**Conference System User Manual**
The meaning of symbols
■ Safety instructions
For your safe and correct use of equipment, we use a lot of symbols on the
equipment and in the manuals, demonstrating the risk of body hurt or possible
damage to property for the user or others. Indications and their meanings are
as follow. Please make sure to correctly understand these instructions before
reading the manual.
■ General information instructions
Important note
Warning
In order to ensure the reliable performance of the equipment and the safety of
the user, please observe the following matters during the process of
installation, use and maintenance:
The matters needing attention of installation
- Please do not use this product in the following places: the place of dust, soot and electric conductivity dust, corrosive gas, combustible gas; theplace exposed to high temperature, condensation, wind and rain; the occasion of vibration and impact. Electric shock, fire, wrong operation can lead to damage and deterioration to the product, either;
- In processing the screw holes and wiring, make sure that metal scraps and wire head will not fall intothe shaft of controller, as it could cause a fire, fault, or incorrect operation;
- When the installation work is over, it should be assured there is nothing on the ventilated face, including packaging items like dust paper. Otherwise, this may cause a fire, fault, incorrect operation for the cooling is not free;
- Should avoid wiring and inserting cable plug in charged state, otherwise it is easy to cause the shock, or electrical damage;
- The installation and wiring should be strong and reliable, contact undesirable may lead to false action;
- For a serious interference in applications, should choose shield cable as the high frequency signal input or output cable, so as to improve the anti-jamming ability of the system.
Attention in the wiring
-
Only after cutting down all external power source, can install, wiring operation begin, or it may cause electric shock or equipment damage;
-
This product grounds by the grounding wires. To avoid electric shocks, grounding wires and the earth must be linked together. Before the connection of input or output terminal, please make sure this product is correctly grounded;
-
Immediately remove all other things after the wiring installation. Please cover the terminals of the products cover before electrification so as to avoid cause electric shock.
Matters needing attention during operation and maintenance
- Please do not touch terminals in a current state, or it may cause a shock, incorrect operation;
- Please do cleaning and terminal tighten work after turning off the power supply. These operations can lead to electric shock in a current state;
- Please do the connection or dismantle work of the communication signal cable, the expansion module cable or control unit cable after turning off the power supply, or it may cause damage to the equipment, incorrect operation;
- Please do not dismantle the equipment, avoid damaging the internal electrical component;
- Should be sure to read the manual, fully confirm the safety, only after that can do program changes, commissioning, start and stop operation.
Matters needing attention in discarding product
- Electrolytic explosion: the burning of electrolytic capacitor on circuit boards may lead to explosion;
- Please collect and process according to the classification, do not put into life garbage;
- Please process it as industrial waste, or according to the local environmental protection regulations.
Version
About this manual
This manual introduces how to use or install the conference system in the
common way and how
to control it by commands. We insist you reading the SAFETY INSTRUCTIONS
and QUICK
START before using it. In most of our user manual, we are putting
important note, instructions
and hints in frames of different color, please pay attention to those symbols.
NOTE : This information is the supplementary explanation to the contents, usage or glossary.
CAUTION : Avoid improper operations to damage the products or third-party devices connecting to it.
Safety Instructions
Avoid plug in power connector with power on, otherwise will lead to electric
shock, or cause damage to the circuit
Installation and wiring must be solid and reliable, otherwise it may result in
malfunction on device.
Make sure the device has been well connected to the ground before using
Do not touch the terminals while power on, or may cause electric shock,
malfunctions
Do not disassemble the equipment without permission, to avoid damage to the
internal electrical components and will void the warranty.
The user manual gives the installers and operators the guide to install,
configure and operate the
CLEACON system.
Copyright: VISSONIC Electronics Limited.
System Overview
The CLASSIC-D system is based on the AUDIO-LINKTM audio distribution and processing technology. The system is combined with wired CAT5 and can be used for camera tracking and simultaneous controlling by PC software.
Figure 2.1 CLASSIC-D system overview
The CLASSIC-D system comprises:
- Full Digital Networked Conference Controller VIS-DCP1000
- CAT5 Digital Discussion Chairman/Delegate Unit VIS-DEC-T/VIS-DED-
- CAT5 Digital Discussion Chairman/Delegate Unit with Physical Button VIS-DOC-T/VIS-DOD-T
2.1 Conference Controller VIS-DCP1000
The full digital networked conference controller VIS-DCP1000 controls all the
units in the chain, and supplies power to all. You can configure it by the
button on front panel.
Figure 2.1.1 Front and rear view of VIS-DCP1000
On front panel, the controller contains:
-
Power Switch – Power on or off the controller.
-
Conference Mode Selector – Show the current conference mode status and select the mode option as “Open”, “Apply”, “Voice”, “Override”.
-
Maximum Active Delegate Unit Quantity – Show the current maximum active delegate unit microphone quantity and select the quantity option as “1”, “2”, “4”, “6”.
-
Volume Buttons – Control output volume level of the system.
-
Audio Recording – Press to start/stop recording the audio of whole conference content.
-
USB Slot – To insert USB disk (Up to 32G) for recording, with status light indicator which is flashing during the recording. On rear panel, the controller contains:
-
Audio Inputs (IN 1) – RCA audio input from external audio sources like MP3.
-
Audio Inputs (IN 2) – XLR audio input from external audio sources like Microphone and remote audio input.
-
Audio Outputs (OUT 1) – RCA audio output to external audio devices like PA system, loudspeakers etc. and can be set as zone output.
-
Audio Outputs (OUT 2) – XLR audio output to external audio devices like PA system, loudspeakers etc. and can be set as zone output.
-
Audio Outputs (OUT3) – Phoenix audio output.
-
CU/DU – Connect to the delegate unit, chairman unit and interpreter unit. The CU/DU port 1 and CU/DU port 2 or CU/DU port 2 and CU/DU port 3 can be the closed loop.
-
Control – Female DB9 connector is used to connect with camera auto-tracking controller.
-
Control – Male DB9 connector is used to connect with the camera (or third-party central
control device). -
Ethernet – Connect to PC or switch for the software control.
-
Ground Screw – Connect the controller to the ground.
-
Power Inlet – Connect the controller to the power supply with a power cable (100-240V AC,
50/60Hz, 150W).
2.2 Conference Unit VIS-DEC-T/VIS-DED-T
Figure 2.2.1 Full Digital Discussion Chairman Unit VIS-DEC-T
Figure 2.2.2 Full Digital Discussion Delegate Unit VIS-DED-T
- Microphone Socket – Connect a pluggable gooseneck microphone (Model no.: VIS-M330, VIS-M410, VIS-M485, VIS-M600) to the discussion units.
- Loudspeaker – Give the audio signal from the floor to the delegate unit, when the microphone is enabled, the signal of the loudspeaker is muted.
- Headphone Socket – Headphone connection.
- Volume Knob – Adjust the earphone and speaker volume.
- Clear Button – Clear/deactivate all active delegate unit microphone or mute the system.
- Microphone Button – Enables or disables the microphone. The microphone button has a LED that shows the condition of the microphone.
- Approval Button – Approve the applying microphone to be enabled under the apply mode and work as mute while pressed clear button.
- CU/DU RJ45 Socket – Makes a loop-through in the CEALCON system with the discussion unit.
2.3 Conference Unit with Physical Button VIS-DOC-T/VIS-DOD-T
Figure 2.3.1 Full Digital Discussion Chairman Unit with Physical Button VIS- DOC-T
Figure 2.3.2 Full Digital Discussion Delegate Unit with Physical Button VIS- DOD-T
- Microphone Socket – Connect a pluggable gooseneck microphone (Model no.: VIS-M330, VIS-M410, VIS-M485, VIS-M600) to the discussion units.
- Loudspeaker – Give the audio signal from the floor to the delegate unit, when the microphone is enabled, the signal of the loudspeaker is muted.
- Headphone Socket – Headphone connection.
- Volume Knob – Adjust the earphone and speaker volume.
- Clear Button – Clear/deactivate all active delegate unit microphone or mute the system.
- Microphone Physical Button – Enables or disables the microphone. The microphone button has a LED that shows the condition of the microphone.
- Approval Button – Approve the applying microphone to be enabled under the apply mode and work as mute while pressed clear button.
- CU/DU RJ45 Socket – Makes a loop-through in the CEALCON system with the discussion unit.
System Design and Plan
Before using our conference system, there are some basic points for you to
plan/design a conference room.
The controller is powered by 110V to 220V wide range power supply, while it
has a basic control capacity (with power relay devices it can load more
units). Here we list a basic capacity of active units for one controller.
The capacity is decided by:
- Number of active units in the system.
- Length of extension cable from the first delegate or chairman unit to conference controller VIS-DCP1000.
NOTE : Extension cable has direct effect on the control capacity. The longer extension cable is used, the less power is available to drive the devices connected in the system. The length of the cable needs to be selected according to the practical situation.
3.1 Install in the 19’ rack
The conference controller VIS-DCP1000 can be installed in a standard 19-inch cabinet. The unit has standard accessories of a pair of installation supports. Below is the following diagram for installation:
Figure 3.1 Installation of the conference controller
Connection
4.1 Power supply
Figure 4.1 Power connection
Connect the conference controller and the power supply firmly together.
CAUTION : Main power supply should well grounded, otherwise it may cause fatal incident.
4.2 Audio inputs
Figure 4.2 Audio input connection
The conference controller provides RCA or XLR type audio input connector.
4.3 Audio outputs
Figure 4.3 Audio output connection
The conference controller provides RCA, XLR or phoenix type audio output connector
4.4 CU/DU
Figure 4.4 CU/DU port
Use the CU/DU socket to connect to the chairman/delegate unit or extension
main unit. Use the VISSONIC tested CAT5e cable or better.
There are three connection ways available for CLASSIC-D conference system.
♦ Hand in Hand Loop Network
Hand in Hand Loop Network is an important feature for CLASSIC-D conference
system.
You can use this connection way to make the system steadier.
Figure 4.4.1 Hand in Hand Loop Network connection
“Hand-in-Hand-Loop-Network” connection is only available between CU/DU1 and CU/DU2, or CU/DU2 and CU/DU3, but not valid between CU/DU1 and CU/DU3.
♦ Hand in Hand connection
Figure 4.4.2 Hand in Hand connection
♦ Hand in Hand connection + Hand in Hand Loop connection
Figure 4.4.3 Hand in Hand connection + Hand in Hand Loop connection
♦ Extension Main Unit + Hand in Hand Loop connection
Figure 4.4.4 Extension Main Unit + Hand in Hand Loop Connection
4.5 CONTROL
Figure 4.5.1 Control Port
Full digital conference system can be compatible with various control systems via RS232 serial interface. The upper COM port is used to connect with camera auto-tracking controller for camera auto-tracking function. The lower COM port is used to connect the camera (or third-party central control device).
The default switching command is
Baud rate: 9600 bps; Parity: 8; Stop: 1
If you need other commands, please contact with us to upgrade the firmware
online.
COM port pin is described as follows:
Figure 4.5.2 Description of COM port pin
RS232 (DB9 female/pin type) pin definition (Upper COM of conference controller)
RS232 (DB9 male/pin type) pin definition (Lower COM of conference controller)
4.6 ETHERNET
Figure 4.6 ETHERNET port
Connect the ETHERNET socket to the PC by CAT5 cable or better.
Configuration and Operation
5.1 Configuration on the VIS-DCP1000
Use the configuration menu of the conference controller to configure the
system.
5.1.1 Basic Setting
Figure 5.1.1 Front panel of VIS-DCP1000
The indicators show the system working status MIC mode “Override, Voice, Open, Apply”, the maximum active number “1, 2, 4, 6”, volume output “0dB, -3dB, -5dB, -10dB, -15dB, -20dB” and USB recording status.
MIC MODE
On the main screen, press the button “Mode” to set the microphone mode. When
the conference controller is connected to the PC, you also can set the
microphone mode from the PC software.
ACTIVE MICRO’S
Press the button “ACTIVE MICRO’S” to change the max active unit MIC number.
Volume
Press the button “Volume▲” and “Volume▼” to change the volume output of
conference controller.
REC.
Insert the USB disk to the USB sock and press the button “REC.” to start
recording and the indicator is flashing.
5.1.2 Turn ON/OFF the built-in speaker of the delegate/chairman unit
Figure 5.1.2 Button of VOLUME
Press the button “VOLUME▲” and “VOLUME▼” at the same time and hold, all indicators will be lighting and off. The setting is accepted and the speaker built-in delegate/chairman unit be on/off status reversely.
5.1.3 Setting ID for chairman/delegate unit
Figure 5.1.3 Button of MODE and ACTIVE MICRO’S
During the working status, press the button “MODE” and “ACTIVE MICRO’S” at the same time, all LED indicators start on/off flashing. The system is working on the setting ID mode.
Just press the MIC button on every chairman/delegate unit one by one and set
the ID for them.
After finished pressing chairman/delegate unit, press the button “MODE” and
“ACTIVE MICRO’S” at the same time, all indicators stop flashing and the ID
setting is saved and finished.
5.1.4 Setting the default system
Figure 5.1.4 Button of Switch, MODE and ACTIVE MICRO’S
- Turn off the system.
- Press the button “MODE” and “ACTIVE MICRO’S” at the same time and hold.
- Switch on the system.
- All the indicators will be lighting on/off two times and release the buttons.
- The default setting is ok.
5.1.5 Camera Auto-tracking Setup & Application
Here we need to install the software “VIS-DCP1000 Conference Controller Setup
Software” and set your PC to the same IP range: 192.168.10.XXX, defualt
gateway: 192.168.10.1. as shown below.
Figure 5.1.5 IP address and gateway of PC
Use CAT5 network cable to connect the network port of the PC and the Ethernet port of the VIS-DCP1000. Click the “Connect” button on the software and start set the camera tracking.
Figure 5.1.6 Connect VIS-DCP1000
Figure 5.1.7 Camera setting interface
Application example
For example, we want to set up two cameras, using VISCA, SAMSUNG/PELCO-D or
CUSTOM protocol, as follows.
-
Application example
For example, we want to set up two cameras, using VISCA, SAMSUNG/PELCO-D or CUSTOM protocol, as follows.
♦ Camera using VISCA protocol.
♦ Camera using SAMSUNG/PELCO-D protocol. -
Connect the upper COM of CONTROL port of the controller to the camera auto-tracking controller (VIS-CATC-A).
♦ Use RS232 to connect camera auto-tracking controller VIS-CATC-A. -
If using the CUSTOM protocol, there is no need to set the submenus “Camera map”, “Setting” and no need to execute “Tracking setting steps”.
-
If using the VISCA or the SAMSUNG/PELCO-D protocol:
a) Enter the submenu “Camera map”, select a camera, set the address of the camera and bind it.
For details, refer to the menu parameter description in this chapter;
b) According to “Tracking setting steps”, set all cameras by the “VIS-DCP1000 Conference Controller Setup Software” software and operate camera by remote control.
5.2 Chairman/delegate unit operation
Microphones
The colors of the LEDs of the microphone buttons and the LED ring of MIC show
the condition of the microphone that connected to the discussion unit.
4/F, Building 6, No. 50 Nanxiang 1st Road, Huangpu District, Guangzhou, China