AUTENS Air Quality Monitor User Manual

June 14, 2024
AUTENS

Air Quality Monitor
User Manual
(Ver.1.0)

AUTENS Air Quality Monitor

Please read the user manual carefully which can help you to
know the product better for proper using.

Introduction

The air quality monitor can be used for monitoring air quality, HCHO, TVOC, PM2.5, PM1.0, PM10, temperature and humidity. Suitable for home, office, car and other sealed space air quality measurement.

Product View

AUTENS Air Quality Monitor - Product View

How to detect the air quality where I want?

Please turn on the air monitor and leave it alone in a cool and ventilated
place over 1 hour if it is the first time to use or haven’t been used more
than 3 months. Or the result you get may not be accurate.

A. Calibrate the air quality monitor
a. Power on the detector and keep it running for 3 minutes without any operation.
b. Take the detector to area outdoor where the air is fresh and circulate.
c. Click “C” key to enter the auto calibration interface.
d. Click “A” key to start auto calibration.
e. After 300s (5 min), press the “D” key back to overall interface to finish the calibration.

B. Start to detect air quality
a. Take the air quality monitor to the place where you want to detect.
b. Put the air monitor in a place where is cleaning and keep it running for 5 minutes.
c. Then you will get more stable results of formaldehyde and TVOC.
d. At the same time, you can get the result on the screen as below:

AUTENS Air Quality Monitor - o detect air quality

What can the detector measure?

  1. HCHO (formaldehyde)
  2. TVOC (Volatile Organic Compounds)
  3. PM2.5
  4. PM1.0
  5. PM10
  6. Temperature
  7. Humidity

Air Pollution Level Reference Table

HCHO
Range| PM2.5
Range| Color Bar| Hazard Level| Face
Icon
---|---|---|---|---
<0.061| <35| Green| Fresh|
<0.100| <75| Light Green| Normal
<0.370| <115| Yellow| Poor|
<0.775| <150| Light
Orange| Harmful
<1.181| <250| Orange| Serious|
a181| 250| Red| Danger

“Air Pollution Level” relies on “HCHO” and “PM2.5”.

NOTE:

  1. Please detect air quality from low density environment to high density environment.
  2. Please put machine where is cleaning when detecting the data.
  3. Don’t block the detection port with anything when detecting the data.

Interface Introduction

RT : Click“A”Key to Real-Time interface. (a)
Record : Click“B”key to Record interface. (b)
Calib : Click“C”key to Calibration interface. (c)
Set : Click“D”key to System Set interface. (d)

A. RT(Real-Time Interface)

AUTENS Air Quality Monitor - RT

HCHO : Click “A” key to view formaldehyde real time chart.
TEMP : Click “B” to view temperature Real time chart.
TVOC : Click “C” to view volatile organic compound Real time chart.
PM2.5 : Click “D” to view PM2.5 Real time chart.

Air Pollution Level Suggestion

Color Bar Air Pollution Leve Suggestion
Green Safe Livable
Light Green Normal Temporary Stay
Yellow Light Don’t stay long
Light Orange Medium Should not stay
Orange Serious Leave ASAP
Red Danger Leave now

AUTENS Air Quality Monitor - Real-Time Interfac

Aa. Chart interface:
Start : Click “A” to refresh the chart.
Stop : Click “B” to stop the record on the chart.
Quick : Click”C” to refresh every second.
Slow : Click “D” to refresh every 3 seconds.

B. Record (Record Interface)
This is a recording tool to help you record data in period time. You can use this function to monitor the variety of HCHO, PM2.5, TVOC and temperature.

AUTENS Air Quality Monitor - Record

Rec Gap: It means record a data at regular intervals, range is 5s-120s (8 levels), 5s by default.
Rec NO.: It means the record times, range is 50-500 (8 levels).
Time Left: It will tell you how long it will take to finish the job.
For example, If you set Rec Gap on 10s and Rec NO. On 100, Then the Time Left will be 00:16:40. It means the job will be finished in 16 minutes and 40 seconds.
“ ” or ” ” choose the item of Rec Gap and Rec
No..
” ” and ” ” adjust the number value.

How to record the data in period time?

  1. Set the period time you want.
  2. Start : Click “A” key to start recording. Press again it will rerecord and clear the last data.
  3. Pause : Click “B” key stop recording, press again to continue.
  4. Chart : Click “C” key to view the chart after the time went out.
  5. Detail: Click “D” key to view the record detail.

NOTE:

  1. When you use this function for long time, you should pay attention to the power of the device.
  2. When you start the function, you can’t operate the machine, or it will be interrupted.

C. Calibration Interface

How to calibrate the device?
Please reference Ⅲ-A to Calibrate the  air quality monitor.

AUTENS Air Quality Monitor - period time

D. System Set Interface

AUTENS Air Quality Monitor - System Set Interface

Screen OFF: Auto sleep function of screen.
Default is 10 minutes.
For example, if you select for 10 minutes, the screen will be auto off after 10 minutes without any operation. You can set to 1min, 10min, 30min or Never according to your need.
Shutdown: Timed shutdown. Default is 2 hours.
For example, if you select 2 hours, the device will shut down automatically after 2 hours.
Work Speed: Sensor detection speed.
Brightness: Adjust the brightness of the screen.
You can choose 25%, 50%, 75%, 100% or auto according to your need.
Factory Set: If you restore to factory set, the data you set before will be clear.

Operations:

  1. ” “, ” ” select the channel.
  2. Click “OK” to open the options.
  3. ” “, ” ” select the one you want.
  4. Click “OK” to confirm.
  5. Click “D” to save the settings and back to previous interface.

Da: Sensor

AUTENS Air Quality Monitor - Sensor

Sensor set is used to calibrate the device manually.
When you can’t find an area where the air is clear to calibrate the device or you find that the results are not accurate. You can re-calibrate the device manually with the data of these elements you already know.

FAQ:
If the HCHO value on detector is 0.010, the actual value is 0.013. How to calibrate the device?

  1. Enter the sensor set interface.
  2. Click “ ” or “ ” select HCHO Bias.
  3. Click “ ” to adjust the value to 30%.
  4. Click “C” to save.
  5. Back to overall interface, then the HCHO value is 0.013.

Db: Time

Set the date and time of the device.

AUTENS Air Quality Monitor - Time

Operations:

  1. Click “B” to the time interface.
  2. “ ” and “ ” select the option of year, month, date, hour, min or sec.
  3. “ “, “ ” adjust the value.
  4. Click “D” to save settings and back to system set interface.

Dc: Multiply Interface

AUTENS Air Quality Monitor - Multiply Interface

Click “C” to multifunction interface.
Enter : Click “A” to enter to the child interface.
About: Click “C” to see the information of the product.
Back: Click “D” or “ESC” to previous interface.
“ ” “ ” “ ” “ ” to select the function part.
“Treat HCHO” function is to estimate the cost to clear the formaldehyde.
“Treat Haze” function is to estimate the cost to clear PM2.5 (dust in air).
“Calibrate” function is to calibrate the device automatically.
“Alarm” function is to warn people when the air pollution index reach the setting line.

How to estimate the cost to clear formaldehyde?

  1. Select the “Treat HCHO” or “Treat Haze”
  2. Click “A” or “OK” to the HCHO Calculator.
  3. Click “ “, “ ” to select Room Area, Room Type, HCHO Density or Clear Mode.
  4. Click “ ” “ ” to select the child item according to your situation, press “OK” to confirm.
  5. The “CALC” key will turn gray to yellow.
  6. Click “A” to see the information you need.

Take the same steps to get the information on Haze clean.

Dd: Alarm Interface

AUTENS Air Quality Monitor - Alarm Interface

Stop: Click “A” to stop the alarm when it is working.
Click “B” to set the time of the alarm working (10s, 30s, 1miu).
Click “C” to choose the voice of the alarm (Tune 1, Tune2, Tune3).
Click “D” to turn on/off the alarm.

How to set the standard of HCHO?

  1. Select the “Alarm”.
  2. Click “A” or “OK” to the Alarm Set Interface.
  3. Click “ ” “ ” to set the standard of HCHObetween 0.08mg/m³-0.3mg/m³.
  4. The alarm will be ringing if the HCHO density reaches the value you set and the alarm is on.

Hazard Level Reference in Alarm Interface

Color Bar Hazard Level
Green Fresh
Light Green Normal
Yellow Poor
Light Orange Harmful
Orange Serious
Red Danger

Caution

  1. Do not disassemble privately.
  2. Stop using if the appearance of the device deformed.
  3. Do not use it in high-temperature and high humidity environment.

Technical Parameter

Item Parameter
Display Type LCD
HCHO Test Range 0.000-1.999 mg/m³
TVOC Te st Range 0.000-9.999 mg/m³
PM1.0/PM2.5/PM10 Range 0-999μg/ m³
Temperature Te st Range 32 ℉-122 ℉(0-50℃)
Humidity Te st Range 20-90%RH
Battery Capacity 1200mAh
USB Type Type C
Input 5.0V/1A
Charging Time About 3 hours
Duration Time About 4 hours
Working Environment 41℉-104℉ (5-40℃),<90% RH
Storage Environment  32℉-122℉(0-50℃),<90% RH
Product Dimension 6.14″2.72″1.77″

(1516945mm)
Weigh| 224g

FAQ

Q: When should I calibrate the air quality ?

A : The detector need to be calibrated in theses cases: 1. First time to use. 2. When the results are not accurate. 3. The detector will be used again after storing over 3 months.