amazon basics B083V7N13J Laser 100m Distance Meter Instruction Manual

June 14, 2024
amazon basics

amazon basics B083V7N13J Laser 100m Distance Meter

amazon basics B083V7N13J Laser 100m Distance Meter

IMPORTANT SAFETY INSTRUCTIONS

Read these instructions carefully and retain them for future use. If this product is passed to a third party, then these instructions must be included.

When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and/or injury to persons including the following:

The safety features of this product may not protect the user if not used in accordance with this user manual.

  • This product must be used by trained users only.
  • Do not use if the product appears damaged or if it is not working property. If in doubt, replace the product.
  • Do not attempt repairs. There are no user serviceable parts.
  • Do not deactivate safety systems and remove explanatory and hazard labels.
  • Do not use this product around explosive gases, vapors, or in damp or wet environments.

Take special precautions when working on scaffolding or heights, for example while using a ladder. Use the right type of ladder and ensure it is structurally sound. Use the ladder in accordance with the manufacturer’s instruction.

  • Never aim a laser beam at any aircraft. The laser beam can distract or flash blind pilots. The laser beam continues to travel even if the light is no longer visible.
  • Ensure adequate safeguards, for example reflective safety vest, at the surveying site (e.g. when measuring on roads, construction sites, etc.).
  • Store the product out of reach of children.

Laser Warnings

Risk of injury! Looking directly into the beam with optical aids (e.g. binoculars, telescopes) can be hazardous.

Risk of injury! Never look into the laser beam and never point it at people or animals. Laser radiation can seriously damage your eyes.

If operation settings or procedures other than those described in these instructions are used, it could lead to exposure to dangerous radiation.

  • This device produces a visible laser beam which is emitted from the front of the product.
  • Do not stare into the laser beam or direct it towards other people.
  • Blinding by laser radiation can indirectly lead to serious accidents, especially for people who are driving a vehicle or operating machinery.
  • When operating the laser equipment, always make sure that the laser beam is directed so that no one is in the projection area and that unintentionally reflected beams (e.g. from reflective objects) cannot be directed into areas where people are present.
  • Laser beam can be dangerous, if the laser beam or its reflection enters unprotected eyes. Always familiarize yourself with statutory regulations and operating instructions before using laser equipment.
  • If laser radiation enters your eyes, close your eyes immediately and move your head away from the beam.
  • If your eyes have been irritated by laser radiation, do not continue to carry out tasks with safety implications, such as working with machines, working from great heights or close to high voltage. Also, do not operate any vehicles until the irritation has completely subsided.

Battery Warnings

  • Always insert batteries correctly with regards to polarity (+and-) marked on the battery and the product.
  • Do not mix old and new batteries or batteries of different types or brands.
  • Exhausted batteries should be immediately removed from product and properly disposed.
  • Keep batteries out of the reach of children.
  • Do not dispose of batteries in fire.
  • Remove batteries from product if it is not to be used for an extended period of time.
  • If the battery leaks avoid contact with skin and eyes. Rinse affected areas immediately with plenty of clean water, then consult a doctor.

Explanation of Symbols

The signal word that indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury.

The signal word that indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury.

Indicates a practical tip, advice or practice not related to personal injury.

This symbol stands for “Conformite Europeenne”, which means “Conformity with EU-directives”. With the CE marking the manufacturer confirms that this product complies with applicable European directives and regulations.

General warning sign.

Class II laser product.

CAUTION LASER RADIATION DO NOT STARE INTO BEAM CLASS II LASER PRODUCT

Product Description

Keypad

Keypad

Backside

A On/MEAS button

B Timer button

C Single/continuous distance measurement button

D Area/Volume button

E Storage button

F Plus (+) button

G CLR/Off button

H Reference button

I Tilt / take out button

J Indirect measurement button

K Minus(-) button

L Illumination/Unit button

M Measurement button

N Multifunctional endpiece

O Tripod thread

P Battery compartment cover

Display

Display

  1. Laser on indicator

  2. Reference level (front)

  3. Reference level (rear)

  4. Reference level (tripod)

  5. Reference level (endpiece)

  6. Area/volume measuring functions
    Area measurement
    Volume
    measurement

  7. Variable measuring functions
    Single Pythagorean measurement
    Dual Pythagorean measurement
    Dual Pythagorean (partial height) measurement
    Tilt measurement

  8. Stake out function

  9. Battery status

  10. Single distance measurement

  11. continuous measurement & Max and Min measurement

  12. Error warning

  13. Logbook

  14. Timer

  15. Tilt angle

  16. Intermediate line 1

  17. Intermediate line 2

  18. Intermediate line 3

  19. Summary line

Intended Use

  • The product is intended for measuring distances, areas, volumes and angles.
  • The readings can be added and subtracted. Height can also be measured using the indirect measuring procedure.
  • The product is suitable for use in dry areas only. Contact with moisture, e.g. in bathrooms, must be avoided at all times.
  • No liability will be accepted for damages resulting from improper use or non-compliance with these instructions.

Changing Batteries

Replace the batteries when the “ ” symbol flashes on the display.

Changing Batteries

  1. Slide the locking tab to the right and remove the battery compartment cover.
  2. Insert 2 x AA 1.5 V batteries correctly with regards to polarity (+and-) marked on the battery and the product.
  3. Attach the battery compartment cover to the meter.

Operation

Switching on/off

Press to switch on the product and laser.
CLR\ Press and hold to switch off the meter. The product \81 switches off automatically after 3 minutes of inactivity.

Clear Button

The last action is canceled or the data display is cleared. While in log mode, press the and button simultaneously to clear all readings stored in the memory.

Reference Level Setting

The default reference setting is from the rear of the meter. Press the button to set the reference setting from the front edge. A beep sounds whenever the reference setting is changed. Upon switching on, the reference returns automatically to the default setting (rear reference).

Reference Level Setting

Tripod Reference

Press and hold the button until reference level icon for tripod is displayed.

Multifunctional Endpiece

Use the multifunctional endpiece to take measurement from an edge or from a corner.

  • For measurements from an edge, unfold the end piece and place it against the edge.
  • For measurements from a corner, unfold the end piece, then push it to the left to unfold it further. The reference level icon for end piece is displayed.

Multifunctional Endpiece

Display Backlight

When in poor lighting conditions, momentarily press to switch the backlight on. Momentarily press again to lower the brightness level and momentarily press a third time to turn the backlight off.

Distance Unit Setting

Press and hold to change the type of unit: m, ft. in, ft+in

| Distance| Area| Volume
---|---|---|---
1| 0.000 m| 0.000 m2| 0.000 m3
2| 0.0 in| 0.000 ft2| 0.000 ft3
3| 0 in 1/16| 0.000 ft2| 0.000 ft3
4| 0.000 ft| 0.000 ft2| 0.000 ft3
5| 0’00” 1/16| 0.000 ft2| 0.000 ft3

Measuring

Single Distance Measurement

Press to trigger a distance measurement.
The measured value is displayed immediately.

Continuous Measurement (Tracking)

Press and hold for 2 seconds to activate continuous distance measurement. The single distance measurement icon disappears from the display. Press the button again to stop the measurement.

The product automatically stops the continuous measurement mode after 3 minutes.

Max/Min and Continuous Measurement

in this mode, the product can be moved toward the target, whereby the measured value is updated approx.
every 0.5 seconds. The corresponding Max. and Min. values are displayed dynamically in the first and second line. The continuous measurement is displayed in the summary line.

  • As an example, the user can move from a wall to the required distance, while the actual distance is read  continuously. For continuous measurement, press the button until the indicator for MIN/MAX measurements appears in the display. Press the or button to stop the measurement. The function is terminated automatically after 100 cycles of continuous measurements.

Max/Min and Continuous Measurement

Functions

Addition/Subtraction

The next measurement is added to the previous one.
The next measurement is subtracted from the previous one.
The last measurement is canceled.
Return to single distance measurement.

Area Measurement

  • Press the button once. The symbol appears on the display.
  • Press button to take the first length measurement (e.g. length).
  • Press again to take the second length measurement (e.g. width).
  • The result of the area measurement is displayed in the summary line. The individually measured values are displayed in lines 1 and 2.

Volume Measurement

  • Press the button twice. The symbol appears on the display.
  • Press the button to take the first distance measurement (e.g. length).
  • Press the button to take the second distance measurement (e.g. width).
  • Press the button to take the third distance measurement (e.g. height).
  • The result of the volume measurement is displayed in the summary line. The individually measured values are displayed in lines 1, 2 and 3.

Indirect Measurement

Indirect measurement – determining a distance using 2 auxiliary measurements. This feature is useful for example when measuring heights that require the measurement of two or three measurements, proceed as follows:

  • Press the  button once. The display shows The distance to be measured flashes in the symbol.
  • Aim at the upper point (1) and trigger the measurement by pressing the O button.
  • After the first measurement, the value is saved. Keep the meter aligned horizontally between the first and second measurement.
  • Press the button to measure the distance of the horizontal point (2).
  • The distance of the function is displayed in the summary line.

Moving the meter horizontally between readings will effect measurement results.

Indirect Measurement – Determining a Distance

Using 3 Measurements

  • Press the button twice. The display shows The distance to be measured flashes in the symbol.
  • Aim at the lower point (1) and trigger the measurement. After the first measurement, the value is saved. Keep the product aligned horizontally between the first, second and third measurement.
  • Press the button to measure the distance result of the horizontal point (2).
  • Press the button to measure the distance result of the upper point (3). The result of the measurement is displayed in the summary line.

Moving the meter horizontally between readings will effect measurement results.

Indirect Measurement - Determining a Distance

  • Press the button 3 times. The display shows The distance to be measured flashes in the symbol.
  • Keep the product aligned horizontally between the first, second and third measurement and press the button to trigger the measurement.
  • Press the button to measure the distance of the middle point (2).
  • Press the button to measure the distance of the upper point (3). The result of the function is displayed in the summary line.

Moving the meter horizontally between readings will effect measurement results.

Logbook

Press the button to open the logbook. The previous 99 records (measurements or calculated results) are shown in reverse order.
Use the or button to navigate through these records.
Press and hold the and button simultaneously to clear all records from the logbook.

Timer (self-triggering)

  • Press the button to set a 5-second time delay. Use the
    buttons to change the timer one second at a time, or press and hold the buttons to make rapid changes.
    The measurement will be made when the timer reaches 0.

  • 2 seconds before the measurement is taken the laser will flash and beep faster.

  • To cancel the timer, press the button.

Stake out function

The stake out function can be used to repeatedly measures a defined length (distance). Two lengths (A, and B) can be registered and then transferred to a surface. For example to enable material to be cut into pieces of equal lengths or to install stud walls in a drywall construction.

Stake out function

Entering stake out distances

  • Press and hold the button. The stake out function symbol appears on the display. The distance A flashes on the display.
  • Use the buttons to adjust the values (first A and then B). Press and hold the buttons to speed up increasing/decreasing the values.
  • Once distance A is set, confirm it by pressing the button.
  • Now set the distance B and confirm by pressing the button.
  • Press the button to start the measurement. Slowly move the meter along the stake out line away from the starting point. The defined length and the current measured value are shown on the display. The meter starts to beep at a distance of 0.33 ft (0.1 m) from the next stake out point.
  • The arrows on the display indicate in which direction the product needs to be moved in order to achieve the defined distance (either A or B). As soon as the stake out point is reached, the beep changes and the intermediate line starts to flash.
  • The function can be stopped at any time by pressing the or button.

Tilt Measurement

The inclination sensor measures tilts between ± 90°. During tilt measurement, the product should be held without a transverse tilt (± 10°).

  • Press the  button once to activate the tilt sensor.
  • The display shows The tilt value is displayed in the intermediate line 1 .
  • Press the O button to measure the inclination and the distance.
  • The distance (L) is displayed in the summary line. The distance (A) (B) calculated by a and L is displayed in intermediate lines 2 and 3.

Tilt Measurement

Measuring Conditions

Measuring Range

  • The range is limited to that listed under technical specifications.
  • At night or dusk and if the target is in shadow, the measuring range without a target plate is increased. Use a target plate to increase the measurement range during daylight or if the target has poor reflection properties.

Target Surfaces

  • Measuring errors can occur when measuring toward colorless liquids (e.g. water) or dust-free glass, polystyrene or similar semi-permeable surfaces. Aiming at high gloss surfaces may deflect the laser beam and lead to measurement errors.
  • Measuring against non-reflective and dark surfaces may increase the measuring time.

Tripod Installation

This product can be installed on a tripod with a standard 1/4″ screw mount.

Always place the tripod on a flat and stable surface to prevent it from tipping over.

Troubleshooting

Enor

Code

| Cause| Solution
---|---|---
204| Calculation error| Repeat procedure
| Received signal is too weak and measurement time is too long.
Distance >50 m| Use target plate
209| Received signal is too strong| Target is too reflective (when using target plate)
Enor

Code

| Cause| Solution
---|---|---
252| Temperature is too high| Move the product to a cooler environment
253| Temperature is too low| Move the product to a warmer environment
255| Hardware error| Switch the product on/off several times. If the error code still appears, bring the product to a professional repair centre.

Cleaning and Maintenance

Switch the product off before cleaning.
During cleaning do not immerse the product in water or other liquids. Never hold the product under running water.

Cleaning

  • To clean the product, wipe with a soft, slightly moist cloth.
  • Never use corrosive detergents, wire brushes, abrasive scourers, metal or sharp utensils to clean the product.

Storage

  • Store the product in its original packaging in a dry area.Keep away from children and pets.

Disposal

The Waste Electrical and Electronic Equipment (WEEE) A Directive aims to minimise the impact of electrical and electronic goods on the environment, by increasing re-use and recycling and by reducing the amount of WEEE going to landfill. The symbol on this product or its packaging signifies that this product must be disposed separately from ordinary household wastes at its end of life. Be aware that this is your responsibility to dispose of electronic equipment at recycling centers in order to conserve natural resources. Each Country should have its collection centers for electrical and electronic equipment recycling. For information about your recycling drop off area, please contact your related electrical and electronic equipment waste management authority, your local city office, or your household waste disposal service.

Battery Disposal

Do not dispose of used batteries with your household waste. Take them to an appropriate disposal/collection site.

Specifications

ASIN: B083V7N13J
Model number: 70LD500
Range (use target plate from >50m): 0.05 to 100 m
Measuring accuracy up to 10 m (2a, standard deviation): Typically: ± 1.5 mm””

Units of measurement: m, in, ft
Laser class: Class II
Laser type: 630-670 nm, < 1 mW
Smallest unit displayed: 1 mm
Tilt measurements: ±90°
Tilt sensor:
Measuring range Accuracy to laser beam and housing (2a, standard deviation): ±0.5°
Dust protected/ splash-proof: IP54
Logs storage: 99
Operating temperature: -10 °C to 50 °C
Storage temperature: -20 °C to 60 °C
Power supply: AA, 2 x 1 .5 V batteries
Battery life: up to 8000 measurements
Auto laser switch-off: after 30 seconds
Auto product switch-off: after 3 minutes
Dimension CvV x H x D): 135 x 53 x 30 mm
Net weight: 165 g
*Use a target plate to increase the measurement range during daylight or if the target has poor reflection properties **For measurements under favorable conditions (e.g., the surface of the measured object has good reflectivity, or indoor temperatures are suitable), precision can be achieved for measurement distances of up to 33 ft (1 0 m). Measurements under unsuitable conditions (e.g., intense sunlight, poor surface reflectivity of the object being measured, or being in environments with large temperature changes), deviation will increase cumulatively by about ± 0.0018 in/ft (± 0.15 mm/m) if the measurement distances are above 33 ft (10 m).

Feedback and Help

Love it? Hate it? Let us know with a customer review.
Amazon Commercial is committed to delivering customer-driven products that live up to your high standards. We encourage you to write a review sharing your experiences with the product.

amazon.co.uk/review/review-your-purchases#
amazon.co.uk/gp/help/customer/contact- usLogo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

amazon basics User Manuals

Related Manuals