unless it is used
in an “exempt” appliance (“exempted”from the controls which generally apply in
the smoke control area) .
In England appliances are exempted by publication on a list by the Secretary
of State in accordance with changes made to section 20 and 21 of the Clean Air
Act 1993 by section 15 of the Deregulation Act 2015. In Scotland appliances
are exempted by publication on a list by Scottish Ministers under section 50
of the Regulatory ReformScotland) Act 2014. Similarly in Northern Ireland
appliances are exempted by publication on a list by the Department of
Agriculture, Environment and Rural Affairs under Section 16 of the
Environmental Better Regulation Act (Northern Ireland) 2016.In Wales
appliances are exempted by regulations made by Welsh Ministers.
Your local authority is responsible for implementing the Clean Air Act 1993
including designation and supervision of smoke control areas and you can
contact them for details of Clean Air Act requirements.
Further information on the requirements of the Clean Air Act can be found
here: https: //www.gov.uk/smoke-control-area-rules
The following list of Didsbury models:
Didsbury 5 Wood Burning Stove Didsbury 5 Wide Wood Burning Stove
are currently exempt or have been recommended as suitable for use in smoke
control areas, when burning wood logs and when fitted with a factory set
mechanical stop,to prevent secondary air closure beyond the 5 mm open position
respectively.
Page 16
Date: 01/07/2021 Version Number: 2021 Issue no.1
9 Recommended fuels
9.1 Wood As a natural and renewable fuel, wood is the first choice for
burning, however burning wood requires a little effort and planning. Any type
of wood is suitable (though hardwood is preferable) provided it is well
seasoned and has a moisture content below 20%. This usually implies that the
timber has been suitably stored to allow moisture to evaporate for at least 9
months in the case of soft wood,and at least 24 months in the case of hard
wood. We recommend that for general burning, wood should be split into logs of
no more than 100mm (4inches) diameter. If,when burning wood, you see signs of
sticky tar inside the appliance or chimney,your wood is ‘green’ or too wet and
requires further seasoning. An electronic moisture meter can be obtained in
order to determine the moisture content of your wood fuel.Wet wood must not be
used as this will greatly contribute to the creation of tar and creosote which
may, in extreme cases, run down the chimney in liquid form. This will
seriously damage both the chimney and the appliance and increase the risk of a
chimney fire. 9.2 Solid Fuel Didsbury is a pure wood burner.Other fuel options
are Multi Flue Kit. Flue & Ducting Ltd, recommends the use of approved wood
fuels which have been deemed suitable for use on closed appliances including
multi fuel stoves or boilers.Authorised fuels suitable for Smoke Control
Areas,please seehttps: //smokecontrol.defra.gov.uk/fuels) For additional
advise on fuels, please refer to the Solid Fuel
Associationwww.solidfuel.co.uk) DO NOT BURN Bituminous house coal or petroleum
coke in this appliance. PLEASE NOTE: All test data, outputs and efficiencies
stated in this instruction manual were obtained by burning ‘Maxibrite’ mineral
smokeless fuel. DO NOT BURN Any form of plastics in this appliance.
Page 17
Date: 01/07/2021 Version Number: 2021 Issue no.1
10 Before using your stove
10.1 Pointers Before Use
Didsbury stoves are designed to be operated with the fire door (s) closed at
all times,apart from refueling (when alight) or cleaning (when cold).
Never leave the appliance unattended for an extended length of time with the
door (s) open.
Prior to lighting the stove for the first time,please check with the installer
that: Installation and all building work is complete. (Refer to the
installation guide.) The chimney is sound, has been swept and is free from
obstruction. Building Regulations and any local by-laws have been followed
during installation. All firebox liner panels and throat plate are in place.
The chimney draw has been checked and is within specification (between 0.1mb
to0. 2mb,or 10-
20 pascals) . This ensures your stove will operate predictably and
efficiently. Carbon Monoxide detector is correctly installed in the same room
as the appliance. Suitable provision for combustion and ventilation air,
depending upon building regulations have
been undertaken by the installation fitter. Consideration must be given for
the need for extra ventilation if another heating source needing air
is to be operated simultaneously. If an extraction fan is pro-posed to be
fitted to a connecting area of the house, after the stove has been
installed,professional advice should be sought from a qualified engineer.
Ensure that you have read and understood these instructions before lighting
the fire.
Always wear suitable protective fire gloves when refueling your stove,such as
the hot glove supplied with your stove. Always keep the hot glove away from
naked flames and sparks, when refueling the appliance.
We recommend that you light a small fire for the first few days of use to cure
the paint and allow the castings to relax.
You may hear your stove produce clicking or ticking noises whilst it heats up
or cools down. This is completely normal and is produced by the expansion and
contraction of the steel components in your stove when its temperature
changes.
Page 18
Date: 01/07/2021 Version Number: 2021 Issue no.1
11 Air inlet controls
11.1 Air Inlet Your stove requires air to function,this enters at the bottom
rear of the appliance. Depending upon installation, an optional direct air kit
can be purchased as the connection point for the direct air
feed/ducting,installation requirements.
Rear View Of Stove
Air Inlet To Air Controls
NOTE: D NOT COVER OR PARTIALLY OBSTRUCT THE AIR INLET OPENINGS FOR
THEAPPLIANCE. 11.1.1 Primary air control location The primary air control
regulates the air entering the fire box chamber,supplying air be low the
grate.This control is situated below the fire door on the left hand side,when
facing the front of the stove.
Primary Air Control Location
Page 19
Date: 01/07/2021 Version Number: 2021 Issue no.1
11.1.2 Primary air control
The primary air control regulates the air entering the fire box
chamber,supplying air to the under side of the fuel bed.
The control has an internal rotary plate with slots,housed inside the body of
the appliance and is located below the left hand corner of the fire door
assembly.Sliding the control knob to the right, as far as it will go,achieves
the fully open position,see figure 1. Sliding it to the left will shut down /
reduce the air as shown in figure 2.
Fig. 1. Fully Open Position
Fig. 2. Fully Closed Position
11.1.3 Secondary air control
The secondary air control regulates the air entering the fire box
chamber,supplying an over draught of air to the fuel bed, together with
supplying air in front of the glass viewing panel within the door assembly.
This is known also as the air wash system. This control is situated below the
fire door on the right hand side, when facing the front of the stove.
Secondary Air Control Location
Page 20
Date: 01/07/2021 Version Number: 2021 Issue no.1
The control has an internal rotary plate with slots, housed inside the body of
the appliance and is located below the right hand corner of the fire door
assembly, when looking at the front of the appliance. Sliding the control knob
to the right, as far as it will go, achieves the fully open position,see
figure 3. Sliding it to the left will shut down/ reduce the air as shown in
figure 4.
Fig. 3. Fully Open Position
Fig. 4. Closed/Reduced Position
NOTE: If your stove installation is within a smoke control area, it will be
fitted with a restrictor plate acting as a mechanical stop for the secondary
air control. This will not fully close,thus allowing a bleed of air to the
fire box to reduce smoke emissions.
11.1.4 Tertiary Air
All models have tertiary air supply that can be seen working during certain
conditions during the burning period. The outlet for the tertiary air, is at
the rear of the fire box chamber,just below the throat plate through a series
of small holes within the rear liner brick (See page 6).
Tertiary air is employed, to provide additional air to the upper areas of the
fire box to promote additional burning of the unburnt combustion gases and
thus ensuring a cleaner burn emission.
There is no user adjustment required for the tertiary air, as the required air
supply is factory set during the production process.
Page 21
Date: 01/07/2021 Version Number: 2021 Issue no.1
12 Lighting your stove
12.1.1 Smoke control areas
Please check whether your dwelling is located in a smoke control area before
installation or use. Please check with your local authority or https:
//www.gov.uk/smoke-control-area-rules.
12.1.2 Fuel overloading
The maximum amount of fuel specified in this manual should not be
exceeded,overloading can cause excess smoke. Please see technical data section
in this manual.
12.1.3 Operation with door left open
Operation with the door open can cause excess smoke. The appliance MUST NOT be
operated with the appliance door left open except as directed in the
instructions.
12.1.4 Dampers / Air controls left open
Operation with the air controls or appliance dampers open can cause excess
smoke. The appliance must not be operated with the air controls, appliance
damper or door (s) left open except as directed in these instructions.
12.2 Burning wood
When wood is burnt ,it is in fact the volatile gases released from the wood,
that burn and this requires a good supply of air coming from above the
fuel.For this reason we will use all the air inlets while igniting the stove,
but will then reduce this to air coming from the air wash system and over
draught. As much as 40% of the heat from burning wood is obtained from
secondary combustion and this can be severely hampered by air entering the
fire box from below the fuel.
- Set the fire,by placing several layers of dry kindling wood into a criss- cross grid pattern on top of the grate bars. The use of two or three fire lighters may assist in lighting the kindling.
- Fully open the primary and secondary air controls and light the fire lighters and or kindling wood.
- After the kindling has caught light,you should almost close the fire door
leaving it ajar by about 10mm. This will aid flue draw during the initial
lighting of the fire.
4)The flue temperature and draw should be established after five minutes and the kindling reduced to form an ember bed. Carefully load the stove with well seasoned wood and fully close the fire door.
5)After ten minutes,fully close the primary air control and regulate the secondary air control to control the burn rate and maintain clear glass, typically by reducing to approximately half open.
Page 22
Date: 01/07/2021 Version Number: 2021 Issue no.1
12.3 Burning solid fuels Solid fuel burns best with its air supply for
combustion coming from underneath the fuel.To achieve this, the burn will be
controlled by the primary air control. A reduced setting may also be required
on the secondary air control,to maintain clear glass on the door assembly.
Riddling the stove occasionally will also help to ensure that burnt fuel does
not prevent the supply of air from reaching the fuel bed. The procedure for
lighting/burning solid fuel,is as follows: 1) Set the air wash (secondary) air
control to about one quarter open and the primary air control
fully open. 2) Lay the fire by using several layers of dry kindling wood into
a criss-cross grid pattern on top of
the grate bars. The use of two or three fire lighters may assist in lighting
the kindling. 3) After the kindling has caught light, you should almost close
the fire door leaving it ajar by about
10mm. This will aid the flue draw during the initial lighting of the
appliance. 4) Once the flue draw has been established, after about five
minutes,carefully load the stove with
solid fuel, it is suggested that the initial loading is best done using fire
tongs and placing the fuel, rather than shovelling the fuel. 5) When the fire
is well alight regulate the burning rate by controlling the primary air
control. 6) The secondary air control (air wash) should be closed enough to
enable a sufficient supply of air to the glass to keep the door glass clean.
7) Whilst burning solid fuel it can be beneficial to occasionally riddle the
grate bars so any burnt fuel will fall between the grate bars into the ash
pan. Please see ‘Section13-Further Information’ on the procedure for riddling.
Page 23
Date: 01/07/2021 Version Number: 2021 Issue no.1
12.4 Warning-Fume/Smoke emissions Properly installed,with a suitable flue or
chimney,operated and maintained correctly,this appliance will not emit fumes
into the dwelling. Occasional fumes when de-ashing and refueling may occur.
However,persistent fume emission is potentially dangerous and must be
investigated by an approved/registered installer.
STOP USING THE APPLIANCE IF YOU SMELL FUMES OR SEE SMOKE ESCAPING.
If fume emission does persist, the following immediate actions should be
taken:
Open doors and windows to ventilate room.
Let the fire die or extinguish and safely dispose of fuel from the appliance.
Check for flue or chimney blockage,and clean if required.
Seek expert advice from your approved installer.
Do not attempt to re-light the fire until the cause of the fume emission has
been identified and corrected.
12.5 Refueling on to a low fire bed
If there is insufficient burning material in the fire bed to light a new fuel
charge,excessive smoke emission can occur. Refueling must be carried out onto
a sufficient quantity of glowing embers and ash that the new fuel charge will
ignite in a reasonable period. If there are too few embers in the fire bed,
add suitable kindling for ignition to prevent excessive smoke.
Important notes on usage, to meet the requirements of Smoke Control exemption-
Always recharge onto hot embers. After re-charging, fully open both the
primary and secondary air controls for the
following times, in order to establish good combustion-
Didsbury 5 Wood Burning Stove Didsbury 5 Wide Wood Burning Stove
Do not leave the appliance unattended until flames are well established.
Periodic burning out of the fuel bed at high output to combust any remaining
charcoal.
Page 24
Date: 01/07/2021 Version Number: 2021 Issue no.1
12.6 Smoke Control Area (The Clean Air Act 1993 & Smoke Control Areas) If the
stove is to be installed in a designated Smoke Control Area (further
information can be found via https: //www.gov.uk/smoke-control-area-rules)
then the installer will have fitted the restrictor plate for the secondary air
lever to prevent total closure of this air control.
Restrictor Screw (Smoke Exemption) Fig. 5. Fitted Smoke Exemption Restrictor
Screw NOTE: The minimum air control setting is governed in manufacture to meet
the requirements of Smoke Control exemption and as a result the appliance will
NOT shut down completely when in the minimum air position setting. Removal or
modification of the fitted air control plate (See Fig. 5) is illegal when the
appliance is installed in a smoke exemption area and doing so may result in
prosecution and fine. 12.7 Typical burn for nominal out put To perform the
most efficient burn at the nominal rated output please consult the
specification table at the rear of this manual. Please note, many factors can
affect the nominal output,so the stated weights of fuel (Seasoned hard wood,
Beech and Mineral solid fuel, ‘Maxibrite’) are a guide,which is a
representation to laboratory test burn conditions.
Page 25
Date: 01/07/2021 Version Number: 2021 Issue no.1
13 Further information for all stove owners
13.1 Reduced burning (Slow Combustion)
When wood is burnt slowly in a closed appliance (eg: air controls at the
minimum setting) ,it produces moisture and tar, which will create condensation
and deposits in the chimney. This effect can be minimised by burning hard for
a short period,fifteen to twenty minutes twice a day. To avoid chimney
problems your appliance should not be burnt at a reduced burn rate without a
period of fast burning. Fast burning is when the stove is burnt with a ‘lively
flame’ and a higher temperature. We strongly advise against stoking the fire
with wood and reducing the air inlets before leaving the stove to extinguish
(perhaps when retiring to bed) as this can lead to a cooling of the stove and
flue also resulting in incomplete combustion,sooty deposits and high levels of
pollutant gases released into the environment.
13.2 Over firing
DO NOT over fire your appliance. Firing the stove at maximum for prolonged
periods may result in over-firing. If the chimney connector or casing glows
red the appliance is being over-fired and this may result in a chimney fire.
Other signs include warping and a red-oxide colouring will demonstrate the
over- heating of internal parts; body paint which has turned dusty white is
also indicative of such use.
13.3 Chimney fires
Used in the correct manner,with the correct fuel and regular maintenance a
chimney fire should never occur, however in the even of a chimney fire,the
following procedure should be actioned without delay:
Call the fire service-DIAL 999 Immediately close all of the air inlet supplies
on the appliance,to reduce the air supply to the
stove. Move items of furniture and combustibles away from the surrounding area
of the stove, to
reduce the risk of fire and allow access for the fire service. Ensure access
to the loft space is available. Evacuate the property.
13.4 Periods of non-use (summer months)
Please ensure that your stove is left clean and moving components are well
lubricated with a water repelling corrosion inhibitor for the summer months
(during periods of prolonged non-use) . If possible store the throat plate
outside of the stove. Check all moveable components at regular intervals, to
ensure they are moving freely. Allow air movement through the stove by opening
the primary air inlet control (s) to about halfway,open or leave the door
ajar. This will allow a free flow of air through the appliance thus preventing
moisture and condensation forming inside the stove and chimney. This
preventative maintenance will ensure your stove stays in the best condition
for the coming winter months. 13.5 Multi Flue Kit Optional Accessories
Page 26
Date: 01/07/2021 Version Number: 2021 Issue no.1
13.5.1 Riddling the firebox
To riddle the grate,the main fire door will need to be open, carefully open the fire door,using the
stove glove supplied. Multi Flue Kit Optional Accessories mounted riddle lever,using the
glove,move the lever left to right,repeatedly,until the ember/ash bed is has been reduced.Note:if this
procedure is performed vigorously then ash maybe discharged from the firebox, care should be taken
to avoid this from happening.
WARNING: ALWAYS USE THE
GLOVE SUPPLIED.
Extreme care must be taken if the appliance is under fire, risk of injury or burn.
Riddle Lever
Fig. 6. Riddle Lever
13.5.2 Ash removal
The ash pan should be emptied when the level of ash reaches the top of the ash
pan. On no account should the ash be allowed to build up to touch the
underside of the grate,as this will greatly reduce the life span of the grate.
To remove the ash pan ALWAYS USE the supplied glove & operating tool-
Open the door of the stove, pausing briefly when ajar so as to allow the fire
to adjust to the increased air supply.
Insert the fork end of the operating tool into the ash pan (see Fig. 7.).
Carefully withdraw the ash pan from the ash pit chamber. Empty the ash into a
suitable metal container. Replace the ash pan into the stove,reversing
the above procedure and close the fire door.
WARNING: Ash can be very hot!!. Care must be taken not to burn hands or house-
hold objects with falling embers-ALWAYS USE THE GLOVE SUPPLIED.
Empty only into a metal container. Even if the ash appears cold,red hot embers
may be concealed and could easily start a fire or cause an injury.
Page 27
Date: 01/07/2021 Version Number: 2021 Issue no.1
Ash pan
Operating Tool
Fig. 7.Ash Pan
13.6 Replacement parts Genuine replacement spare parts can be obtained from
your Flue & Ducting retailer/dealer. You can find a complete list of spares
and consumables such as liners, replacement grate parts and throat plates as
well as items to enhance its visual appearance and efficiency such as stove
paint and rope kits. It is worth noting that the fitting of non-official parts
to your stove will invalidate its guarantee. 13.7 Classification All Didsbury
stoves are classed as intermittent operation. Thereby meaning,to give nominal
rated output,you will have to refuel a minimum of 45min for wood or 1hr for
solid fuel, as stated in EN
13240+Amd2-2004.
13.8 Adverse weather conditions If due to adverse weather conditions your
stove does not operate correctly and causes the stove to emit smoke, do not
treat it as a nuisance, this smoke will indicate that carbon monoxide is being
emitted into the room. Extinguish the stove by reducing the firing rate,open
windows and allow the stoves’ fuel to burn out before closing the windows. The
probable cause is insufficient draw,check flue ways and have the chimney
tested for flue pressure.
Page 28
Date: 01/07/2021 Version Number: 2021 Issue no.1
13.9 Door glass The door glass should remain clear during normal burning.
However under certain conditions,such as burning at a low or slow rate, using
damp wood or overnight burning,the glass may become somewhat blackened. To
remedy this,operate the appliance at a fast rate. Alternatively when the stove
is cold, open the door and clean the inside face of the glass with a damp
cloth or with glass cleaner. 13.10 Fire door handle
Care must be taken when opening and closing the fire door as any surrounding
surfaces will be VERY HOT. ALLWAYS USE THE HOT GLOVES WHEN USING THE FIRE
DOOR/RIDDLE HANDLE-RISK OF PERSONAL INJURY MAY OCCUR. CAUTION MUST BE GIVEN
WHEN RE-FUELLING THE APPLIANCE, KEEP THE GLOVE AWAY FROM NAKED FLAMES &
SPARKS.
Page 29
Date: 01/07/2021 Version Number: 2021 Issue no.1
14 Care for your stove
The need for regular maintenance on your stove will ensure, safe and efficient
use of your appliance. The following item listing should be checked and
inspected by a competent person or engineer on a regular basis.
PLEASE ENSURE THAT THE STOVE IS UNLIT AND COLD, BEFORE ATTEMPTING TO INSPECT
THE BELOW ITEMS-
14.1 Adjusting the door hinges
Once the appliance has been under fire for a period of time the fire door may
appear to have moved out of alignment with relation to the door aperture or
catch. This is quite normal and due to the settling of the casting. It may be
possible to tighten the retaining screws on the hinge assembly.
If the fire door needs to be raised,please follow the instructions below: Open
the fire door so that it is at right angles to the front of the stove.Apply a
lifting pressure to remove the door from the hinge assemblies, it may be
necessary to move the door assembly from left to right whilst applying an
upward force,to release the door from the hinges.Drop one washer (M5) over the
top hinge pin. Align the door assembly onto the hinge and apply a downward
pressure to refit the door onto the hinge assemblies. Check & repeat again if
necessary.
14.2 Liners / firebricks
The stoves liners (also known as firebricks) may become cracked after long
periods of heavy use or after being knocked by the loading of fuel or a poorly
aimed fire poker.If the liners are still staying in situ and are able to
support themselves correctly there is no need to replace them. Cracked liners
will not in themselves affect the performance of the stove.
14.3 Throat plate
The throat plate can be removed from the stove,by lifting the throat plate up
and removing the rear liner,this will then allow the rear of the throat plate
to swing down.Disengage the front lip of the throat plate from the upper
location bracket. Rotate the throat plate,diagonally across the
firebox,manipulating the plate through the door opening. Any accumulated
deposits should be cleaned off, this is best done with a brush.Whilst doing
so, inspect the throat plate for any damage.Replacement throat plates can be
sourced from your local dealer or via the internet at www.flue-ducting.co.uk
Page 30
Date: 01/07/2021 Version Number: 2021 Issue no.1
14.4 Fire door seal
The rope seal around the edges of the main fire door should also be checked.
Look for signs of fraying,peeling away or the ends not meeting. If the rope is
unable to create a good seal with the stove body it should be replaced. A poor
seal will decrease your ability to control the burn rate and its efficiency
whilst leading to an increase in heat lost through the flue.
14.5 Cracked glass
It is not recommended to operate the stove with cracked glass;this can lead to
over firing due to air leaking into the firebox and it may fail completely
leading to personal injury or a fire. You should discontinue use of your stove
until it has been repaired. You can source replacement glass kits from www
.flue-ducting.co.uk or your local retailer.
14.6 Chimney/Flue Sweeping
Sweeping should be carried out with an appropriate sized bristle brush and
rods to suit chimney size and type. As with all appliances regular sweeping of
the flue/chimney is essential to avoid dangers of blockage and the escape of
poisonous fumes. Access for cleaning should also be incorporated in the
chimney (eg:soot door or access through the register plate etc) . It is
important that the flue connections,flue pipe and chimney be cleaned prior to
lighting after a prolonged period of non use.
15 Further resources/information
15.1 Information
Competent Person Schemes https: //www.gov.uk/guidance/competent-person-scheme-
current-schemes-and-how-schemesare-authorised
Document J Building Regulations (Combustion Appliances)
www.planningportal.gov.uk/
The National Association of Chimney Sweeps (NACS) www.nacs.org.uk/
Smoke Control Areas-The Rules www.gov.uk/smoke-control-area-rules
15.2 Specification
All Didsbury stoves are manufactured and independently tested to EN standard
13240and are CE marked. Within the above EN standard,material specifications
and criteria are defined.
Page 31
Date: 01/07/2021 Version Number: 2021 Issue no.1
16 Guarantee
16.1 Guarantee
If any part of the main body of the stove fails due to a manufacturing or
material defect during the guarantee period that applies in respect of the
relevant stove (as set out below) , Flue&Ducting Ltd will,at its sole
discretion,repair or replace your stove,for no charge.
For the purposes of this guarantee, a material or manufacturing defect
includes the splitting or cracking of the main body (defined as the steel
outer casing and items fixed immovably to the casing) .
Damage caused by over-firing or over-heating is not covered. Warping and a
red-oxide colouring will demonstrate the over- heating of internal parts; body
paint which has turned dusty white is also indicative of such use.
The following guarantee periods shall apply in respect of the following:
Didsbury stoves come with a LIFETIME warranty to the main body of the stove.
The external paint finish carries a one-year guarantee only.
This guarantee is subject to the Terms and Conditions set out below.
16.2 Terms and Conditions
The following terms and conditions must be satisfied in order for your stove
to be covered by the guarantee set out above:
1. Your stove must have been purchased from an officially approved dealer.
2. You must be the original purchaser of the stove in order to make a claim.
This guarantee is not valid in relation to any claims made by someone who did
not originally purchase the stove from Flue & Ducting Ltd or an approved
retailer/dealer.
3. Any claim under this guarantee must be made through the approved dealer
where the stove was purchased and accompanied by proof of purchase (e.g. a
valid receipt).Stoves not purchased from an approved retailer/dealer will not
be covered by this guarantee.
4. Your stove must be installed in the UK for this guarantee to be valid.
Stoves installed outside of the UK will not be covered by this guarantee.
5. Your stove must have been installed by a suitably qualified person and in
accordance with the manufacturer’s installation instructions. Stoves not
installed by a suitably qualified person or not installed in accordance with
the manufacturer’s installation instructions will not be covered by this
guarantee.
Page 32
Date: 01/07/2021 Version Number: 2021 Issue no.1
6. Any claims under this guarantee shall not be valid where the installation
of the stove does not conform to all required building regulations and other
legislation in force at the time of purchase and where flue draw readings have
not been made to confirm a suitability of the flue. The manufacturer’s
decision as to whether this condition has been satisfied shall be final.
7. The guarantee does not cover damage caused to the stove through careless
handling or misuse or neglect of the appliance (misuse and neglect being not
following the manufacturer’s instructions and user guides in relation to the
stoves, including the use of non-recommended fuels) .
8. The following consumable service items are not covered by this guarantee:
· Firebox linings · Grate · Fuel retainer · Throat plate · Door/Door glass ·
Seals
9. The guarantee does not cover damage caused by storing or using the stove
in a damp environment,defects or faults caused by local conditions such as
draught problems and chimney defects or corrosion caused by condensation,damp
or water ingress into the flue,chimney or the surrounding of the stove.
10. The guarantee is only valid if the stove is serviced and checked annually
by a suitably qualified heating engineer,with documentation to be retained and
produced in the event of a claim being made.
11. The guarantee is only valid where any spare parts used are supplied by
Flue &Ducting or an approved retailer/dealer. The use of spares other than
those supplied by Flue & Ducting Limited shall invalidate the guarantee. Parts
can be purchased through an approved dealer or directly from Flue &
Ducting,online at www.flue-ducting.co.uk
12. The guarantee is not valid where any repairs or modifications have been
made to the stove which have been carried out by anyone other than Flue &
Ducting Ltd or its authorised representatives or approved dealers.
13. All guarantee periods commence on the date of purchase and are non-
transferable and solely for the benefit of the original purchaser of the
stove.
16.3 General
Our guarantee is offered as an addition to your statutory rights and will not
effect your statutory rights. You can obtain information about your legal
rights from trading standards office’s or a citizens’ advice bureau.This
guarantee is applicable in the UK only and operates exclusively in accordance
with the laws of England and Wales.
If you believe your appliance is not working correctly or it has broken down,
in the first instance please contact your local retailer or installer for
assistance.
Page 33
Date: 01/07/2021 Version Number: 2021 Issue no.1
TECHNICAL SPECIFICATION
Parameter
Height
Width
Depth
Flue outlet
Total efficiency
%
Nominal heat output
kw
Mean CO2 emission
%
Mean CO emission
%
Mean CO emission(at 13%O2) %
Mean flue gas temperature
Flue gas mass flow
g/s
Mean CnHm emission
Nm g/m3
Mean NOx emission
Nm g/m3
Particulates(at 13 % 02) Nm g/m3
Distance to Combustibles-Rear (mm)
Distance to Combustibles-Side (mm)
Didsbury 5 585 mm 457 mm 350 mm 127 mm 84.5 5.0 11.6 0.1 0.07 233 3.6 62 90 9 450 500
Didsbury 5 wide 600 mm 522 mm 350 mm 127 mm 81.7 5.0 10.3 0.12 0.09 246 4.1 69 100 10 300 250
Page 34
Date: 01/07/2021 Version Number: 2021 Issue no.1
Page 35
Date: 01/07/2021 Version Number: 2021 Issue no.1
Point 1 2 3 4 5 6 7
8
Declaration of performance according to Regulation (EU) 305/2011
Ref No: Didsbury 5 -2021-01
Product Type
Flue & Ducting room heater burning solid fuel without supply of hot water in accordance with EN 13240:2001
Product model designation
Didsbury 5 , Serial No. –
Intended use
Room heater burning solid fuel without supply of hot water
Manufactured by
Manufacturer’s authorised representative
System of assessment and verification of constancy of performance
Flue & Ducting, Unit D6 Yew Street Stockport Trading Estate SK4 2JZ, Tel:+44
0161 480 2994, Email:sales@flue-ducting.co.uk
System 3
Notified laboratory name and address
The notified laboratory Kiwa Gastec, Lab Notified body No 0558 performed the
determination of the product type specification on the basis of
type testing under system 3 and issued the test report Ref: Didsbury 5 61556-1
Kiwa House, Malvern View Business Park, Stella Way, Bishops Cleeve
Cheltenham , GL52 7DQ , UK,T: +44(0)1242 662110 M: +44(0)7855 064781
Declared performance:-
Harmonized Technical specification:
Essential characteristics Fire Safety:-
Reaction to fire
Clearance distances to combustible materials
Risk of burning fuel falling out Emission of combustion products
Mean CnHm emission Mean NOx emission
Particulates Surface temperatures
Electrical safety Cleanability
Maximum operating pressure Flue gas temperature at nominal heat output
Mechanical resistance to carry a chimney Nominal output
Room heating output Water heating output
Gross efficiency Net Efficiency
EN 13240:2001
Performance Wood
A1
Rear = 450mm Sides = 500mm Ceiling = NPD
PASS CO = 0.07% 62 Nm g/m3 90 Nm g/m3 9 Nm g/m3
PASS N/A PASS N/A 233 °C NPD 5.0kW 5.0kW
84.5%
9
The performance of the product identified in points 1 and 2 is in conformity with the declared performance given
in point 8.
Signed for and on behalf of the manufacturer by:
__ (Name)
_23/11/2021____ (Date of issue)
__ (Signature)
Page 36
Date: 01/07/2021 Version Number: 2021 Issue no.1
Point 1 2 3 4
5
6
7
Declaration of performance according to Regulation (EU) 305/2011
Ref No: Didsbury 5 wide-2021-01
Product Type
Flue & Ducting room heater burning solid fuel without supply of hot water in accordance with EN 13240:2001
Product model designation Intended use
Manufactured by
Didsbury 5 wide, Serial No. –
Room heater burning solid fuel without supply of hot water
Flue & Ducting, Unit D6 Yew Street Stockport Trading Estate SK4 2JZ, Tel:+44
0161 480 2994, Email:sales@flue-ducting.co.uk
Manufacturer’s authorised representative
System of assessment and verification of constancy of
performance
System 3
Notified laboratory name and address
The notified laboratory Kiwa Gastec, Lab Notified body No 0558 performed the
determination of the product type specification on the basis of type testing
under system 3 and issued the test report Ref: Didsbury 5 wide – 61556-2
Kiwa House, Malvern View Business Park, Stella Way, Bishops Cleeve
Cheltenham , GL52 7DQ , UK,T: +44(0)1242 662110 M: +44(0)7855 064781
8
Declared performance:-
Harmonized Technical specification:
Essential characteristics Fire Safety:-
Reaction to fire
Clearance distances to combustible materials
Risk of burning fuel falling out Emission of combustion products
Mean CnHm emission Mean NOx emission
Particulates Surface temperatures
Electrical safety Cleanability
Maximum operating pressure Flue gas temperature at nominal heat output
Mechanical resistance to carry a chimney Nominal output
Room heating output Water heating output
Gross efficiency Net Efficiency
EN 13240:2001
Performance Wood
A1
Rear = 300mm Sides =250mm Ceiling = NPD
PASS CO = 0.09% 69 Nm g/m3 100 Nm g/m3 10 Nm g/m3
PASS N/A PASS N/A 246 °C NPD 5.0kW 5.0kW
81.7%
9
The performance of the product identified in points 1 and 2 is in conformity with the declared performance given
in point 8.
Signed for and on behalf of the manufacturer by:
__ (Name)
__23/11/2021 __
(Date of issue)
(Signature)
Page 37
Date: 01/07/2021 Version Number: 2021 Issue no.1
flue&ducting
Total Chimney Solutions
UK MADE
All Didsbury Stoves are manufactured in the UK Flue & Ducting Ltd
Unit D6 Yew Street Stockport Trading Estate SK4 2JZ United Kingdom
www.flue-ducting.co.uk T: +44 (0)161 480 2994 Email:sales@flue-ducting.co.uk
References
- Welcome to Ducting.co.uk
- Fuels - Defra, UK
- Flue & Ducting
- Smoke control areas: the rules - GOV.UK
- Home - The National Association of Chimney Sweeps (NACS)
- Planning permission: When you need it - GOV.UK
- Planning permission: When you need it - GOV.UK
- Solid Fuel Association - Advice for consumers & professionals
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>