QORALUX Smart 0-10v Dimmer User Manual

June 14, 2024
QORALUX

QORALUX-logo

QORALUX Smart 0-10v Dimmer

Product Information

  • The Smart 0-10V Dimmer is a versatile device designed for] controlling the brightness of lights. It can be used in both ingle-switch and multi-switch installations, providing convenience and flexibility in lighting control.
  • The dimmer is intended for indoor use only and is compatible with copper wire.

SAFETY INFORMATION

WARNING: SHOCK HAZARD
Turn OFF the power to the branch circuit for the dimmer and lighting fixture at the service panel. All wiring connections must be made with the POWER OFF to avoid personal injury and/or damage to the dimmer. This device is intended for installation in accordance with the National Electric Code and local regulations in the United States and the Canadian Electrical Code and local regulations in Canada. If you are unsure or uncomfortable about performing the installation, consult a qualified electrician.

Multi-switch wiring
For 3-way installations, please refer to the add-on switch manual.

Single-switch wiring
Before installation, you may wish to change the paddle color to match your wall plate or décor.

  1. Shut off power to the circuit at circuit breaker or fuse box
  2. IMPORTANT! Verify power is OFF to switch box before continuing.
  3.  Remove wall plate
  4. Remove the switch mounting screws
  5. Carefully remove the switch from the switch box. DO NOT disconnect the wires.
  6. There are up to six screw terminals on the dimmer, these are marked:
    • GROUND
    • LINE OR LOAD — Black (connected to power or lighting)
    • LINE OR LOAD — Black (connected to power or lighting)
    • TRAVELER — Red/Other (only in 3-way installations)
    • +/- output terminals
    • NEUTRAL — White
  7. Match these screw terminals to the wires connected to the existing switch.
    • Disconnect the wires from the existing switch. Label wires according to the previous terminal connection.

Observe important wiring information

IMPORTANT! This dimmer is rated for and intended to only be used with copper wire. For indoor use only. Wire gauge requirements Use 14AWG or larger wires suitable for at least 80ºC for supplying line (hot), load, neutral, ground, and traveler connections. The +/- output terminals require 16-26AWG.

Wire strip length
For attachment using the enclosure’s holes, strip insulation 5/8in (16mm).

  1. Connect the green or bare copper ground wire to the GROUND terminal
  2. Connect the black wire from the light to either LINE/LOAD terminal
  3. Connect the black wire from the electrical service panel (hot) to the other LINE/LOAD terminal
  4. Connect the white wire to the NEUTRAL terminal (use a jumper wire if needed)
  5. The traveler terminal is only used for 3-way or 4-way wiring and should not be connected
  6. if the dimmer is being installed in a 2-way system (one switch & one load)
  7. Insert dimmer into the switch box being careful not to pinch or crush wires
  8. Dimmer must be independently mounted (vertical position only)
  9. Secure the dimmer to the box using the supplied screws
  10. Mount the wall plate and reapply power to the circuit at fuse box or circuit breaker and test the system
  • Manually from the front panel of the dimmer
  • Remote on/off/dim control

Manual control
The front panel rocker dimmer allows the user to

Turn ON/OFF the connected fixture

  1. To turn the connected fixture ON, press and release the top of the rocker
  2.  To turn the connected fixture OFF, press and release the bottom of the rocker

Adjust dim levels

  1. To increase brightness, press and hold the top of the rocker
  2. To decrees brightness, press and hold the bottom of the rocker

Cycle LED Light The LED below the dimmer acts as a guide light or status indicator. How to cycle through options: Press up three times and down once quickly.

  1. LED is ON when the load is OFF (default)
  2. LED is ON when the load is ON (indicates the dimmer is ON)
  3.  LED is OFF all the time

Add reworked illustrations

Specifications

  • Model : QZ10D-01
  • Max Load :
  • Resistive : 8A@120V/ 5A@277V
  • Electronic Ballast : 960VA@120V/ 1385VA@277V General Use
  • ( Inductive ): 960VA@120V/ 1385VA@277V
  • Power requirement : 120VAC / 60Hz, 277VAC / 60Hz
  • Operating ambient
  • temperature : 0-40°C

FCC
Supplier’s Declaration of Conformity

47 CFR 2.1077 Compliance Information Model: QZ10D-01
Responsible Party – US Contact Information 2520 Marsh Lane, Carrollton, TX 75006-2401 214-785-6510
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

NOTE : The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications or changes to this equipment. Such modifications or changes could void the user’s authority to operate the equipment.

IC
This device complies with Part 15 of the FCC Rules and with RSS of Industry Canada. Operation is subject to the following two conditions

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

FCC

  • This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
  • This equipment should be installed and operated with a minimum distance of 20cm between the radiator and any part of your body.

IC

  • This equipment complies with ISED RSS-102 radiation exposure limits set forth for an uncontrolled environment.
  • This equipment should be installed and operated with a minimum distance of 20cm between the radiator and any part of your body.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>