POWER STATION MOVE 2000

SAFETY INSTRUCTIONS

Please read this manual carefully. The user of this product takes full responsibility for the operation and usage of this product. Please check the local regulations in the area of usage of the product. The user of this product is solely responsible for the usage of this product according to all relevant regulations.

  1. In order to ensure the safety of this product during transportation, this product is only charged about 30% when it is packaged. Please recharge when you get the product. When not using this product, please turn off the power and unplug the power cord.
  2. Only official parts or accessories can be used with this product. If any accessories need to be replaced, please contact Evebase for more information. Do not charge the product with a charging device that does not meet the specified parameters and please do not use extension cords and cable taps.
  3. Do not disassemble the product and don’t perforate it with sharp objects.
  4. A high environmental temperature while using the power station may result in fire or an explosion. Therefore please follow the maximum operating temperature as specified further in this manual. If the temperature is too low, the performance of the  product will go down or the product will stop working.
  5. Only use and store the product in dry and ventilated areas and avoid dust. Please ensure that the air intake and outlet are unblocked when using.
  6. Strictly avoid contact of the product with any liquid. Do not immerse the product into water and make sure it doesn’t get wet. Avoid the usage in rainy or humid places.
  7. In case the power station has fallen into water or is wet, place it in an open area and keep a safe distance until it has dried entirely. As soon as the product is dry again, it can’t be used anymore and has to be disposed according to the applicable local  regulations. In case the power station catches fire, it has to be extinguished in the next order: water → sand → fire blanket → dry powder → carbon dioxide fire extinguisher.
  8. Only use the product on flat surfaces in order to protect the product from falling over. Immediately stop operating/using the product after falling or other external impact on the power station and avoid strong vibrations during use. Turn of the power  supply immediately after any strong impact and place the battery in a safe and open area. Finally, dispose the product according to the local regulations.
  9. Only use a dry textile to clean the outside of the product.
  10. Please keep the product out of reach from children and pets.
  11. In case the product is used for the operation of standard medical equipment, please make sure the power status is monitored carefully, in order to prevent that the power runs out. Please contact Evebase about any restrictions for the use with medical  equipment.
  12. Please make sure there is a safe distance between medical implants and the power station, as this product will generate an electromagnetic field. Please contact Evebase if you need more information about any restrictions.
  13. Avoid usage in a strong static electric/ magnetic field.
  14. Avoid usage/ storage near any heat source (fire, car in direct sunlight etc.).
  15. Don’t use any wires or metal objects that can result in a short circuit.
  16. No items can be stacked on top of the product.
  17. If the battery is swollen, leaking or smelly, stop using it immediately.
  18. Please make sure the power station is completely discharged before disposal in an official battery recycling bin. It is prohibited to dispose the product in a standard trash can. Please follow the local regulations.
  19. Please contact a professional battery recycling company in case the power station can’t be discharged completely due to a failure.
  20. For long-term storage, please consume power from full power to no power once every 3 months, and then recharge to about 50%.
  21. Please avoid shipping a product with a battery power level higher than 30% and don’t take it on a plane.

AC OUTPUT PARAMETER

Type of AC port AC output
100V~120V 50/60Hz
220V 50Hz
230V 50Hz
220V~240V 50Hz
220V 60Hz

PRODUCT INTRODUCTION

This product is a high power portable power station, suitable for family emergency power cuts, outdoor travel, emergency relief, field work and other scenarios.
The product has a built-in LiFePO4 battery, which supports adapter, car charger, photo-voltaic panel and other charging methods. The AC output voltage corresponds to different national specifications (see previous page) and a number of USB ports supply for lighting, ventilator, electric fan, router, notebook and other equipment. Thanks to the 2000W high power maximum output and pure sine wave AC output this power station can even be used for most household appliances.
Through the 1100W ultra-fast charging, this model can be full charged within 2 hours. The AC input/output voltage frequency can be switched automatic or manually between 50Hz/60Hz. This product also supports maximum 5OOW solar charge, allowing you to charge the device, even without access to a power grid.

EVEBASE 2000 Power Station Move - PRODUCT INTRODUCTION

1 Main power control
2 Light control
3 USB control
4 DC control
5 LCD display| 6 Air intake/outlet
7 AC on off control (50Hz/60Hz switching control)
8 Anderson input (solar panel)
9 AC input port
10 Overload protection
---|---

  1. Main power control
    Operate method: Press the main power control button for 3 seconds to turn the system on/off

  2. Led light control
    Operate method: Shortly press the button to turn it on and to change the light mode (SOS/Flash).
    You can turn off the light by pressing the button for 1-2 seconds in any mode.

  3. USB button
    Operate method: short press to turn on/offEVEBASE 2000 Power Station Move -
USB button

  4. DC button
    Operate method: short press to turn on/off.EVEBASE 2000 Power Station Move -
DC button

  5. LCD display
    The display shows the remaining power and different using data.

  6. Cooling system
    When the fans are working, please do not block the channel.

  7. AC button (AC output, total combined 2000W)
    Operate method: short press to turn on/off.
    Note:
    1. Please check the output voltage or frequency before using
    2. Press the button for 2 seconds to enter the frequency changing mode. 50Hz and 60Hz will flash on the display. Press the button again to choose the correct frequency. Wait until the frequency stops flashing.

  8. Solar panel input
    Use the Anderson port to connect the solar panel.
    1. Solar panels can have a maximum input of 500W and a maximum voltage of 50V
    2. Exceeding the maximum voltage will lead to damage on the equipment. This is beyond the scope of warranty.

  9. AC input
    Use a wall socket in order to get to 1100W fast charging. This fully charges the device from 0-100% in 2 hours.
    – The product can be charged directly by the wall socked, but please avoid the use of extension cords and cable taps. When the product is charging, please do not plug other devices in the same socket.
    – Do not plug several devices together in an extension socket at once. The current will be to high and bring damage to the cable, which may result in fire.
    – Do not use the same socket to connect other devices when charging this product. When the same wiring in a general household exceeds 1500W, the safety circuit breaker will be activated.

  10. Overload protector
    An overload protector is added in order to protect this product. This prevents damage to the product due to excessive AC input current, cause by lightning and power grid fluctuations. When such a situation occurs, the overload protector will start to cut off the AC input to protect the product.
    Restore the AC input function of the product with the following steps:
    1. Turn of the power and unplug all ports.
    2. After confirming that all parts are normal, turn on the power button.
    3. Press the overload protection button to switch on the AC line to restore AC input.

LCD DISPLAY

EVEBASE 2000 Power Station Move - LCD DISPLAY

1 Charging/ using time
2 Fan state
3 High/low temperature protection
4 Power percentage
5 Total input power| 6 Total output power
7 LED light
8 AC output
9 Type-C output
10 USB output| 11 AC charging
12 Anderson charging
13 DC output
14 Car port output
15 XT-60 output
---|---|---
| When this icon lights up, please keep the air intake/ outlet unobstructed.
---|---
| When this icon lights up, please note that the operating temperature of the device is too high or too low. The device will possibly stop working until the temperature is back to the normal standard.
| When this icon is flashing, it shows that the AC input is wrong. Please check the power cable.
| When this icon is flashing, it means the output is wrong.

UPS MODE

This power station has a build in ‘’bypass mode’’ functionality, meaning that in case of a power grid shut down, the power station automatically switches (within 10ms) from the power grid to the internal battery capacity to supply power.
As demonstrated in the picture below, you can connect the power station between the wall socket and your electrical appliances. When you turn on the electrical appliances, they will directly use the AC power from the wall socket (power grid) and don’t use any of the battery capacity.
When the power grid is cut off, it will immediately switch to the internal battery capacity, in order for you to keep on working. Evebase is not responsible for any abnormal operation or data loss caused by careless use.
– In case the power station jumps into UPS mode in Europe or the United Kingdom and the AC output exceeds the maximum power of 2000W, the AC output icon will start to flash, indicating overload.

EVEBASE 2000 Power Station Move - This power station

SOLAR PANEL CHARGING

The product can be charged through solar panels. Maximum solar panel input is 500W (maximum 50V voltage).
– The solar panel charging power may fluctuate according to the weather conditions.
– Solar panel voltage exceeding 50V will damage the equipment and isn’t covered by warranty.

EVEBASE 2000 Power Station Move - SOLAR PANEL CHARGING

CAR CHARGING

This power station can be charged by the cigarette lighter in the car, with an ACC cable. Turn on the power of this power station, connect the ACC charging cable to the cigarette lighter in the car and to the Anderson interface on the side of the power station. After starting the engine of the car, the LCD screen of the power station will show the input power.
– On-board charging should be carried out with the car engine turned on. If the engine of the car is not turned on, the battery of the car might run out.
– The charging time while charging by car is long, due to the low power output of 90-120W.

EVEBASE 2000 Power Station Move - CAR CHARGING

PRODUCT SPECIFICATIONS

Product Eve Base Power Station Move 2000W
Product dimensions LWH = 392279323mm
Product net weight 22 kg
Rated capacity 1997Wh
AC Charging 50/60Hz 1100W max
MPPT input 11.5-50V 20A 500W max
AC Output 50/60Hz (frequency switch available), rated 2000W, peak 4000W, pure

sine wave. Built-in overload and short circuit protection.
USB QC 3.0| 18W x2
USB| USB-A (5V 2.4A) x2
Type-C| 5-20V/5.0A, PD3.0 100W x2
DC5521| 12V/3A x2
XT-60 output| 12V/25A
Car port output| 12V/10A
Power off current| <500uA
Operating temperature| -10°C ~ 40°C
Charging temperature| 0°C ~ 40°C
Working environment humidity| <90%RH
Type of battery| 32130 LiFePO4
Single cell rated voltage| 3.2V
Single cell rated capacity| 13Ah
Battery pack rated voltage| 51.2V
Battery pack output voltage range| 43.2-57.6V
Battery pack rated capacity| 1997Wh
Battery pack maintenance| If not used for 3 months, product should be recharged

PROBLEMS AND RESOLUTIONS

Status Possible cause Resolution
Above icons flash and buzzing alarm. Exceeding standard output, short
circuit. 1.Remove the load.

2.Check if the overload protector is up. If it is up, press the overload protection button and press the AC button.
3.If the overload protector doesn’t jump up, directly press AC output restore output function.
Above icon flashes and buzzing alarm.| The equipment temperature is too high or too low.| 1.Remove the equipment and turn off the power of this product.
2.Restart the machine when it is cooled down.
3.Place the equipment in a -10°C — 40°C environment.
4.Please check if the fan is running normally and is ventilated.
Charging unavailable| The adapter has a poor connection.| Confirm the connection status of the cable and the power supply status.
Overload protection function activated.| 1.Turn off the power button and remove cables from all ports.
2.After checking if all components are normal, turn on the power button.
3.Press the overload protection button to connect the AC cable to recover AC input.

EVEBASE logo

EveBase Tech B.V.
Oostwal 2
1747 EZ
Tuitjenhorn
The Netherlands
support@evebase.com
www.evebase.com
Designed in NL. Made in PRC.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals