NewQ NQ-SL-01 Fingerprint Deadbolt Door Lock User Manual
- June 14, 2024
- NewQ
Table of Contents
**NewQ NQ-SL-01 Fingerprint Deadbolt Door Lock User Manual
**
PACKAGE CONTENTS
-
Outdoor panel
-
Indoor panel
-
Mounting plate
-
Lock shell.
-
Strike Plate
-
Deadbolt latch
-
STt4.0x20 Screw x5
-
PHO Screw x2
-
M6x55 Screw *2
-
IC card x2 Key x2
PRODUCT DIAGRAM
INSTALLATION INSTRUCTIONS
Video version
Installation steps of the video version-Please scan the QR code below to check
it
Picture version
- Insert deadbolt latch into door holes
-
Positioning plate and lock shell are installed on the door frame
-
Installing front plate
-
Remove the mounting plate
-
Thread the cable through the bottom of the mounting plate.
-
Tighten the screws
-
Ensure that the cable is closely connected
-
Tighten the screws
-
Insert the key and test the lock. If the lock does not extend or retract, adjust the screws on the mounting plate
-
If the mounting plate and keyboard are deflected, loosen the mounting plate screws and adjust the mounting plate
FUNCTION&OPERATIONS
Description of door lock ID
- In the initial state, the password is 123456, and the password is invalid after entering a new administrator password
- User roles
A. In order to facilitate password management, each password corresponds to an ID number.
B. The number of passwords that can be stored in the door lock is 99 groups of passwords shared by fingerprints passwords, and IC cards
C. The length of the password is 6-12 digits.
Note: Please touch to wake up the keyboard before use.
Role name | Password type | ID number |
---|---|---|
Administrator | Fingerprint/Password | 001-009 |
Normal user | Fingerprint/Password /IC card | 010-099 |
The administrator password has more privileges than the normal user.
Function setting
Admin Settings
A. Adding Administrator Passwords
For the first time setting, admin info is the admin initial password “123456”
The length of the password is 6-12 digits.
Add Fingerprint (need to input 5 times) Add Password (need to enter twice) Add IC card (need to input once)
Note:
- The initial password 123456 will be invalid after setting up a new administrator password for the first.
- Please remember at least one administrator password, as this information is required to access the settings.
- You can also add other types of unlocking ways such as fingerprints, and IC cards as an administrator , and support up to 9 admin accounts.
B. Delete Administrator
Note :
- Administrator ID number 001 cannot be deleted after registration. If you want to delete it, you can only initialize it.
- After the administrator is deleted, the number vacancy will be automatically filled in the next administrator registration
Users Settings
A. Adding Users
B. Delete Users
System Setting
A. Volume setting
B. Language selection
C. Automatic locking
**Restore Factory Settings
**
Note :
- After successfully restoring the factory settings, the specific information cleared is as follows: passwords, fingerprints and cards set by the door lock.
- a. All
- b. The settings corresponding to the door lock menu function will be delivered to the default value.
- After initialization, any fingerprint or initial password “123456” can unlock and verify the administrator to enter the administrator menu
Other instructions
F unction | Functional description | Applicable scenario |
---|---|---|
Anti-peep tech | The correct password contains irrelevant codes before and |
after, and pressing the unlock key can still unlock
| The surrounding environment is unsafe or the password is entered incorrectly
Low electric alarm| When the battery pressure is lower than 4.8V when
unlocking, the door lock will automatically give an alarm (voice broadcast
“battery low”).| Insufficient power, please replace the battery.
Error alarm| When unlocking, the fingerprint, password and card are wrong for
five times, and the door will be locked automatically. At the same time, it
will broadcast “System locked”| Someone tried to unlock the lock.
SPEAIFICATIONS
Ordinal | Item | Parametric | Remark |
---|---|---|---|
1 | Quiescent current | s80uA | |
2 | Dynamic current | *300mA | |
3 | Fingerprint collector | Semiconductor | |
4 | Fingerprint comparison time | :51s | |
5 | Fingerprint recognition angle | 360° | |
6 | Rejection rate | 50.1% | |
7 | False admission rate | 50.0001% | |
8 | Sensing time | 50.5s | |
9 | Power supply type | 4.8-6.4V | |
10 | Emergency power supply | Type-C 5V | |
11 | Operating temperature | -25`C-70°C | |
12 | Operating relative humidity | 20%-90%RH | |
13 | Voice prompts | Yes | |
14 | Keyboard | Standard 12-bit | |
touch keyboard | |||
15 | Password length | 6-12 bits | |
16 | Anti-peep password length | 16bits | |
17 | Low voltage alarm voltage | 4.8 (-0.2V) | |
18 | Unlocking time | 51s |
**WARRANTY &CUSTOMER SERVICE
**
- Any damage to the product within 18 months from the date of purchase, feel free to contact us via email at support@newq.store, and you will get a free replacement after confirmation
- Send “Extended Warranty” to support@newq.store, and you will win the free replacement service from 18 months extended to 60 months (Please send the Order ID when contacting)
- We will release information on new products with large discounts from time to time through the brand mailbox, and you will automatically obtain the rights after obtaining the extended warranty. Welcome to pay attention to the information about our brand.
Read User Manual Online (PDF format)