Safety Instructions

All instructions must be read and observed in order for the measuring tool to function safely. The safeguards integrated into the measuring tool may be compromised if the measuring tool is not used in accordance with these instructions. Never make warning signs on the measuring tool unrecognisable.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
AND INCLUDE THEM WITH THE MEASURING TOOL WHEN TRANSFERRING IT TO A THIRD PARTY.

  •  Warning! If operating or adjustment devices other than those specified here are used or other procedures are carried out, this can lead to dangerous exposure to radiation.

  • The measuring tool is delivered with a laser warning sign (marked in the illustration of the measuring tool on the graphics page).

  • If the text of the laser warning label is not in your national language, stick the provided warning label in your national language over it before operating for the first time.
    Do not direct the laser beam at persons or animals and do not stare into the direct or reflected laser beam yourself. You could blind somebody, cause accidents or damage your eyes.

  • If laser radiation hits your eye, you must close your eyes and immediately turn your head away from the beam.

  • Do not make any modifications to the laser equipment.

  • Have the measuring tool serviced only by a qualified specialist using only original replacement parts. This will ensure that the safety of the measuring tool is maintained.

  • Do not let children use the laser measuring tool unsupervised.
    They could unintentionally blind themselves or other persons.

  • Do not use the measuring tool in explosive atmospheres which contain flammable liquids, gases or dust. Sparks may be produced inside the measuring tool, which can ignite dust or fumes.

Product Description and Specifications

Intended Use
The measuring tool is intended for measuring distances, lengths, heights and clearances, and for calculating areas.
The measuring tool is suitable for indoor use.
Product Features
The numbering of the product features refers to the representation of the measuring tool in the images.

  1. Display
  2. Measuring button
  3. Function button
  4. Symbol for reference level of measurement (rear edge)
  5. Carrying strap mount
  6. Battery compartment cover
  7. Locking mechanism of the battery compartment cover
  8. Serial number
  9. Laser warning label
  10. Reception lens
  11. Laser beam output
  12. Laser target plate A)
  13. Laser viewing glasses A)
    A) Accessories shown or described are not included with the product as standard.

Display elements
(a) Status bar
(b) Measuring function display
(c) Laser switched on
(d) Battery indicator
(e) Measured value lines
(f) Current measured value/result line
(g) Measuring functions menu
(h) Units of measurement menu

Technical data

Digital laser measure GLM 30-23
Article number 3 601 K72 X..
Measuring range A) 0.15 − 30 m
Digital laser measure GLM 30-23
Measuring range (unfavourable conditions) B) 0.15−10 m
Measuring accuracyA) ±1.5 mm
Measuring accuracy (unfavourable conditions) B) ±3.0 mm
Smallest display unit 1.0 mm
Measuring time 0.5 s − 4.2 s
General
Operating temperature –10 °C to +45 °C
Storage temperature –20 °C to +70 °C
Relative air humidity max. 90 %
Max. altitude 2000 m
Pollution degree according to IEC 61010-1 C) 2
Laser class 2
Laser type 635 nm, < 1 mW
Divergence of the laser beam < 1.5 mrad (full angle)
Weight according to EPTA-Procedure 01:2014 0.09 kg
Dimensions (L x W x H) 100 × 43 × 24 mm
Unit of measurement setting m / cm / fractional ft-inch / fractional ft /

Taiwanese ft
Batteries| 2 × 1.5 V LR03 (AAA)
Digital laser measure| GLM 30-23
Rechargeable batteries| 2 × 1.2 V HR03 (AAA)

A) When measuring from the back edge of the measuring tool, this applies for high reflectivity of the target (e.g. a wall painted white), weak background lighting and a 20 °C operating temperature; a distance-dependent deviation of ±0.05 mm/m must additionally be factored in.
B) When measuring from the back edge of the measuring tool, this applies for high reflectivity of the target (e.g. a wall painted white), strong background lighting, 20 °C operating temperature and high elevation. In addition, a deviation of ±0.15 mm/m must be taken into account, depending on the distance.
C) Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.
The serial number
(8) on the type plate is used to clearly identify your  measuring tool.

Inserting/Changing the Battery

Using alkali-manganese or nickel metal hydride rechargeable batteries (especially at low operating temperatures) is recommended for operation of the measuring tool.
With 1.2 V rechargeable batteries, more measurements may be possible than with 1.5 V batteries, depending on the capacity.
Open the battery compartment cover.
Insert the batteries/rechargeable batteries.
Always replace all the batteries/rechargeable batteries at the same time. Only use batteries/rechargeable batteries from the same manufacturer and which have the same capacity.
When inserting the batteries, ensure that the polarity is correct according to the illustration on the inside of the battery compartment.
When the empty battery symbol first appears on the display and flashes, only a limited number of measurements is still possible. Replace the batteries or reusable batteries.
Take the batteries out of the measuring tool when you are not using it for a prolonged period of time. The batteries can corrode and self-discharge during prolonged storage.

Operation

Starting Operation

  • Never leave the measuring tool unattended when switched on, and ensure the measuring tool is switched off after use. Others may be dazzled by the laser beam.
  • Protect the measuring tool from moisture and direct sunlight.
  • Do not expose the measuring tool to any extreme temperatures or variations in temperature. For example, do not leave it in a car for extended periods of time. In case of large variations in temperature, allow the measuring tool to adjust to the ambient temperature before putting it into operation. The precision of the measuring tool may be compromised if exposed to extreme temperatures or variations in temperature.
  • Avoid substantial knocks to the measuring tool and avoid dropping it. After strong external influences on the measuring tool, you should always carry out an accuracy check (see “Accuracy Check”, page 16) before further work.

Switching On and Off
Press the button to switch on the measuring tool.
Press and hold the button to switch off the measuring tool.
If no button on the measuring tool is pressed for approx. 5 min, the measuring tool will switch off automatically to preserve the non-rechargeable batteries.

Measuring Process
When switching on for the first time, the measuring tool will be in the length measurement function. When switching on every subsequent time, the measuring tool will be in the measuring function that was last used.
The rear edge of the measuring tool is always the reference level for the measurement.
Apply the measuring tool to the point at which you want to start the measurement (e.g. wall).
Press the button to switch on the laser beam.
Target the target surface with the laser beam.
Briefly press the button again to start the measurement.
The duration of the measurement depends on the distance, the lighting conditions and the reflective properties of the target surface. Upon completion of the measurement, the laser beam will automatically switch off.
The measuring tool must not be moved during a measurement. Therefore, place the measuring tool, as far as this is possible, against or on a firm stop or supporting surface.=
The reception lens (10) and the laser beam output (11) must not be covered during the measuring process.

Influences on the Measuring Range
The measuring range depends on the lighting conditions and the reflective properties of the target surface.
For better visibility of the laser beam in bright extraneous light, use the laser viewing glasses (13) (accessory) and the laser target plate (12) (accessory), or shade the target surface.
Influences on the Measurement Result
Due to physical effects, incorrect measurements are possible when measuring on various surfaces. These include:
– Transparent surfaces (e.g. glass, water)
– Reflective surfaces (e.g. polished metal, glass)
– Porous surfaces (e.g. insulation materials)
– Structured surfaces (e.g. roughcast, natural stone)
If necessary, use the laser target plate (12) (accessory) on these surfaces.
Incorrect measurements are also possible on slanted target surfaces.
Likewise, layers of air with different temperatures or indirectly received reflections can influence the measured value.
Changing the Unit of Measurement m/ft
The default unit of measurement is “m” (metres).BOSCH GLM 30-23 Professional
Laser Measure - fig 4Switch on the measuring tool .
Press and hold the button until the menu for selecting the unit of measurement is displayed.
Press the button to change the unit of measurement.
To confirm the selection, press the button.
The selected setting remains saved after you switch off the measuring tool.

Measuring functions

Selecting/Changing Measuring FunctionBOSCH GLM 30-23 Professional Laser
Measure - fig 5You will find the following functions in the Functions menu:
– Length measurement
– Continuous measurement
– Area measurement
Press the button to open the Functions menu.
Select the required measuring function with the button.
To confirm the selection, press the button.
Length Measurement
Press the button to open the Functions menu.
Select the length measurement and confirm the selection with the button.
Briefly press the button to switch on the laser.
Press the button to start the measurement.
The measured value is displayed in the result line (f) at the bottom of the display.
Repeat the above-mentioned steps for each subsequent measurement. If several length measurements are taken in a row, the results of the last measurements are displayed in the measured value lines (e). The last measured value is at the bottom of the display, the penultimate measured value is above it, and so on.
Continuous Measurement
During continuous measurement, the measured value is continually updated. You can, for example, move a required distance away from a wall while reading off the current distance at all times.
Press the button to open the Functions menu.
Select continuous measurement  and confirm the selection with the button.
The laser is permanently switched on.
Move the measuring tool until the required distance is shown on the display.
You can interrupt the continuous measurement by briefly pressing the button.
Press the button again to continue the continuous measurement. The current measured value is displayed in large figures for better readability.
Continuous measurement switches off automatically after 4 min.
Area Measurement
Press the button to open the Functions menu.
Select area measurement and confirm the selection with the button.
Briefly press the button to switch on the laser.
Press the button to start the first measurement, e.g. the length of a room.
Press the button to start the second measurement, e.g. the width of a room. After the second measurement has been completed, the area will be automatically calculated and displayed. The result is displayed in the result line (f). The individual measured values are in the measured value lines (e).

Accuracy Check
Regularly check the accuracy of the measuring tool.
Accuracy Check of the Distance Measurement
For the accuracy check, the measurement should be taken under favourable conditions, i.e. the measuring section should be indoors and the target surface for the measurement should  be smooth and reflect well (e.g. a white- paintedwall).
Select a measuring section of approx. 1 to 10 m long, the length of which you know exactly (e.g. room width, doorway).
Measure the section 10 times in succession.
The deviation of individual measurements from the exact known value may be maximum ±2 mm throughout the entire measuring section under favourable conditions. Log the measurements, so that you can compare their accuracy at a later point of time.
Error Message
If a measurement cannot be performed correctly, the error message Error will appear in the display.
Try to perform the measuring process again.
If the error message appears again, switch the measuring
tool off and back on, and start the measurement again.
The measuring tool monitors correct operation in every measurement. If a defect is detected, the display will indicate only the symbol shown opposite and the measuring tool switches itself off. In this case, have the measuring tool checked by an after-sales service agent for Bosch power tools.

Troubleshooting

Temperature warning
Symbol for temperature warning is shown in the display, operation not possible
Cause: Measuring tool is outside the operating temperature of –10 °C to +45 °C
Corrective measure: Wait until the measuring tool reaches the operating temperature.
Battery indicator
Symbol for battery warning appears
Cause: Battery voltage too low
Corrective measure : Change the batteries.

“Error” in the Display

“Error” indicator in the display
Cause: Target surface is reflecting too strongly (e.g. mirror) or too weakly (e.g. black material), or ambient light is too strong
Corrective measure: Use a laser target plate (accessory)
Cause: Laser beam output (11) or reception lens (10) is fogged up (e.g. due to rapid temperature change)
Corrective measure: Rub the laser beam output (11) or the reception lens (10) dry with a soft cloth
Cause: The measuring tool was moved too quickly.
Corrective measure: Move the measuring tool more slowly.
Cause: The measuring object is outside of the range of the laser beam.
Corrective measure: Go closer to the measuring object.
Measurement Result
Measurement result unreliable
Cause: Target surface is not reflecting clearly (e.g. water, glass)
Corrective measure: Cover the target surface
Cause: Laser beam output (11) or reception lens (10) is concealed
Corrective measure: Always keep the laser beam output (11) and the reception lens (10) clear
Measurement result implausible
Cause: Obstacle in the course of the laser beam
Corrective measure: Ensure that the laser point is fully on the target surface

Display Unchanged

The display remains unchanged or the measuring tool reacts unexpectedly to pressing the measuring button/ buttons
Cause: Software error
Corrective measure: Remove the non-rechargeable batteries/rechargeable batteries and restart the measuring tool after reinsertion

Licence Texts and Legal Notes

Here you will find information about the licences and legal notes as well as the QR code for accessing the Bosch Professional website.
Upon starting the measuring tool, press and hold the   and buttons simultaneously until more information is displayed.
Navigate to the required entry with the button and confirm with the button.

Maintenance and Service

Maintenance and Cleaning
Keep the measuring tool clean at all times.
Never immerse the measuring tool in water or other liquids.
Wipe off any dirt using a damp, soft cloth. Do not use any detergents or solvents.
Take particular care of the reception lens (10), which must be handled with the same level of care you would give to a pair of glasses or a camera lens.
Send in the measuring tool if it requires repair.
After-Sales Service and Application Service
Our after-sales service responds to your questions concerning maintenance and repair of your product as well as spare parts.
You can find explosion drawings and information on spare parts at: www.bosch- pt.com
The Bosch product use advice team will be happy to help you with any questions about our products and their accessories.
In all correspondence and spare parts orders, please always include the 10‑digit article number given on the nameplate of the product.
Malaysia
Robert Bosch Sdn. Bhd.(220975-V) PT/SMY
No. 8A, Jalan 13/6
46200 Petaling Jaya
Selangor
Tel.: (03) 79663194
Toll-Free: 1800 880188
Fax: (03) 79583838
E-Mail: kiathoe.chong@my.bosch.com
www.bosch-pt.com.my
You can find further service addresses at: www.bosch- pt.com/serviceaddresses

Disposal

Measuring tools, accessories and packaging should be recycled in an environmentally friendly manner.
Do not dispose of measuring tools or batteries with household waste.

Accessories

You can find the accessory on the Bosch website via the link given

BOSCH logo Laser target plate (12) 2 607 001 391
Laser viewing glasses (red) (13) 1 608 M00 05B
Robert Bosch Power Tools GmbH
70538 Stuttgart • GERMANY
www.bosch-professional.com
1 609 92A 82K (2022.12) O / 119
BOSCH GLM 30-23 Professional Laser Measure - Bar code

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals