Product Information
The DM-262 is a versatile measuring device equipped with
advanced design and technology, providing users with a great
experience. It features an operation panel that allows for easy
control and navigation.
Operation Panel
-
Power On: Press the button to turn on the device.
-
Screen Rotation: Long press to rotate the screen.
-
Font Enlargement: Long press to enlarge the font size.
-
Change Unit: Long press to switch between different unit
measurements. -
Addition Left: Press the button to perform addition on the left
side. -
Power Off: Long press to turn off the device.
-
Take Measure: Press the button to start measurement.
-
Measurement References/Bilateral & Unilateral Laser: Long
press to switch between bilateral and unilateral laser measurement
references. -
Mode Menu: Press the button to access the mode menu.
-
Mute Setting: Press the button to enable or disable mute
mode. -
Subtraction Right: Press the button to perform subtraction on
the right side. -
Delete Undo: Press the button to delete or undo previous
actions.
Product Usage Instructions
Selecting Measurement References/Bilateral & Unilateral
Laser
To select the measurement references or switch between bilateral
and unilateral laser measurements, follow these steps:
-
Long press the “Measurement References/Bilateral &
Unilateral Laser” button. -
The screen will display the options for bilateral and
unilateral laser measurements.
Screen Display:
- Rear Reference Bilateral Laser Measurement
- Front Reference Unilateral Laser Measurement
- Rear Reference Unilateral Laser Measurement
- L1
- L
- L
- L2
- L
Selecting Measuring Functions
To select different measuring functions, follow these steps:
-
Short press the “Measuring Functions” button to access the
menu. -
Short press the button again to cycle through the available
functions.
Screen Display:
- Measuring Length
- Real-time Measurement
- Area Measurement
- Volume Measurement
- Indirect Height Measurement
- Double Indirect
- Non-vertical
- Data Recording
- Angle Calibration
Measuring Length
To measure length using bilateral and unilateral laser, follow
these steps:
-
Long press the “Switching Between Bilateral & Unilateral
Laser” button to select the desired laser measurement. -
Short press the “Measuring Functions” button to access the
menu. -
Select “Measuring Length”.
-
Short press the “LEFT & RIGHT” button to choose the desired
function. -
The display will show the measurement result.
Screen Display:
L Unilateral Laser Measurement
L Bilateral Laser Measurement
Real-time Measurement
To perform real-time measurement using bilateral and unilateral
laser, follow these steps:
-
Long press the “Switching Between Bilateral & Unilateral
Laser” button to select the desired laser measurement. -
Short press the “Measuring Functions” button to access the
menu. -
Select “Real-time Measurement”.
-
Short press the “LEFT & RIGHT” button to choose the desired
function. -
The display will show the real-time measurement result.
Screen Display:
L
--L
--L1
--L2
Area Measurement
To measure area using bilateral laser, follow these steps:
-
Long press the “Switching Between Bilateral & Unilateral
Laser” button to select bilateral laser measurement. -
Short press the “Measuring Functions” button to access the
menu. -
Select “Area Measurement”.
-
Short press the “LEFT & RIGHT” button to choose the desired
function. -
The height of the object will be displayed on the screen.
-
The area will be automatically calculated and shown at the
bottom of the screen display.
Screen Display:
H
L
DM-262
USER MANUAL
Design and Technology Make for a Great Experience.
OPERATION PANEL DM-262 OPERATION PANEL
POWER ON
SCREEN ROTATION FONT ENLAREMENT (LONG PRESS)
CHANGE UNIT (LONG PRESS) ADDITION LEFT
POWER OFF (LONG PRESS)
TAKE MEASURE MEASUREMENT REFERENCES/ BILATERAL & UNILATERAL LASER (LONG PRESS)
MODE MENU MUTE SETTING SUBTRACTION RIGHT DELETE UNDO
Inkerma User Manual
MEASUREMENT REFERENCES/ BILATERAL & UNILATERAL LASER
DM-262 SELECTING MEASUREMENT REFERENCES/ BILATERAL & UNILATERAL LASER
How to Use:
Long Press Switching Between Bilateral & Unilateral Laser Selecting the Front
& Back Reference Level
Screen Display:
Rear Reference Bilateral Laser Measurement
Front Reference Unilateral Laser Measurement
Rear Reference Unilateral Laser Measurement
L1
L
L
L2
L
Inkerma User Manual
MEASURING FUNCTIONS DM-262 SELECTING MEASURING FUNCTIONS How to Use:
Short Press Selecting Measuring Functions
Short Press Selecting LEFT & RIGHT Function
Screen Display:
Measuring Length Real-time Measurement Area Measurement Volume Measurement Indirect Height Measurement
Double Indirect
Non-vertical
Data Recording Angle Calibration
Height Measurement Indirect Height Measurement
Inkerma User Manual
MEASURING FUNCTIONS DM-262 SCREEN DISPLAY FOR MEASURING FUNCTIONS
Selecting Measuring Functions Reference Level
Measuring Length Volume Measurement Non-vertical Indirect Height Measurement
Angle Battery Level
Area Measurement Real-time Measurement
Double Indirect Height Measurement Indirect Height Measurement Angle
Calibration
Data Recording
Inkerma User Manual
INSTRUCTIONS FOR USE
DM-262 MEASURING LENGTH
Measuring Length
· Illustrations:
Switching the Bilateral & Unilateral Laser Measurement(Long Press)
L Unilateral Laser Measurement
L Bilateral Laser Measurement
· Operation:
- Short Press Selecting Measuring Functions
Selecting Measuring Length
Short Press Selecting LEFT & RIGHT Function
3.1
A Unilateral Laser
4.1
B · Position DM-262 at the
L
originating point A
· Align the red laser towards point B Of L
· Briefly press the measurements will be
shown at the bottom of the
display
· For horizontal distances, set the angle of DM-262 to 0°. 0.0°
48.2°
3.2
L
A Bilateral Laser
4.2
B · Position DM-262 at any point of L · Align the bilateral red laser towards
point A & B Of L · Briefly press the measurements will be shown at the bottom
of the display · For horizontal distances, set the angle of DM-262 to 0°. 0.0°
48.2°
6.008
L
2.997 3.011
6.008
Left Distance Right Distance
L
Inkerma User Manual
INSTRUCTIONS FOR USE DM-262 REAL-TIME MEASUREMENT
Real-time Measurement
· Illustrations:
Switching the Bilateral & Unilateral Laser Measurement(Long Press)
L
–L
–L1
–L2
A
L
B
Unilateral Laser Measurement Bilateral Laser Measurement
· Operation:
- Short Press Selecting Measuring Functions
Selecting Real-time Measurement
Short Press Selecting LEFT & RIGHT Function
3.1
L
–L
A
B
Unilateral Laser
4.1
48.2°
· Position DM-262 at the originating point A
· Align the red laser towards point B Of L · Briefly press the measurements
will be shown at the bottom of the display
· The DM-262 can be moved relative to B and the current distance –L will be
updated
3.2
–L1
A
4.2
· Position DM-262 at any
point of L
–L2 · Align the bilateral red laser
L
Bilateral Laser
B towards point A & B Of L · Briefly press the measurements will be
shown at the bottom of the
display
· The DM-262 can be moved relative
between A & B and the current distance –L1 & –L2 will be updated
48.2°
MAX 3 . 9 9 7
MAX
MIN 1 . 0 1 1
MIN
2.026
–L
2.997 3.011
6.008
Left Distance –L1 Right Distance –L2 –L
Inkerma User Manual
INSTRUCTIONS FOR USE DM-262 AREA MEASUREMENT
Area Measurement
· Illustrations:
Switching the Bilateral & Unilateral Laser Measurement(Long Press)
H L
Area=L×H
Bilateral Laser Measurement
· Operation:
- Short Press Selecting Measuring Functions
Selecting Area Measurement
Short Press Selecting LEFT & RIGHT Function
-
L
-
· Set DM-262 for horizontal measurement with an angle of 0°. 0.0° · Briefly press the length of L will be shown on the display
H
· Set DM-262 for vertical
measurement with an angle of 90°. 90.0°
· Briefly press
the height of H will be shown on
the display
· After the two measurements are completed,
the area will be calculated automatically and be
48.2°
shown at the bottom of the screen display.
2.100
L
3.100
H
6.510 2
Area
Inkerma User Manual
INSTRUCTIONS FOR USE DM-262 VOLUME MEASUREMENT
Volume Measurement
· Illustrations:
Switching the Bilateral & Unilateral Laser Measurement(Long Press)
H L1
L2
Volume=L1×L2×H
Bilateral Laser Measurement
· Operation:
- Short Press Selecting Measuring Functions
Selecting Volume Measurement
Short Press Selecting LEFT & RIGHT Function
-
L1
· Set DM-262 for horizontal
measurement with an angle of 0°. 0.0°
· Briefly press
L2
the length of L1 will be shown on
the display
- · Set DM-262 for horizontal measurement with an angle of 0°. 0.0° · Briefly press the length of L2 will be shown on the display
· Set DM-262 for vertical
H
measurement with an angle of 90°. 90.0°
· Briefly press
the height of H will be shown on
the display
· After the three measurements are completed,
the volume will be calculated automatically and
48.2°
be shown at the bottom of the screen display.
2.150 3.150 2.850
19.301 3
L1 L2 H Volume
Inkerma User Manual
INSTRUCTIONS FOR USE DM-262 PYTHAGOREAN METHOD
Indirect Height Measurement
· Illustrations:
H=L×Sin
Switching the Bilateral & Unilateral Laser Measurement(Long Press)
L
D
H
90°
L
H
90°
D
Unilateral Laser Measurement Bilateral Laser Measurement
· Operation:
- Short Press Selecting Measuring Functions
Selecting Indirect Height Measurement
Short Press Selecting LEFT & RIGHT Function
C
C
3.1
L
· Position DM-262 at the
3.2
originating point A (Ensure the
H DM-262 is at the same height
L
· Position DM-262 at any
point of L (Ensure one side
H of the red laser is pointing at
90° as the lower measuring point
A
D
B – B Of H)
· Align the red laser towards
Unilateral Laser
the top point- C Of H
· Briefly press
the measurement H will be
shown on the display
90°
A
D
B
Bilateral Laser
the same height as the lower measuring point – B Of H)
· Align the other side of the red laser towards top pointC Of H · Briefly
press the measurement H will be shown on the display
37.0°
37.0 °
5.000
L
4.000
3.000
D
· After the measurement is completed, the
H
height will be calculated automatically based on
the Pythagorean Method and be shown at the
bottom of the screen display.
Inkerma User Manual
INSTRUCTIONS FOR USE
DM-262 PYTHAGOREAN METHOD
Double Indirect Height Measurement
· Illustrations:
Switching the Bilateral & Unilateral Laser Measurement(Long Press)
H=h1+h2=L1×Sin+L2×Sin
L1
h1
H
h1
L2
Unilateral Laser Measurement
L1
h1
H
L2
h1
Bilateral Laser Measurement
· Operation: Unilateral Laser Measurement
Short Press Selecting Measuring Functions
Selecting Double Indirect Height Measurement
Short Press Selecting LEFT & RIGHT Function
C
L1
· Position DM-262 at the
originating point A
H · Align the red laser towards
A
the top point- C Of H
· Briefly press
B the measurement L1 will be
shown on the display
C
L1
· Position of DM-262 remains
unchanged
A
H · Align the red laser towards the lower point- B Of H
L2
· Briefly press
B the measurement L2 will be
shown on the display
· Ensure that the reference level for DM262 remains in the same place during a
single measuring process.
24.1°
51.0 ° 2.565 2.533
2.193
L1
L2
· After the two measurements are completed,
H
the height will be calculated automatically
based on the Pythagorean Method and be shown
at the bottom of the screen display.
Inkerma User Manual
INSTRUCTIONS FOR USE
DM-262 PYTHAGOREAN METHOD
Double Indirect Height Measurement
· Illustrations:
Switching the Bilateral & Unilateral Laser Measurement(Long Press)
H=h1+h2=L1×Sin+L2×Sin
L1
h1
H
h1
L2
Unilateral Laser Measurement
L1
h1
H
L2
h1
Bilateral Laser Measurement
· Operation: Bilateral Laser Measurement
Short Press Selecting Measuring Functions
Selecting Double Indirect Height Measurement
Short Press Selecting LEFT & RIGHT Function
L1
C
· Position DM-262 at any
location within the height
range of H
A
H · Align one side of the red laser
towards point A, and the other
side of the red laser towards
Bilateral Laser B
to the top point- C Of H · Briefly press
the measurement L1 will be
shown on the display
A
L2
24.1°
51.0 °
2.565
L1
2.533
L2
2.193
H
C
· Position DM-262 at any location within the height range of H H · Align one
side of the red laser towards point A, and the other side of the red laser
towards B to the top point- B Of H · Briefly press the measurement L2 will be
shown on the display · Ensure that the reference point A remains in the same
place during a single measuring process.
· After the two measurements are completed, the height will be calculated
automatically based on the Pythagorean Method and be shown at the bottom of
the screen display.
Inkerma User Manual
INSTRUCTIONS FOR USE DM-262 PYTHAGOREAN METHOD
Non-vertical Indirect Height Measurement
· Illustrations:
Switching the Bilateral & Unilateral Laser Measurement(Long Press)
H=L1×Sin-L2×Sin
H L1
L2
L1
H
L2
Unilateral Laser Measurement Bilateral Laser Measurement
· Operation: Unilateral Laser Measurement
Short Press Selecting Measuring Functions
Selecting Non-vertical Indirect Height Measurement
Short Press Selecting LEFT & RIGHT Function
C
H · Position DM-262 at the
L1
originating point A (Ensure
B the height of A is lower than
the bottom point of H-B)
· Align the red laser towards
A
the top point Of H-C
Unilateral Laser
· Briefly press the measurement L1 will be
shown on the display
C
H · Position of DM-262 remains
L1
unchanged
B · Align the red laser towards
L2
the lower point- B Of H
· Briefly press
A
the measurement L2 will be
shown on the display
· Ensure that the reference level for DM262 remains in the same place during a single measuring process.
24.1°
7.0 ° 0.848 0.809
0.108
–
L1
L2
· After the two measurements are completed,
H
the height will be calculated automatically
based on the Pythagorean Method and be shown
at the bottom of the screen display.
Inkerma User Manual
INSTRUCTIONS FOR USE DM-262 PYTHAGOREAN METHOD
Non-vertical Indirect Height Measurement
· Illustrations:
Switching the Bilateral & Unilateral Laser Measurement(Long Press)
H=L1×Sin-L2×Sin
H L1
L2
L1
H
L2
Unilateral Laser Measurement Bilateral Laser Measurement
· Operation: Bilateral Laser Measurement
Short Press Selecting Measuring Functions
Selecting Non-vertical Indirect Height Measurement
Short Press Selecting LEFT & RIGHT Function
C · Position DM-262 at any
H
location(Ensure the height of DM-262 is lower than the top
L1
B point of H-C) · Align one side of the red laser
A
towards point A, and the other side of the red laser towards
to the top point- C Of H
Bilateral Laser
· Briefly press
the measurement L1 will be
shown on the display
- L1
A
24.1°
C
H
B
L2
· Position DM-262 at any location(Ensure the height of DM-262 is lower than
the first position)
· Align one side of the red laser towards point A, and the other side of the
red laser towards to the lower point- B Of H
· Briefly press the measurement L2 will be shown on the display
· Ensure that the reference point A remains in the same place during a single
measuring process.
7.0 ° 0.848 0.809
0.108
–
L1
L2
· After the two measurements are completed,
H
the height will be calculated automatically
based on the Pythagorean Method and be shown
at the bottom of the screen display.
Inkerma User Manual
INSTRUCTIONS FOR USE DM-262 DATA RECORDING
Data Recording
· Operation:
- Short Press Selecting Measuring Functions
Selecting Data Recording
Short Press Selecting LEFT & RIGHT Function
-
24.1° 100
0.800 0.900
1.700
· The memory measurements is shown on the dispaly · Maximum 100 data can be retrieved -
Short Press Selecting the forwards saved values
Short Press Selecting the backwards saved values
Short Press Deleting the Current Value
Inkerma User Manual
INSTRUCTIONS FOR USE DM-262 ANGLE CALIBRATION
Angle Calibration 3.
0°
· Operation:
- Short Press Selecting Measuring Functions
Selecting Angle Calibration
Short Press Selecting LEFT & RIGHT Function
0°
0°
0°
0°
0°
· 01 Angle calibration page
· Place the DM-262 according to the screen instruction
· Short press , the device beep briefly and the will change to ,which means
the device
is in the calibrating process. Wait for 5 seconds, the DM-262 beep long and
the changes to . This indicates that the calibration has been completed.
· 02 Angle calibration page · Place the DM-262 according to the screen
instruction
· Short press , repeat the previous steps until the full process of
calibration is completed.
· 03 Angle calibration page · Place the DM-262 according to the screen
instruction
· Short press , repeat the previous steps until the full process of
calibration is completed.
· 04 Angle calibration page · Place the DM-262 according to the screen
instruction
· Short press , repeat the previous steps until the full process of
calibration is completed.
· 05 Angle calibration page · Place the DM-262 according to the screen
instruction
· Short press , repeat the previous steps until the full process of
calibration is completed.
· 06 Angle calibration page · Place the DM-262 according to the screen
instruction
· Short press , repeat the previous steps until the full process of
calibration is completed.
· 1ST After the completion of the last calibration process, the DM-262 will
automatically shutdown.
Inkerma User Manual
INSTRUCTIONS FOR USE DM-262 ADDING/ SUBTRACTING VALUES
Addition
Subtraction
· Operation:
- Short Press Selecting Measuring Functions
Selecting Measuring Length
Short Press Selecting LEFT & RIGHT Function
-
48.2°
-
Short Press Selecting Addition Function
1.800
· Briefly press the measurement will be
shown at the bottom of the
display
-
· Briefly press the measurements to be added/ subtracted will be shown on the screen display.
-
48.2°
1.800
+ 2.300 4.100 -
Short Press Selecting Subtraction Function
48.2°
1.800
.
· The Addition/ subtraction mark has been displayed on the screen
· After the last measurement is completed, the values will be added/subtracted automatically and be shown at the bottom of the screen display.
Inkerma User Manual
Wishing you a pleasant experience.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>